Joseph Doherty 2a74daf228 ADR-002 — driver-vs-virtual dispatch: DriverNodeManager routes reads/writes/subscriptions across driver tags and virtual (scripted) tags via a single NodeManager with a NodeSource tag on NodeScopeResolver's output. Locks the architecture decision Phase 7 Stream G was going to have to make anyway — documenting it up front so the stream implementation can reference the chosen shape instead of rediscovering it. Option A (separate VirtualTagNodeManager sibling) rejected because shared Equipment folders owning both driver and virtual children would force two NodeManagers to fight for ownership on every Equipment node — the common case, not the exception — defeating the separation. Option C (virtual engine registers as a synthetic IDriver through DriverTypeRegistry) rejected because DriverInstance shape is wrong for scripting config (no DriverType, no HostAddress, no connectivity probe, no NSSM wrapper), IDriver.InitializeAsync semantics don't match script compilation, Polly resilience wrappers calibrated for network calls would either passthrough pointlessly or tune wrong, and Admin UI would need special-casing everywhere to hide fields that don't apply. Option B (single DriverNodeManager, NodeScopeResolver returns NodeSource enum alongside ScopeId, dispatch branches on source) accepted because it preserves one address-space tree with one walker, ACL binding works identically for both kinds, Phase 6.1 resilience + Phase 6.2 audit apply uniformly to the driver branch without needing Roslyn analyzer exemptions, and adding future source kinds is a single-enum-case addition. NodeScopeResolver.Resolve returns NodeScope(ScopeId, NodeSource, DriverInstanceId?, VirtualTagId?); DriverNodeManager pattern-matches on scope.Source and routes to either the driver dictionary or IVirtualTagEngine. OPC UA client writes to a virtual node return BadUserAccessDenied before the dispatch branch because Phase 7 decision #6 restricts virtual-tag writes to scripts via ctx.SetVirtualTag. Dispatch test coverage specified for Stream G.4: mixed Equipment folders browsing correctly, read routing per source kind, subscription fan-out across both kinds, the BadUserAccessDenied guard on virtual writes, and script-driven writes firing subscription notifications. ADR-001's walker gains the VirtualTag config-DB table as an additional input channel alongside Tag; NodeScopeResolver's ScopeId return stays unchanged so Phase 6.2's ACL trie needs no modification. Consequences flagged: whether IVirtualTagEngine lives in Core.Abstractions vs Phase 7's Core.VirtualTags project, and whether future server-side methods on virtual nodes would route through this dispatch, both marked out-of-scope for ADR-002.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 16:08:01 -04:00
..
ADR-002 — driver-vs-virtual dispatch: DriverNodeManager routes reads/writes/subscriptions across driver tags and virtual (scripted) tags via a single NodeManager with a NodeSource tag on NodeScopeResolver's output. Locks the architecture decision Phase 7 Stream G was going to have to make anyway — documenting it up front so the stream implementation can reference the chosen shape instead of rediscovering it. Option A (separate VirtualTagNodeManager sibling) rejected because shared Equipment folders owning both driver and virtual children would force two NodeManagers to fight for ownership on every Equipment node — the common case, not the exception — defeating the separation. Option C (virtual engine registers as a synthetic IDriver through DriverTypeRegistry) rejected because DriverInstance shape is wrong for scripting config (no DriverType, no HostAddress, no connectivity probe, no NSSM wrapper), IDriver.InitializeAsync semantics don't match script compilation, Polly resilience wrappers calibrated for network calls would either passthrough pointlessly or tune wrong, and Admin UI would need special-casing everywhere to hide fields that don't apply. Option B (single DriverNodeManager, NodeScopeResolver returns NodeSource enum alongside ScopeId, dispatch branches on source) accepted because it preserves one address-space tree with one walker, ACL binding works identically for both kinds, Phase 6.1 resilience + Phase 6.2 audit apply uniformly to the driver branch without needing Roslyn analyzer exemptions, and adding future source kinds is a single-enum-case addition. NodeScopeResolver.Resolve returns NodeScope(ScopeId, NodeSource, DriverInstanceId?, VirtualTagId?); DriverNodeManager pattern-matches on scope.Source and routes to either the driver dictionary or IVirtualTagEngine. OPC UA client writes to a virtual node return BadUserAccessDenied before the dispatch branch because Phase 7 decision #6 restricts virtual-tag writes to scripts via ctx.SetVirtualTag. Dispatch test coverage specified for Stream G.4: mixed Equipment folders browsing correctly, read routing per source kind, subscription fan-out across both kinds, the BadUserAccessDenied guard on virtual writes, and script-driven writes firing subscription notifications. ADR-001's walker gains the VirtualTag config-DB table as an additional input channel alongside Tag; NodeScopeResolver's ScopeId return stays unchanged so Phase 6.2's ACL trie needs no modification. Consequences flagged: whether IVirtualTagEngine lives in Core.Abstractions vs Phase 7's Core.VirtualTags project, and whether future server-side methods on virtual nodes would route through this dispatch, both marked out-of-scope for ADR-002.
2026-04-20 16:08:01 -04:00
Harden v2 design against the four findings from the 2026-04-17 Codex adversarial review of the db schema and admin UI: (1) DriverInstance.NamespaceId now enforces a same-cluster invariant in three layers (sp_ValidateDraft cross-table check using the new UX_Namespace_Generation_LogicalId_Cluster composite index, server-side namespace-selection API scoping that prevents bypass via crafted requests, and audit-log entries on cross-cluster attempts) so a draft for cluster A can no longer bind to cluster B's namespace and leak its URI into A's endpoint; (2) the Namespace table moves from cluster-level to generation-versioned with append-only logical-ID identity and locked NamespaceUri/Kind across generations so admins can no longer disable a namespace that a published driver depends on outside the publish/diff/rollback flow, the cluster-create workflow opens an initial draft containing the default namespaces instead of writing namespace rows directly, and the Admin UI Namespaces tab becomes hybrid (read-only over published, click-to-edit opens draft) like the UNS Structure tab; (3) ZTag/SAPID fleet-wide uniqueness moves from per-generation indexes (which silently allow rollback or re-enable to reintroduce duplicates) into a new ExternalIdReservation table that sits outside generation versioning, with sp_PublishGeneration reserving atomically via MERGE under transaction lock so a different EquipmentUuid attempting the same active value rolls the whole publish back, an FleetAdmin-only sp_ReleaseExternalIdReservation as the only path to free a value for reuse with audit trail, and a corresponding Release-reservation operator workflow in the Admin UI; (4) Equipment.EquipmentId is now system-generated as 'EQ-' + first 12 hex chars of EquipmentUuid, never operator-supplied or editable, removed from the Equipment CSV import schema entirely (rows match by EquipmentUuid for updates or create new equipment with auto-generated identifiers when no UUID is supplied), with a new Merge-or-Rebind-equipment operator workflow handling the rare case where two UUIDs need to be reconciled — closing the corruption path where typos and bulk-import renames were minting duplicate identities and breaking downstream UUID-keyed lineage. New decisions #122-125 with explicit "supersedes" notes for the earlier #107 (cluster-level namespace) and #116 (operator-set EquipmentId) frames they revise.
2026-04-17 11:08:58 -04:00
FOCAS version-matrix stabilization (PR 1 of #220 split) — ship the cheap half of the hardware-free stability gap ahead of the Tier-C out-of-process split. Without any CNC or simulator on the bench, the highest-leverage move is to catch operator config errors at init time instead of at steady-state per-read. Adds FocasCncSeries enum (Unknown/16i/0i-D/0i-F family/30i family/PowerMotion-i) + FocasCapabilityMatrix static class that encodes the per-series documented ranges for macro variables (cnc_rdmacro/wrmacro), parameters (cnc_rdparam/wrparam), and PMC letters + byte ceilings (pmc_rdpmcrng/wrpmcrng) straight from the Fanuc FOCAS Developer Kit. FocasDeviceOptions gains a Series knob (defaults Unknown = permissive so pre-matrix configs don't break on upgrade). FocasDriver.InitializeAsync now calls FocasAddress.TryParse on every tag + runs FocasCapabilityMatrix.Validate against the owning device's declared series, throwing InvalidOperationException with a reason string that names both the series and the documented limit ("Parameter #30000 is outside the documented range [0, 29999] for Thirty_i") so an operator can tell whether the mismatch is in the config or in their declared CNC model. Unknown series skips validation entirely. Ships 46 new theory cases in FocasCapabilityMatrixTests.cs — covering every boundary in the matrix (widen 16i->0i-F: macro ceiling 999->9999, param 9999->14999; widen 0i-F->30i: PMC letters +K+T; PMC-number 16i=999/0i-D=1999/0i-F=9999/30i=59999), permissive Unknown-series behavior, rejection-message content, and case-insensitive PMC-letter matching. Widening a range without updating docs/v2/focas-version-matrix.md fails a test because every InlineData cites the row it reflects. Full FOCAS test suite stays at 165/165 passing (119 existing + 46 new). Also authors docs/v2/focas-version-matrix.md as the authoritative range reference with per-function citations, CNC-series era context, error-surface shape, and the link back to the matrix code; docs/v2/implementation/focas-isolation-plan.md as the multi-PR plan for #220 Tier-C isolation (Shared contracts -> Host skeleton -> move Fwlib32 calls -> Supervisor+respawn -> MMF+ops glue, 2200-3200 LOC across 5 PRs mirroring the Galaxy Tier-C topology); and promotes docs/drivers/FOCAS-Test-Fixture.md from "version-matrix coverage = no" to explicit coverage via the new test file + cross-links to the matrix and isolation-plan docs. Leaves task #220 open since isolation itself (the expensive half) is still ahead.
2026-04-20 13:44:37 -04:00
Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research document. 451-line doc at docs/v2/mitsubishi.md mirroring the docs/v2/dl205.md template for the MELSEC family (Q-series + QJ71MT91, L-series + LJ71MT91, iQ-R + RJ71EN71, iQ-R built-in Ethernet, iQ-F FX5U built-in, FX3U + FX3U-ENET / FX3U-ENET-P502, FX3GE built-in). Like Siemens S7, MELSEC Modbus is a patchwork of per-site-configured add-on modules rather than a fixed firmware stack, but the MELSEC-specific traps are different enough to warrant their own document. Key findings worth flagging for the PR 58+ implementation track: (1) MODULE NAMING TRAP -- QJ71MB91 is SERIAL RTU, not TCP. The Q-series TCP module is QJ71MT91. Driver docs + config UI should surface this clearly because the confusion costs operators hours when they try to connect to an RS-232 module via Ethernet. (2) NO CANONICAL MAPPING -- every MELSEC Modbus site has a unique 'Modbus Device Assignment Parameter' block of up to 16 assignments (each binding a MELSEC device range like D0..D1023 to a Modbus-address range); the driver must treat the mapping as runtime config, not device-family profile. (3) X/Y BASE DEPENDS ON FAMILY -- Q/L/iQ-R use HEX notation for X/Y (X20 = decimal 32), FX/iQ-F use OCTAL (X20 = decimal 16, same as DL260); iQ-F has a GX Works3 project toggle that can flip this. Single biggest off-by-N source in MELSEC driver code -- driver address helper must take a family selector. (4) Word order CDAB across Q/L/iQ-R/iQ-F by default (CPU-level, not module-level) -- no user-configurable swap on the server side. FX5U's SWAP instruction is for CLIENT mode only. Driver Mitsubishi profile default must be ByteOrder.WordSwap, matching DL260 but OPPOSITE of Siemens S7. (5) D-registers are BINARY by default (opposite of DL205's BCD-by-default). FNC 18 BCD / FNC 19 BIN instructions confirm binary-by-default in the ladder. Caller must explicitly opt-in to Bcd16/Bcd32 tags when the ladder stores BCD, same pattern as DL205 but the default is inverted. (6) FX5U FIRMWARE GATE -- needs firmware >= 1.060 for native Modbus TCP server; older firmware is client-only. Surface a clear capability error on connect. (7) FX3U PORT 502 SPLIT -- the standard FX3U-ENET cannot bind port 502 (lower port range restricted on the firmware); only FX3U-ENET-P502 can. FX3U-ENET-ADP has no Modbus at all and is a common operator mis-purchase -- driver should surface 'module does not support Modbus' as a distinct error, not 'connection refused'. (8) QJ71MT91 does NOT support FC22 (Mask Write) or FC23 (Read-Write Multiple). iQ-R and iQ-F do. Driver bulk-read optimization must gate on module capability. (9) MAX CONNECTIONS -- 16 simultaneous on Q/L/iQ-R, 8 on FX5U and FX3U-ENET. (10) STOP-mode writes -- configurable on Q/L/iQ-R/iQ-F (default = accept writes even in STOP), always rejected with exception 04 on FX3U-ENET. Per-model test differentiation section names the tests Mitsubishi_QJ71MT91_*, Mitsubishi_FX5U_*, Mitsubishi_FX3U_ENET_*, with a shared Mitsubishi_Common_* fixture for CDAB-word-order + binary-not-BCD + standard-exception-codes tests. 17 cited references including primary Mitsubishi manuals (SH-080446 for QJ71MT91, JY997D56101 for FX5, SH-081259 for iQ-R Ethernet, JY997D18101 for FX3U-ENET) plus Ignition / Kepware / Fernhill / HMS third-party driver release notes. Three unconfirmed rumours flagged explicitly: iQ-R RJ71EN71 early firmware rumoured ABCD word order (no primary source), QJ71MT91 firmware < 2010-05 FC15 odd-byte-count truncation (forum report only), FX3U-ENET firmware < 1.14 out-of-order TxId echoes under load (unreproducible on bench). Pure documentation PR -- no code, no tests. Per-quirk implementation lands in PRs 58+. Research conducted 2026-04-18.
2026-04-18 22:51:28 -04:00
Phase 2 official close-out. Closes task #209. The 2026-04-18 exit-gate-phase-2-final.md captured Phase 2 state at PR 2 merge — four High/Medium adversarial findings still OPEN, Historian port + alarm subsystem + v1 archive deletion all deferred. Since then: PR 4 closed all four findings end-to-end (High 1 Read subscription-leak, High 2 no reconnect loop, Medium 3 SubscribeAsync doesn't push frames, Medium 4 WriteValuesAsync doesn't await OnWriteComplete — mapped + resolved inline in the new doc), PR 12 landed the richer historian quality mapper, PR 13 shipped GalaxyRuntimeProbeManager with per-Platform/AppEngine ScanState subscriptions + StateChanged events forwarded through the existing OnHostStatusChanged IPC frame, PR 14 wired the alarm subsystem (GalaxyAlarmTracker advising the four alarm-state attributes per IsAlarm=true attribute, raising AlarmTransition events forwarded through OnAlarmEvent IPC frames), Phase 3 PR 18 deleted the v1 source trees, and PR 61 closed V1_ARCHIVE_STATUS.md. Phase 2 is functionally done; this commit is the bookkeeping pass. New exit-gate-phase-2-closed.md at docs/v2/implementation/ — five-stream status table (A/B/C/D/E all complete with the specific close commits named), full resolution table for every 2026-04-18 adversarial finding mapped to the PR 4 resolution, cross-cutting deferrals table marking every one resolved (Historian SDK plugin port → done, subscription push frames → done under Medium 3, Historian-backed HistoryRead → done, alarm subsystem wire-up → done, reconnect-without-recycle → done under High 2, v1 archive deletion → done). Fresh 2026-04-20 test baseline captured from the current v2 tip: 1844 passing + 29 infra-gated skips across 21 test projects, including the net48 x86 Galaxy.Host.Tests suite (107 pass) that exercises the MXAccess COM path on the dev box. Flake observed — Configuration.Tests 70/71 on first full-solution run, 71/71 on retry; logged as a known non-stable flake rather than chased because it did not reproduce. The prior exit-gate-phase-2-final.md is kept in place (historical record of the 2026-04-18 snapshot) but gets a superseded-by banner at the top pointing at the new close-out doc so future readers land on current status first. docs/v2/plan.md Phase 2 section header gains the CLOSED 2026-04-20 marker + a link to the close-out doc so the top-level plan index reflects reality. "What Phase 2 closed means for Phase 3 and later" section in the new doc captures the downstream contract: Galaxy now runs as a first-class v2 driver with the same capability-interface shape as Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient; no v1 code path remains; the 2026-04-13 stability findings persist as named regression tests under tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.E2E/StabilityFindingsRegressionTests.cs so any future refactor reintroducing them trips the test. "Outstanding — not Phase 2 blockers" section lists the four pending non-Phase-2 tasks (#177, #194, #195, #199) so nobody mistakes them for Phase 2 tail work.
2026-04-20 02:00:35 -04:00
Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research document. 485-line doc at docs/v2/s7.md mirroring the docs/v2/dl205.md template for the Siemens SIMATIC S7 family (S7-1200 / S7-1500 / S7-300 / S7-400 / ET 200SP / CP 343-1 / CP 443-1 / CP 343-1 Lean / MODBUSPN). Siemens S7 is fundamentally different from DL260: there is no fixed Modbus memory map baked into firmware -- every deployment runs MB_SERVER (S7-1200/1500/ET 200SP), MODBUSCP (S7-300/400 + CP), or MODBUSPN (S7-300/400 PN) library blocks wired up to user DBs via the MB_HOLD_REG / ADDR parameters. The driver's job is therefore to handle per-site CONFIG rather than per-family QUIRKS, and the doc makes that explicit. Key findings worth flagging for the PR 56+ implementation track: (1) S7 has no fixed memory map -- must accept per-site DriverConfig, cannot assume vendor-standard layout. (2) MB_SERVER requires NON-optimized DBs in TIA Portal; optimized DBs cause the library to return STATUS 0x8383 on every access -- the single most common S7 Modbus deployment bug in the field. (3) Word order is ABCD by default (big-endian bytes + big-endian words) across all Siemens S7 Modbus paths, which is the OPPOSITE of DL260 CDAB -- the Modbus driver's S7 profile default must be ByteOrder.BigEndian, not WordSwap. (4) MB_SERVER listens on ONE port per FB instance; multi-client support requires running MB_SERVER on 502 / 503 / 504 / ... simultaneously -- most clients assume port 502 multiplexes, which is wrong on S7. (5) CP 343-1 Lean is SERVER-ONLY and requires the separate 2XV9450-1MB00 MODBUS TCP CP library license; client mode calls return immediate error on Lean. (6) MB_SERVER does NOT filter Unit ID, accepts any value. Means the driver can't use Unit ID to detect 'direct vs gateway' topology. (7) FC23 Read-Write Multiple, FC22 Mask Write, FC20/21 File Records, FC43 Device Identification all return exception 01 Illegal Function on every S7 variant -- the driver MUST NOT attempt bulk-read optimisation via FC23 when talking to S7. (8) STOP-mode read/write behaviour is non-deterministic across firmware bands: reads may return cached data (library internal buffer), writes may succeed-silently or return exception 04 depending on CPU firmware version -- flagged as 'driver treats both as unavailable, do not distinguish'. Unconfirmed rumours flagged separately: 'V2.0+ reverses float byte order' claim (cited but not reproduced), STOP-mode caching location (folklore, no primary source). Per-model test differentiation section names the tests as S7_<model>_<behavior> matching the DL205 template convention (e.g. S7_1200_MB_SERVER_requires_non_optimized_DB, S7_343_1_Lean_rejects_client_mode, S7_FC23_returns_IllegalFunction). 31 cited references across the Siemens Industry Online Support entry-ID system (68011496 for MB_SERVER FAQ, etc.), TIA Portal library manuals, and three third-party driver vendor release notes (Kepware, Ignition, FactoryTalk). This is a pure documentation PR -- no code, no tests, no csproj changes. Per-quirk implementation lands in PRs 56+. Research conducted 2026-04-18 against latest publicly-available Siemens documentation; STOP-mode behaviour and MB_SERVER versioning specifically cross-checked against Siemens forum answers from 2024-2025.
2026-04-18 22:50:51 -04:00
Phase 2 PR 61 -- Close V1_ARCHIVE_STATUS.md; Phase 2 Streams D + E done. Purely a documentation-closure PR. The v1 archive deletion itself happened across earlier PRs: PR 2 on phase-2-stream-d archive-marked the four v1 projects (IsTestProject=false so dotnet test slnx bypassed them); Phase 3 PR 18 deleted the archived project source trees. What remained on disk was stale bin/obj residue from pre-deletion builds -- git never tracked those, so removing them from the working tree is cosmetic only (no source-file diff in this PR). What this PR actually changes: V1_ARCHIVE_STATUS.md is rewritten from 'Deletion plan (Phase 2 PR 3)' pre-work prose to a CLOSED retrospective that (a) lists all five v1 directories as deleted with check-marks (src/OtOpcUa.Host, src/Historian.Aveva, tests/Historian.Aveva.Tests, tests/Tests.v1Archive, tests/IntegrationTests), (b) names the parity-bar tests that now fill the role the 494 v1 tests originally held (Driver.Galaxy.E2E cross-FX subprocess parity + stability-findings regression, per-component *.Tests projects, Driver.Modbus.IntegrationTests, LiveStack/ smoke tests), and (c) gives the closure timeline connecting PR 2 -> Phase 3 PR 18 -> this PR 61. Also added the Modbus TCP driver family as parity coverage that didn't exist in v1 (DL205 + S7-1500 + Mitsubishi MELSEC via pymodbus sim). Stream D (retire legacy Host) has been effectively done since Phase 3 PR 18; Stream E (parity validation) is done since PR 2 landed the Driver.Galaxy.E2E project with HostSubprocessParityTests + HierarchyParityTests + StabilityFindingsRegressionTests. This PR exists to definitively close the two pending Phase 2 tasks on the task list and give future-me (or anyone picking up Phase 2 retrospectives) a single 'what actually happened' doc instead of a 'what we plan to do' prose that didn't match reality. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors, 200 warnings (all xunit1051 cancellation-token analyzer advisories, unchanged from v2 tip). No test regressions -- no source code changed.
2026-04-18 23:20:54 -04:00