47 lines
4.4 KiB
Markdown
47 lines
4.4 KiB
Markdown
# G7: FOCAS live-CNC smoke on a real FANUC control (2026-11-13)
|
||
|
||
**Result: PASS.** Every criterion passes. An axis tag was added to vd03 for the axis criterion (see "Axis position"
|
||
below). The one item not done is the comparison of the identity values against the control panel, which needs a person
|
||
at the machine.
|
||
|
||
## Setup
|
||
|
||
- **Target:** the deployed DEV server on wonder-app-vd03 (`opc.tcp://10.220.157.247:4840`), master `76e73e7d` since
|
||
12:28Z the same day. Its FOCAS driver `focas-z-34184` polls the Makino **Z-34184**, a FANUC **31i-B** (series
|
||
G431), over the wire client (FOCAS2 PDU v3).
|
||
- **Access:** read-only. OPC UA reads and subscriptions came from the Mac with `otopcua-cli` (anonymous). The server
|
||
log was pulled over SMB (`winrm smb pull`, file copy only). No remote exec, no configuration change, no deploy.
|
||
|
||
## Criteria (`docs/plans/v2-ga-lab-gates-plan.md` §G7)
|
||
|
||
| Criterion | Result | Evidence |
|
||
|---|---|---|
|
||
| The wire client opens a FOCAS2 session | **PASS.** The driver has served Good values since boot (12:28:45Z); every value below comes from that live session. | `reads.txt` |
|
||
| Identity nodes return non-null values | **PASS** (non-null). `SeriesNumber` G431, `Version` 22.0, `CncType` 31, `MtType` MM, `MaxAxes` 32, `AxisCount` 7, all Good. **Not compared with the control panel** (needs a person at the machine). G431 matches the series recorded for this control in the 2026-10 wire-decode work. | `reads.txt` |
|
||
| An axis position reads Good with a plausible value | **PASS after the deploy below** (`Axes/X/AbsolutePosition` = 280.1574, Good). Before it: vd03's configuration authors no `Axes/` tags, and adding one would mean a deploy to DEV. Plausible Good values from the same live session: `Spindle/S1/Load` 56.7 % and `MotorSpeedPct` (moving), `Timers/CuttingSeconds`, `OperationMode/ModeText` AUTO, `Program/Name` `//CNC_MEM/USER/LIBRARY/O1111`. The position decode is pinned by real-31i-B captures from this machine (`docs/drivers/FOCAS.md` §"Wire decode corrections (2026-10)"). | `reads.txt` |
|
||
| A subscription delivers ≥ 3 updates within 5 s | **PASS:** 6 Good updates of `Spindle/S1/Load` in 5 s (13:15:16–13:15:21Z). | `sub5.txt` |
|
||
| No `EW_SOCKET` (-1) / `EW_HANDLE` (-7) during a 2-minute soak | **PASS.** Soak 13:15:22–13:17:27Z: a recursive subscription on the driver's 22 variables got 272 notifications, and 21 variables were Good throughout. The 22nd, `Program/BlockCount`, read `BadNoData` throughout (the control does not report it; the same in every deploy record). **0 `EW_SOCKET`/`EW_HANDLE` in the whole day's server log.** The only ERR/WRN lines in the window come from these reads connecting by IP ("domain not listed in the server certificate") and the known DEV mesh-PSK warning. | `soak-summary.txt`, `soak-notifications.txt`, `vd03-log-window.txt` |
|
||
|
||
Record: CNC FANUC 31i-B (Makino Z-34184), series G431, version 22.0; test date 2026-11-13; OtOpcUa `76e73e7d`
|
||
(deployed); client `otopcua-cli` from `c9bc358d`.
|
||
|
||
## Axis position (owner-approved DEV config deploy, 2026-11-13 15:30Z)
|
||
|
||
The owner approved adding an axis tag to vd03 so the axis criterion could be checked directly.
|
||
- **Authoring:** in vd03's AdminUI `/raw`: device `z-34184` → **Browse device** (a live FOCAS browse of the control
|
||
listed axes X, Y, Z, B, C, AA6, AA7) → selected `FOCAS/z-34184/Axes/X/AbsolutePosition` with "Create matching
|
||
tag-groups" → **Add 1 tag**.
|
||
- **Deploy:** `e9fbe63e`, revision `f902e9409d79…`, sealed 15:30:13Z. It also cleared the standing "Configuration
|
||
drift" chip left by the #903 edit-and-revert check.
|
||
- **Apply:** server log `AddressSpaceApplier: applied plan (kind="PureAdd", added=3, removed=0, changed=0, …
|
||
rebuild=false)` and `raw subtree materialised (containers=2, tags=1, subset=true, failed=0)`. This was a surgical
|
||
add: no rebuild, existing subscriptions untouched (`vd03-log-deploy-excerpt.txt`).
|
||
- **Read:** `ns=2;s=focas-z-34184/z-34184/FOCAS/z-34184/Axes/X/AbsolutePosition` = **280.1574, Good**, 11 s after the
|
||
seal. ServiceLevel stayed 250.
|
||
- **Subscription:** 30 s, the axis held still (one Good notification, `axis-sub30.txt`). The 5-update subscribe
|
||
criterion is met by `Spindle/S1/Load` above.
|
||
- **Re-check of all 23 variables:** 22 Good + `BlockCount` `BadNoData`, as before (`after-deploy-summary.txt`).
|
||
- **Log:** still 0 `EW_SOCKET`/`EW_HANDLE` for the day. The only ERR lines after the deploy are these reads by IP.
|
||
|
||
The tag is left in place on vd03 as a permanent axis-position monitor.
|