The scheduled nightly-windev job failed most nights for host reasons and
filed a Gitea issue each time. Remove the cron trigger and the job, and add
a workflow_dispatch trigger whose windev_mode input (test/build/live) drives
the windows-x86 job, so the live tier runs on demand - from the Actions page
or via scripts/ci/run-windev-ci.sh live - the same way clients are packed and
published on demand. Docs updated to match.
Co-Authored-By: Claude <noreply@anthropic.com>
windev's MxAccessGw now runs DOTNET_/ASPNETCORE_ENVIRONMENT=Production, with
DisableLogin removed and MxGateway:Ldap on Transport=Ldaps, Port=3894,
AllowInsecure=false and the GLAuth cert pinned by SHA-256. Record the env
change and the rollback, and update the stale "GLAuth has no LDAPS" text.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
First real run of the #230-fixed Upgrade-MxGatewayService.ps1: rolling, ~8-9 s each,
env block untouched. #228 KeepsSentTimestamp passes on both (old build +5 h as the
negative control); #226 not observable on QA (empty alarm snapshot, no transitions).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Live MXAccess captures against the windev DEV Galaxy, recorded in
docs/LiveCaptures-2026-11-13.md:
- OperationComplete follows a Suspend/Activate whose synchronous MxStatus is
Pending (advised, resolved item); one Ok row from RespondingLmx. Pinned by
the new OperationCompleteLiveProbeTests live fact, with an
unresolved-reference negative control. (#211 §3.1)
- No public COM event carries completion-only status bytes. All 71
completions were typed MXSTATUS_PROXY[], so they stay raw permanently.
(#211 §3.3)
- Subtag-mode Clear is drivable: the TestAlarm UDAs are MxSecurityOperate,
so AuthenticateUser + WriteSecured toggles them. The new self-driven
LiveSubtag_SelfDrivenRaiseThenClear_SynthesizesClear fact asserts the
UnackAlm -> UnackRtn Clear (mutation-checked). (#210 §3.7)
- The B8 buffered "NoData bootstrap" is a ConfigurationError resolution
failure (detail 6 / 1002). The DEV Galaxy has no buffered attribute, so a
multi-sample capture needs IDE work. provider_switches was not driven. (#210)
- Status-row catalogue for lmxopcua#872: no Warning row seen, and Pending
only on the synchronous Suspend/Activate return.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The process guards matched only ZB.MOM.WW.MxGateway.*; the wonder boxes run
MxGateway.Server.exe / MxGateway.Worker.exe, so the one-gateway guard, the
pre-start OrphanWorkerTerminator guard and the STOP_PENDING kill passed vacuously.
- Image names come from the installed exes (NSSM Application, Worker env path) plus
both known schemes; processes are also matched by exact path (Win32_Process).
- One-gateway guard fails closed: a RUNNING service whose gateway is not visible, at
the Application path, as the service host's child, is an abort.
- STOP_PENDING kill is scoped to this install's processes.
- Staged checks use the installed exe names; staged Worker must be x86; a staged
self-contained runtime older than the live one is refused (-AllowRuntimeDowngrade).
- Carry-over: appsettings*.json and certificates/keys (dashboard.pfx) always keep the
live copy; other live-only non-binary top-level files are carried; hash-verified.
- Env block read from the registry and fingerprinted (names + SHA-256 prefixes, never
values) after stop, swap, start and the stability window; any change aborts.
Sensitive values are redacted from all output and notes.
- File-based master key (vd03) accepted and backed up; a missing env master key
(windev) is a warning. Backup dir is ACL-restricted before anything is written.
- Rollback accepts .bak-<stamp> and .bak.<yyyyMMddTHHmmss> sets and refuses a
mixed Server/Worker stamp; auto-rollback no longer fails on the old SHA.
- -WhatIf now works on Windows PowerShell 5.1 (Get-FileHash returned nothing under
WhatIfPreference); an empty Win32_Service result no longer reads as "unavailable".
- Install-MxGatewayService.ps1 process guard matches both schemes.
- Dry-run harness scripts/deploy/tests (fake box in both layouts, 140 assertions,
passes on pwsh/macOS and Windows PowerShell 5.1) plus a mutation runner (12/12 killed).
- Runbook updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Server and x86 Worker from 76a71bc8 on wonder-app-vd03, about 9 s downtime, env block and
pepper prefix unchanged. Write2 KeepsSentTimestamp passes; RuntimeAlert reads
2026-07-28T20:02:46.830Z. QA still pending (#170). Upgrade-script gaps filed as #230.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
MXAccess reads the VT_DATE time argument of Write2, WriteSecured2 and their
bulk forms as box-local time and converts it to UTC itself. The worker passed
the proto Timestamp's UTC clock fields (the COM marshaler ignores
DateTime.Kind), so on vd03 (UTC-5) a Write2 sent at 01:33:00Z was stored at
06:33:00Z.
VariantConverter.ConvertToComTimestamp converts a timestamp_value instant with
TimeZoneInfo.ConvertTimeFromUtc into the worker's zone (TimeZoneInfo.Local by
default, DST included; an injectable zone for tests). The executor uses it for
the time argument only: value conversion is unchanged, and the read direction
(MXAccess reports UTC; ToTimestamp treats it as UTC) is unchanged. The one
residual loss is MXAccess-side: the repeated fall-back hour cannot be told
apart in an offset-less VT_DATE.
Tests: VariantConverterTimestampTests (UTC-5, US-Eastern DST both edges,
UTC+05:30, UTC, fall-back ambiguity, value path unchanged); the four executor
forwarding tests inject a fixed UTC-5 zone; the windev live Write2 smoke now
sends a past whole-second timestamp and asserts the stored one when applied.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
On the DEV gateway (wonder-app-vd03, 2b13564e), Write2 after
AdviseSupervisory applied the value to MESReceiver_025.MoveInBatchID
(0 -> 212212, OnWriteComplete Ok), and the value was restored to 0. After a
plain Advise, the same Write2 got SecurityError/1008, which is exactly what
the windev run saw. So that refusal came from the plain advise. It does not
show that windev has no writable attribute.
- Client.Tests: add the opt-in LiveGatewayWrite2Tests (gated by
LiveGatewayWriteFact: endpoint, key file and write item env vars). It runs
supervisory advise -> Write2 -> readback -> restore. The value test passed
live on vd03. The timestamp-parity test needs a second opt-in; it fails on
a non-UTC host until #228 is fixed.
- IntegrationTests: the windev Write2 smoke now uses AdviseSupervisory and
restores the original value. It has not been re-run on windev.
- GatewayTesting.md: document the env vars. code-reviews IntegrationTests-033:
correct the "no writable attribute" limit.
The run also found that the Write2 timestamp is read as host-local time
(stored +5 h on the UTC-5 box); filed as #228.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Record of the 2026-11-12 config-only change on wonder-app-vd03: MxGateway__ApiKeyPepper
added to the MxAccessGw AppEnvironmentExtra block (same value, sha256 prefix match),
removed from Server\appsettings.json; authenticated round-trip with a pre-change key,
ScadaBridge MxGateway link unchanged. Runbook and configuration doc now say where the
pepper lives on each wonder box.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A fresh StreamEvents is never replayed, so an initial value published before
the gateway registers the stream's subscriber is lost (lmxopcua#865 —
slow-changing ScanState). Clients had nothing deterministic to wait on.
Contract (additive, proto3):
- StreamEventsRequest.emit_stream_attached = 3 (bool, default false)
- MxEvent.stream_attached = 15 (optional StreamAttached)
- message StreamAttached { uint64 live_after_sequence = 1; }
- OpenSessionReply capability "stream-events-attached-ack"
(GatewayCapabilities.StreamEventsAttachedAck)
When requested, EventStreamService yields the sentinel as the FIRST message,
after AttachEventSubscriber/AttachEventSubscriberWithReplay has returned, so
receipt implies registration; refused attaches never see it. It precedes the
ReplayGap sentinel and replay on a resume. Shape mirrors ReplayGap: family
UNSPECIFIED, no body, worker_sequence 0.
Opt-in rather than always-on: ScadaBridge's MxGateway adapter stores every
streamed event's worker_sequence as its resume cursor, so an unrequested
sentinel would reset it to 0. Default wire behaviour is unchanged.
.NET client: StreamEventsAsync/StreamEventItemsAsync(after, emitStreamAttached),
MxEventStreamItem.IsStreamAttached, MxGatewaySession.SupportsStreamAttachedAck,
and OpenEventStreamAsync -> MxGatewayEventStream (awaits the sentinel, with
attach timeout; refuses older gateways).
Regenerated Contracts/Generated, the client protoset, Go and Python bindings
(also picks up comment-only drift already on main), synced the Rust vendored
proto and set emit_stream_attached in the Rust StreamEventsRequest literals.
No package versions bumped.
Tests: ordering (sentinel first, then events), race proof (event fanned right
after the sentinel is delivered — mutation-checked: fails when the sentinel is
yielded before registration), resume-with-gap order, refused attach emits no
sentinel, default emits none, contract field numbers, capability, and .NET
client wire tests (await, no-capability, older gateway, timeout).
QueryActiveAlarms / alarm transitions reported every wnwrap alarm late by
the record's GMTOFFSET-DSTADJUST: ParseTransitionTimestampUtc treated the
XML DATE+TIME as producer-local and added the offset, but the fields are
already UTC. DEV evidence: RuntimeAlert raise EventTimeUtc 2026-07-28
20:02:46.830 (EventTimeUTCOffsetMins -300) surfaced as 2026-07-29
01:02:46.830Z. The 2026-05-01 probe capture (TIME 13:26:14.709,
GMTOFFSET 240) was committed at 09:44 EDT, so its TIME is UTC too.
GMTOFFSET/DSTADJUST are no longer read. Tests updated + #226 regressions.
New optional MxGateway:Ldap:ServerCertificateThumbprintSha256 (hex SHA-256
of the DER cert; case/colon/dash/space-insensitive; comma/semicolon-separated
string or array, so a rotation can carry old + new). When set, the dashboard's
shared LDAP provider gets a RemoteCertificateValidationCallback via
LdapOptions.ServerCertificateValidationCallback (Auth 0.4.1) that accepts the
server certificate iff its thumbprint matches a pin, ignoring chain/name
errors only then. Unset keeps default OS trust-store validation untouched.
The callback is an init-only, code-only property, so the ILdapAuthService
registration from AddZbLdapAuth is replaced with one built from the bound
options plus the callback. Pins are read straight from configuration because
the binder silently binds the scalar form onto a list as empty.
GatewayOptionsValidator rejects a pin that is not 64 hex chars after
normalization and any pin with Transport=None; the Production hard stops are
unchanged. Pins are shown on the Settings page. Docs: GatewayConfiguration.md,
glauth.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
ShutdownGracefully now Unregisters every server handle first (MXAccess drops its
items and advise subscriptions with it). Only for a server whose Unregister fails
does the UnAdvise -> RemoveItem fallback run. Each step is guarded, logged at Debug,
and the method is idempotent. #176 (AuthenticateUser cache) is unaffected.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Add scripts/deploy/Upgrade-MxGatewayService.ps1 (preflight, stop with STOP_PENDING handling,
backup, Server+Worker swap, start, /health/ready + SHA verify, auto/manual rollback,
one-gateway guard, never touches the NSSM env block) and Install-MxGatewayService.ps1
(service install, restart/recovery settings, env block). Both support -DryRun/-WhatIf.
Dry-run validated on macOS pwsh against a fake layout; untested on a real box.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Event-queue overflow, alarm-feed overflow, subscriber cap, session limit and
oversized commands all surfaced as ResourceExhausted. The status code is
unchanged; the gateway now attaches a machine-readable `mxgw-reason` trailer
(constants in Contracts ResourceExhaustedReasons). The .NET client maps
ResourceExhausted to MxGatewayResourceExhaustedException (an
MxGatewayException subclass; additive) exposing Reason/IsOverflow/
IsSubscriberLimit. Documented in docs/ClientBehaviorFixtures.md; the other
clients get a doc note only.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Diagnosis of the retained Windows-nightly failures (119 scheduled nightlies, 28 red; job logs from
the Gitea API, C:\build\mxaccessgw-ci\ci.log and the windev System log, read-only):
- Checkout (#148, run 827, 2026-09-22): the windev "atomic mkdir" lock was not exclusive.
New-Item -ItemType Directory checks for the directory and then calls CreateDirectory, which
succeeds on an existing directory; a pwsh race harness had both contenders take it in 1900 of
2000 simultaneous rounds. A scheduled run starts windows-x86 and nightly-windev in the same
second, both bootstraps got in, and the nightly's checkout died on .git/index.lock.
Fix: the bootstrap (and a standalone windev-worker-ci.ps1) holds an exclusive FileShare.None
handle on C:\build\mxaccessgw-ci.ci-lock instead (0 of 1000 double acquisitions in the same
harness). The OS drops it if the holder dies, so a killed run leaves no stale lock, and a holder
removes a leftover .git\index.lock, which can only be debris from a killed git.
- windows-x86 no longer runs on the schedule: nightly-windev's live mode already runs the same
Worker build + tests first, so the scheduled copy only doubled the load and created the race.
- Host resources (#128/#129/#131-#135/#138, 2026-07-24..08-03): windev's System log has
Resource-Exhaustion-Detector event 2004 (low virtual memory) every few minutes from 2026-07-23
until an unexpected shutdown/hard reset on 2026-08-03; OOM in MSBuild/csc/protoc,
csc 0xC0000142, PowerShell dying before its first log line and SSH kex resets all fall in that
window and stop after the reset. Host-side; windev-worker-ci.ps1 now logs free commit, physical
memory, disk and testhost count at start and on failure so the next one is correlatable.
- SSH "No route to host" (#144, 2026-09-16): windev was down (unexpected shutdown 00:58, back 05:50).
- Dashboard host build (#143, run 817): two host-building test classes failed at the same instant
in SqliteSecretsStoreMigrator with "cannot start a transaction within a transaction" -- parallel
classes migrating the one per-process secrets store. Tests now build the gateway through
TestSupport/TestGatewayHost, which gives each host its own store; TestGatewayHostTests guards it.
- Gateway E2E "Worker pipe disconnected" (#142/#145/#146/#147) and handshaking-to-ready (#141) were
the fake-worker partial-frame cancellation and readiness-race defects fixed in #153 (d779daf6):
7 gateway-suite failures in 51 windev runs before it, 0 in 28 since. The Worker watchdog and
burst-coalescing failures (#126/#127/#139) last failed before 50322bac / 7da52b65 (Aug 2026).
- 2026-10-15..20 was the NU1903 package-audit restore failure, fixed in fb20997.
Docs: GatewayTesting.md (lock, host-resource triage) and scripts/ci/README.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
- New MxGateway:Worker:WorkerHeartbeatGraceSeconds (default 15), exported as
MXGATEWAY_WORKER_HEARTBEAT_GRACE_MS and read by WorkerPipeSessionOptions.FromEnvironment
(a grace the ceiling does not exceed falls back to the default so the worker
still starts). Validation now checks WorkerHeartbeatStuckCeilingSeconds against
the configured grace; the copied WorkerWatchdogGraceSeconds constant is gone.
- EffectiveWorkerConfiguration and the dashboard Settings page now show the worker
heartbeat send interval, watchdog grace and stuck ceiling (render test added).
- Docs updated.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The worker's heartbeat send interval (5 s) and its own STA-watchdog stuck
ceiling (75 s) were compile-time defaults the gateway never reached, and
nothing checked that the gateway's HeartbeatGraceSeconds exceeded the real send
interval, so a misconfigured grace could kill healthy workers.
- New MxGateway:Worker options WorkerHeartbeatSendIntervalSeconds (default 5)
and WorkerHeartbeatStuckCeilingSeconds (default 75), exported by
WorkerProcessLauncher as MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS and
MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS, the same env-var path the other
worker settings use.
- The worker's production WorkerPipeSession reads them through
WorkerPipeSessionOptions.FromEnvironment; a missing/invalid value, or a
ceiling not above the worker's 15 s watchdog grace, keeps the default rather
than failing the worker.
- Startup validation: HeartbeatGraceSeconds > WorkerHeartbeatSendIntervalSeconds;
send interval > 0; worker ceiling > 15 s; both at most 86400 s.
- Docs: GatewayConfiguration, WorkerProcessLauncher (env table now also lists
the previously missing MXGATEWAY_ALARM_ACK_CLIENT_NAME), worker design doc.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
R21-K12: WorkerFrameWriter.WriteBatchAsync allocated a TaskCompletionSource
(plus its Task) per frame on the event drain hot path. PendingFrame now holds
its terminal state itself (Interlocked pending/succeeded/faulted/canceled) and
only single-frame WriteAsync frames, which race their completion against the
write lock, get a TCS. A batch caller reads each frame's outcome after its own
drain pass: every frame a pass claims is terminal before that pass releases the
lock, so nothing is left to await. First-failure-in-batch-order, tombstoning,
claim/cancel interlock and flush coalescing are unchanged.
R21-K13: WnWrapAlarmConsumer.ParseSnapshotXml streams the GetXmlCurrentAlarms2
payload with an XmlTextReader (same defaults XmlDocument.LoadXml uses:
Normalization off, DTDs parsed, no resolver; Significant whitespace only)
instead of building a full XmlDocument every 500 ms poll.
Behaviour is pinned by new tests: batch first-failure ordering (own drain and
drained by another lock holder), batch cancellation tombstoning, batch flush
failure, and a differential test running the replaced XmlDocument parser as an
oracle over a 48-payload corpus (CRLF, CDATA, entities, DTD, namespaces,
nesting, malformed). Mutation checks on windev: 8 of 8 injected regressions
(whitespace, normalization, DTD, namespace, CDATA, batch last-failure, batch
ignored failures, ignored tombstone) fail the new tests.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
R21-O3: WorkerApplication.Run's failure lines logged only the exception
type. Each now also carries exception_message, scrubbed by the new
WorkerLogRedactor.RedactMessage: the value of any name=value / name: value
pair whose name looks sensitive and any mxgw_ API key token are replaced,
line breaks are flattened and the text is capped at 512 characters. The
AppDomain unhandled-exception hook stays type-only, since an exception
from an arbitrary thread can carry command values.
R21-O7: StaCommandDispatcher.ExecuteQueuedCommandAsync logs
WorkerCommandStarted (correlation id, method, queued_ms) and
WorkerCommandCompleted (status, HRESULT, elapsed_ms) when a CommandLogger
is set. IWorkerLogger has no Debug level, so the lines are opt-in through
MXGATEWAY_WORKER_LOG_COMMANDS=1|true (WorkerCommandLogging), which the
worker inherits from the gateway process environment. No payloads or
diagnostic messages are logged. Docs updated. (mxaccessgw#184)
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
A frame read that hits end of stream means the gateway closed its end of
the pipe (usually because it died). WorkerApplication mapped every
WorkerFrameProtocolException to ProtocolViolation (6); EndOfStream now
exits as PipeConnectionFailed (5), alongside the IOException a broken
pipe raises.
Event-queue overflow exited as the generic UnexpectedFailure (1). The
event drain loop now unwinds with WorkerEventQueueFaultException carrying
the fault category, and QueueOverflow exits with the new
WorkerExitCode.EventQueueOverflow (8). Other categories keep exit 1.
The gateway does not decode worker exit codes (it only logs the number),
so no gateway change is needed. WorkerBootstrap.md and
MxAccessWorkerInstanceDesign.md updated. (mxaccessgw#186)
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Adds WorkerExecutableHealthCheck (configured worker .exe exists) and
GalaxySqlHealthCheck (IGalaxyRepository.TestConnectionAsync bounded by a 5 s
TimeProvider-driven timeout). Both are tagged ready only, never live, so an
outage takes the node out of rotation without triggering a restart; sessions
stay on the active tier so zero sessions is still healthy for Overview.
Registrations move into AddGatewayHealthChecks() so the tier tagging is
unit-tested. LDAP is not added (sign-in already surfaces bind failures).
docs/Diagnostics.md lists the two new checks.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The replay ring was bounded only by ReplayBufferCapacity (1024 events) and
ReplayRetentionSeconds. Event size is unbounded up to the worker frame size,
so a burst of large-array events could pin gigabytes per session while the
count looked small.
New MxGateway:Events:ReplayBufferMaxBytes (default 64 MiB, 0 disables) caps
the summed serialized size (MxEvent.CalculateSize, measured only when the cap
is on). Over the cap the oldest entries are evicted, exactly like the count
cap, so a resuming subscriber sees the existing ReplayGap path; an event bigger
than the whole cap is not retained. Every eviction (count, age or byte) now
clears its slot, so an evicted event is released immediately instead of
staying referenced until the slot is reused.
The 64 MiB default is a judgement call: it never binds for scalar traffic
(1024 x a few hundred bytes) and only trims large-array bursts.
Tests: SessionEventDistributorTests byte-cap eviction, single oversized event,
cap 0 = count only (the first two fail with the cap enforcement removed);
validator rejects a negative value. Docs: GatewayConfiguration.md, Sessions.md,
DesignDecisions.md; appsettings.json carries the key.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
R21-O14: MxGateway:Worker:HeartbeatIntervalSeconds was documented as the
worker heartbeat send interval, but it never reached the worker (which sends
on its own fixed 5 s) and only set the gateway's HeartbeatCheckInterval. It is
renamed HeartbeatCheckIntervalSeconds (default 5, unchanged). The old key stays
as a deprecated alias with the same meaning so existing appsettings keep
working; setting both is a validation error. The grace-vs-interval check now
compares against the resolved check interval.
R21-O15: WorkerClientOptions.EventChannelFullModeTimeout and
HeartbeatStuckCeiling were always their compile-time defaults. They are now
MxGateway:Worker:EventChannelFullModeTimeoutMilliseconds (default 5000, > 0)
and HeartbeatStuckCeilingSeconds (default 75, >= HeartbeatGraceSeconds). The
factory's mapping moved into SessionWorkerClientFactory.CreateWorkerClientOptions
so every field is set from configuration and is testable. The effective-config
record shows the resolved check interval and both new values.
Docs: GatewayConfiguration.md, GatewayProcessDesign.md sample,
MxAccessWorkerInstanceDesign.md heartbeat section; appsettings.json uses the
new keys.
Tests: CreateWorkerClientOptions mapping + defaults (fail under a mutated
mapping), alias honoured, both-keys conflict, and bounds for the new options.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
R21-O12: GatewaySession already owned an async DisposeAsync teardown but did not
declare IAsyncDisposable, so anything holding it as IAsyncDisposable (or a DI
container) could not find the teardown. Declaring it changes no call site;
the existing await-using sites bound to the same method by pattern.
R21-O13: KillWorker(string) had no callers and was an ungated kill that
bypassed _closeLock. Deleted it; docs/Sessions.md and the test comments now
name KillWorkerWithCloseGateAsync, the real kill path.
Regression test: GatewaySessionTests.GatewaySession_ImplementsIAsyncDisposable
(fails before the interface is declared).
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The launcher's Polly startup-probe pipeline was its only recorder and was
removed in mxaccessgw#188, so the counter, the RetryAttempted method and the
snapshot's RetryAttempts / RetryAttemptsByArea fields carried a permanent
zero. No dashboard page or in-repo alert rule references them. Metrics.md
drops the row and the snapshot shape (which also gains the missing
AlarmProviderSwitchCount field).
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Add Dashboard DisableLogin/AutoLoginUser/CookieName, Alarms:Fallback and Tls,
matching the option classes and the per-option tables below the block.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
--pepper on the command line lands in shell history and the process list.
Add --pepper-stdin (first stdin line), warn on stderr when --pepper is used,
and reject both together. Documented in GatewayProcessDesign.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Set retainedFileCountLimit=30, fileSizeLimitBytes=50 MiB and rollOnFileSizeLimit=true on the
file sink in appsettings.json and appsettings.Development.json; document under a new Logging
section in docs/GatewayConfiguration.md; add a guard test over the shipped config.
WorkerProcessStartedProbe only checks HasExited, so a retry could never change
the outcome. Remove StartupProbeRetryAttempts/StartupProbeRetryDelayMilliseconds,
their validation, the launcher's Polly retry pipeline and the docs; the probe now
runs once under StartupTimeoutSeconds. Stale config keys are ignored by the binder.
0.2.1 on the feed predates the 488649c AcknowledgeAlarmRequest
operator_password/operator_domain fields; 0.3.0 ships them so OtOpcUa can
adopt operator-authenticated alarm ack (lmxopcua#749).
NT AUTHORITY\NETWORK marks a network logon, not a remote caller. On windev
a gateway run from an SSH session carries it in its own token, so the deny
entry locked the gateway's same-machine workers out (UnauthorizedAccess on
connect; 15 fake-worker tests failed). The ACL now holds exactly one entry:
FullControl for the gateway's user.
On Windows each worker pipe is created via NamedPipeServerStreamAcl with a
protected DACL granting FullControl only to the gateway process user (the
worker is launched under the same account) and denying NETWORK logons. On
non-Windows hosts (test matrix) the pipe uses PipeOptions.CurrentUserOnly.
Tests assert the factory ACL and the ACL read back from the created pipe
(Windows), and that a same-user client still connects.
Adds both secured bulk kinds to GatewayLogRedactor's credential-bearing set,
plus a contract cross-check test that walks every MxCommand payload descriptor
and fails if a secured or password-bearing command kind is not redacted.
Stream E made the worker wait once for all uncached tags. Fix the Go, Python, Rust, Java
and .NET library docs and CLI help text, the proto comment (default is the worker's
1000 ms), and the worker design doc. Regenerated Contracts Generated/ and the Java
generated protos; both diffs are comment-only.
- Sessions.md / GatewayConfiguration.md: the dashboard Browse live-data session is
unary-only, is reaped by UnattachedSessionGraceSeconds when idle, and reopens via
EnsureReadyAsync; only the alarm monitor is exempt.
- GatewayConfiguration.md: a refused second subscriber gets ResourceExhausted, not AlreadyExists.
- Grpc.md: rewrite the event streaming model around the SessionEventDistributor pump and
replay ring; add EventSubscriberLimitReached to the mapping snippet; describe what
clients see while the gateway is stopping.
WorkerClient.SetFaulted already records mxgateway.faults; EventStreamService added a
WorkerFaulted fault per subscriber, so one fault read as 1+K. The subscriber now records
only its WorkerFault disconnect reason. docs/Metrics.md updated.