Files
lmxopcua/docs/drivers/S7-Test-Fixture.md
Joseph Doherty 0e1dcc119e Remove native-launcher fallbacks for the four Dockerized fixtures — Docker is the only supported path for Modbus / S7 / AB CIP / OpcUaClient integration. Native paths stay in place only where Docker isn't compatible (Galaxy: MXAccess COM + Windows-only; TwinCAT: Beckhoff runtime vs Hyper-V; FOCAS: closed-source Fanuc Fwlib32.dll; AB Legacy: PCCC has no OSS simulator). Simplifies the fixture landscape + removes the "which path do I run" ambiguity; removes two full native-launcher directories + the AB CIP native-spawn path; removes the parallel profile-as-CLI-arg-builder code from AbServerFixture.
Modbus — deletes tests/.../Modbus.IntegrationTests/Pymodbus/ (serve.ps1, standard.json, dl205.json, mitsubishi.json, s7_1500.json, README.md). Profile JSONs live only under Docker/profiles/ now. Docker/README.md loses its "Native-Python fallback" section; docs/drivers/Modbus-Test-Fixture.md "What the fixture is" bullet flipped from "primary launcher is Docker, native fallback under Pymodbus/" to "Docker is the only supported launch path".

S7 — deletes tests/.../S7.IntegrationTests/PythonSnap7/ (server.py, s7_1500.json, serve.ps1, README.md). Docker/README.md loses "Native-Python fallback"; docs/drivers/S7-Test-Fixture.md updated to match.

AB CIP — the biggest simplification because the native-binary spawn had the most code. AbServerFixture.cs rewrites: drops Process management (no more Process _proc + Kill/WaitForExit), drops LocateBinary() PATH lookup, drops the IAsyncLifetime initialize-spawns-server behavior. Fixture is now a thin TCP probe against localhost:44818 (or AB_SERVER_ENDPOINT override) — same shape as Snap7ServerFixture / ModbusSimulatorFixture / OpcPlcFixture. IsServerAvailable() simplifies to a single 500 ms probe. AbServerProfile.cs drops AbServerPlcArg + SeedTags + BuildCliArgs + ToCliSpec + the entire AbServerSeedTag record — the compose file is the canonical source of truth for which tags + which --plc mode each family gets; the profile record now carries just Family + ComposeProfile (matches the docker-compose service key) + Notes. KnownProfiles.ForFamily + .All stay for tests that iterate families. AbServerProfileTests.cs rewrites to match: drops BuildCliArgs_* + ToCliSpec_* + SeedTags_* tests; keeps the family-coverage contract tests + verifies the ComposeProfile strings match compose-file service names (a typo in either surfaces as a unit-test failure, not a silent "wrong family booted" at runtime). Docker/README.md loses "Native-binary fallback" section; docs/drivers/AbServer-Test-Fixture.md "What the fixture is" flipped to Docker-only with clearer skip rules.

dev-environment.md §Docker fixtures — the "Native fallbacks" subsection goes away; replaced with a one-line note that Docker is the only supported path for these four fixtures + a fresh clone needs Docker Desktop and nothing else.

Verified: whole-solution build 0 errors, AB CIP profile unit tests 6/6, AB CIP Docker smoke 4/4 (all family theory rows), S7 Docker smoke 3/3. Container lifecycle clean. The deleted native code surface was already redundant — every fixture the native paths served is now covered by Docker; keeping them invited drift between the two paths (the original AB CIP native profile had three undetected bugs per the #162 commit message: case-sensitive --plc, bracket tag notation, --path=1,0 requirement — noise the Docker path now avoids by never running the buggy code).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-20 12:27:44 -04:00

122 lines
5.2 KiB
Markdown

# Siemens S7 test fixture
Coverage map + gap inventory for the S7 driver.
**TL;DR:** S7 now has a wire-level integration fixture backed by
[python-snap7](https://github.com/gijzelaerr/python-snap7)'s `Server` class
(task #216). Atomic reads (u16 / i16 / i32 / f32 / bool-with-bit) + DB
write-then-read round-trip are exercised end-to-end through S7netplus +
real ISO-on-TCP on `localhost:1102`. Unit tests still carry everything
else (address parsing, error-branch handling, probe-loop contract). Gaps
remaining are variant-quirk-shaped: Optimized-DB symbolic access, PG/OP
session types, PUT/GET-disabled enforcement — all need real hardware.
## What the fixture is
**Integration layer** (task #216):
`tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/` stands up a
python-snap7 `Server` via `Docker/docker-compose.yml --profile s7_1500`
on `localhost:1102` (pinned `python:3.12-slim-bookworm` base +
`python-snap7>=2.0`). Docker is the only supported launch path.
`Snap7ServerFixture` probes the port at collection init + skips with a
clear message when unreachable (matches the pymodbus pattern).
`server.py` (baked into the image under `Docker/`) reads a JSON profile
+ seeds DB/MB bytes at declared offsets; seeds are typed (`u16` / `i16`
/ `i32` / `f32` / `bool` / `ascii` for S7 STRING).
**Unit layer**: `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/` covers
everything the wire-level suite doesn't — address parsing, error
branches, probe-loop contract. All tests tagged
`[Trait("Category", "Unit")]`.
The driver ctor change that made this possible:
`Plc(CpuType, host, port, rack, slot)` — S7netplus 0.20's 5-arg overload
— wires `S7DriverOptions.Port` through so the simulator can bind 1102
(non-privileged) instead of 102 (root / Firewall-prompt territory).
## What it actually covers
### Integration (python-snap7, task #216)
- `S7_1500SmokeTests.Driver_reads_seeded_u16_through_real_S7comm` — DB1.DBW0
read via real S7netplus over TCP + simulator; proves handshake + read path
- `S7_1500SmokeTests.Driver_reads_seeded_typed_batch` — i16, i32, f32,
bool-with-bit in one batch call; proves typed decode per S7DataType
- `S7_1500SmokeTests.Driver_write_then_read_round_trip_on_scratch_word`
`DB1.DBW100` write → read-back; proves write path + buffer visibility
### Unit
- `S7AddressParserTests` — S7 address syntax (`DB1.DBD0`, `M10.3`, `IW4`, etc.)
- `S7DriverScaffoldTests``IDriver` lifecycle (init / reinit / shutdown / health)
- `S7DriverReadWriteTests` — error paths (uninitialized read/write, bad
addresses, transport exceptions)
- `S7DiscoveryAndSubscribeTests``ITagDiscovery.DiscoverAsync` + polled
`ISubscribable` contract with the shared `PollGroupEngine`
Capability surfaces whose contract is verified: `IDriver`, `ITagDiscovery`,
`IReadable`, `IWritable`, `ISubscribable`, `IHostConnectivityProbe`.
Wire-level surfaces verified: `IReadable`, `IWritable`.
## What it does NOT cover
### 1. Wire-level anything
No ISO-on-TCP frame is ever sent during the test suite. S7netplus is the only
wire-path abstraction and it has no in-process fake mode; the shipping choice
was to contract-test via `IS7Client` rather than patch into S7netplus
internals.
### 2. Read/write happy path
Every `S7DriverReadWriteTests` case exercises error branches. A successful
read returning real PLC data is not tested end-to-end — the return value is
whatever the fake says it is.
### 3. Mailbox serialization under concurrent reads
The driver's `SemaphoreSlim` serializes S7netplus calls because the S7 CPU's
comm mailbox is scanned at most once per cycle. Contention behavior under
real PLC latency is not exercised.
### 4. Variant quirks
S7-1200 vs S7-1500 vs S7-300/400 connection semantics (PG vs OP vs S7-Basic)
not differentiated at test time.
### 5. Data types beyond the scalars
UDT fan-out, `STRING` with length-prefix quirks, `DTL` / `DATE_AND_TIME`,
arrays of structs — not covered.
## When to trust the S7 tests, when to reach for a rig
| Question | Unit tests | Real PLC |
| --- | --- | --- |
| "Does the address parser accept X syntax?" | yes | - |
| "Does the driver lifecycle hang / crash?" | yes | yes |
| "Does a real read against an S7-1500 return correct bytes?" | no | yes (required) |
| "Does mailbox serialization actually prevent PG timeouts?" | no | yes (required) |
| "Does a UDT fan-out produce usable member variables?" | no | yes (required) |
## Follow-up candidates
1. **Snap7 server** — [Snap7](https://snap7.sourceforge.net/) ships a
C-library-based S7 server that could run in-CI on Linux. A pinned build +
a fixture shape similar to `ab_server` would give S7 parity with Modbus /
AB CIP coverage.
2. **Plcsim Advanced** — Siemens' paid emulator. Licensed per-seat; fits a
lab rig but not CI.
3. **Real S7 lab rig** — cheapest physical PLC (CPU 1212C) on a dedicated
network port, wired via self-hosted runner.
Without any of these, S7 driver correctness against real hardware is trusted
from field deployments, not from the test suite.
## Key fixture / config files
- `tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/` — unit tests only, no harness
- `src/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs` — ctor takes
`IS7ClientFactory` which tests fake; docstring lines 8-20 note the deferred
integration fixture