52708bff52
MAJOR-1: R4's exact element-type match refused ScadaBridge's CLR-list writes (its element types are only Boolean/Int32/Float/Double/String/ DateTime) to every Int16/UInt16/Byte/UInt32/Int64/UInt64 array node and a Double list to a Float array. EvaluateEquipmentWriteStructure now converts a numeric array of another numeric element type element-wise, CHECKED, into the node's element type and hands the converted array back through OnEquipmentTagWrite's ref value, so the node stores and the driver receives the node's own type. Any out-of-range, fractional-to-integer, NaN/Inf-to- integer or Float-overflowing element refuses the whole write BadTypeMismatch (nothing dispatched) - so the UInt32 -> Int32 bit reinterpretation stays closed. Non-numeric mismatches stay refused. The wrong 'no client relies on a looser rule' comment is corrected. MINOR-1: the array-value-to-scalar-node refusal broke writes back to browse-committed array tags (committed scalar, isArray never set) on pass-through drivers. It now applies only when the owning driver's scalar encoder cannot take an array (DriverArrayWriteSupport. RefusesArrayValueOnScalarTag: Modbus, S7), carried RawTagPlan. ScalarRefusesArrayValue / UnsReferenceVariable.BackingScalarRefusesArrayValue -> EnsureVariable(refuseArrayOnScalar) -> a per-node set in the node manager. OpcUaClient/Galaxy/others keep pre-#610 dispatch. Not on the classifier whitelist (driver-type edit rebuilds); a mirror whose flag changes is recreated, not updated in place. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe