dohertj2 merged pull request dohertj2/lmxopcua#52 2026-04-18 22:35:42 -04:00
Phase 3 PR 53 -- Transport reconnect-on-drop + SO_KEEPALIVE (DL260 no-keepalive quirk)
dohertj2 created pull request dohertj2/lmxopcua#52 2026-04-18 22:35:38 -04:00
Phase 3 PR 53 -- Transport reconnect-on-drop + SO_KEEPALIVE (DL260 no-keepalive quirk)
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:35:35 -04:00
476ce9b7c5 Merge pull request 'Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation' (#51) from phase-3-pr52-dl205-exception-codes into v2
cde018aec1 Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation. Before this PR every server-side Modbus exception AND every transport-layer failure collapsed to BadInternalError (0x80020000) in the driver's Read/Write results, making field diagnosis 'is this a tag misconfig or a driver bug?' impossible from the OPC UA client side. PR 52 adds a MapModbusExceptionToStatus helper that translates per spec: 01 Illegal Function -> BadNotSupported (0x803D0000); 02 Illegal Data Address -> BadOutOfRange (0x803C0000); 03 Illegal Data Value -> BadOutOfRange; 04 Server Failure -> BadDeviceFailure (0x80550000); 05/06 Acknowledge/Busy -> BadDeviceFailure; 0A/0B Gateway -> BadCommunicationError (0x80050000); unknown -> BadInternalError fallback. Non-Modbus failures (socket drop, timeout, malformed frame) in ReadAsync are now distinguished from tag-level faults: they map to BadCommunicationError so operators check network/PLC reachability rather than tag definitions. Why per-DL205: docs/v2/dl205.md documents DL205/DL260 returning only codes 01-04 with specific triggers -- exception 04 specifically means 'CPU in PROGRAM mode during a protected write', which is operator-recoverable by switching the CPU to RUN; surfacing it as BadDeviceFailure (not BadInternalError) makes the fix obvious. Changes in ModbusDriver: Read catch-chain now ModbusException first (-> mapper), generic Exception second (-> BadCommunicationError); Write catch-chain same pattern but generic Exception stays BadInternalError because write failures can legitimately come from EncodeRegister (out-of-range value) which is a driver-layer fault. Unit tests: MapModbusExceptionToStatus theory exercising every code in the table including the 0xFF fallback; Read_surface_exception_02_as_BadOutOfRange with an ExceptionRaisingTransport that forces code 02; Write_surface_exception_04_as_BadDeviceFailure for CPU-mode faults; Read_non_modbus_failure_maps_to_BadCommunicationError with a NonModbusFailureTransport that raises EndOfStreamException. 115/115 Modbus.Tests pass. Integration test: DL205ExceptionCodeTests.DL205_FC03_at_unmapped_register_returns_BadOutOfRange reads HR[16383] which is beyond the seeded uint16 cells on the dl205.json profile; pymodbus returns exception 02 and the driver surfaces BadOutOfRange. 11/11 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#51 2026-04-18 22:35:34 -04:00
Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation
dohertj2 created pull request dohertj2/lmxopcua#51 2026-04-18 22:35:30 -04:00
Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:35:28 -04:00
954bf55d28 Merge pull request 'Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test' (#50) from phase-3-pr51-dl205-xinput into v2
9892a0253d Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test. Integration test DL205XInputTests reads FC02 at the DirectLogicAddress.XInputToDiscrete-resolved address and asserts two behaviors against the dl205.json pymodbus profile: (1) X20 octal (=decimal 16 = Modbus DI 16) reads ON, proving the helper correctly octal-parses the trailing number and adds it to the 0 base; (2) X21 octal reads OFF (not exception) -- per docs/v2/dl205.md §I/O-mapping, 'reading a non-populated X input returns zero, not an exception' on DL260, because the CPU sizes the discrete-input table to the configured I/O not the installed hardware. Pymodbus models this by returning the default 0 value for any DI bit in the configured 'di size' range that wasn't explicitly seeded, matching real DL260 behaviour. Test uses X20 rather than X0 to sidestep a shared-blocks conflict: pymodbus places FC01/FC02 bit-address 0..15 into cell 0, but cell 0 is already uint16-typed (V0 marker = 0xCAFE) per the register-zero quirk test, and shared-blocks semantics allow only one type per cell. X20 octal = DI 16 lands in cell 1 which is free, so both the V0 quirk AND the X-input quirk can coexist in one profile. dl205.json: bits cell 1 seeded value=9 (bits 0 and 3 set -> X20, X23 octal = ON), write-range extended to include cell 1 (though X-inputs are read-only; the write-range entry is required by pymodbus for ANY cell referenced in a bits section even if only reads are expected -- pymodbus validates write-access uniformly). 10/10 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205. No driver code changes -- the XInputToDiscrete helper + FC02 read path already landed in PRs 50 and 21 respectively. This PR closes the integration-test gap that docs/v2/dl205.md called out under test name DL205_Xinput_unpopulated_reads_as_zero.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#50 2026-04-18 22:35:27 -04:00
Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test
dohertj2 created pull request dohertj2/lmxopcua#50 2026-04-18 22:35:23 -04:00
Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:35:20 -04:00
9fb3cf7512 Merge pull request 'Phase 3 PR 50 -- DL260 bit-memory helpers (Y/C/X/SP) + coil integration tests' (#49) from phase-3-pr50-dl205-coil-mapping into v2
b5464f11ee Phase 3 PR 50 -- DL260 bit-memory address helpers (Y/C/X/SP) + live coil integration tests. Adds four new static helpers to DirectLogicAddress covering every discrete-memory bank on the DL260: YOutputToCoil (Y0=coil 2048), CRelayToCoil (C0=coil 3072), XInputToDiscrete (X0=DI 0), SpecialToDiscrete (SP0=DI 1024). Each helper takes the DirectLOGIC ladder-logic address (e.g. 'Y0', 'Y17', 'C1777') and adds the octal-decoded offset to the bank's Modbus base per the DL260 user manual's I/O-configuration chapter table. Uses the same 'octal-walk + reject 8/9' pattern as UserVMemoryToPdu so misaligned addresses fail loudly with a clear ArgumentException rather than silently hitting the wrong coil. Fixes a pymodbus-config bug surfaced during integration-test validation: dl205.json had bits entries at cell indices 2048 / 3072 / 4000, but pymodbus's ModbusSimulatorContext.validate divides bit addresses by 16 before indexing into the shared cell array -- so Modbus coil 2048 reads cell 128, not cell 2048. The sim was returning Illegal Data Address (exception 02) for every bit read in the Y/C/scratch range. Moved bits entries to cells 128 (Y bank marker = 0b101 for Y0=ON, Y1=OFF, Y2=ON), 192 (C bank marker = 0b101 for C0/C1/C2), 250 (scratch cell covering coils 4000..4015). write list updated to the correct cell addresses. Unit tests: YOutputToCoil theory sweep (Y0->2048, Y1->2049, Y7->2055, Y10->2056 octal-to-decimal, Y17->2063, Y777->2559 top of DL260 Y range), CRelayToCoil theory (C0->3072 through C1777->4095), XInputToDiscrete theory, SpecialToDiscrete theory (with case-insensitive 'SP' prefix). Bit_address_rejects_non_octal_digits (Y8/C9/X18), Bit_address_rejects_empty, accepts_lowercase_prefix, accepts_bare_octal_without_prefix. 48/48 Modbus.Tests pass. Integration tests: DL205CoilMappingTests with three facts -- DL260_Y0_maps_to_coil_2048 (FC01 at Y0 returns ON), DL260_C0_maps_to_coil_3072 (FC01 at C0 returns ON), DL260_scratch_Crelay_supports_write_then_read (FC05 write + FC01 read round-trip at coil 4000 proves the DL-mapped coil bank is fully read/write capable end-to-end). 9/9 DL205 integration tests pass against the pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205. Caller opts into the helpers per tag the same way as PR 47's V-memory helper -- pass DirectLogicAddress.YOutputToCoil("Y0") as the ModbusTagDefinition Address; no driver-wide DL-family flag. PR 51 adds the X-input read-side integration test (there's nothing to write since X-inputs are FC02 discrete inputs, read-only); PR 52 exception-code translation; PR 53 transport reconnect-on-drop since DL260 doesn't send TCP keepalives.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#49 2026-04-18 22:35:19 -04:00
Phase 3 PR 50 -- DL260 bit-memory helpers (Y/C/X/SP) + coil integration tests
dohertj2 created pull request dohertj2/lmxopcua#49 2026-04-18 22:35:15 -04:00
Phase 3 PR 50 -- DL260 bit-memory helpers (Y/C/X/SP) + coil integration tests
dohertj2 created branch phase-3-pr53-dl205-reconnect in dohertj2/lmxopcua 2026-04-18 22:34:05 -04:00
dohertj2 pushed to phase-3-pr53-dl205-reconnect at dohertj2/lmxopcua 2026-04-18 22:34:05 -04:00
793c787315 Phase 3 PR 53 -- Transport reconnect-on-drop + SO_KEEPALIVE for DL205 no-keepalive quirk. AutomationDirect H2-ECOM100 does NOT send TCP keepalives per docs/v2/dl205.md behavioral-oddities section -- any NAT/firewall device between the gateway and the PLC can silently close an idle socket after 2-5 minutes of inactivity. The PLC itself never notices and the first SendAsync after the drop would previously surface as IOException / EndOfStreamException / SocketException to the caller even though the PLC is perfectly healthy. PR 53 makes ModbusTcpTransport survive mid-session socket drops: SendAsync wraps the previous body as SendOnceAsync; on the first attempt, if the failure is a socket-layer error (IOException, SocketException, EndOfStreamException, ObjectDisposedException) AND autoReconnect is enabled (default true), the transport tears down the dead socket, calls ConnectAsync to re-establish, and resends the PDU exactly once. Deliberately single-retry -- further failures propagate so the driver health surface reflects the real state, no masking a dead PLC. Protocol-layer failures (e.g. ModbusException with exception code 02) are specifically NOT caught by the reconnect path -- they would just come back with the same exception code after the reconnect, so retrying is wasted wire time. Socket-level vs protocol-level is a discriminator inside IsSocketLevelFailure. Also enables SO_KEEPALIVE on the TcpClient with aggressive timing: TcpKeepAliveTime=30s, TcpKeepAliveInterval=10s, TcpKeepAliveRetryCount=3. Total time-to-detect-dead-socket = 30 + 10*3 = 60s, vs the Windows default 2-hour idle + 9 retries = 2h40min. Best-effort: older OSes that don't expose the fine-grained keepalive knobs silently skip them (catch {}). New ModbusDriverOptions.AutoReconnect bool (default true) threads through to the default transport factory in ModbusDriver -- callers wanting the old 'fail loud on drop' behavior can set AutoReconnect=false, or use a custom transportFactory that ignores the option. Unit tests: ModbusTcpReconnectTests boots a FlakeyModbusServer in-process (real TcpListener on loopback) that serves one valid FC03 response then forcibly shuts down the socket. Transport_recovers_from_mid_session_drop_and_retries_successfully issues two consecutive SendAsync calls and asserts both return valid PDUs -- the second must trigger the reconnect path transparently. Transport_without_AutoReconnect_propagates_drop_to_caller asserts the legacy behavior when the opt-out is taken. Validates real socket semantics rather than mocked exceptions. 142/142 Modbus.Tests pass (113 prior + 2 mapper + 2 reconnect + 25 accumulated across PRs 45-52); 11/11 DL205 integration tests still pass with MODBUS_SIM_PROFILE=dl205 -- no regression from the transport change.
dohertj2 created branch phase-3-pr52-dl205-exception-codes in dohertj2/lmxopcua 2026-04-18 22:34:04 -04:00
dohertj2 pushed to phase-3-pr52-dl205-exception-codes at dohertj2/lmxopcua 2026-04-18 22:34:04 -04:00
cde018aec1 Phase 3 PR 52 -- Modbus exception-code -> OPC UA StatusCode translation. Before this PR every server-side Modbus exception AND every transport-layer failure collapsed to BadInternalError (0x80020000) in the driver's Read/Write results, making field diagnosis 'is this a tag misconfig or a driver bug?' impossible from the OPC UA client side. PR 52 adds a MapModbusExceptionToStatus helper that translates per spec: 01 Illegal Function -> BadNotSupported (0x803D0000); 02 Illegal Data Address -> BadOutOfRange (0x803C0000); 03 Illegal Data Value -> BadOutOfRange; 04 Server Failure -> BadDeviceFailure (0x80550000); 05/06 Acknowledge/Busy -> BadDeviceFailure; 0A/0B Gateway -> BadCommunicationError (0x80050000); unknown -> BadInternalError fallback. Non-Modbus failures (socket drop, timeout, malformed frame) in ReadAsync are now distinguished from tag-level faults: they map to BadCommunicationError so operators check network/PLC reachability rather than tag definitions. Why per-DL205: docs/v2/dl205.md documents DL205/DL260 returning only codes 01-04 with specific triggers -- exception 04 specifically means 'CPU in PROGRAM mode during a protected write', which is operator-recoverable by switching the CPU to RUN; surfacing it as BadDeviceFailure (not BadInternalError) makes the fix obvious. Changes in ModbusDriver: Read catch-chain now ModbusException first (-> mapper), generic Exception second (-> BadCommunicationError); Write catch-chain same pattern but generic Exception stays BadInternalError because write failures can legitimately come from EncodeRegister (out-of-range value) which is a driver-layer fault. Unit tests: MapModbusExceptionToStatus theory exercising every code in the table including the 0xFF fallback; Read_surface_exception_02_as_BadOutOfRange with an ExceptionRaisingTransport that forces code 02; Write_surface_exception_04_as_BadDeviceFailure for CPU-mode faults; Read_non_modbus_failure_maps_to_BadCommunicationError with a NonModbusFailureTransport that raises EndOfStreamException. 115/115 Modbus.Tests pass. Integration test: DL205ExceptionCodeTests.DL205_FC03_at_unmapped_register_returns_BadOutOfRange reads HR[16383] which is beyond the seeded uint16 cells on the dl205.json profile; pymodbus returns exception 02 and the driver surfaces BadOutOfRange. 11/11 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
dohertj2 created branch phase-3-pr51-dl205-xinput in dohertj2/lmxopcua 2026-04-18 22:34:01 -04:00
dohertj2 pushed to phase-3-pr51-dl205-xinput at dohertj2/lmxopcua 2026-04-18 22:34:01 -04:00
9892a0253d Phase 3 PR 51 -- DL260 X-input FC02 discrete-input mapping end-to-end test. Integration test DL205XInputTests reads FC02 at the DirectLogicAddress.XInputToDiscrete-resolved address and asserts two behaviors against the dl205.json pymodbus profile: (1) X20 octal (=decimal 16 = Modbus DI 16) reads ON, proving the helper correctly octal-parses the trailing number and adds it to the 0 base; (2) X21 octal reads OFF (not exception) -- per docs/v2/dl205.md §I/O-mapping, 'reading a non-populated X input returns zero, not an exception' on DL260, because the CPU sizes the discrete-input table to the configured I/O not the installed hardware. Pymodbus models this by returning the default 0 value for any DI bit in the configured 'di size' range that wasn't explicitly seeded, matching real DL260 behaviour. Test uses X20 rather than X0 to sidestep a shared-blocks conflict: pymodbus places FC01/FC02 bit-address 0..15 into cell 0, but cell 0 is already uint16-typed (V0 marker = 0xCAFE) per the register-zero quirk test, and shared-blocks semantics allow only one type per cell. X20 octal = DI 16 lands in cell 1 which is free, so both the V0 quirk AND the X-input quirk can coexist in one profile. dl205.json: bits cell 1 seeded value=9 (bits 0 and 3 set -> X20, X23 octal = ON), write-range extended to include cell 1 (though X-inputs are read-only; the write-range entry is required by pymodbus for ANY cell referenced in a bits section even if only reads are expected -- pymodbus validates write-access uniformly). 10/10 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205. No driver code changes -- the XInputToDiscrete helper + FC02 read path already landed in PRs 50 and 21 respectively. This PR closes the integration-test gap that docs/v2/dl205.md called out under test name DL205_Xinput_unpopulated_reads_as_zero.
dohertj2 created branch phase-3-pr50-dl205-coil-mapping in dohertj2/lmxopcua 2026-04-18 22:34:00 -04:00
dohertj2 pushed to phase-3-pr50-dl205-coil-mapping at dohertj2/lmxopcua 2026-04-18 22:34:00 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:13:50 -04:00
dae29f14c8 Merge pull request 'Phase 3 PR 49 -- Per-device FC03/FC16 register caps with auto-chunking' (#48) from phase-3-pr49-dl205-fc-caps into v2
a3f2f95344 Phase 3 PR 49 -- Per-device FC03/FC16 register caps with auto-chunking. Adds MaxRegistersPerRead (default 125, spec max) + MaxRegistersPerWrite (default 123, spec max) to ModbusDriverOptions. Reads that exceed the cap automatically split into consecutive FC03 requests: the driver dispatches chunks of [cap] regs at incrementing addresses, copies each response into an assembled byte[] buffer, and hands the full payload to DecodeRegister. From the caller's view a 240-char string read against a cap-100 device is still one Read() call returning one string -- the chunking is invisible, the wire shows N requests of cap-sized quantity plus one tail chunk. Writes are NOT auto-chunked. Splitting an FC16 across two transactions would lose atomicity -- mid-split crash leaves half the value written, which is strictly worse than rejecting upfront. Instead, writes exceeding MaxRegistersPerWrite throw InvalidOperationException with a message naming the tag + cap + the caller's escape hatch (shorten StringLength or split into multiple tags). The driver catches the exception internally and surfaces it to IWritable as BadInternalError so the caller pattern stays symmetric with other failure modes. Per-family cap cheat-sheet (documented in xml-doc on the option): Modbus-TCP spec = 125 read / 123 write, AutomationDirect DL205/DL260 = 128 read / 100 write (128 exceeds spec byte-count capacity so in practice 125 is the working ceiling), Mitsubishi Q/FX3U = 64 / 64, Omron CJ/CS = 125 / 123. Not all PLCs reject over-cap requests cleanly -- some drop the connection silently -- so having the cap enforced client-side prevents the hard-to-diagnose 'driver just stopped' failure mode. Unit tests: Read_within_cap_issues_single_FC03_request (control: no unnecessary chunking), Read_above_cap_splits_into_two_FC03_requests (120 regs / cap 100 -> 100+20, asserts exact per-chunk (Address,Quantity) and end-to-end payload continuity starting with register[100] high byte = 'A'), Read_cap_honors_Mitsubishi_lower_cap_of_64 (100 regs / cap 64 -> 64+36), Write_exceeding_cap_throws_instead_of_splitting (110 regs / cap 100 -> status != 0 AND Fc16Requests.Count == 0 to prove nothing was sent), Write_within_cap_proceeds_normally (control: cap honored on short writes too). Tests use a new RecordingTransport that captures the (Address, Quantity) tuple of every FC03/FC16 request so the chunk layout is directly assertable -- the existing FakeTransport does not expose request history. 103/103 Modbus.Tests pass; 6/6 DL205 integration tests still pass against the live pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205.
Compare 2 commits »