Commit Graph

360 Commits

Author SHA1 Message Date
Joseph Doherty
c8a38bc57b DiffViewer refactor — 6-section plugin pattern + 1000-row cap. Closes task #156 (Phase 6.4 Stream C). Replaces the flat single-table rendering that mixed Namespace/DriverInstance/Equipment/Tag rows into one untyped list with a per-section-card layout that makes draft review actually scannable on non-trivial diffs. New DiffSection.razor reusable component encapsulates the per-section rendering — card header shows Title + Description + a three-badge summary (+added / −removed / ~modified plus a "no changes" grey badge when the section is empty) so operators can glance at a six-card page and see what areas of the draft actually shifted before drilling into any one table. Hard row-cap at DefaultRowCap=1000 per section lives inside the component so a pathological draft (e.g. 20k tags churned by a block rebuild) can't freeze the browser on render — excess rows are silently dropped with a yellow warning banner that surfaces "Showing the first 1000 of N rows" + a pointer to run sp_ComputeGenerationDiff directly for the full set. Body max-height: 400px + overflow-y: auto gives each section its own scroll region so one big section doesn't push the others off screen. DiffViewer.razor refactored to a static Sections table driving a single foreach that instantiates one DiffSection per known TableName. Sections listed in author-order (Namespace → DriverInstance → Equipment → Tag → UnsLine → NodeAcl) — six entries matching the task acceptance criterion. The first four correspond to what sp_ComputeGenerationDiff currently emits; the last two (UnsLine + NodeAcl) render as empty "no changes" cards today + will light up when the proc is extended (tracked in task #196 for NodeAcl; UnsLine proc extension is a natural follow-up since UnsImpactAnalyzer already tracks UNS moves). RowsFor(tableName) replaces the prior flat table — each section filters the overall DiffRow list by its TableName so the proc output format stays stable. Header-bar summary at the top of the page now reads "N rows across M of 6 sections" so operators see overall change weight at a glance before scanning. Two Razor-specific fixes landed along the way: loop variable renamed from section to sec because @section collides with the Razor section directive + trips RZ2005; helper method renamed from Group to RowsFor because the Razor generator gets confused by a parameter-flowing method whose name clashes with LINQ's Group extension (the source-gen output referenced TypeCheck<T> with no argument). Admin project builds 0 errors; Admin.Tests suite 76/76 (unchanged — the refactor is structural + no service-layer logic changed, so the existing DraftValidator + EquipmentService + AdminServicesIntegrationTests cover the consuming paths). No bUnit in this project so the cap behavior isn't unit-tested at the component level; DiffSection.OnParametersSet is small + deterministic (int counts + Take(RowCap)) + reviewed before ship.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 22:23:22 -04:00
cecb84fa5d Merge pull request (#136) - Admin RedundancyTab 2026-04-19 22:16:20 -04:00
Joseph Doherty
13d5a7968b Admin RedundancyTab — per-cluster read-only topology view. Closes the UI slice of task #149 (Phase 6.3 Stream E — Admin UI RedundancyTab + OpenTelemetry metrics + SignalR); the OpenTelemetry metrics + RoleChanged SignalR push are split into new follow-up task #198 because each is a structural add that deserves its own test matrix + NuGet-dep decision rather than riding this UI PR. New /clusters/{ClusterId} Redundancy tab slotted between ACLs and Audit in the existing ClusterDetail tab bar. Shows each ClusterNode row in the cluster with columns Node / Role (Primary green, Secondary blue, Standalone primary-blue badge) / Host / OPC UA port / ServiceLevel base / ApplicationUri (text-break so the long urn: doesn't blow out the table) / Enabled badge / Last seen (relative age via the same FormatAge helper as Hosts.razor, with a yellow "Stale" chip once LastSeenAt crosses the 30s threshold shared with HostStatusService.StaleThreshold — a missed heartbeat plus clock-skew buffer). Four summary cards above the table — total Nodes, Primary count, Secondary count, Stale count. Two guard-rail alerts: (a) red "No Primary or Standalone" when the cluster has no authoritative write target (all rows are Secondaries — read-only until one is promoted by the server-side RedundancyCoordinator apply-lease flow); (b) red "Split-brain" when >1 Primary exists — apply-lease enforcement at the coordinator level should have made this impossible, so the alert implies a hand-edited DB row + an investigation. New ClusterNodeService with ListByClusterAsync (ordered by ServiceLevelBase descending so Primary rows with higher base float to the top) + a static IsStale predicate matching HostStatusService's 30s convention. DI-registered alongside the existing scoped services in Program.cs. Writes (role swap, enable/disable) are deliberately absent from the service — they go through the RedundancyCoordinator apply-lease flow on the server side + direct DB mutation from Admin would race with it. New ClusterNodeServiceTests covering IsStale across null/recent/old LastSeenAt + ListByClusterAsync ordering + cluster filter. 4/4 new tests passing; full Admin.Tests suite 76/76 (was 72 before this PR, +4). Admin project builds 0 errors. Task #198 captures the deferred work: (1) OpenTelemetry Meter for primary/secondary/stale counts + role_transition counter with from/to/node tags + OTLP exporter config; (2) RoleChanged SignalR push — extend FleetStatusPoller to detect RedundancyRole changes on ClusterNode rows + emit a RoleChanged hub message so the RedundancyTab refreshes instantly instead of on-page-load polling.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 22:14:25 -04:00
d1686ed82d Merge pull request (#135) - Equipment CSV import UI 2026-04-19 22:02:36 -04:00
Joseph Doherty
ac69a1c39d Equipment CSV import UI — Stream B.3/B.5 operator page + EquipmentTab "Import CSV" button. Closes the UI slice of task #163 (Phase 6.4 Stream B.3/B.5); the ExternalIdReservation merge follow-up inside FinaliseBatchAsync is split into new task #197 so it gets a proper concurrent-insert test matrix rather than riding this UI PR. New /clusters/{ClusterId}/draft/{GenerationId}/import-equipment page driving the full staged-import flow end-to-end. Operator selects a driver instance + UNS line (both scoped to the draft generation via DriverInstanceService.ListAsync + UnsService.ListLinesAsync dropdowns), pastes or uploads a CSV (InputFile with 5 MiB cap so pathological files can't OOM the server), clicks Parse — EquipmentCsvImporter.Parse runs + shows two side-by-side cards (accepted rows in green with ZTag/Machine/Name/Line columns, rejected rows in red with line-number + reason). Click Stage + Finalise and the page calls CreateBatchAsync → StageRowsAsync → FinaliseBatchAsync in sequence using the authenticated user's identity as CreatedBy; on success, 600ms banner then NavigateTo back to the draft editor so operator sees the newly-imported rows in EquipmentTab without a manual refresh. Parse errors (missing version marker, bad header, malformed CSV) surface InvalidCsvFormatException.Message inline alongside the Parse button — no page reload needed to retry. Finalise errors surface the service-layer exception message (ImportBatchNotFoundException / ImportBatchAlreadyFinalisedException / any DbUpdate* exception from the atomic transaction) so operator sees exactly why the finalise rejected before the tx rolled back. EquipmentTab gains an "Import CSV…" button next to "Add equipment" that NavigateTo's the new page; it needs a ClusterId parameter to build the URL so the @code block adds [Parameter] string ClusterId, and DraftEditor now passes ClusterId="@ClusterId" alongside the existing GenerationId. EquipmentImportBatchService was already implemented in Phase 6.4 Stream B.4 but missing from the Admin DI container — this PR adds AddScoped so the @inject resolves. The FinaliseBatch docstring explicitly defers ExternalIdReservation merge as a narrower follow-up with a concurrent-insert test matrix — task #197 captures that work. For now the finalise may surface a DB-level UNIQUE-constraint violation if a ZTag conflict exists at commit time; the UI shows the raw message + the batch + staged rows are still in the DB for re-use once the conflict is resolved. Admin project builds 0 errors; Admin.Tests 72/72 passing.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 22:00:40 -04:00
30714831fa Merge pull request (#134) - Admin RoleGrants page 2026-04-19 21:48:14 -04:00
Joseph Doherty
44d4448b37 Admin RoleGrants page — LDAP-group → Admin-role mapping CRUD. Closes the RoleGrantsTab slice of task #144 (Phase 6.2 Stream D follow-up); the remaining three sub-items (Probe-this-permission on AclsTab, SignalR invalidation on role/ACL changes, draft-diff ACL section) are split into new follow-up task #196 so each can ship independently. The permission-trie evaluator + ILdapGroupRoleMappingService already exist from Phase 6.2 Streams A + B — this PR adds the consuming UI + the DI registration that was missing. New /role-grants page at Components/Pages/RoleGrants.razor registered in MainLayout's sidebar next to Certificates. Lists every LdapGroupRoleMapping row with columns LDAP group / Role / Scope (Fleet-wide or Cluster:X) / Created / Notes / Revoke. Add-grant form takes LDAP group DN + AdminRole dropdown (ConfigViewer, ConfigEditor, FleetAdmin) + Fleet-wide checkbox + Cluster dropdown (disabled when Fleet-wide checked) + optional Notes. Service-layer invariants — IsSystemWide=true + ClusterId=null, or IsSystemWide=false + ClusterId populated — enforced in ValidateInvariants; UI catches InvalidLdapGroupRoleMappingException and displays the message in a red alert. ILdapGroupRoleMappingService was present in the Configuration project from Stream A but never registered in the Admin DI container — this PR adds the AddScoped registration so the injection can resolve. Control-plane/data-plane separation note rendered in an info banner at the top of the page per decision #150 (these grants do NOT govern OPC UA data-path authorization; NodeAcl rows are read directly by the permission-trie evaluator without consulting role mappings). Admin project builds 0 errors; Admin.Tests 72/72 passing. Task #196 created to track: (1) AclsTab Probe-this-permission form that takes (ldap group, node path, permission flag) and runs it through the permission trie, showing which row granted it + the actual resolved grant; (2) SignalR invalidation — push a RoleGrantsChanged event when rows are created/deleted so connected Admin sessions reload without polling, ditto NodeAclChanged on ACL writes; (3) DiffViewer ACL section — show NodeAcl + LdapGroupRoleMapping deltas between draft + published alongside equipment/uns diffs.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 21:46:21 -04:00
572f8887e4 Merge pull request (#133) - IdentificationFields editor + edit mode 2026-04-19 21:43:18 -04:00
Joseph Doherty
2acea08ced Admin Equipment editor — IdentificationFields component + edit mode + three missing OPC 40010 fields. Closes the UI-editor slice of task #159 (Phase 6.4 Stream D remaining); the DriverNodeManager wire-in + ACL integration test are split into a new follow-up task #195 because they're blocked on a prerequisite that hasn't shipped — the DriverNodeManager does not currently materialize Equipment nodes at all (NodeScopeResolver has an explicit "A future resolver will..." TODO in its decomposition docstring). Shipping the IdentificationFolderBuilder call before the parent walker exists would wire a call that no code path hits, so the wire-in is deferred until the Equipment node walker lands first. New IdentificationFields.razor reusable component renders the 9-field decision #139 grid in a Bootstrap 3-column layout — Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, YearOfConstruction (InputNumber), AssetLocation, ManufacturerUri (placeholder https://…), DeviceManualUri (placeholder https://…). Takes a required Equipment parameter + 2-way binds every field; no state of its own. Three fields that were missing from the old inline form — AssetLocation, ManufacturerUri, DeviceManualUri — now present, matching IdentificationFolderBuilder.FieldNames exactly. EquipmentTab.razor refactored to consume the component in both create + edit flows. Each table row gains an Edit button next to Remove. StartEdit clones the row into _draft so Cancel doesn't mutate the displayed list row with in-flight edits; on Save, UpdateAsync persists through EquipmentService's existing update path which already handles all 9 Identification fields. SaveAsync branches on _editMode — create still derives EquipmentId from a fresh Uuid via DraftValidator per decision #125, edit keeps the original EquipmentId + EquipmentUuid (immutable once set). FormName renamed equipment-form (was new-equipment) to work for both flows. Admin project builds 0 errors; Admin.Tests 72/72 passing. No new tests shipped — this PR is strictly a Razor-component refactor + two new bound fields + an Edit branch; the existing EquipmentService tests cover both the create + update paths. Task #195 created to track the blocked server-side work: call IdentificationFolderBuilder.Build from DriverNodeManager once the Equipment walker exists, plus an integration test browsing Equipment/Identification as an unauthorized user asserting BadUserAccessDenied per the builder's cross-reference note in docs/v2/acl-design.md §Identification.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 21:41:13 -04:00
49f6c9484e Merge pull request (#132) - Admin /hosts red-badge + Polly telemetry observer 2026-04-19 21:38:11 -04:00
Joseph Doherty
d06cc01a48 Admin /hosts red-badge + resilience columns + Polly telemetry observer. Closes task #164 (the remaining slice of Phase 6.1 Stream E.3 after the earlier publisher + hub PR). Three cooperating pieces wired together so the operator-facing /hosts table actually reflects the live Polly counters that the pipeline builder is producing. DriverResiliencePipelineBuilder gains an optional DriverResilienceStatusTracker ctor param — when non-null, every built pipeline wires Polly's OnRetry/OnOpened/OnClosed strategy-options callbacks into the tracker. OnRetry → tracker.RecordFailure (so ConsecutiveFailures climbs per retry), OnOpened → tracker.RecordBreakerOpen (stamps LastCircuitBreakerOpenUtc), OnClosed → tracker.RecordSuccess (resets the failure counter once the target recovers). Absent tracker = silent, preserving the unit-test constructor path + any deployment that doesn't care about resilience observability. Cancellation stays excluded from the failure count via the existing ShouldHandle predicate. HostStatusService.HostStatusRow extends with four new fields — ConsecutiveFailures, LastCircuitBreakerOpenUtc, CurrentBulkheadDepth, LastRecycleUtc — populated via a second LEFT JOIN onto DriverInstanceResilienceStatuses keyed on (DriverInstanceId, HostName). LEFT JOIN because brand-new hosts haven't been sampled yet; a missing row means zero failures + never-opened breaker, which is the correct default. New FailureFlagThreshold constant (=3, matches plan decision #143's conservative half-of-breaker convention) + IsFlagged predicate so the UI can pre-warn before the breaker actually trips. Hosts.razor paints three new columns between State and Last-transition — Fail# (bold red when flagged), In-flight (bulkhead-depth proxy), Breaker-opened (relative age). Per-row "Flagged" red badge alongside State when IsFlagged is true. Above the first cluster table, a red alert banner summarises the flagged-host count when ≥1 host is flagged, so operators see the problem before scanning rows. Three new tests in DriverResiliencePipelineBuilderTests — Tracker_RecordsFailure_OnEveryRetry verifies ConsecutiveFailures reaches RetryCount after a transient-forever operation, Tracker_StampsBreakerOpen_WhenBreakerTrips verifies LastBreakerOpenUtc is set after threshold failures on a Write pipeline, Tracker_IsolatesCounters_PerHost verifies one dead host does not leak failure counts into a healthy sibling. Full suite — Core.Tests 14/14 resilience-builder tests passing (11 existing + 3 new), Admin.Tests 72/72 passing, Admin project builds 0 errors. SignalR live push of status changes + browser visual review are deliberately left to a follow-up — this PR keeps the structural change minimal (polling refresh already exists in the page's 10s timer; SignalR would be a structural add that touches hub registration + client subscription).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 21:35:54 -04:00
5536e96b46 Merge pull request (#131) - AbCip UDT Template reader 2026-04-19 21:23:34 -04:00
Joseph Doherty
ece530d133 AB CIP UDT Template Object shape reader. Closes the shape-reader half of task #179. CipTemplateObjectDecoder (pure-managed) parses the Read Template blob per Rockwell CIP Vol 1 + libplctag ab/cip.c handle_read_template_reply — 12-byte header (u16 member_count + u16 struct_handle + u32 instance_size + u32 member_def_size) followed by memberCount × 8-byte member blocks (u16 info with bit-15 struct flag + lower-12-bit type code matching the Symbol Object encoding, u16 array_size, u32 struct_offset) followed by semicolon-terminated strings (UDT name first, then one per member). ParseSemicolonTerminatedStrings handles the observed firmware variations — name;\0 vs name; delimiters, optional null/space padding after the semicolon, trailing-name-without-semicolon corner case. Struct-flag members decode as AbCipDataType.Structure; unknown atomic codes fall back to Structure so the shape remains valid even with unrecognised members. Zero member count + short buffer both return null; missing member names yield <member_N> placeholders. IAbCipTemplateReader + IAbCipTemplateReaderFactory abstraction — one call per template instance id returning the raw blob. LibplctagTemplateReader is the production implementation creating a libplctag Tag with name @udt/{templateId} + handing the buffer to the decoder. AbCipDriver ctor gains optional templateReaderFactory parameter (defaults to LibplctagTemplateReaderFactory) + new internal FetchUdtShapeAsync that — checks AbCipTemplateCache first, misses call the reader + decode + cache, template-read exceptions + decode failures return null so callers can fall back to declaration-driven fan-out without the whole discovery blowing up. OperationCanceledException rethrows for shutdown propagation. Unknown device host returns null without attempting a fetch. FlushOptionalCachesAsync empties the cache so a subsequent fetch re-reads. 16 new decoder tests — simple two-member UDT, struct-member flag → Structure, array member ArrayLength, 6-member mixed-type with correct offsets, unknown type code → Structure, zero member count → null, short buffer → null, missing member name → placeholder, ParseSemicolonTerminatedStrings theory across 5 shapes. 6 new AbCipFetchUdtShapeTests exercising the driver integration via reflection (method is internal) — happy-path decode + cache, different template ids get separate fetches, unknown device → null without reader creation, decode failure returns null + doesn't cache (next call retries), reader exception returns null, FlushOptionalCachesAsync clears the cache. Total AbCip unit tests now 211/211 passing (+19 from the @tags merge's 192); full solution builds 0 errors; other drivers untouched. Whole-UDT read optimization (single libplctag call returning the packed buffer + client-side member decode using the template offsets) is left as a follow-up — requires rethinking the per-tag read path + careful hardware validation; current per-member fan-out still works correctly, just with N round-trips instead of 1.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 21:21:42 -04:00
b55cef5f8b Merge pull request (#130) - AbCip @tags walker 2026-04-19 21:15:16 -04:00
Joseph Doherty
088c4817fe AB CIP @tags walker — CIP Symbol Object decoder + LibplctagTagEnumerator. Closes task #178. CipSymbolObjectDecoder (pure-managed, no libplctag dep) parses the raw Symbol Object (class 0x6B) blob returned by reading the @tags pseudo-tag into an enumerable sequence of AbCipDiscoveredTag records. Entry layout per Rockwell CIP Vol 1 + Logix 5000 CIP Programming Manual 1756-PM019, cross-checked against libplctag's ab/cip.c handle_listed_tags_reply — u32 instance-id + u16 symbol-type + u16 element-length + 3×u32 array-dims + u16 name-length + name[len] + even-pad. Symbol-type lower 12 bits carry the CIP type code (0xC1 BOOL, 0xC2 SINT, …, 0xD0 STRING), bit 12 is the system-tag flag, bit 15 is the struct flag (when set lower 12 bits become the template instance id). Truncated tails stop decoding gracefully — caller keeps whatever parsed cleanly rather than getting an exception mid-walk. Program:-scope names (Program:MainProgram.StepIndex) are split via SplitProgramScope so the enumerator surfaces scope + simple name separately. 12 atomic type codes mapped (BOOL/SINT/INT/DINT/LINT/USINT/UINT/UDINT/ULINT/REAL/LREAL/STRING + DT/DATE_AND_TIME under Dt); unknown codes return null so the caller treats them as opaque Structure. LibplctagTagEnumerator is the real production walker — creates a libplctag Tag with name=@tags against the device's gateway/port/path, InitializeAsync + ReadAsync + GetBuffer, hands bytes to the decoder. Factory LibplctagTagEnumeratorFactory replaces EmptyAbCipTagEnumeratorFactory as the AbCipDriver default. AbCipDriverOptions gains EnableControllerBrowse (default false) matching the TwinCAT pattern — keeps the strict-config path for deployments where only declared tags should appear. When true, DiscoverAsync walks each device's @tags + emits surviving symbols under Discovered/ sub-folder. System-tag filter (AbCipSystemTagFilter shipped in PR 5) runs alongside the wire-layer system-flag hint. Tests — 18 new CipSymbolObjectDecoderTests with crafted byte arrays matching the documented layout — single-entry DInt, theory across 12 atomic type codes, unknown→null, struct flag override, system flag surface, Program:-scope split, multi-entry wire-order with even-pad, truncated-buffer graceful stop, empty buffer, SplitProgramScope theory across 6 shapes. 4 pre-existing AbCipDriverDiscoveryTests that tested controller-enumeration behavior updated with EnableControllerBrowse=true so they continue exercising the walker path (behavior unchanged from their perspective). Total AbCip unit tests now 192/192 passing (+26 from the RMW merge's 166); full solution builds 0 errors; other drivers untouched. Field validation note — the decoder layout matches published Rockwell docs + libplctag C source, but actual @tags responses vary slightly by controller firmware (some ship an older entry format with u16 array dims instead of u32). Any layout drift surfaces as gibberish names in the Discovered/ folder; field testing will flag that for a decoder patch if it occurs.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 21:13:20 -04:00
91e6153b5d Merge pull request (#129) - Bit RMW pass 2 (AbCip+AbLegacy) 2026-04-19 20:36:21 -04:00
Joseph Doherty
00a428c444 RMW pass 2 — AbCip BOOL-within-DINT + AbLegacy bit-within-word. Closes task #181. AbCip — AbCipDriver.WriteAsync now detects BOOL writes with a bit index + routes them through WriteBitInDIntAsync: strip the .N suffix to form the parent DINT tag path (via AbCipTagPath with BitIndex=null + ToLibplctagName), get/create a cached parent IAbCipTagRuntime via EnsureParentRuntimeAsync (distinct from the bit-selector tag runtime so read + write target the DINT directly), acquire a per-parent-name SemaphoreSlim, Read → Convert.ToInt32 the current DINT → (current | 1<<bit) or (current & ~(1<<bit)) → Write via EncodeValue(DInt, updated). Per-parent lock prevents concurrent writers to the same DINT from losing updates — parallels Modbus + FOCAS pass 1. DeviceState gains ParentRuntimes dict + GetRmwLock helper + _rmwLocks ConcurrentDictionary. DisposeHandles now walks ParentRuntimes too. LibplctagTagRuntime.EncodeValue's BOOL-with-bitIndex branch stays as a defensive throw (message updated to point at the new driver-level dispatch) so an accidental bypass fails loudly rather than silently clobbering the whole DINT. AbLegacy — identical pattern for PCCC N-file bit writes. AbLegacyDriver.WriteAsync detects Bit with bitIndex + PMC letter not in {B, I, O} (B-file + I/O use their own bit-addressable semantics so don't RMW at N-file word level), routes through WriteBitInWordAsync which uses Int16 for the parent word, creates + caches a parent runtime with the suffix-stripped N7:0 address, acquires per-parent lock, RMW. DeviceState extended the same way as AbCip (ParentRuntimes + GetRmwLock). LibplctagLegacyTagRuntime.EncodeValue Bit-with-bitIndex branch points at the driver dispatch. Tests — 5 new AbCipBoolInDIntRmwTests (bit set ORs + preserves, bit clear ANDs + preserves, 8-way concurrent writes to same parent compose to 0xFF, different-parent writes get separate runtimes, repeat bit writes reuse the parent runtime init-count 1 + write-count 2), 4 new AbLegacyBitRmwTests (bit set preserves, bit clear preserves 0xFFF7, 8-way concurrent 0xFF, repeat writes reuse parent). Two pre-existing tests flipped — AbCipDriverWriteTests.Bit_in_dint_write_returns_BadNotSupported + AbLegacyReadWriteTests.Bit_within_word_write_rejected_as_BadNotSupported both now assert Good instead of BadNotSupported, renamed to _now_succeeds_via_RMW. Total tests — AbCip 166/166, AbLegacy 96/96, full solution builds 0 errors; Modbus + FOCAS + TwinCAT + other drivers untouched. Task #181 done across all four libplctag-backed + non-libplctag drivers (Modbus BitInRegister + AbCip BOOL-in-DINT + AbLegacy N-file bit + FOCAS PMC Bit — all with per-parent-word serialisation).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 20:34:29 -04:00
07fd105ffc Merge pull request (#128) - Bit RMW pass 1 (Modbus+FOCAS) 2026-04-19 20:27:17 -04:00
Joseph Doherty
8c309aebf3 RMW pass 1 — Modbus BitInRegister + FOCAS PMC Bit write paths. First half of task #181 — the two drivers where read-modify-write is a clean protocol-level insertion (Modbus FC03/FC06 round-trip + FOCAS pmc_rdpmcrng / pmc_wrpmcrng round-trip). Per-driver SemaphoreSlim registry keyed on the parent word address serialises concurrent bit writes so two writers targeting different bits in the same word don't lose one another's update. Modbus — ModbusDriver gains WriteBitInRegisterAsync + _rmwLocks ConcurrentDictionary. WriteOneAsync routes BitInRegister (HoldingRegisters region only) through RMW ahead of the normal encode path. Read uses FC03 Read Holding Registers for 1 register at tag.Address, bit-op on the returned ushort via (current | 1<<bit) for set / (current & ~(1<<bit)) for clear, write back via FC06 Write Single Register. Per-address lock prevents concurrent bit writes to the same register from racing. Rejects out-of-range bits (0-15) with InvalidOperationException. EncodeRegister's BitInRegister branch repurposed as a defensive guard — if a non-RMW caller ever reaches it, throw so an unintended bypass stays loud rather than silently clobbering. FOCAS — FwlibFocasClient gains WritePmcBitAsync + _rmwLocks keyed on {addrType}:{byteAddr}. Driver-layer WriteAsync routes Bit writes with a bitIndex through the new path; other Pmc writes still hit the direct pmc_wrpmcrng path. RMW uses cnc_rdpmcrng + Byte dataType to grab the parent byte, bit-op with (current | 1<<bit) or (current & ~(1<<bit)), cnc_wrpmcrng to write back. Rejects out-of-range bits (0-7, FOCAS PMC bytes are 8-bit) with InvalidOperationException. EncodePmcValue's Bit branch now treats a no-bitIndex case as whole-byte boolean (non-zero / zero); bitIndex-present writes never hit this path because they dispatch to WritePmcBitAsync upstream. Tests — 5 new ModbusBitRmwTests + 4 new FocasPmcBitRmwTests + 1 renamed pre-existing test each covering — bit set preserves other bits, bit clear preserves other bits, concurrent bit writes to same word/byte compose correctly (8-parallel stress), bit writes on different parent words proceed without contention (4-parallel), sequential bit sets compose into 0xFF after all 8. Fake PmcRmwFake in FOCAS tests simulates the PMC byte storage + surfaces it through the IFocasClient contract so the test asserts driver-level behavior without needing Fwlib32.dll. FwlibNativeHelperTests.EncodePmcValue_Bit_throws_NotSupported_for_RMW_gap replaced with EncodePmcValue_Bit_without_bit_index_writes_byte_boolean reflecting the new behavior. ModbusDataTypeTests.BitInRegister_write_is_not_supported_in_PR24 renamed to BitInRegister_EncodeRegister_still_rejects_direct_calls; the message assertion updated to match the new defensive message. Modbus tests now 182/182, FOCAS tests now 119/119; full solution builds 0 errors; AbCip/AbLegacy/TwinCAT untouched (those get their RMW pass in a follow-up since libplctag bit access may need a parallel parent-word handle). Task #181 stays pending until that second pass lands.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 20:25:27 -04:00
d1ca0817e9 Merge pull request (#127) - TwinCAT symbol browser 2026-04-19 20:15:25 -04:00
Joseph Doherty
c95228391d TwinCAT follow-up — Symbol browser via AdsClient + SymbolLoaderFactory. Closes task #188. Adds ITwinCATClient.BrowseSymbolsAsync — IAsyncEnumerable yielding TwinCATDiscoveredSymbol (InstancePath + mapped TwinCATDataType + ReadOnly flag) from the target's flat symbol table. AdsTwinCATClient implementation uses SymbolLoaderFactory.Create(_client, new SymbolLoaderSettings(SymbolsLoadMode.Flat)) + iterates loader.Symbols, maps IEC 61131-3 type names (BOOL/SINT/INT/DINT/LINT/REAL/LREAL/STRING/WSTRING/TIME/DATE/DT/TOD + BYTE/WORD/DWORD/LWORD unsigned-word aliases) through MapSymbolTypeName, checks SymbolAccessRights.Write bit for writable vs read-only. Unsupported types (UDTs / function blocks / arrays / pointers) surface with DataType=null so callers can skip or recurse. TwinCATDriverOptions.EnableControllerBrowse — new bool, default false to preserve the strict-config path. When true, DiscoverAsync iterates each device's BrowseSymbolsAsync, filters via TwinCATSystemSymbolFilter (rejects TwinCAT_*, Constants.*, Mc_*, __*, Global_Version* prefixes + anything empty), skips null-DataType symbols, emits surviving symbols under a per-device Discovered/ sub-folder with InstancePath as both FullName + BrowseName + ReadOnly→ViewOnly/writable→Operate. Pre-declared tags from TwinCATDriverOptions.Tags always emit regardless. Browse failure is non-fatal — exception caught + swallowed, pre-declared tags stay in the address space, operators see the failure in driver health on next read. TwinCATSystemSymbolFilter static class mirrors AbCipSystemTagFilter's shape with TwinCAT-specific prefixes. Fake client updated — BrowseResults list for test setup + FireNotification-style single-invocation on each subscribe, ThrowOnBrowse flag for failure testing. 8 new unit tests — strict path emits only pre-declared when EnableControllerBrowse=false, browse enabled adds Discovered/ folder, filter rejects system prefixes, null-DataType symbols skipped, ReadOnly symbols surface ViewOnly, browse failure leaves pre-declared intact, SystemSymbolFilter theory (10 cases). Total TwinCAT unit tests now 110/110 passing (+17 from the native-notification merge's 93); full solution builds 0 errors; other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 20:13:33 -04:00
9ca80fd450 Merge pull request (#126) - FOCAS capabilities 2026-04-19 20:01:28 -04:00
Joseph Doherty
1d6015bc87 FOCAS PR 3 — ITagDiscovery + ISubscribable + IHostConnectivityProbe + IPerCallHostResolver. Completes the FOCAS driver — 7-interface capability set matching AbCip/AbLegacy/TwinCAT (minus IAlarmSource — Fanuc CNC alarms live in a different API surface, tracked as a future-phase concern). ITagDiscovery emits pre-declared tags under a FOCAS root + per-device sub-folder keyed on the canonical focas://host:port string with DeviceName fallback. Writable → Operate, non-writable → ViewOnly. No native FOCAS symbol browsing — CNCs don't expose a tag catalogue the way Logix or TwinCAT do; operators declare addresses explicitly. ISubscribable consumes the shared PollGroupEngine — 5th consumer of the engine after Modbus + AbCip + AbLegacy + TwinCAT-poll-mode. 100ms interval floor inherited. FOCAS has no native notification/subscription protocol (unlike TwinCAT ADS), so polling is the only option — every subscribed tag round-trips through cnc_rdpmcrng / cnc_rdparam / cnc_rdmacro on each tick. IHostConnectivityProbe uses the existing IFocasClient.ProbeAsync which in the real FwlibFocasClient calls cnc_statinfo (cheap handshake returning ODBST with tmmode/aut/run/motion/alarm state). Probe loop runs when Enabled=true, catches OperationCanceledException during shutdown, falls through to Stopped on exceptions, emits Running/Stopped transitions via OnHostStatusChanged with the canonical focas://host:port as the host-name key. Same-state spurious-event guard under per-device lock. IPerCallHostResolver maps tag full-ref to DeviceHostAddress for Phase 6.1 bulkhead/breaker keying per plan decision #144 — unknown refs fall back to first device, no devices → DriverInstanceId. ShutdownAsync now disposes PollGroupEngine + cancels/disposes per-device probe CTS + disposes cached clients. DeviceState gains ProbeLock / HostState / HostStateChangedUtc / ProbeCts matching the shape used by AbCip/AbLegacy/TwinCAT. 9 new unit tests in FocasCapabilityTests — discovery tag emission with correct SecurityClassification, subscription initial poll raises OnDataChange, shutdown cancels subscriptions, GetHostStatuses entry-per-device, probe Running / Stopped transitions, ResolveHost for known / unknown / no-devices paths. FocasScaffoldingTests updated with Probe.Enabled=false where the default factory would otherwise try to load Fwlib32.dll during the probe-loop spinup. Total FOCAS unit tests now 115/115 passing (+9 from PR 2's 106); full solution builds 0 errors; Modbus / AbCip / AbLegacy / TwinCAT / other drivers untouched. FOCAS driver is real-wire-capable end-to-end — read / write / discover / subscribe / probe / host-resolve for Fanuc FS 0i/16i/18i/21i/30i/31i/32i/Series 35i/Power Mate i controllers once deployment drops Fwlib32.dll beside the server. Closes task #120 subtask FOCAS.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 19:59:37 -04:00
5cfb0fc6d0 Merge pull request (#125) - FOCAS R/W + real P/Invoke 2026-04-19 19:57:31 -04:00
Joseph Doherty
a2c7fda5f5 FOCAS PR 2 — IReadable + IWritable + real FwlibFocasClient P/Invoke. Closes task #193 early now that strangesast/fwlib provides the licensed DLL references. Skips shipping with the Unimplemented stub as the default — FwlibFocasClientFactory is now the production default, UnimplementedFocasClientFactory stays as an opt-in for tests/deployments without FWLIB access. FwlibNative — narrow P/Invoke surface for the 7 calls the driver actually makes: cnc_allclibhndl3 (open Ethernet handle), cnc_freelibhndl (close), pmc_rdpmcrng + pmc_wrpmcrng (PMC range I/O), cnc_rdparam + cnc_wrparam (CNC parameters), cnc_rdmacro + cnc_wrmacro (macro variables), cnc_statinfo (probe). DllImport targets Fwlib32.dll; deployment places it next to the executable or on PATH. IODBPMC/IODBPSD/ODBM/ODBST marshaled with LayoutKind.Sequential + Pack=1 + fixed byte-array unions (avoids LayoutKind.Explicit complexity; managed-side BitConverter extracts typed values from the byte buffer). Internal helpers FocasPmcAddrType.FromLetter (G=0/F=1/Y=2/X=3/A=4/R=5/T=6/K=7/C=8/D=9/E=10 per Fanuc FOCAS/2 spec) + FocasPmcDataType.FromFocasDataType (Byte=0 / Word=1 / Long=2 / Float=4 / Double=5) exposed for testing without the DLL loaded. FwlibFocasClient is the concrete IFocasClient backed by P/Invoke. Construction is licence-safe — .NET P/Invoke is lazy so instantiating the class does NOT load Fwlib32.dll; DLL loads on first wire call (Connect/Read/Write/Probe). When missing, calls throw DllNotFoundException which the driver surfaces as BadCommunicationError via the normal exception path. Session-scoped handle from cnc_allclibhndl3; Dispose calls cnc_freelibhndl. Dispatch on FocasAreaKind — Pmc reads use pmc_rdpmcrng with the right ADR_* + data-type codes + parses the union via BinaryPrimitives LittleEndian, Parameter reads use cnc_rdparam + IODBPSD, Macro reads use cnc_rdmacro + compute scaled double as McrVal / 10^DecVal. Write paths mirror reads. PMC Bit writes throw NotSupportedException pointing at task #181 (read-modify-write gap — same as Modbus / AbCip / AbLegacy / TwinCAT). Macro writes accept int + pass decimal-point count 0 (decimal precision writes are a future enhancement). Probe calls cnc_statinfo with ODBST result. Driver wiring — FocasDriver now IDriver + IReadable + IWritable. Per-device connection caching via EnsureConnectedAsync + DeviceState.Client. ReadAsync/WriteAsync dispatch through the injected IFocasClient — ordered snapshots preserve per-tag status, OperationCanceledException rethrows, FormatException/InvalidCastException → BadTypeMismatch, OverflowException → BadOutOfRange, NotSupportedException → BadNotSupported, anything else → BadCommunicationError + Degraded health. Connect-failure disposes the half-open client. ShutdownAsync disposes every cached client. Default factory switched — constructor now defaults to FwlibFocasClientFactory (backed by real Fwlib32.dll) rather than UnimplementedFocasClientFactory. UnimplementedFocasClientFactory stays as an opt-in. 41 new tests — 14 in FocasReadWriteTests (ordered unknown-ref handling, successful PMC/Parameter/Macro reads routing through correct FocasAreaKind, repeat-read reuses connection, FOCAS error mapping, exception paths, batched order across areas, non-writable rejection, successful write logging, status mapping, batch ordering, cancellation, shutdown disposes), 27 in FwlibNativeHelperTests (12 letter-mapping cases + 3 unknown rejections + 6 data-type mapping + 4 encode helpers + Bit-write NotSupported). Total FOCAS unit tests now 106/106 passing (+41 from PR 1's 65); full solution builds 0 errors; Modbus / AbCip / AbLegacy / TwinCAT / other drivers untouched. FOCAS driver is real-wire-capable from day one — deployment drops Fwlib32.dll beside the server + driver talks to live FS 0i/16i/18i/21i/30i/31i/32i controllers.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 19:55:37 -04:00
c13fe8f587 Merge pull request (#124) - FOCAS scaffolding 2026-04-19 19:49:47 -04:00
Joseph Doherty
285799a954 FOCAS PR 1 — Scaffolding + Core (FocasDriver skeleton + address parser + stub client). New Driver.FOCAS project for Fanuc CNC controllers (FS 0i/16i/18i/21i/30i/31i/32i/Series 35i/Power Mate i) talking via the Fanuc FOCAS/2 protocol. No NuGet reference to a FOCAS library — FWLIB (Fwlib32.dll) is Fanuc-proprietary + per-customer licensed + cannot be legally redistributed, so the driver is designed from the start to accept an IFocasClient supplied by the deployment side. Default IFocasClientFactory is UnimplementedFocasClientFactory which throws with a clear deployment-docs pointer at Create time so misconfigured servers fail fast rather than mysteriously hanging. Matches the pattern other drivers use for swappable wire layers (Modbus IModbusTransport, AbCip IAbCipTagFactory, TwinCAT ITwinCATClientFactory) — but uniquely, FOCAS ships without a production factory because of licensing. FocasHostAddress parses focas://{host}[:{port}] canonical form with default port 8193 (Fanuc-reserved FOCAS Ethernet port). Default-port stripping on ToString for roundtrip stability. Case-insensitive scheme. Rejects wrong scheme, empty body, invalid port, non-numeric port. FocasAddress handles the three addressing spaces a FOCAS driver touches — PMC (letter + byte + optional bit, X/Y for IO, F/G for PMC-CNC signals, R for internal relay, D for data table, C for counter, K for keep relay, A for message display, E for extended relay, T for timer, with .N bit syntax 0-7), CNC parameters (PARAM:n for a parameter number, PARAM:n/N for bit 0-31 of a parameter), macro variables (MACRO:n). Rejects unknown PMC letters, negative numbers, out-of-range bits (PMC 0-7, parameter 0-31), non-numeric fragments. FocasDataType — Bit / Byte / Int16 / Int32 / Float32 / Float64 / String covering the atomic types PMC reads + CNC parameters + macro variables return. ToDriverDataType widens to the Int32/Float32/Float64/Boolean/String surface. FocasStatusMapper covers the FWLIB EW_* return-code family documented in the FOCAS/1 + FOCAS/2 references — EW_OK=0, EW_FUNC=1 → BadNotSupported, EW_OVRFLOW=2/EW_NUMBER=3/EW_LENGTH=4 → BadOutOfRange, EW_PROT=5/EW_PASSWD=11 → BadNotWritable, EW_NOOPT=6/EW_VERSION=-9 → BadNotSupported, EW_ATTRIB=7 → BadTypeMismatch, EW_DATA=8 → BadNodeIdUnknown, EW_PARITY=9 → BadCommunicationError, EW_BUSY=-1 → BadDeviceFailure, EW_HANDLE=-8 → BadInternalError, EW_UNEXP=-10/EW_SOCKET=-16 → BadCommunicationError. IFocasClient + IFocasClientFactory abstraction — ConnectAsync, IsConnected, ReadAsync returning (value, status) tuple, WriteAsync returning status, ProbeAsync for IHostConnectivityProbe. Deployment supplies the real factory; driver assembly stays licence-clean. FocasDriverOptions + FocasDeviceOptions + FocasTagDefinition + FocasProbeOptions — one instance supports N CNCs, tags cross-key by HostAddress + use canonical FocasAddress strings. FocasDriver implements IDriver only (PRs 2-3 add read/write/discover/subscribe/probe/resolver). InitializeAsync parses each device HostAddress + fails fast on malformed strings → Faulted health. 65 new unit tests in FocasScaffoldingTests covering — 5 valid host forms + 8 invalid + default-port-strip ToString, 12 valid PMC addresses across all 11 canonical letters + 3 parameter forms with + without bit + 2 macro forms, 10 invalid address shapes, canonical roundtrip theory, data-type mapping theory, FWLIB EW_* status mapping theory (9 codes + unknown → generic), DriverType, multi-device Initialize + address parsing, malformed-address fault, shutdown, default factory throws NotSupportedException with deployment pointer + Fwlib32.dll mention. Total project count 31 src + 20 tests; full solution builds 0 errors. Other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 19:47:52 -04:00
9da578d5a5 Merge pull request (#123) - TwinCAT native notifications 2026-04-19 18:51:39 -04:00
Joseph Doherty
6c5b202910 TwinCAT follow-up — Native ADS notifications for ISubscribable. Closes task #189 — upgrades TwinCATDriver's subscription path from polling (shared PollGroupEngine) to native AdsClient.AddDeviceNotificationExAsync so the PLC pushes changes on its own cycle rather than the driver polling. Strictly better for latency + CPU — TC2 and TC3 runtimes notify on value change with sub-millisecond latency from the PLC cycle. ITwinCATClient gains AddNotificationAsync — takes symbolPath + TwinCATDataType + optional bitIndex + cycleTime + onChange callback + CancellationToken; returns an ITwinCATNotificationHandle whose Dispose tears the notification down on the wire. Bit-within-word reads supported — the parent word value arrives via the notification, driver extracts the bit before invoking the callback (same ExtractBit path as the read surface from PR 2). AdsTwinCATClient — subscribes to AdsClient.AdsNotificationEx in the ctor, maintains a ConcurrentDictionary<uint, NotificationRegistration> keyed on the server-side notification handle. AddDeviceNotificationExAsync returns Task<ResultHandle> with Handle + ErrorCode; non-NoError throws InvalidOperationException so the driver can catch + retry. Notification event args carry Handle + Value + DataType; lookup in _notifications dict routes the value through any bit-extraction + calls the consumer callback. Consumer-side exceptions are swallowed so a misbehaving callback can't crash the ADS notification thread. Dispose unsubscribes from AdsNotificationEx + clears the dict + disposes AdsClient. NotificationRegistration is ITwinCATNotificationHandle — Dispose fires DeleteDeviceNotificationAsync as fire-and-forget with CancellationToken.None (caller has already committed to teardown; blocking would slow shutdown). TwinCATDriverOptions.UseNativeNotifications — new bool, default true. When true the driver uses native notifications; when false it falls through to the shared PollGroupEngine (same semantics as other libplctag-backed drivers, also a safety valve for targets with notification limits). TwinCATDriver.SubscribeAsync dual-path — if UseNativeNotifications false delegate into _poll.Subscribe (unchanged behavior from PR 3). If true, iterate fullReferences, resolve each to its device's client via EnsureConnectedAsync (reuses PR 2's per-device connection cache), parse the SymbolPath via TwinCATSymbolPath (preserves bit-in-word support), call ITwinCATClient.AddNotificationAsync with a closure over the FullReference (not the ADS symbol — OPC UA subscribers addressed the driver-side name). Per-registration callback bridges (_, value) → OnDataChange event with a fresh DataValueSnapshot (Good status, current UtcNow timestamps). Any mid-registration failure triggers a try/catch that disposes every already-registered handle before rethrowing, keeping the driver in a clean never-existed state rather than half-registered. UnsubscribeAsync dispatches on handle type — NativeSubscriptionHandle disposes all its cached ITwinCATNotificationHandles; anything else delegates to _poll.Unsubscribe for the poll fallback. ShutdownAsync tears down native subs first (so AdsClient-level cleanup happens before the client itself disposes), then PollGroupEngine, then per-device probe CTS + client. NativeSubscriptionHandle DiagnosticId prefixes with twincat-native-sub- so Admin UI + logs can distinguish the paths. 9 new unit tests in TwinCATNativeNotificationTests — native subscribe registers one notification per tag, pushed value via FireNotification fires OnDataChange with the right FullReference (driver-side, not ADS symbol), unsubscribe disposes all notifications, unsubscribe halts future notifications, partial-failure cleanup via FailAfterNAddsFake (first succeeds, second throws → first gets torn down + Notifications count returns to 0 + AddCallCount=2 proving the test actually exercised both calls), shutdown disposes subscriptions, poll fallback works when UseNativeNotifications=false (no native handles created + initial-data push still fires), handle DiagnosticId distinguishes native vs poll. Existing poll-mode ISubscribable tests in TwinCATCapabilityTests updated with UseNativeNotifications=false so they continue testing the poll path specifically — both poll + native paths have test coverage now. TwinCATDriverTests got Probe.Enabled=false added because the default factory creates a real AdsClient which was flakily affected by parallel test execution sharing AMS router state. Total TwinCAT unit tests now 93/93 passing (+8 from PR 3's 85 counting the new native tests + 2 existing tests that got options tweaks). Full solution builds 0 errors; Modbus / AbCip / AbLegacy / other drivers untouched. TwinCAT driver is now feature-complete end-to-end — read / write / discover / native-subscribe / probe / host-resolve, with poll-mode as a safety valve. Unblocks closing task #120 for TwinCAT; remaining sub-task: FOCAS + task #188 (symbol-browsing — lower priority than FOCAS since real config flows still use pre-declared tags).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 18:49:48 -04:00
a0112ddb43 Merge pull request (#122) - TwinCAT capabilities 2026-04-19 18:38:44 -04:00
Joseph Doherty
aeb28cc8e7 TwinCAT PR 3 — ITagDiscovery + ISubscribable + IHostConnectivityProbe + IPerCallHostResolver. Completes the TwinCAT driver — 7-interface capability set matching AbCip / AbLegacy (minus IAlarmSource, same deferral). ITagDiscovery emits pre-declared tags under TwinCAT/device-host folder with DeviceName fallback to HostAddress; Writable→Operate / non-writable→ViewOnly. Symbol-browsing via AdsClient.ReadSymbolsAsync / ReadSymbolInfoAsync deferred to a follow-up (same shape as the @tags deferral for AbCip — needs careful traversal of the TwinCAT symbol table + type graph which the ReadSymbolsAsync API does expose but adds enough scope to warrant its own PR). ISubscribable consumes the shared PollGroupEngine — 4th consumer after Modbus + AbCip + AbLegacy. TwinCAT supports native ADS notifications (AddDeviceNotification) which would be strictly superior to polling, but plumbing through OPC UA semantics + the PollGroupEngine abstraction would require a parallel sampling path; poll-first matches the cross-driver pattern + gets the driver shippable. Follow-up task for native-notification upgrade tracked after merge. IHostConnectivityProbe — per-device probe loop using ITwinCATClient.ProbeAsync which wraps AdsClient.ReadStateAsync (cheap handshake that returns the target's AdsState, succeeds when router + target both respond). Success transitions to Running, any exception or probe-false to Stopped. Same lazy-connect + dispose-on-failure pattern as the read/write path — device state reconnects cleanly after a transient. IPerCallHostResolver maps tag full-ref to DeviceHostAddress for Phase 6.1 (DriverInstanceId, ResolvedHostName) bulkhead/breaker keying per plan decision #144; unknown refs fall back to first device, no devices → DriverInstanceId. ShutdownAsync disposes PollGroupEngine + cancels/disposes every probe CTS + disposes every cached client. DeviceState extended with ProbeLock / HostState / HostStateChangedUtc / ProbeCts matching AbCip/AbLegacy shape. 10 new tests in TwinCATCapabilityTests — discovery tag emission with correct SecurityClassification, subscription initial poll raises OnDataChange, shutdown cancels subscriptions, GetHostStatuses entry-per-device, probe Running transition on ProbeResult=true, probe Stopped on ProbeResult=false, probe disabled when Enabled=false, ResolveHost for known/unknown/no-devices paths. Total TwinCAT unit tests now 85/85 passing (+10 from PR 2's 75); full solution builds 0 errors; other drivers untouched. TwinCAT driver complete end-to-end — any TC2/TC3 AMS target reachable through a router is now shippable with read/write/discover/subscribe/probe/host-resolve, feature-parity with AbCip/AbLegacy.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 18:36:55 -04:00
2d5aaf1eda Merge pull request (#121) - TwinCAT R/W 2026-04-19 18:34:52 -04:00
Joseph Doherty
28e3470300 TwinCAT PR 2 — IReadable + IWritable. ITwinCATClient + ITwinCATClientFactory abstraction — one client per AMS target, reused across reads/writes/probes. Shape differs from AbCip/AbLegacy where libplctag handles are per-tag — TwinCAT's AdsClient is a single connection with symbolic reads/writes issued against it, so the abstraction is coarser. AdsTwinCATClient is the default implementation wrapping Beckhoff.TwinCAT.Ads's AdsClient — ConnectAsync calls AdsClient.Connect(AmsNetId.Parse(netId), port) after setting Timeout in ms; ReadValueAsync dispatches TwinCATDataType to the CLR Type via MapToClrType (bool/sbyte/byte/short/ushort/int/uint/long/ulong/float/double/string/uint for time types) and calls AdsClient.ReadValueAsync(symbol, type, ct) which returns ResultAnyValue; unwraps .Value + .ErrorCode and maps non-NoError codes via TwinCATStatusMapper.MapAdsError. BOOL-within-word reads extract the bit after the underlying word read using ExtractBit over short/ushort/int/uint/long/ulong. WriteValueAsync converts the boxed value via ConvertForWrite (Convert.ToXxx per type) then calls AdsClient.WriteValueAsync returning ResultWrite; checks .ErrorCode for status mapping. BOOL-within-word writes throw NotSupportedException with a pointer to task #181 — same RMW gap as Modbus BitInRegister / AbCip BOOL-in-DINT / AbLegacy bit-within-N-file. ProbeAsync calls AdsClient.ReadStateAsync + checks AdsErrorCode.NoError. TwinCATDriver implements IReadable + IWritable — per-device ITwinCATClient cached in DeviceState.Client, lazy-connected on first read/write via EnsureConnectedAsync, connect-failure path disposes + clears the client so next call re-attempts cleanly. ReadAsync ordered-snapshot pattern matching AbCip/AbLegacy: unknown ref → BadNodeIdUnknown, unknown device → BadNodeIdUnknown, OperationCanceledException rethrow, any other exception → BadCommunicationError + Degraded health. WriteAsync similar — non-Writable tag → BadNotWritable upfront, NotSupportedException → BadNotSupported, FormatException/InvalidCastException (guard pattern) → BadTypeMismatch, OverflowException → BadOutOfRange, generic → BadCommunicationError. Symbol name resolution goes through TwinCATSymbolPath.TryParse(def.SymbolPath) with fallback to the raw def.SymbolPath if the path doesn't parse — the Beckhoff AdsClient handles the final validation at wire time. ShutdownAsync disposes each device's client. 14 new unit tests in TwinCATReadWriteTests using FakeTwinCATClient + FakeTwinCATClientFactory — unknown ref → BadNodeIdUnknown, successful DInt read with Good status + captured value + IsConnected=true after EnsureConnectedAsync, repeat reads reuse the connection (one Connect + multiple reads), ADS error code mapping via FakeTwinCATClient.ReadStatuses, read exception → BadCommunicationError + Degraded health, connect exception disposes the client, batched reads preserve order across DInt/Real/String types, non-Writable rejection, successful write logs symbol+type+value+bit for test inspection, write status-code mapping, write exception → BadCommunicationError, batch preserves order across success/non-writable/unknown, cancellation propagation, ShutdownAsync disposes the client. Total TwinCAT unit tests now 75/75 passing (+14 from PR 1's 61); full solution builds 0 errors; Modbus / AbCip / AbLegacy / other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 18:33:03 -04:00
bffac4db65 Merge pull request (#120) - TwinCAT scaffolding 2026-04-19 18:28:19 -04:00
Joseph Doherty
cd2c0bcadd TwinCAT PR 1 — Scaffolding + Core (TwinCATDriver + AMS address + symbolic path). New Driver.TwinCAT project referencing Beckhoff.TwinCAT.Ads 7.0.172 (the official Beckhoff .NET client — 1.6M+ downloads, actively maintained by Beckhoff + community). Package compiles without a local AMS router; wire calls need a running router (TwinCAT XAR on dev Windows, or the standalone Beckhoff.TwinCAT.Ads.TcpRouter embedded package for headless/CI). Same Core.Abstractions-only project shape as Modbus / AbCip / AbLegacy. TwinCATAmsAddress parses ads://{netId}:{port} canonical form — NetId is 6 dot-separated octets (NOT an IP; AMS router translates), port defaults to 851 (TC3 PLC runtime 1). Validates octet range 0-255 and port 1-65535. Case-insensitive scheme. Default-port stripping in canonical form for roundtrip stability. Rejects wrong scheme, missing //, 5-or-7-octet NetId, out-of-range octets/ports, non-numeric fragments. TwinCATSymbolPath handles IEC 61131-3 symbolic names — single-segment (Counter), POU.variable (MAIN.bStart), GVL.variable (GVL.Counter), structured member access (Motor1.Status.Running), array subscripts (Data[5]), multi-dim arrays (Matrix[1,2]), bit-access (Flags.3, GVL.Status.7), combined scope/member/subscript/bit (MAIN.Motors[0].Status.5). Roundtrip-safe ToAdsSymbolName produces the exact string AdsClient.ReadValue consumes. Rejects leading/trailing dots, space in idents, digit-prefix idents, empty/negative/non-numeric subscripts, unbalanced brackets. Underscore-prefix idents accepted per IEC. TwinCATDataType — BOOL / SINT / USINT / INT / UINT / DINT / UDINT / LINT / ULINT / REAL / LREAL / STRING / WSTRING (UTF-16) / TIME / DATE / DateTime (DT) / TimeOfDay (TOD) / Structure. Wider than Logix's surface — IEC adds WSTRING + TIME/DATE/DT/TOD variants. ToDriverDataType widens unsigned + 64-bit to Int32 matching the Modbus/AbCip/AbLegacy Int64-gap convention. TwinCATStatusMapper — Good / BadInternalError / BadNodeIdUnknown / BadNotWritable / BadOutOfRange / BadNotSupported / BadDeviceFailure / BadCommunicationError / BadTimeout / BadTypeMismatch. MapAdsError covers the ADS error codes a driver actually encounters — 6/7 port unreachable, 1792 service not supported, 1793/1794 invalid index group/offset, 1798 symbol not found (→ BadNodeIdUnknown), 1807 invalid state, 1808 access denied (→ BadNotWritable), 1811/1812 size mismatch (→ BadOutOfRange), 1861 sync timeout, unknown → BadCommunicationError. TwinCATDriverOptions + TwinCATDeviceOptions + TwinCATTagDefinition + TwinCATProbeOptions — one instance supports N AMS targets, Tags cross-key by HostAddress, Probe defaults to 5s interval (unlike AbLegacy there's no default probe address — ADS probe reads AmsRouterState not a user tag, so probe address is implicit). TwinCATDriver IDriver skeleton — InitializeAsync parses each device HostAddress + fails fast on malformed strings → Faulted. 61 new unit tests across 3 files — TwinCATAmsAddressTests (6 valid shapes + 12 invalid shapes + 2 ToString canonicalisation + roundtrip stability), TwinCATSymbolPathTests (9 valid shapes + 12 invalid shapes + underscore prefix + 8-case roundtrip), TwinCATDriverTests (DriverType + multi-device init + malformed-address fault + shutdown + reinit + data-type mapping theory + ADS error-code theory). Total project count 30 src + 19 tests; full solution builds 0 errors; Modbus / AbCip / AbLegacy / other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 18:26:29 -04:00
7fdf4e5618 Merge pull request (#119) - AbLegacy capabilities 2026-04-19 18:04:42 -04:00
Joseph Doherty
400fc6242c AB Legacy PR 3 — ITagDiscovery + ISubscribable + IHostConnectivityProbe + IPerCallHostResolver. Fills out the AbLegacy capability surface — the driver now implements the same 7-interface set as AbCip (IDriver + IReadable + IWritable + ITagDiscovery + ISubscribable + IHostConnectivityProbe + IPerCallHostResolver). ITagDiscovery emits pre-declared tags under an AbLegacy root folder with a per-device sub-folder keyed on HostAddress (DeviceName fallback to HostAddress when null). Writable tags surface as SecurityClassification.Operate, non-writable as ViewOnly. No controller-side enumeration — PCCC has no @tags equivalent on SLC / MicroLogix / PLC-5 (symbol table isn't exposed the way Logix exposes it), so the pre-declared path is the only discovery mechanism. ISubscribable consumes the shared PollGroupEngine extracted in AB CIP PR 1 — reader delegate points at ReadAsync (already handles lazy runtime init + caching), onChange bridges into the driver's OnDataChange event. 100ms interval floor. Initial-data push on first poll. Makes AbLegacy the third consumer of PollGroupEngine (after Modbus and AbCip). IHostConnectivityProbe — per-device probe loop when ProbeOptions.Enabled + ProbeAddress configured (defaults to S:0 status file word 0). Lazy-init on first tick, re-init on wire failure (destroyed native handle gets recreated rather than silently staying broken). Success transitions device to Running, exception to Stopped, same-state spurious event guard under per-device lock. GetHostStatuses returns one entry per device with current state + last-change timestamp for Admin /hosts surfacing. IPerCallHostResolver maps tag full-ref → DeviceHostAddress for the Phase 6.1 (DriverInstanceId, ResolvedHostName) bulkhead/breaker keying per plan decision #144. Unknown refs fall back to first device's address (invoker handles at capability level as BadNodeIdUnknown); no devices → DriverInstanceId. ShutdownAsync cancels + disposes each probe CTS, disposes PollGroupEngine cancelling active subscriptions, disposes every cached runtime. DeviceState gains ProbeLock / HostState / HostStateChangedUtc / ProbeCts / ProbeInitialized matching AbCip's DeviceState shape. 10 new unit tests in AbLegacyCapabilityTests covering — pre-declared tags emit under AbLegacy/device folder with correct SecurityClassification, subscription initial poll raises OnDataChange with correct value, unsubscribe halts polling (value change post-unsub produces no further events), GetHostStatuses returns one entry per device, probe Running transition on successful read, probe Stopped transition on read exception, probe disabled when ProbeAddress null, ResolveHost returns declared device for known tag, falls back to first device for unknown, falls back to DriverInstanceId when no devices. Total AbLegacy unit tests now 92/92 passing (+10 from PR 2's 82); full solution builds 0 errors; AbCip + Modbus + other drivers untouched. AB Legacy driver now complete end-to-end — SLC 500 / MicroLogix / PLC-5 / LogixPccc all shippable with read / write / discovery / subscribe / probe / host-resolve, feature-parity with AbCip minus IAlarmSource (same deferral per plan).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 18:02:52 -04:00
4438fdd7b1 Merge pull request (#118) - AbLegacy R/W 2026-04-19 18:00:27 -04:00
Joseph Doherty
b2424a0616 AB Legacy PR 2 — IReadable + IWritable. IAbLegacyTagRuntime + IAbLegacyTagFactory abstraction mirrors IAbCipTagRuntime from AbCip PR 3. LibplctagLegacyTagRuntime default implementation wraps libplctag.Tag with Protocol=ab_eip + PlcType dispatched from the profile's libplctag attribute (Slc500/MicroLogix/Plc5/LogixPccc) — libplctag routes PCCC-over-EIP internally based on PlcType, so our layer just forwards the atomic type to Get/Set calls. DecodeValue handles Bit (GetBit when bitIndex is set, else GetInt8!=0), Int/AnalogInt (GetInt16 widened to int), Long (GetInt32), Float (GetFloat32), String (GetString), TimerElement/CounterElement/ControlElement (GetInt32 — sub-element selection is in the libplctag tag name like T4:0.ACC, PLC-side decode picks the right slot). EncodeValue handles the same types; bit-within-word writes throw NotSupportedException pointing at follow-up task #181 (same read-modify-write gap as Modbus BitInRegister). AbLegacyDriver implements IReadable + IWritable with the exact same shape as AbCip PR 3-4 — per-tag lazy runtime init via EnsureTagRuntimeAsync cached in DeviceState.Runtimes dict, ordered-snapshot results, health surface updates. Exception table — OperationCanceledException rethrows, NotSupportedException → BadNotSupported, FormatException/InvalidCastException → BadTypeMismatch (guard pattern C# 11 syntax), OverflowException → BadOutOfRange, anything else → BadCommunicationError. ShutdownAsync disposes every cached runtime so the native tag handles get released. 14 new unit tests in AbLegacyReadWriteTests covering unknown ref → BadNodeIdUnknown, successful N-file read with Good status + captured value, repeat-read reuses cached runtime (init count 1 across 2 reads), libplctag non-zero status mapping (-14 → BadNodeIdUnknown), read exception → BadCommunicationError + Degraded health, batched reads preserve order across N/F/ST types, TagCreateParams composition (gateway/port/path/slc500 attribute/tag-name), non-writable tag → BadNotWritable, successful write encodes + flushes, bit-within-word → BadNotSupported (RmwThrowingFake mirrors LibplctagLegacyTagRuntime's runtime check), write exception → BadCommunicationError, batch preserves order across success+fail+unknown, cancellation propagates, ShutdownAsync disposes runtimes. Total AbLegacy unit tests now 82/82 passing (+14 from PR 1's 68). Full solution builds 0 errors; Modbus + AbCip + other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:58:38 -04:00
59c99190c6 Merge pull request (#117) - AbLegacy scaffolding 2026-04-19 17:56:15 -04:00
Joseph Doherty
fc575e8dae AB Legacy PR 1 — Scaffolding + Core (AbLegacyDriver + PCCC address parser). New Driver.AbLegacy project with the libplctag 1.5.2 reference + the same Core.Abstractions-only project shape AbCip uses. AbLegacyHostAddress duplicates the ab://gateway[:port]/cip-path parser from AbCip since PCCC-over-EIP uses the same gateway routing convention (SLC 500 direct-wired with empty path, PLC-5 bridged through a ControlLogix chassis with full CIP path). Parser is 30 lines; copy was cheaper than introducing a shared Ab* project just to avoid duplication. AbLegacyAddress handles PCCC file addressing — file-letter + optional file-number + colon + word-number + optional sub-element (.ACC / .PRE / .EN / .DN / .CU / .CD / .LEN / .POS / .ER) + optional /bit-index. Handles the full shape variety — N7:0 (integer file 7 word 0), F8:5 (float file 8 word 5), B3:0/0 (bit file 3 word 0 bit 0), ST9:0 (string file 9 string 0), L9:3 (long file SLC 5/05+), T4:0.ACC (timer accumulator), C5:2.CU (counter count-up bit), R6:0.LEN (control length), I:0/0 (input file bit — no file number for I/O/S), O:1/2 (output file bit), S:1 (status file word), N7:0/3 (bit within integer file). Validates file letters against the canonical SLC/ML/PLC-5 set (N/F/B/L/ST/T/C/R/I/O/S/A). ToLibplctagName roundtrips so the parsed value can be handed straight to libplctag's name= attribute. AbLegacyDataType — Bit / Int (N-file, 16-bit signed) / Long (L-file, 32-bit, SLC 5/05+ only) / Float (F-file, 32-bit IEEE-754) / AnalogInt (A-file) / String (ST-file, 82-byte fixed + length word) / TimerElement / CounterElement / ControlElement. ToDriverDataType widens Long to Int32 matching the Modbus/AbCip Int64-gap convention. AbLegacyStatusMapper shares the OPC UA status constants with AbCip (same numeric values, different namespace). MapLibplctagStatus mirrors AbCip — 0 success, positive pending, negative error code families. MapPcccStatus handles PCCC STS bytes — 0x00 success, 0x10 illegal command, 0x20 bad address, 0x30 protected, 0x40/0x50 busy, 0xF0 extended status. AbLegacyDriverOptions + AbLegacyDeviceOptions + AbLegacyTagDefinition + AbLegacyProbeOptions mirror AbCip shapes — one instance supports N devices via Devices list, Tags list references devices by HostAddress cross-key, Probe uses S:0 by default as the cheap probe address. AbLegacyPlcFamilyProfile for four families — Slc500 (slc500 attribute, 1,0 default path, supports L + ST files, 240B max PCCC packet), MicroLogix (micrologix attribute, empty path for direct EIP, supports ST but not L), Plc5 (plc5 attribute, 1,0 default path, supports ST but predates L), LogixPccc (logixpccc attribute, full Logix ConnectionSize + L file support via the PCCC compatibility layer on ControlLogix). AbLegacyDriver implements IDriver only — InitializeAsync parses each device's HostAddress and selects its profile (fails fast on malformed strings → Faulted health), per-device state with parsed address + options + profile + empty placeholder for PRs 2-3. ShutdownAsync clears the device dict. 68 new unit tests across 3 files — AbLegacyAddressTests (15 valid shapes + 10 invalid shapes + 7 ToLibplctagName roundtrip), AbLegacyHostAndStatusTests (4 valid host + 5 invalid host + 8 PCCC STS + 7 libplctag status), AbLegacyDriverTests (IDriver lifecycle + multi-device init with per-family profile selection + malformed-address fault + shutdown + family profile defaults + ForFamily theory + data-type mapping). Total project count 29 src + 18 tests; full solution builds 0 errors; Modbus + AbCip + other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:54:25 -04:00
70f5f2cad1 Merge pull request (#116) - AbCip family profiles 2026-04-19 17:20:43 -04:00
Joseph Doherty
60b8d6f2d0 AB CIP PR 9-12 — Per-PLC-family profile tests + GuardLogix safety-tag support. Consolidates PRs 9/10/11/12 from the plan (ControlLogix / CompactLogix / Micro800 / GuardLogix integration suites) into a single PR because the per-family work that actually ships without a live ab_server binary is profile-metadata assertion + unit-level driver-option binding. Per-family integration tests that require a running simulator are deferred to the ab_server-CI follow-up already tracked from PR 3 (download prebuilt Windows binary as GitHub release asset). ControlLogix — baseline profile asserted (controllogix attribute, 4002 LFO ConnectionSize, 1,0 default path, request-packing + connected-messaging, 4000B max fragment). CompactLogix — narrower 504 ConnectionSize for 5069-L3x safety, 500B max fragment, lib attribute compactlogix which libplctag maps to the ControlLogix family internally but via our profile chain we surface it as a distinct knob so future quirk handling (5069 narrow-window regression cases) hangs off the compactlogix attribute. Micro800 — empty CIP path for no-backplane routing, 488B ConnectionSize, 484B fragment cap, request packing + connected messaging both disabled (most models reject Forward_Open), micro800 lib attribute. Test asserts the driver correctly parses an ab://192.168.1.20/ host address with empty path + forwards the empty path through AbCipTagCreateParams so libplctag sees the unconnected-only configuration. GuardLogix — wire protocol identical to ControlLogix (safety partition is a per-tag concern, not a wire-layer distinction) so profile defaults match ControlLogix. New AbCipTagDefinition.SafetyTag field — when true, the driver forces SecurityClassification.ViewOnly in discovery regardless of the Writable flag, and IWritable rejects the write upfront with BadNotWritable. Matches the Rockwell safety-partition isolation model where non-safety-task writes to safety tags would be rejected by the PLC anyway — surfacing the intent at the driver surface prevents wasted wire round-trips + gives Admin UI users a correct ViewOnly rendering. 14 new unit tests in AbCipPlcFamilyTests covering — ControlLogix profile defaults + correct profile selection at Initialize, CompactLogix narrower-than-ControlLogix ConnectionSize + fragment cap, Micro800 empty path parses + SupportsConnectedMessaging=false + SupportsRequestPacking=false + read forwards empty path + micro800 attribute through to libplctag, GuardLogix wire-protocol parity with ControlLogix, GuardLogix safety tag surfaces as ViewOnly in discovery even when Writable=true, GuardLogix safety-tag write rejected with BadNotWritable even when Writable=true, ForFamily theory (4 families → correct libplctag attribute). Total AbCip unit tests now 161/161 passing (+14 from PR 8's 147). Modbus + other drivers untouched; full solution builds 0 errors. PR 13 (IAlarmSource via tag-projected ALMA/ALMD blocks) remains deferred per the plan — feature-flagged pattern not needed before go-live.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:18:51 -04:00
30f971599e Merge pull request (#115) - AbCip host probe + resolver 2026-04-19 17:16:59 -04:00
Joseph Doherty
ac14ba9664 AB CIP PR 8 — IHostConnectivityProbe + IPerCallHostResolver. Per-device probe loop — when AbCipProbeOptions.Enabled + ProbeTagPath are configured, InitializeAsync kicks off one probe task per device that periodically reads the probe tag (lazy-init on first attempt, re-init on wire failure so destroyed native handles get recreated rather than silently staying broken), transitions Running on status==0 or Stopped on non-zero status / exception, raises OnHostStatusChanged with the device HostAddress as the host-name key. TransitionDeviceState guards against spurious same-state events under a per-device lock. ShutdownAsync cancels + disposes each probe's CTS + its captured runtime. DeviceState record gains ProbeLock / HostState / HostStateChangedUtc / ProbeCts / ProbeInitialized fields. IHostConnectivityProbe.GetHostStatuses returns one HostConnectivityStatus per device with the current state + last-change timestamp, surfaced to Admin /hosts per plan decision #144. IPerCallHostResolver.ResolveHost maps a tag full-reference to its DeviceHostAddress via the _tagsByName dict populated at Initialize time, which means UDT member full-references (Motor1.Speed synthesised by PR 6) resolve to the parent UDT's device without extra bookkeeping. Unknown references fall back to the first configured device's host address (invoker handles the actual mislookup at read time as BadNodeIdUnknown), and when no devices are configured resolver returns DriverInstanceId so the single-host fallback pipeline still works. Matches the plan decision #144 contract — Phase 6.1 resilience keys its bulkhead + breaker on (DriverInstanceId, ResolvedHostName) so a dead PLC trips only its own breaker, healthy siblings keep serving. 10 new unit tests in AbCipHostProbeTests covering GetHostStatuses returning one entry per device, probe success transitioning Unknown → Running, probe exception transitioning to Stopped, Enabled=false skipping the loop (no events + state stays Unknown), null ProbeTagPath skipping the loop, multi-device independent probe behavior (one Running + one Stopped simultaneously), ResolveHost for known tags returning the declared DeviceHostAddress, ResolveHost for unknown ref falling back to first device, ResolveHost falling back to DriverInstanceId when no devices, ResolveHost for UDT member walking to the synthesised member definition. Total AbCip unit tests now 147/147 passing (+10 from PR 7's 137). Full solution builds 0 errors; Modbus + other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:15:10 -04:00
5978ea002d Merge pull request (#114) - AbCip ISubscribable 2026-04-19 17:13:41 -04:00
Joseph Doherty
33780eb64c AB CIP PR 7 — ISubscribable via shared PollGroupEngine. AbCipDriver now implements ISubscribable — Subscribe delegates into the PollGroupEngine extracted in PR 1, Unsubscribe releases the subscription, ShutdownAsync disposes the engine cancelling every active subscription. OnDataChange event wired through the engine's on-change callback so external subscribers see the driver as sender. The engine's reader delegate points at the driver's ReadAsync (already handles lazy runtime init + caching via EnsureTagRuntimeAsync) — each poll tick batch-reads every subscribed tag in one IReadable call. 100ms interval floor inherited from PollGroupEngine.DefaultMinInterval matches Modbus convention. Initial-data push on first poll preserved via forceRaise=true. Exception-tolerant loop preserved — individual read failures show up as DataValueSnapshot with non-Good StatusCode via the status-code mapping PR 3 established. 7 new unit tests in AbCipSubscriptionTests covering initial-poll raising per tag, unchanged value raising only once, value change between polls triggering a new event, Unsubscribe halting the loop, 100ms floor keeping a 5ms request from generating extra events against a stable value, ShutdownAsync cancelling active subscriptions, UDT member subscription routing through the synthesised Motor1.Speed full-reference (proving PR 6's fan-out composes correctly with PR 7's subscription path). Total AbCip unit tests now 137/137 passing (+7 from PR 6's 130). Validates that the shared PollGroupEngine from PR 1 works correctly for a second driver, closing the original motivation for the extraction. Full solution builds 0 errors; Modbus + other drivers untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:11:51 -04:00
521bcb2f68 Merge pull request (#113) - AbCip UDT members 2026-04-19 17:11:08 -04:00
Joseph Doherty
b06a1ba607 AB CIP PR 6 — UDT member-declaration support. Declaration-driven UDT member fan-out — users declare a UDT-typed tag once with an explicit Members list and the driver (1) expands member-addressable tags synthetically at Initialize time so Read/Write/Subscribe hit individual native tags per member, (2) emits a folder + one Variable per member in DiscoverAsync instead of a single opaque Structure Variable. Matches the Logix 5000 addressing convention where members are reached via dotted syntax (Motor1.Speed, Motor1.Running) — AbCipTagPath already parsed this shape in PR 2, so PR 6 just had to wire config→TagPath composition. New AbCipStructureMember record — Name / DataType / Writable / WriteIdempotent — plus optional Members list on AbCipTagDefinition that's ignored for atomic types and optional for Structure types. When Structure has null or empty Members the driver falls back to emitting a single opaque Variable so downstream config can address members manually (the "black box" path documented in AbCipTagDefinition's docstring). AbCipDriver.InitializeAsync now iterates tags + for every Structure tag with non-empty Members synthesises a child AbCipTagDefinition per member (composed full-reference Parent.Member + composed TagPath parent.member passed through to libplctag as a normal symbolic read). Per-member Writable/WriteIdempotent metadata propagates so IWritable correctly rejects writes to members flagged non-writable even when the parent tag is writable — each member stands alone from the resilience + authz perspective. DiscoverAsync gains a matching branch — Structure with Members emits an intermediate folder named after the parent tag + one Variable per member under it (browse name = member.Name, FullName = Parent.Member). Members with Writable=false surface SecurityClassification.ViewOnly, WriteIdempotent flag passes through to the DriverAttributeInfo. Structure without Members falls through to the normal single-Variable path. Whole-UDT read optimization (one libplctag call returns the packed buffer + client-side member decode) is deferred — needs the CIP Template Object class 0x6C reader which is blocked on the same libplctag 1.5.2 TagInfoPlcMapper gap that deferred the real @tags walker in PR 5. AbCipTemplateCache shipped in PR 5 is the drop-in point when that reader lands. Per-member reads today are N native round-trips; whole-UDT optimisation is a perf win, not a correctness gap. 7 new unit tests in AbCipUdtMemberTests — UDT fan-out to Variable children under folder with correct SecurityClassification + WriteIdempotent propagation, member reads via synthesised full-reference with correct per-member values, member writes routing to correct TagPath, member Writable=false flag correctly blocking IWritable, Structure without Members falls back to single Variable, empty Members list treated identically to null, UDT tags coexist with flat tags in the discovery output. Total AbCip unit tests now 130/130 passing (+7 from PR 5's 123). Modbus + other drivers untouched; full solution builds 0 errors. Unblocks PR 7 (ISubscribable) — the poll engine already works with member-level full references.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:09:06 -04:00
dd1389a8e7 Merge pull request (#112) - AbCip ITagDiscovery 2026-04-19 17:07:03 -04:00