# G7: FOCAS live-CNC smoke on a real FANUC control (2026-11-13) **Result: PASS.** Every criterion passes. An axis tag was added to vd03 for the axis criterion (see "Axis position" below). The one item not done is the comparison of the identity values against the control panel, which needs a person at the machine. ## Setup - **Target:** the deployed DEV server on wonder-app-vd03 (`opc.tcp://10.220.157.247:4840`), master `76e73e7d` since 12:28Z the same day. Its FOCAS driver `focas-z-34184` polls the Makino **Z-34184**, a FANUC **31i-B** (series G431), over the wire client (FOCAS2 PDU v3). - **Access:** read-only. OPC UA reads and subscriptions came from the Mac with `otopcua-cli` (anonymous). The server log was pulled over SMB (`winrm smb pull`, file copy only). No remote exec, no configuration change, no deploy. ## Criteria (`docs/plans/v2-ga-lab-gates-plan.md` §G7) | Criterion | Result | Evidence | |---|---|---| | The wire client opens a FOCAS2 session | **PASS.** The driver has served Good values since boot (12:28:45Z); every value below comes from that live session. | `reads.txt` | | Identity nodes return non-null values | **PASS** (non-null). `SeriesNumber` G431, `Version` 22.0, `CncType` 31, `MtType` MM, `MaxAxes` 32, `AxisCount` 7, all Good. **Not compared with the control panel** (needs a person at the machine). G431 matches the series recorded for this control in the 2026-10 wire-decode work. | `reads.txt` | | An axis position reads Good with a plausible value | **PASS after the deploy below** (`Axes/X/AbsolutePosition` = 280.1574, Good). Before it: vd03's configuration authors no `Axes/` tags, and adding one would mean a deploy to DEV. Plausible Good values from the same live session: `Spindle/S1/Load` 56.7 % and `MotorSpeedPct` (moving), `Timers/CuttingSeconds`, `OperationMode/ModeText` AUTO, `Program/Name` `//CNC_MEM/USER/LIBRARY/O1111`. The position decode is pinned by real-31i-B captures from this machine (`docs/drivers/FOCAS.md` §"Wire decode corrections (2026-10)"). | `reads.txt` | | A subscription delivers ≥ 3 updates within 5 s | **PASS:** 6 Good updates of `Spindle/S1/Load` in 5 s (13:15:16–13:15:21Z). | `sub5.txt` | | No `EW_SOCKET` (-1) / `EW_HANDLE` (-7) during a 2-minute soak | **PASS.** Soak 13:15:22–13:17:27Z: a recursive subscription on the driver's 22 variables got 272 notifications, and 21 variables were Good throughout. The 22nd, `Program/BlockCount`, read `BadNoData` throughout (the control does not report it; the same in every deploy record). **0 `EW_SOCKET`/`EW_HANDLE` in the whole day's server log.** The only ERR/WRN lines in the window come from these reads connecting by IP ("domain not listed in the server certificate") and the known DEV mesh-PSK warning. | `soak-summary.txt`, `soak-notifications.txt`, `vd03-log-window.txt` | Record: CNC FANUC 31i-B (Makino Z-34184), series G431, version 22.0; test date 2026-11-13; OtOpcUa `76e73e7d` (deployed); client `otopcua-cli` from `c9bc358d`. ## Axis position (owner-approved DEV config deploy, 2026-11-13 15:30Z) The owner approved adding an axis tag to vd03 so the axis criterion could be checked directly. - **Authoring:** in vd03's AdminUI `/raw`: device `z-34184` → **Browse device** (a live FOCAS browse of the control listed axes X, Y, Z, B, C, AA6, AA7) → selected `FOCAS/z-34184/Axes/X/AbsolutePosition` with "Create matching tag-groups" → **Add 1 tag**. - **Deploy:** `e9fbe63e`, revision `f902e9409d79…`, sealed 15:30:13Z. It also cleared the standing "Configuration drift" chip left by the #903 edit-and-revert check. - **Apply:** server log `AddressSpaceApplier: applied plan (kind="PureAdd", added=3, removed=0, changed=0, … rebuild=false)` and `raw subtree materialised (containers=2, tags=1, subset=true, failed=0)`. This was a surgical add: no rebuild, existing subscriptions untouched (`vd03-log-deploy-excerpt.txt`). - **Read:** `ns=2;s=focas-z-34184/z-34184/FOCAS/z-34184/Axes/X/AbsolutePosition` = **280.1574, Good**, 11 s after the seal. ServiceLevel stayed 250. - **Subscription:** 30 s, the axis held still (one Good notification, `axis-sub30.txt`). The 5-update subscribe criterion is met by `Spindle/S1/Load` above. - **Re-check of all 23 variables:** 22 Good + `BlockCount` `BadNoData`, as before (`after-deploy-summary.txt`). - **Log:** still 0 `EW_SOCKET`/`EW_HANDLE` for the day. The only ERR lines after the deploy are these reads by IP. The tag is left in place on vd03 as a permanent axis-position monitor.