Ran #491's live gate against a real ZB.MOM.WW.HistorianGateway talking to a real AVEVA Historian, and it found a production-fatal defect on the first value it ever saw. ContinuousHistorizationRecorder.OnValueChangedAsync touched `Self` after awaiting IHistorizationOutbox.AppendAsync(...).ConfigureAwait(false). ConfigureAwait(false) discards Akka's ActorTaskScheduler synchronization context, so `Self` — which reads ActorBase.Context — threw NotSupportedException. The throw escaped into supervision, which RESTARTED the actor; because production seeds an EMPTY ref set (the deployed set arrives later via UpdateHistorizedRefs), the restart silently discarded every historized ref. Net effect: one value captured, then nothing, with no further error to show for it. Fixed by capturing `IActorRef self = Self` before the await — the idiom the GetStatus handler already applied to Sender. Thirteen unit tests missed it because InMemoryOutbox.AppendAsync returned ValueTask.CompletedTask: a completed ValueTask never yields, so the continuation ran inline with the context still installed. The production FasterLog outbox fsyncs per entry and does yield. The first regression test was itself vacuous — `await Task.Yield()` posts back to the CAPTURED context, so the append still completed on the actor thread and reverting the fix left the test green. The fake must complete on a POOL thread (Task.Delay(1).ConfigureAwait(false)), as a real fsync does; with that, reverting the fix reddens exactly one test. The rig could not run this gate at all: docker-dev carried ServerHistorian__* but no ContinuousHistorization__* keys, so the recorder could never spawn. Both centrals now carry them (default OFF — the recorder needs ContinuousHistorization:Enabled AND ServerHistorian:Enabled), with the outbox on the per-node named volume so it survives a container recreate. ServerHistorian__UseTls was hard-coded true and is now parameterized; a plaintext h2c gateway was unreachable without it. Gate results: outbox append, drain, WriteLiveValues accepted by a real historian, and restart convergence (capture resumes after a restart with no new deployment) all pass. The read-back hop is NOT proven — the LAN historian accepts writes but serves no reads under a "License violation: Database tag count exceeds license tag count", and the licensed corporate one needs the VPN. EnsureTags provisioning is likewise unexercised there (RemoteGrpc-only, and that CAP is not listening). #491 stays open for the read-back hop alone. Also recorded, not fixed: the recorder has NO Primary gate, unlike the alarm store-and-forward sink, so both nodes of a redundant pair send duplicate live values. Gating it would introduce a failover window with no capture — that is a design decision, not a cleanup. Evidence: docs/plans/2026-08-01-continuous-historization-live-gate.md Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
OtOpcUa documentation
Two tiers of documentation live here:
- Current reference at the top level (
docs/*.md) — describes what's shipped today. Start here for operator + integrator reference. - Implementation history + design notes at
docs/v2/*.md— the authoritative plan + decision log the current reference is built from. Start here when you need the why behind an architectural choice, or when a top-level doc says "see plan.md § X".
The project was originally called LmxOpcUa (a single-driver Galaxy/MXAccess OPC UA server) and has since become OtOpcUa, a multi-driver OPC UA server platform. Any lingering LmxOpcUa-string in a path you see in docs is a deliberate residual (executable name lmxopcua-cli, client PKI folder {LocalAppData}/LmxOpcUaClient/) — fixing those requires migration shims + is tracked as follow-ups.
Platform overview
v2 (2026-05-26): the separate
OtOpcUa.Server+OtOpcUa.Adminservices fused into a single role-gatedOtOpcUa.Hostbinary, joined by an Akka.NET cluster. See v2 design for the architectural decision.
- Core owns shared abstractions (driver capability contracts, scripting, virtual tags, alarm historian).
- Drivers plug in via capability interfaces in
ZB.MOM.WW.OtOpcUa.Core.Abstractions:IDriver,IReadable,IWritable,ITagDiscovery,ISubscribable,IHostConnectivityProbe,IAlarmSource,IHistoryProvider,IPerCallHostResolver. Each driver opts into whichever it supports. - Host (
src/Server/ZB.MOM.WW.OtOpcUa.Host) is the single fused binary (.NET 10, AnyCPU).OTOPCUA_ROLESenv decides what to mount:admin(Blazor + control-plane singletons),driver(OPC UA endpoint + per-node actors), or both. See ServiceHosting.md. - Cluster + ControlPlane + Runtime + AdminUI + Security sit between Core and Host. The cluster glues per-node actors into one logical fleet; the control-plane singletons (deploy coordinator, audit writer, redundancy state) live on the admin role-leader. See Redundancy.md.
- The Galaxy driver still reaches MXAccess via gRPC to a separately-installed mxaccessgw sidecar (sibling repo).
Where to find what
Architecture + data-path reference
| Doc | Covers |
|---|---|
| OpcUaServer.md | Top-level server architecture — Core, driver dispatch, Config DB, generations |
| AddressSpace.md | GenericDriverNodeManager + ITagDiscovery + IAddressSpaceBuilder |
| ReadWriteOperations.md | OPC UA Read/Write → CapabilityInvoker → IReadable/IWritable |
| DriverLifecycle.md | Server-side driver lifecycle + infrastructure contracts (IDriverFactory, IDriverProbe, IDriverHealthPublisher, IDriverConfigEditor, IHistorianDataSource) + the Commons library |
| Subscriptions.md | Monitored items → ISubscribable + per-driver subscription refcount (v1 archive) |
| AlarmTracking.md | IAlarmSource + AlarmSurfaceInvoker + OPC UA alarm conditions — native Galaxy alarms end-to-end (live) |
| AlarmTracking.md | Original alarm-tracking write-up (v1 archive) |
| AlarmHistorian.md | Core.AlarmHistorian store-and-forward sink — LocalDbStoreAndForwardSink, the replicated alarm_sf_events buffer + Primary-only drain, IAlarmHistorianWriter, dead-letter/retry/eviction |
| DataTypeMapping.md | Per-driver DriverAttributeInfo → OPC UA variable types (v1 archive — live mapping is in src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Galaxy/Browse/DataTypeMap.cs) |
| IncrementalSync.md | Address-space rebuild on redeploy + sp_ComputeGenerationDiff |
| HistoricalDataAccess.md | IHistoryProvider as a per-driver optional capability (v1 archive) |
| VirtualTags.md | Core.Scripting + Core.VirtualTags — Roslyn script sandbox, engine, dispatch alongside driver tags |
| ScriptEditor.md | Monaco script editor — Roslyn-backed IntelliSense (completions, diagnostics, hover, tag-path) for C# virtual-tag scripts; AdminUI/ScriptAnalysis/ backend |
| ScriptedAlarms.md | Core.ScriptedAlarms — script-predicate IAlarmSource + Part 9 state machine |
One Core subsystem is shipped without a dedicated top-level doc; see the section in the linked doc:
| Project | See |
|---|---|
Analyzers (Roslyn OTOPCUA0001) |
security.md § OTOPCUA0001 Analyzer |
Drivers
| Doc | Covers |
|---|---|
| drivers/README.md | Index of the eight shipped drivers + capability matrix |
| drivers/Galaxy.md | Galaxy driver — in-process gRPC client to the mxaccessgw sidecar |
| v1/drivers/Galaxy-Repository.md | Galaxy-specific discovery via the ZB SQL database (v1 archive — the gateway owns this path now) |
For Modbus / S7 / AB CIP / AB Legacy / TwinCAT / FOCAS / OPC UA Client specifics, see v2/driver-specs.md.
Operational
| Doc | Covers |
|---|---|
| Configuration.md | Live appsettings + environment-variable reference (current state) |
| Configuration.md | appsettings bootstrap + Config DB + Admin UI draft/publish (v1 archive — OTOPCUA_GALAXY_* env vars now live in mxaccessgw config) |
| Uns.md | The global /uns master tree — manage Area/Line/Equipment/Tag/VirtualTag fleet-wide; replaces the per-cluster UNS/Equipment/Tags tabs |
| security.md | Transport security profiles, LDAP auth, ACL trie, role grants, OTOPCUA0001 analyzer |
| Redundancy.md | RedundancyStateActor (cluster-scoped singleton), ServiceLevelCalculator, IRedundancyRoleView, per-cluster meshes, Prometheus metrics |
| Reservations.md | Fleet-wide ZTag / SAPID external-ID reservations — publish-time claim, release flow |
| ServiceHosting.md | Single fused OtOpcUa.Host binary install/uninstall with OTOPCUA_ROLES gating; the historian backend is the external HistorianGateway |
| StatusDashboard.md | Pointer — superseded by v2/admin-ui.md |
Client tooling
| Doc | Covers |
|---|---|
| Client.CLI.md | otopcua-cli — OPC UA command-line client |
| Client.UI.md | Avalonia desktop client |
| DriverClis.md | Driver test-client CLIs — index + shared commands |
| Driver.Modbus.Cli.md | otopcua-modbus-cli — Modbus-TCP |
| Driver.AbCip.Cli.md | otopcua-abcip-cli — ControlLogix / CompactLogix / Micro800 / GuardLogix |
| Driver.AbLegacy.Cli.md | otopcua-ablegacy-cli — SLC / MicroLogix / PLC-5 (PCCC) |
| Driver.S7.Cli.md | otopcua-s7-cli — Siemens S7-300 / S7-400 / S7-1200 / S7-1500 |
| Driver.TwinCAT.Cli.md | otopcua-twincat-cli — Beckhoff TwinCAT 2/3 ADS |
| Driver.FOCAS.Cli.md | otopcua-focas-cli — Fanuc FOCAS/2 CNC |
Requirements
| Doc | Covers |
|---|---|
| reqs/HighLevelReqs.md | HLRs — numbered system-level requirements |
| reqs/OpcUaServerReqs.md | OPC UA server-layer reqs |
| v1/reqs/ServiceHostReqs.md | Per-process hosting reqs (v1 archive — only OtOpcUa server hosting remains in scope post-PR-7.2) |
| reqs/ClientRequirements.md | Client CLI + UI reqs |
| v1/reqs/GalaxyRepositoryReqs.md | Galaxy-scoped repository reqs (v1 archive — owned by mxaccessgw today) |
| v1/reqs/MxAccessClientReqs.md | Galaxy-scoped MXAccess reqs (v1 archive — owned by mxaccessgw today) |
| reqs/StatusDashboardReqs.md | Pointer — superseded by Admin UI |
Implementation history (docs/v2/)
Design decisions + phase plans + execution notes. Load-bearing cross-references from the top-level docs:
- v2/plan.md — authoritative v2 vision doc + numbered decision log (referenced as "decision #N" elsewhere)
- v2/admin-ui.md — Admin UI spec
- v2/acl-design.md — data-plane ACL + permission-trie design (Phase 6.2)
- v2/config-db-schema.md — Config DB schema reference
- v2/driver-specs.md — per-driver addressing + quirks for every shipped protocol
- v2/dev-environment.md — dev-box bootstrap
- v2/test-data-sources.md — integration-test simulator matrix (includes the pinned libplctag
ab_serverversion for AB CIP tests) - v2/multi-host-dispatch.md — per-PLC circuit breakers (Phase 6.1 decision #144)
- v2/v2-release-readiness.md — release-readiness tracker
- v2/phase-7-status.md — Phase 7 reconciliation: what shipped vs. the plan, and the five remaining gaps
- v2/implementation/phase--.md — per-phase execution plans with exit-gate evidence
v1 archive
The v1 in-process MXAccess architecture (Galaxy.Host + Galaxy.Proxy + Galaxy.Shared, .NET 4.8 x86 COM, the OtOpcUaGalaxyHost Windows service) was retired in PR 7.2 (2026-04-30, commit ae7106d). Docs that described that shape are kept under v1/ as historical record — see v1/README.md for the index.