a0b5095b3b
The cross-driver README still described MQTT as pre-P2 — "Sparkplug B is P2
(`mode: SparkplugB` is a placeholder)" and "Sparkplug B has no fixture yet (P2)".
Both were false as of the P2 merge (c3a2b0f7): SparkplugB is a fully implemented
mode and the live suite is 15 tests (7 plain + 8 Sparkplug) against a
project-owned C# edge-node simulator. Mqtt.md and the scadaproj index were both
already correct; only this file missed the P2 sweep.
Filed the nine Known-gaps rows as tracking issues and linked them, so the table
stops being the only record of them:
#507 IRediscoverable is inert in v3 (platform gap — also Galaxy/TwinCAT/AbCip)
#508 write-through (IWritable) — NCMD/DCMD + plain publish
#509 a metric name containing '/' cannot be browse-committed
#510 _canRebirth captured at browse-open — reaped session still draws button
#511 Sparkplug primary-host STATE publishing (ActAsPrimaryHost)
#512 .Browser references .Driver — extract the client-options builder
#513 editor writes a meaningless payloadFormat into a Sparkplug blob
#514 Request-rebirth unarmable on a plant that birthed before the window
#515 DataSet / Template / PropertySet metric support
#507 is the one worth reading: it is a v3 platform gap, not an MQTT bug —
DriverHostActor.HandleDiscoveredNodes hard-returns, so every IRediscoverable
driver fires into a void and the edge gaining a point needs a redeploy to show up.
No code change; docs + issue links only.
79 lines
14 KiB
Markdown
79 lines
14 KiB
Markdown
# Drivers
|
||
|
||
OtOpcUa is a multi-driver OPC UA server. The Core (`ZB.MOM.WW.OtOpcUa.Core` + `Core.Abstractions` + `Server`) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through **capability interfaces** defined in `src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/`:
|
||
|
||
- `IDriver` — lifecycle (`InitializeAsync`, `ReinitializeAsync`, `ShutdownAsync`, `GetHealth`)
|
||
- `IReadable` / `IWritable` — one-shot reads and writes
|
||
- `ITagDiscovery` — address-space enumeration
|
||
- `ISubscribable` — driver-pushed data-change streams
|
||
- `IHostConnectivityProbe` — per-host reachability events
|
||
- `IPerCallHostResolver` — multi-host drivers that route each call to a target endpoint at dispatch time
|
||
- `IAlarmSource` — driver-emitted OPC UA A&C events
|
||
- `IHistoryProvider` — driver-side raw / processed / at-time / events HistoryRead (see [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md))
|
||
- `IRediscoverable` — driver-initiated address-space rebuild notifications
|
||
- `IHistorianDataSource` — server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-side `IHistoryProvider` HistoryRead path
|
||
|
||
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through `CapabilityInvoker` (`Core/Resilience/CapabilityInvoker.cs`), which wraps it in a Polly pipeline keyed on `(DriverInstanceId, HostName, DriverCapability)`. The `OTOPCUA0001` analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
|
||
|
||
Driver type metadata is registered at startup in `DriverTypeRegistry` (`src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs`). The registry records each type's allowed namespace kinds (`Equipment` / `SystemPlatform` / `Simulated`), its JSON Schema for `DriverConfig` / `DeviceConfig` / `TagConfig` columns, and its stability tier per [docs/v2/driver-stability.md](../v2/driver-stability.md).
|
||
|
||
## Ground-truth driver list
|
||
|
||
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|
||
|--------|--------------|:----:|----------------|--------------|---------------|
|
||
| [Galaxy](Galaxy.md) | `Driver.Galaxy` (+ `.Browser`, `.Contracts`) | A | gRPC to the external `mxaccessgw` gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process `Galaxy.{Shared, Host, Proxy}` + named-pipe Windows service. Native MxAccess alarms work end-to-end |
|
||
| [Modbus TCP](Modbus.md) | `Driver.Modbus` | A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared `PollGroupEngine`. DL205 PLCs are covered by `AddressFormat=DL205` (octal V/X/Y/C/T/CT translation) — no separate driver |
|
||
| [Siemens S7](S7.md) | `Driver.S7` | A | [S7netplus](https://github.com/S7NetPlus/s7netplus) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus `Plc` instance per PLC serialized with `SemaphoreSlim` — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
|
||
| [AB CIP](AbCip.md) | `Driver.AbCip` | A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the `@tags` walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
|
||
| [AB Legacy](AbLegacy.md) | `Driver.AbLegacy` | A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (`N7:0`, `F8:0`) — no symbol table, tag list is user-authored in the config DB |
|
||
| [TwinCAT](TwinCAT.md) | `Driver.TwinCAT` | B | Beckhoff `TwinCAT.Ads` (`TcAdsClient`) | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers `ValueChangedCallback` events the driver forwards straight to `ISubscribable.OnDataChange` without polling. Symbol tree uploaded via `SymbolLoaderFactory` |
|
||
| [FOCAS](FOCAS.md) | `Driver.FOCAS` | A | Pure-managed `FocasWireClient` — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | `IWritable` is implemented but read-only by design — `WriteAsync` returns `BadNotWritable` for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
|
||
| [OPC UA Client](OpcUaClient.md) | `Driver.OpcUaClient` | B | OPCFoundation `Opc.Ua.Client` | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side `IHistoryProvider` (forwards HistoryRead to the upstream server). Opens a single `Session` against a remote OPC UA server and re-exposes its address space. Owns its own `ApplicationConfiguration` (distinct from `Client.Shared`) because it's always-on with keep-alive + `TransferSubscriptions` across SDK reconnect, not an interactive CLI |
|
||
| [MQTT](Mqtt.md) | `Driver.Mqtt` (+ `.Browser`, `.Contracts`) | A | [MQTTnet 5](https://github.com/dotnet/MQTTnet) | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | **Push, not poll, and read-only** — the broker delivers PUBLISH frames the driver forwards straight to `ISubscribable.OnDataChange`; `IReadable` serves the last retained/received value from cache, and there is **no `IWritable`** (nothing publishes back). Subscriptions are indexed **by topic filter, not by topic**, so wildcard tags survive a reconnect. A rejected CONNACK throws `MqttConnectRejectedException`: unrecoverable codes → `Faulted` + supervisor stop, transient → retry. **Two modes:** `Plain` binds a tag to a concrete topic + JSON path; `SparkplugB` decodes vendored Eclipse-Tahu protobuf under one `spBv1.0/{groupId}/#` subscription and binds by the `group/edgeNode/device?/metric` tuple (birth/alias/seq-gap state machine, death→STALE, scoped rebirth NCMD). `IRediscoverable` fires on a DBIRTH but is **inert platform-side** — see [#507](https://gitea.dohertylan.com/dohertj2/lmxopcua/issues/507) |
|
||
| [Historian.Gateway](../Historian.md) | `Driver.Historian.Gateway` | — | `ZB.MOM.WW.HistorianGateway.Client` gRPC (`historian_gateway.v1`) | IHistorianDataSource (server-side read backend) + alarm `SendEvent` writer + `WriteLiveValues` recorder + `IHistorianProvisioning` | Not a tag driver — the sole historian backend. Registers `GatewayHistorianDataSource : IHistorianDataSource` for HistoryRead and serves alarm-write + continuous historization through the gateway. No `IDriver`/`ITagDiscovery` surface. (The retired Wonderware sidecar backend it replaced is documented at [Historian.Wonderware.md](Historian.Wonderware.md).) |
|
||
|
||
## Per-driver documentation
|
||
|
||
- **Galaxy** has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
|
||
- [Galaxy.md](Galaxy.md) — gateway gRPC bridge, hierarchy source, runtime probes
|
||
- [Galaxy-Repository.md](../v1/drivers/Galaxy-Repository.md) — ZB SQL reader, `LocalPlatform` scope filter, change detection (v1 archive)
|
||
|
||
- **FOCAS** has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
|
||
- [FOCAS.md](FOCAS.md) — deployment, config, capability surface, alarm projection, troubleshooting
|
||
|
||
- **Modbus TCP**, **AB CIP**, **AB Legacy**, **Siemens S7**, **TwinCAT**, **OPC UA Client**, and **MQTT** each have a per-driver overview page:
|
||
- [Modbus.md](Modbus.md) — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
|
||
- [AbCip.md](AbCip.md) — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
|
||
- [AbLegacy.md](AbLegacy.md) — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
|
||
- [S7.md](S7.md) — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
|
||
- [TwinCAT.md](TwinCAT.md) — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
|
||
- [OpcUaClient.md](OpcUaClient.md) — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
|
||
- [Mqtt.md](Mqtt.md) — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding, `#`-observation browser, CONNACK-rejection semantics, **Sparkplug B** (birth/alias/seq/rebirth state machine, birth-driven browse picker, death→STALE), and the **Known gaps** table
|
||
|
||
- **Historian.Gateway** (server-side historian backend, not a tag driver) is documented in the main guide:
|
||
- [../Historian.md](../Historian.md) — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (`SendEvent`), continuous historization (`WriteLiveValues`), `EnsureTags` provisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: [Historian.Wonderware.md](Historian.Wonderware.md).)
|
||
|
||
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path; that file is the authoritative per-driver reference.
|
||
|
||
## Test-fixture coverage maps
|
||
|
||
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
|
||
|
||
- [AB CIP](AbServer-Test-Fixture.md) — Dockerized `ab_server` (multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only
|
||
- [Modbus](Modbus-Test-Fixture.md) — Dockerized `pymodbus` + per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped
|
||
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
|
||
- [AB Legacy](AbLegacy-Test-Fixture.md) — Dockerized `ab_server` PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. `/1,0` cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (`B3:0/5`) still surface BadState — real HW / RSEmulate 500 for those
|
||
- [TwinCAT](TwinCAT-Test-Fixture.md) — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via `FakeTwinCATClient` with native-notification harness
|
||
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
|
||
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — Dockerized `opc-plc` integration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mocked `Session`
|
||
- [MQTT](Mqtt-Test-Fixture.md) — Dockerized `eclipse-mosquitto` with **TLS + real auth on both listeners (no anonymous fallback)** + a JSON-publisher sidecar; env-gated live suite (**15 tests**) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a **project-owned C# edge-node simulator** on the `sparkplug` compose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, so `docker restart otopcua-sparkplug-sim` is how you force a fresh one
|
||
- [Galaxy](../v1/drivers/Galaxy-Test-Fixture.md) — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
|
||
|
||
## Related cross-driver docs
|
||
|
||
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
|
||
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
|
||
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
|
||
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
|
||
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.
|