Joseph Doherty 919009c5ef fix(ablegacy): stamp health from the injectable Clock; drop the redundant per-project TreatWarningsAsErrors (lmxopcua#768)
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).

Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:40:07 -05:00

52 lines
3.6 KiB
XML

<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<IsPackable>false</IsPackable>
<IsTestProject>true</IsTestProject>
<RootNamespace>ZB.MOM.WW.OtOpcUa.Runtime.Tests</RootNamespace>
</PropertyGroup>
<ItemGroup>
<!-- xunit v2 because Akka.TestKit.Xunit2 pins to it (same as ControlPlane.Tests). -->
<PackageReference Include="xunit"/>
<PackageReference Include="Shouldly"/>
<PackageReference Include="Microsoft.NET.Test.Sdk"/>
<PackageReference Include="Akka.TestKit.Xunit2"/>
<PackageReference Include="Microsoft.EntityFrameworkCore.InMemory"/>
<PackageReference Include="xunit.runner.visualstudio">
<PrivateAssets>all</PrivateAssets>
<IncludeAssets>runtime; build; native; contentfiles; analyzers; buildtransitive</IncludeAssets>
</PackageReference>
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\..\src\Server\ZB.MOM.WW.OtOpcUa.Runtime\ZB.MOM.WW.OtOpcUa.Runtime.csproj"/>
<!-- TEST-ONLY reference to Core (Polly): lets the resilience-wiring guards construct the REAL
CapabilityInvoker. The PRODUCTION Runtime assembly stays Polly-free (consumes the
IDriverCapabilityInvoker seam) — this reference is in the test project only. -->
<ProjectReference Include="..\..\..\src\Core\ZB.MOM.WW.OtOpcUa.Core\ZB.MOM.WW.OtOpcUa.Core.csproj"/>
<ProjectReference Include="..\..\..\src\Core\ZB.MOM.WW.OtOpcUa.Configuration\ZB.MOM.WW.OtOpcUa.Configuration.csproj"/>
<ProjectReference Include="..\..\..\src\Core\ZB.MOM.WW.OtOpcUa.Commons\ZB.MOM.WW.OtOpcUa.Commons.csproj"/>
<!-- WP7: the real Calculation driver, so the dependency-flow integration test drives values through
the real DependencyMuxActor → DependencyConsumerMuxAdapter → CalculationDriver path. -->
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Calculation\ZB.MOM.WW.OtOpcUa.Driver.Calculation.csproj"/>
<!-- Gitea #647: the real FOCAS driver, so the native-alarm end-to-end test proves a CNC alarm reaches the
host's Part 9 condition (ForwardNativeAlarm → NativeAlarmProjector), not merely that it was raised. -->
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.FOCAS\ZB.MOM.WW.OtOpcUa.Driver.FOCAS.csproj"/>
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.AbCip\ZB.MOM.WW.OtOpcUa.Driver.AbCip.csproj"/>
<!-- Gitea #656: the real Galaxy (over a scripted gateway alarm stream) and OpcUaClient drivers, so the
re-statement end-to-end tests prove what reaches the host's /alerts rows and Part 9 conditions. -->
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.Galaxy\ZB.MOM.WW.OtOpcUa.Driver.Galaxy.csproj"/>
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.csproj"/>
<!-- Lane S7 review I-1: the real S7 driver (over a scripted IS7Plc), so the comms-loss watchdog test proves an
access-denied (PUT/GET disabled) CPU is NOT reconnected every 90 s, against the real actor. -->
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.S7\ZB.MOM.WW.OtOpcUa.Driver.S7.csproj"/>
</ItemGroup>
<ItemGroup>
<!-- Shared bind-race retry helper for tests that boot a real SDK server on a probed port. -->
<Compile Include="..\ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests\OpcUaHostStart.cs" Link="OpcUaHostStart.cs"/>
</ItemGroup>
</Project>