dohertj2 dohertj2
  • Joined on 2026-02-20
dohertj2 created pull request dohertj2/lmxopcua#17 2026-04-18 08:41:47 -04:00
Phase 3 PR 18 — delete v1 archived projects
dohertj2 created branch phase-3-pr18-delete-v1 in dohertj2/lmxopcua 2026-04-18 08:36:53 -04:00
dohertj2 pushed to phase-3-pr18-delete-v1 at dohertj2/lmxopcua 2026-04-18 08:36:53 -04:00
dd3a449308 Phase 3 PR 18 — delete v1 archived projects. PR 2 archived via IsTestProject=false + PropertyGroup comment; PR 17 landed the full v2 OPC UA server runtime (ApplicationConfiguration + endpoint + client integration test); every v1 surface is now functionally superseded. This PR removes the archive: 154 files across 5 projects — src/OtOpcUa.Host (v1 server, 158 files), src/Historian.Aveva (v1 historian plugin, 4 files), tests/OtOpcUa.Tests.v1Archive (494 unit tests that were archived in PR 2 with IsTestProject=false), tests/Historian.Aveva.Tests (18 tests against the v1 plugin), tests/OtOpcUa.IntegrationTests (6 tests against the v1 Host). slnx trimmed to reflect the current set (12 src + 12 tests). Verified zero incoming references from live projects before deleting — no live csproj references .Host or .Historian.Aveva since PR 5 ported Historian into Driver.Galaxy.Host/Backend/Historian/ and PR 17 stood up the new OtOpcUa.Server. Full solution post-delete: 0 errors, 165 unit + integration tests pass (8 Core + 14 Proxy + 24 Configuration + 91 Galaxy.Host + 6 Shared + 4 Server + 18 Admin) — no regressions. Recovery path if a future PR needs to resurrect a specific v1 routine: git revert this commit or cherry-pick the specific file from pre-delete history; v1 is preserved in the full branch history, not lost.
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 08:28:44 -04:00
3c1dc334f9 Merge pull request 'Phase 3 PR 17 — complete OPC UA server startup + live integration test' (#16) from phase-3-pr17-server-startup into v2
46834a43bd Phase 3 PR 17 — complete OPC UA server startup end-to-end + integration test. PR 16 shipped the materialization shape (DriverNodeManager / OtOpcUaServer) without the activation glue; this PR finishes the scope so an external OPC UA client can actually connect, browse, and read. New OpcUaServerOptions DTO bound from the OpcUaServer section of appsettings.json (EndpointUrl default opc.tcp://0.0.0.0:4840/OtOpcUa, ApplicationName, ApplicationUri, PkiStoreRoot default %ProgramData%\OtOpcUa\pki, AutoAcceptUntrustedClientCertificates default true for dev — production flips via config). OpcUaApplicationHost wraps Opc.Ua.Configuration.ApplicationInstance: BuildConfiguration constructs the ApplicationConfiguration programmatically (no external XML) with SecurityConfiguration pointing at <PkiStoreRoot>/own, /issuers, /trusted, /rejected directories — stack auto-creates the cert folders on first run and generates a self-signed application certificate via CheckApplicationInstanceCertificate, ServerConfiguration.BaseAddresses set to the endpoint URL + SecurityPolicies just None + UserTokenPolicies just Anonymous with PolicyId='Anonymous' + SecurityPolicyUri=None so the client's UserTokenPolicy lookup succeeds at OpenSession, TransportQuotas.OperationTimeout=15s + MinRequestThreadCount=5 / MaxRequestThreadCount=100 / MaxQueuedRequestCount=200, CertificateValidator auto-accepts untrusted when configured. StartAsync creates the OtOpcUaServer (passes DriverHost + ILoggerFactory so one DriverNodeManager is created per registered driver in CreateMasterNodeManager from PR 16), calls ApplicationInstance.Start(server) to bind the endpoint, then walks each DriverNodeManager and drives a fresh GenericDriverNodeManager.BuildAddressSpaceAsync against it so the driver's discovery streams into the address space that's already serving clients. Per-driver discovery is isolated per decision #12: a discovery exception marks the driver's subtree faulted but the server stays up serving the other drivers' subtrees. DriverHost.GetDriver(instanceId) public accessor added alongside the existing GetHealth so OtOpcUaServer can enumerate drivers during CreateMasterNodeManager. DriverNodeManager.Driver property made public so OpcUaApplicationHost can identify which driver each node manager wraps during the discovery loop. OpcUaServerService constructor takes OpcUaApplicationHost — ExecuteAsync sequence now: bootstrap.LoadCurrentGenerationAsync → applicationHost.StartAsync → infinite Task.Delay until stop. StopAsync disposes the application host (which stops the server via OtOpcUaServer.Stop) before disposing DriverHost. Program.cs binds OpcUaServerOptions from appsettings + registers OpcUaApplicationHost + OpcUaServerOptions as singletons. Integration test (OpcUaServerIntegrationTests, Category=Integration): IAsyncLifetime spins up the server on a random non-default port (48400+random for test isolation) with a per-test-run PKI store root (%temp%/otopcua-test-<guid>) + a FakeDriver registered in DriverHost that has ITagDiscovery + IReadable implementations — DiscoverAsync registers TestFolder>Var1, ReadAsync returns 42. Client_can_connect_and_browse_driver_subtree creates an in-process OPC UA client session via CoreClientUtils.SelectEndpoint (which talks to the running server's GetEndpoints and fetches the live EndpointDescription with the actual PolicyId), browses the fake driver's root, asserts TestFolder appears in the returned references. Client_can_read_a_driver_variable_through_the_node_manager constructs the variable NodeId using the namespace index the server registered (urn:OtOpcUa:fake), calls Session.ReadValue, asserts the DataValue.Value is 42 — the whole pipeline (client → server endpoint → DriverNodeManager.OnReadValue → FakeDriver.ReadAsync → back through the node manager → response to client) round-trips correctly. Dispose tears down the session, server, driver host, and PKI store directory. Full solution: 0 errors, 165 tests pass (8 Core unit + 14 Proxy unit + 24 Configuration unit + 6 Shared unit + 91 Galaxy.Host unit + 4 Server (2 unit NodeBootstrap + 2 new integration) + 18 Admin). End-to-end outcome: PR 14's GalaxyAlarmTracker alarm events now flow through PR 15's GenericDriverNodeManager event forwarder → PR 16's ConditionSink → OPC UA AlarmConditionState.ReportEvent → out to every OPC UA client subscribed to the alarm condition. The full alarm subsystem (driver-side subscription of the Galaxy 4-attribute quartet, Core-side routing by source node id, Server-side AlarmConditionState materialization with ReportEvent dispatch) is now complete and observable through any compliant OPC UA client. LDAP / security-profile wire-up (replacing the anonymous-only endpoint with BasicSignAndEncrypt + user identity mapping to NodePermissions role) is the next layer — it reuses the same ApplicationConfiguration plumbing this PR introduces but needs a deployment-policy source (central config DB) for the cert trust decisions.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#16 2026-04-18 08:28:43 -04:00
Phase 3 PR 17 — complete OPC UA server startup + live integration test
dohertj2 created pull request dohertj2/lmxopcua#16 2026-04-18 08:28:41 -04:00
Phase 3 PR 17 — complete OPC UA server startup + live integration test
dohertj2 pushed to phase-3-pr17-server-startup at dohertj2/lmxopcua 2026-04-18 08:20:09 -04:00
46834a43bd Phase 3 PR 17 — complete OPC UA server startup end-to-end + integration test. PR 16 shipped the materialization shape (DriverNodeManager / OtOpcUaServer) without the activation glue; this PR finishes the scope so an external OPC UA client can actually connect, browse, and read. New OpcUaServerOptions DTO bound from the OpcUaServer section of appsettings.json (EndpointUrl default opc.tcp://0.0.0.0:4840/OtOpcUa, ApplicationName, ApplicationUri, PkiStoreRoot default %ProgramData%\OtOpcUa\pki, AutoAcceptUntrustedClientCertificates default true for dev — production flips via config). OpcUaApplicationHost wraps Opc.Ua.Configuration.ApplicationInstance: BuildConfiguration constructs the ApplicationConfiguration programmatically (no external XML) with SecurityConfiguration pointing at <PkiStoreRoot>/own, /issuers, /trusted, /rejected directories — stack auto-creates the cert folders on first run and generates a self-signed application certificate via CheckApplicationInstanceCertificate, ServerConfiguration.BaseAddresses set to the endpoint URL + SecurityPolicies just None + UserTokenPolicies just Anonymous with PolicyId='Anonymous' + SecurityPolicyUri=None so the client's UserTokenPolicy lookup succeeds at OpenSession, TransportQuotas.OperationTimeout=15s + MinRequestThreadCount=5 / MaxRequestThreadCount=100 / MaxQueuedRequestCount=200, CertificateValidator auto-accepts untrusted when configured. StartAsync creates the OtOpcUaServer (passes DriverHost + ILoggerFactory so one DriverNodeManager is created per registered driver in CreateMasterNodeManager from PR 16), calls ApplicationInstance.Start(server) to bind the endpoint, then walks each DriverNodeManager and drives a fresh GenericDriverNodeManager.BuildAddressSpaceAsync against it so the driver's discovery streams into the address space that's already serving clients. Per-driver discovery is isolated per decision #12: a discovery exception marks the driver's subtree faulted but the server stays up serving the other drivers' subtrees. DriverHost.GetDriver(instanceId) public accessor added alongside the existing GetHealth so OtOpcUaServer can enumerate drivers during CreateMasterNodeManager. DriverNodeManager.Driver property made public so OpcUaApplicationHost can identify which driver each node manager wraps during the discovery loop. OpcUaServerService constructor takes OpcUaApplicationHost — ExecuteAsync sequence now: bootstrap.LoadCurrentGenerationAsync → applicationHost.StartAsync → infinite Task.Delay until stop. StopAsync disposes the application host (which stops the server via OtOpcUaServer.Stop) before disposing DriverHost. Program.cs binds OpcUaServerOptions from appsettings + registers OpcUaApplicationHost + OpcUaServerOptions as singletons. Integration test (OpcUaServerIntegrationTests, Category=Integration): IAsyncLifetime spins up the server on a random non-default port (48400+random for test isolation) with a per-test-run PKI store root (%temp%/otopcua-test-<guid>) + a FakeDriver registered in DriverHost that has ITagDiscovery + IReadable implementations — DiscoverAsync registers TestFolder>Var1, ReadAsync returns 42. Client_can_connect_and_browse_driver_subtree creates an in-process OPC UA client session via CoreClientUtils.SelectEndpoint (which talks to the running server's GetEndpoints and fetches the live EndpointDescription with the actual PolicyId), browses the fake driver's root, asserts TestFolder appears in the returned references. Client_can_read_a_driver_variable_through_the_node_manager constructs the variable NodeId using the namespace index the server registered (urn:OtOpcUa:fake), calls Session.ReadValue, asserts the DataValue.Value is 42 — the whole pipeline (client → server endpoint → DriverNodeManager.OnReadValue → FakeDriver.ReadAsync → back through the node manager → response to client) round-trips correctly. Dispose tears down the session, server, driver host, and PKI store directory. Full solution: 0 errors, 165 tests pass (8 Core unit + 14 Proxy unit + 24 Configuration unit + 6 Shared unit + 91 Galaxy.Host unit + 4 Server (2 unit NodeBootstrap + 2 new integration) + 18 Admin). End-to-end outcome: PR 14's GalaxyAlarmTracker alarm events now flow through PR 15's GenericDriverNodeManager event forwarder → PR 16's ConditionSink → OPC UA AlarmConditionState.ReportEvent → out to every OPC UA client subscribed to the alarm condition. The full alarm subsystem (driver-side subscription of the Galaxy 4-attribute quartet, Core-side routing by source node id, Server-side AlarmConditionState materialization with ReportEvent dispatch) is now complete and observable through any compliant OPC UA client. LDAP / security-profile wire-up (replacing the anonymous-only endpoint with BasicSignAndEncrypt + user identity mapping to NodePermissions role) is the next layer — it reuses the same ApplicationConfiguration plumbing this PR introduces but needs a deployment-policy source (central config DB) for the cert trust decisions.
dohertj2 created branch phase-3-pr17-server-startup in dohertj2/lmxopcua 2026-04-18 08:20:08 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 08:10:47 -04:00
7683b94287 Merge pull request 'Phase 3 PR 16 — concrete OPC UA server scaffolding + AlarmConditionState materialization' (#15) from phase-3-pr16-opcua-server into v2
f53c39a598 Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#15 2026-04-18 08:10:46 -04:00
Phase 3 PR 16 — concrete OPC UA server scaffolding + AlarmConditionState materialization
dohertj2 created pull request dohertj2/lmxopcua#15 2026-04-18 08:10:36 -04:00
Phase 3 PR 16 — concrete OPC UA server scaffolding + AlarmConditionState materialization
dohertj2 created branch phase-3-pr16-opcua-server in dohertj2/lmxopcua 2026-04-18 08:02:08 -04:00
dohertj2 pushed to phase-3-pr16-opcua-server at dohertj2/lmxopcua 2026-04-18 08:02:08 -04:00
f53c39a598 Phase 3 PR 16 — concrete OPC UA server scaffolding with AlarmConditionState materialization. Introduces the OPCFoundation.NetStandard.Opc.Ua.Server package (v1.5.374.126, same version the v1 stack already uses) and two new server-side classes: DriverNodeManager : CustomNodeManager2 is the concrete realization of PR 15's IAddressSpaceBuilder contract — Folder() creates FolderState nodes under an Organizes hierarchy rooted at ObjectsFolder > DriverInstanceId; Variable() creates BaseDataVariableState with DataType mapped from DriverDataType (Boolean/Int32/Float/Double/String/DateTime) + ValueRank (Scalar or OneDimension) + AccessLevel CurrentReadOrWrite; AddProperty() creates PropertyState with HasProperty reference. Read hook wires OnReadValue per variable to route to IReadable.ReadAsync; Write hook wires OnWriteValue to route to IWritable.WriteAsync and surface per-tag StatusCode. MarkAsAlarmCondition() materializes an OPC UA AlarmConditionState child of the variable, seeded from AlarmConditionInfo (SourceName, InitialSeverity → UA severity via Low=250/Medium=500/High=700/Critical=900, InitialDescription), initial state Enabled + Acknowledged + Inactive + Retain=false. Returns an IAlarmConditionSink whose OnTransition updates alarm.Severity/Time/Message and switches state per AlarmType string ('Active' → SetActiveState(true) + SetAcknowledgedState(false) + Retain=true; 'Acknowledged' → SetAcknowledgedState(true); 'Inactive' → SetActiveState(false) + Retain=false if already Acked) then calls alarm.ReportEvent to emit the OPC UA event to subscribed clients. Galaxy's GalaxyAlarmTracker (PR 14) now lands at a concrete AlarmConditionState node instead of just raising an unobserved C# event. OtOpcUaServer : StandardServer wires one DriverNodeManager per DriverHost.GetDriver during CreateMasterNodeManager — anonymous endpoint, no security profile (minimum-viable; LDAP + security-profile wire-up is the next PR). DriverHost gains public GetDriver(instanceId) so the server can enumerate drivers at startup. NestedBuilder inner class in DriverNodeManager implements IAddressSpaceBuilder by temporarily retargeting the parent's _currentFolder during each call so Folder→Variable→AddProperty land under the correct subtree — not thread-safe if discovery ran concurrently, but GenericDriverNodeManager.BuildAddressSpaceAsync is sequential per driver so this is safe by construction. NuGet audit suppress for GHSA-h958-fxgg-g7w3 (moderate-severity in OPCFoundation.NetStandard.Opc.Ua.Core 1.5.374.126; v1 stack already accepts this risk on the same package version). PR 16 is scoped as scaffolding — the actual server startup (ApplicationInstance, certificate config, endpoint binding, session management wiring into OpcUaServerService.ExecuteAsync) is deferred to a follow-up PR because it needs ApplicationConfiguration XML + optional-cert-store logic that depends on per-deployment policy decisions. The materialization shape is complete: a subsequent PR adds 100 LOC to start the server and all the already-written IAddressSpaceBuilder + alarm-condition + read/write wire-up activates end-to-end. Full solution: 0 errors, 152 unit tests pass (no new tests this PR — DriverNodeManager unit testing needs an IServerInternal mock which is heavyweight; live-endpoint integration tests land alongside the server-startup PR).
dohertj2 merged pull request dohertj2/lmxopcua#14 2026-04-18 07:54:32 -04:00
Phase 3 PR 15 — alarm-condition contract in abstract layer
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 07:54:32 -04:00
d569c39f30 Merge pull request 'Phase 3 PR 15 — alarm-condition contract in abstract layer' (#14) from phase-3-pr15-alarm-contract into v2
190d09cdeb Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
Compare 2 commits »
dohertj2 created pull request dohertj2/lmxopcua#14 2026-04-18 07:54:19 -04:00
Phase 3 PR 15 — alarm-condition contract in abstract layer
dohertj2 created branch phase-3-pr15-alarm-contract in dohertj2/lmxopcua 2026-04-18 07:53:05 -04:00
dohertj2 pushed to phase-3-pr15-alarm-contract at dohertj2/lmxopcua 2026-04-18 07:53:05 -04:00
190d09cdeb Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 07:37:52 -04:00
4e0040e670 Merge pull request 'Phase 2 PR 14 — alarm subsystem (subscribe to alarm attribute quartet + raise GalaxyAlarmEvent)' (#13) from phase-2-pr14-alarm-subsystem into v2
c14624f012 Phase 2 PR 14 — alarm subsystem wire-up. Per IsAlarm=true attribute (PR 9 added the discovery flag), GalaxyAlarmTracker in Backend/Alarms/ advises the four Galaxy alarm-state attributes: .InAlarm (boolean alarm active), .Priority (int severity), .DescAttrName (human-readable description), .Acked (boolean acknowledged). Runs the OPC UA Part 9 alarm lifecycle state machine simplified for the Galaxy AlarmExtension model and raises AlarmTransition events on transitions operators must react to — Active (InAlarm false→true, default Unacknowledged), Acknowledged (Acked false→true while InAlarm still true), Inactive (InAlarm true→false). MxAccessGalaxyBackend instantiates the tracker in its constructor with delegate-based subscribe/unsubscribe/write pointers to MxAccessClient, hooks TransitionRaised to forward each transition through the existing OnAlarmEvent IPC event that PR 4 ConnectionSink wires into MessageKind.AlarmEvent frames — no new contract messages required since GalaxyAlarmEvent already exists in Shared.Contracts. Field mapping: EventId = fresh Guid.ToString('N') per transition, ObjectTagName = alarm attribute full reference, AlarmName = alarm attribute full reference, Severity = tracked Priority, StateTransition = 'Active'|'Acknowledged'|'Inactive', Message = DescAttrName or tag fallback, UtcUnixMs = transition time. DiscoverAsync caches every IsAlarm=true attribute's full reference (tag.attribute) into _discoveredAlarmTags (ConcurrentBag cleared-then-filled on every re-Discover to track Galaxy redeploys). SubscribeAlarmsAsync iterates the cache and advises each via GalaxyAlarmTracker.TrackAsync; best-effort per-alarm — a subscribe failure on one alarm doesn't abort the whole call since operators prefer partial alarm coverage to none. Tracker is internally idempotent on repeat Track calls (second invocation for same alarm tag is a no-op; already-subscribed check short-circuits before the 4 MXAccess sub calls). Subscribe-failure rollback inside TrackAsync removes the alarm state + unadvises any of the 4 that did succeed so a partial advise can't leak a phantom tracking entry. AcknowledgeAlarmAsync routes to tracker.AcknowledgeAsync which writes the operator comment to <tag>.AckMsg via MxAccessClient.WriteAsync — writes use the existing MXAccess OnWriteComplete TCS-by-handle path (PR 4 Medium 4) so a runtime-refused ack bubbles up as Success=false rather than false-positive. State-machine quirks preserved from v1: (1) initial Acked=true on subscribe does NOT fire Acknowledged (alarm at rest, pre-acknowledged — default state is Acked=true so the first subscribe callback is a no-op transition), (2) Acked false→true only fires Acknowledged when InAlarm is currently true (acking a latched-inactive alarm is not a user-visible transition), (3) Active transition clears the Acked flag in-state so the next Acked callback correctly fires Acknowledged (v1 had this buried in the ConditionState logic; we track it on the AlarmState struct directly). Priority value handled as int/short/long via type pattern match with int.MaxValue guard — Galaxy attribute category returns varying CLR types (Int32 is canonical but some older templates use Int16), and a long overflow cast to int would silently corrupt the severity. Dispose cascade in MxAccessGalaxyBackend.Dispose: alarm-tracker unsubscribe→dispose, probe-manager unsubscribe→dispose, mx.ConnectionStateChanged detach, historian dispose — same discipline PR 6 / PR 8 / PR 13 established so dangling invocation-list refs don't survive a backend recycle. #pragma warning disable CS0067 around OnAlarmEvent removed since the event is now raised. Tests (9 new, GalaxyAlarmTrackerTests): four-attribute subscribe per alarm, idempotent repeat-track, InAlarm false→true fires Active with Priority + Desc, InAlarm true→false fires Inactive, Acked false→true while InAlarm fires Acknowledged, Acked transition while InAlarm=false does not fire, AckMsg write path carries the comment, snapshot reports latest four fields, foreign probe callback for a non-tracked tag is silently dropped. Full Galaxy.Host.Tests Unit suite 84 pass / 0 fail (9 new alarm + 12 PR 13 probe + 21 PR 12 quality + 42 pre-existing). Galaxy.Host builds clean (0/0). Branches off phase-2-pr13-runtime-probe so the MxAccessGalaxyBackend constructor/Dispose chain gets the probe-manager + alarm-tracker wire-up in a coherent order; fast-forwards if PR 13 merges first.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#13 2026-04-18 07:37:50 -04:00
Phase 2 PR 14 — alarm subsystem (subscribe to alarm attribute quartet + raise GalaxyAlarmEvent)