`SparkplugCodec` handled scalars; `DataSet`, `Template` and `PropertySet` were skipped
with a warning. They now flatten to addressable tags (owner decision, recorded on the
issue):
Template → sibling metrics, `/`-joined, recursively: Motor → Motor/Speed, Motor/Stator/Temp
DataSet → one metric per cell, {column}/{rowIndex}: Recipe → Recipe/Step/0, Recipe/Target/1
PropertySet → node metadata, never tags — it describes a metric rather than being one
Flattening was chosen over OPC UA Structures because flattened scalars are consumable by
any client with no type dictionary, and the result mirrors how the `/raw` tree works.
**The row index is always present, including on row 0.** Emitting a bare column name for
a single-row table and an indexed one otherwise would make a tag's name depend on how many
rows the plant published — a table growing from one row to two would rename every tag
already authored against it.
**A DATA metric carries the parent's alias and no name**, so member names cannot be
composed until the alias table has resolved the parent. Expansion therefore happens in
`SparkplugIngestor.PublishStructuredMembers` — after resolution, at the single funnel both
the DATA and birth-value paths already pass through — not at decode time. The alias table
installs a binding per member so browse enumerates them and a DDATA member that omits its
datatype falls back to the birth's (guessing from the CLR type would read a signed Int32 of
-42 out of its unsigned field as 4294967254).
**Skip-and-warn survives, and refusal is whole** — the explicit requirement on the issue.
A template definition, an unnamed member, an extension value, a column/type mismatch, a
short row, or a payload past MaxDepth(5)/MaxMembers(512) refuses the ENTIRE metric. A
silently half-flattened UDT looks exactly like a complete one in the picker.
The browse picker offers the members and deliberately NOT the structured parent, which has
no value and no servable datatype. The rediscovery signature likewise tracks members rather
than the parent, or a UDT gaining a member would leave the signature unmoved.
Member paths contain `/`, which #509 already solved: the slashed name travels intact as
`metricName` while the derived tag Name is coerced to a legal RawPath segment.
Live-gated 3/3 against the Mosquitto fixture with the project-owned simulator extended to
publish a nested Template and a 2x2 DataSet. Falsified at three points: dropping the member
bindings, not expanding the parent, and refusing to flatten templates each turn exactly the
expected tests red.
Also fixes a regression from the #511 commit in the same branch: `AddOtOpcUaDriverFactories`
resolved `IDriverPrimaryRoleSource` with `GetRequiredService` but only `AddOtOpcUaRuntime`
registered it, so a graph wiring driver factories without the full runtime failed at
resolution. Two Host integration suites do exactly that and caught it; both extensions now
TryAdd the same concrete `RedundancyRoleView`, so the registration is order-independent and
the fail-loud resolve is kept.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
OtOpcUa
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
Architecture
OPC UA Clients (CLI, Desktop UI, 3rd-party)
|
v
+-------------------------------------+
| OtOpcUa.Server (.NET 10 AnyCPU) |
| address space + capability fan-out|
+-------------------------------------+
| | | | | | | |
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
|
v
mxaccessgw (sibling repo, gRPC)
|
v
MXAccess COM (x86 worker, on AVEVA box)
Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.
Prerequisites
- .NET 10 SDK (server, drivers, clients all target .NET 10)
- SQL Server reachable for the central config DB
- For Galaxy specifically: a running
mxaccessgwdeployment — see docs/v2/Galaxy.ParityRig.md - For historian read-back / alarm history / continuous historization: a running
ZB.MOM.WW.HistorianGatewaydeployment (the sole historian backend; consumed as theZB.MOM.WW.HistorianGateway.ClientgRPC package). It must runRuntimeDb:Enabled=true+RuntimeDb:EventReadsEnabled=true, and the API key must carryhistorian:read+historian:write+historian:tags:writescopes.
Quick Start
dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx
# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host
The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.
Install as Windows Services
Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.
.\scripts\install\Install-Services.ps1 `
-InstallRoot 'C:\Program Files\OtOpcUa' `
-ServiceAccount 'DOMAIN\svc-otopcua'
The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.
Client CLI
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
See docs/Client.CLI.md and docs/Client.UI.md.
Documentation
Architecture deep-dives
| Topic | Doc |
|---|---|
| OPC UA server composition, namespace fan-out, Polly invoker | docs/OpcUaServer.md |
| Address space layout | docs/AddressSpace.md |
| Read / Write dispatch (driver vs virtual vs scripted-alarm) | docs/ReadWriteOperations.md |
| Incremental sync (driver-backend rediscovery + config publishes) | docs/IncrementalSync.md |
| Service hosting (Server + Admin; external HistorianGateway backend) | docs/ServiceHosting.md |
| Security (transport, LDAP, certificates) | docs/security.md |
| Redundancy | docs/Redundancy.md |
| Status dashboard | docs/StatusDashboard.md |
Drivers
| Topic | Doc |
|---|---|
| Driver specs (per-driver capability surface, config, addressing) | docs/v2/driver-specs.md |
| Galaxy driver | docs/drivers/Galaxy.md |
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT | docs/drivers/ |
| Galaxy parity rig (mxaccessgw setup) | docs/v2/Galaxy.ParityRig.md |
| Galaxy performance + tracing | docs/v2/Galaxy.Performance.md |
Clients
| Topic | Doc |
|---|---|
| Client CLI | docs/Client.CLI.md |
| Client UI (Avalonia desktop) | docs/Client.UI.md |
v1 archive
The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.
License