Close the Wave-A M1 gap: the sink surface had no way to wire the mandated
cross-tree Organizes reference from each UNS reference Variable to its backing
Raw node, forcing WP3 to reopen the frozen surface. Add a dedicated
realm-qualified AddReference method instead.
- IOpcUaAddressSpaceSink.AddReference(sourceNodeId, sourceRealm, targetNodeId,
targetRealm, referenceType="Organizes"): realm-qualified both ends; idempotent;
a missing endpoint is a logged no-op (never throws) so a mid-rebuild race can't
fault a deploy. Base-interface capability (no surgical sniff, no transitional
default — WP3 wires it explicitly per UNS reference variable).
- SdkAddressSpaceSink forwards to the node manager; DeferredAddressSpaceSink
forwards unconditionally (like EnsureFolder); NullOpcUaAddressSpaceSink no-ops.
- OtOpcUaNodeManager.AddReference: resolve both nodes by full ns-qualified key
(variable/folder/condition via ResolveNodeState), guard both-exist, then wire
the edge bidirectionally (forward Organizes on source, inverse on target) with a
ReferenceExists idempotency guard + ClearChangeMasks on mutated sides. Reference
type resolved by ResolveReferenceType (Organizes default). Added internal
GetNodeReferences test/diagnostic accessor.
- Reflection guard: the exhaustive-forwarding test + the realm-discriminator guard
auto-cover AddReference (it has two AddressSpaceRealm params) — no edit needed.
- New SdkAddressSpaceSinkTests: Organizes UNS→Raw edge created bidirectionally +
idempotent; missing endpoint is a safe no-op.
- All 15 IOpcUaAddressSpaceSink test doubles gain the AddReference no-op so the
solution still builds.
Build: dotnet build ZB.MOM.WW.OtOpcUa.slnx = 0 errors.
Tests: Commons.Tests 310/310; OpcUaServer.Tests 337 passed / 4 pre-existing skips.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Register both v3 namespaces (Raw first, UNS second) on OtOpcUaNodeManager and
thread an AddressSpaceRealm discriminator through every node-naming sink method
so a bare node id is resolved to the correct namespace by realm — never parsed
out of the id string.
- IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink: every node-naming method
gains `AddressSpaceRealm realm = AddressSpaceRealm.Uns` (transitional default so
un-migrated WP3 call sites still compile; WP3/Wave B makes them explicit and
removes the default). Null + SdkAddressSpaceSink impls updated; DeferredAddress-
SpaceSink forwards realm through every method (the forwarding trap).
- DeferredSinkForwardingReflectionTests: existing exhaustive-forwarding guard
auto-covers the new signatures; added an explicit guard that every node-naming
sink method carries an AddressSpaceRealm parameter (RebuildAddressSpace exempt).
- OtOpcUaNodeManager: register RawNamespaceUri + UnsNamespaceUri; realm->namespace
index via NamespaceIndexForRealm; all node maps (_variables/_folders/
_alarmConditions/_nativeAlarmNodeIds/_historizedTagnames/_eventNotifierSources)
re-keyed by the full ns-qualified NodeId string so Raw and UNS nodes sharing a
bare id stay distinct; _notifierFolders already NodeId-keyed. A historized UNS
reference node registers the SAME historian tagname as its backing raw node
(both NodeIds -> one tagname). Inbound-write hook routes the full ns-qualified
NodeId to the write gateway (realm-aware) and reverts by bare id + realm.
HistoryRead seams resolve via NodeId directly. DefaultNamespaceUri kept as a
transitional alias to UnsNamespaceUri for the SubscriptionSurvivalTests.
- Test doubles across Commons.Tests / OpcUaServer.Tests / Runtime.Tests updated to
the new interface signatures; SdkAddressSpaceSinkTests asserts the UNS namespace
index for default-realm nodes.
Build: dotnet build ZB.MOM.WW.OtOpcUa.slnx = 0 errors.
Tests: Commons.Tests 310/310; OpcUaServer.Tests 335 passed / 4 pre-existing skips.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
- ConfigComposer: snapshot v3 tables (RawFolders/TagGroups/UnsTagReferences),
drop the retired Namespaces snapshot; RevisionHash follows the new blob.
- DeploymentArtifact: compute each raw tag's RawPath (RawFolder->Driver->Device->
TagGroup ancestry via shared RawPathResolver); per-driver RawTags + merged
DriverConfig+DeviceConfig config injected into DriverInstanceSpec via
DriverDeviceConfigMerger; ParseComposition emits an empty EquipmentTags set
(DARK until Batch 4); EquipmentNode driver/device hooks always null; cluster
scoping attributes equipment by UNS line only.
- AddressSpaceComposer: rewritten to the v3 shape (no Namespace/NamespaceKind,
no dropped Tag/Equipment fields); emits empty EquipmentTags (parity mirror).
- DriverHostActor: fan-out/write map tuple member FullName -> RawPath.
- Commons: new RawPathResolver (shared identity authority) + DriverDeviceConfigMerger
(single/multi-device endpoint+RawTags merge).
- DraftValidator: v3 rules — raw-name charset (RawPaths.ValidateSegment),
historized effective-tagname <=255, UNS effective-leaf uniqueness across
UnsTagReference/VirtualTag/ScriptedAlarm; DraftSnapshot(+Factory) carry the new tables.
- AdminOperationsActor: tag-config inspection resolves driver via Device (no
EquipmentId/DriverInstanceId on Tag).
- Tests: RawPathResolver/merger unit tests (Commons.Tests, green) +
DeploymentArtifact RawPath/dark test (Runtime.Tests, awaits WP6 corpus fixes).
Deletes the composer's ExtractTagFullName/Alarm/Historize/Array statics and (co-located
to keep the build green, per plan T5) the three OpcUaServer.Tests ExtractTag* suites whose
tables now live in Commons.Tests/TagConfigIntentTests. T10 is the grep-sweep verification.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
PR #423 shipped GatewayTagProvisioner + unit tests but never registered it in
DI nor passed it into the AddressSpaceApplier, so deploying historized tags used
the no-op NullHistorianProvisioning and never called the gateway's EnsureTags
(confirmed live on wonder-app-vd03: zero EnsureTags calls on a historized deploy).
Addresses HISTORIAN-GATEWAY-INTEGRATION-ISSUES.md.
Issue 1 (wire provisioner):
- Runtime: AddHistorianProvisioning extension (gated on ServerHistorian:Enabled,
mirrors AddServerHistorian) + NullHistorianProvisioning TryAdd default in
AddOtOpcUaRuntime; WithOtOpcUaRuntimeActors resolves IHistorianProvisioning and
passes it into the applier.
- Gateway driver: GatewayHistorian.CreateProvisioner factory (mirrors CreateDataSource).
- Host: Program.cs calls AddHistorianProvisioning after AddServerHistorian.
- Tests: AddHistorianProvisioningTests (config-gated registration + the
register->resolve->applier->EnsureTags chain).
Issue 2 (observability): AddressSpaceApplier logs the provisioning tally on every
successful dispatch (was gated behind Failed/Skipped > 0), including dispatched=N
so a dispatched=N/requested=0 line flags the dormant no-op. +2 tests.
Issue 3 (30s HistoryRead on unprovisioned tags): root coupling fixed by Issue 1;
documented the CallTimeout knob + coupling. Default left at 30s pending the
multi-data-point investigation the issue requests (lowering risks truncating
legitimate large reads).
Issue 4 (docs): docs/Historian.md gains a "Tag auto-provisioning (EnsureTags)"
section and CLAUDE.md a wiring/gating note (both stress ServerHistorian:Enabled).
Sibling scadaproj/CLAUDE.md carries no false claim -> unchanged.
Pre-existing Serilog observation: anchor CWD to AppContext.BaseDirectory before
AddZbSerilog so the relative file sink stops landing in C:\Windows\System32 under
the Windows-service CWD.
Builds 0-error; Runtime.Tests 355, OpcUaServer.Tests 329, Gateway.Tests 99 (+4
live-skipped) all green.
The continuous-historization recorder conflated two identifiers into one string:
the dependency mux fans DependencyValueChanged keyed by the driver FullName
(the mux ref), but a value must be historized under the resolved historian name
(HistorianTagname override, else FullName). In the common no-override case the
two are equal, so it worked; with an override they diverge and the recorder
registered mux interest under a key the mux never fans — that tag's values were
never captured (and, had they been, would have been written under the mux ref).
Carry BOTH identifiers through the seam: a new HistorizedTagRef(MuxRef,
HistorianName) record on IHistorizedTagSubscriptionSink. The applier resolves
MuxRef = FullName and HistorianName = override-or-FullName. The recorder now
keeps a muxRef->historianName map: it registers/filters mux interest by MuxRef
but writes the outbox entry (and drains) under HistorianName. The convergence
handler re-registers the mux only when the registered key-set changes, so an
override-only rename (same FullName) updates the write target without mux churn.
Tests: a divergent-override recorder test (interest by mux ref, value written
under the override name, never the mux ref) + an override-rename no-churn test;
the applier feed tests now assert the full (mux ref, historian name) pairs.
Runtime 348/0, OpcUaServer 327/0; 0 warnings. Closes FU-3.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
The ContinuousHistorizationRecorder was spawned with an EMPTY historized-ref
set, so it registered interest in nothing and historized nothing. This feeds it
the currently-historized tag refs on every address-space deploy/redeploy so its
DependencyMuxActor interest converges to exactly the historized set (the same
refs the EnsureTags provisioning hook resolves: override-or-FullName).
Design — delta convergence (the plan is a pure DIFF):
- New seam IHistorizedTagSubscriptionSink (Core.Abstractions/Historian) with a
Null no-op singleton, mirroring how IHistorianProvisioning decouples the T15
hook. AddressSpaceApplier gains a DEFAULTED ctor param (Null sink) so all ~80
existing call sites + the production site compile unchanged.
- Apply() only ever sees a plan diff (an incremental/surgical apply carries a
delta, not the full set), so the applier feeds an add/remove DELTA computed
from AddedEquipmentTags / RemovedEquipmentTags / ChangedEquipmentTags. The
recorder keeps the full set and re-registers it. The feed is a single
non-blocking Tell behind the sink, wrapped in try/catch so a faulting feed
never blocks or breaks a deploy (same discipline as the provisioning hook).
- Recorder.UpdateHistorizedRefs(added, removed) converges the tracked set, then
— only when it actually changed — sends ONE RegisterInterest with the full set
(the mux's RegisterInterest is a full-REPLACE) or one UnregisterInterest when
it drains to empty (the mux has no per-ref unregister). An unchanged delta is
a no-op (no mux churn).
- DI: the recorder is now spawned BEFORE the applier so the adapter
(ActorHistorizedTagSubscriptionSink) can wrap its IActorRef; the Null sink is
used when continuous historization is off/unwired.
Tests: recorder convergence (add-from-empty, add+remove converge, idempotent,
drain-to-empty unregisters); applier feeds resolved added refs, removed+renamed
deltas, and survives a throwing sink. Build clean (0 warnings on touched
projects); Runtime/OpcUaServer/Gateway/AdminUI suites green.
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
HistorianGateway is now the sole historian backend (read + alarm SendEvent +
continuous WriteLiveValues). Document the final state and retire the Wonderware
sidecar from the docs/config/labels:
- CLAUDE.md: rewrite the Historian section — ServerHistorian /
ContinuousHistorization / AlarmHistorian config keys, the IHistorianProvisioning
EnsureTags hook, the GatewayAlarmHistorianWriter SendEvent path + ReadEvents
dependency on gateway RuntimeDb:EventReadsEnabled=true, gateway-side
prerequisites (RuntimeDb flags + historian:read/write/tags:write scopes),
migration note, and two KNOWN-LIMITATION callouts (live-validation gate +
empty historized-ref-set recorder follow-on).
- appsettings.json: fix the stale ServerHistorian block (Host/Port/SharedSecret/
ServerCertThumbprint -> Endpoint/ApiKey/UseTls/AllowUntrustedServerCertificate/
CaCertificatePath/CallTimeout, keep MaxTieClusterOverfetch); add a disabled
ContinuousHistorization block; prune the orphaned Wonderware keys from
AlarmHistorian (keep the SQLite knobs). ApiKey env-supplied via
ServerHistorian__ApiKey (commented; valid strict JSON via _comment keys).
- README.md + docs (Historian.md, AlarmHistorian.md, Configuration.md,
ServiceHosting.md, DriverLifecycle.md, drivers/README.md, Uns.md, VirtualTags.md,
AlarmTracking.md, Client.UI.md, README.md, TestConnectProbes.md): retire the
Wonderware historian backend from current-backend descriptions; fix the stale
ServerHistorian/AlarmHistorian config tables (now gateway shape); convert
drivers/Historian.Wonderware.md to a retired stub pointing at the gateway.
- Source/UI labels (descriptive text only, no behavior change):
OtOpcUaServerHostedService.cs, HistoryPaging.cs, OtOpcUaSdkServer.cs,
HistorianAdapterActor.cs, VirtualTagModal.razor, ScriptedAlarmModal.razor,
AlarmsHistorian.razor now name the HistorianGateway backend.
Build clean (0 errors); AdminUI.Tests green (514 passed).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
Addresses T15 review: treat a canceled EnsureTags task like a faulted one so the
fire-and-forget continuation never reaches t.Result (which would re-throw and leave
the discarded task unobserved).
Claude-Session: https://claude.ai/code/session_012SDSQ3AcaXqPcBtDESBRii
A rename-only deploy produced an IsEmpty plan that short-circuited before MaterialiseHierarchy,
leaving the OPC UA folder DisplayName stale. AddressSpacePlanner now diffs UnsAreas/UnsLines by
stable id into a RenamedFolders set (counted in IsEmpty); the applier refreshes the folder in
place via a new UpdateFolderDisplayName on ISurgicalAddressSpaceSink (forwarded through
DeferredAddressSpaceSink so it is NOT inert on driver hosts; falls back to rebuild when the sink
is non-surgical). DeploymentArtifact byte-parity untouched (rename rides the existing Name
round-trip). No EF migration, no serialized wire/proto contract change. +13 OpcUaServer tests, Runtime rebuild test.
- OpcUaServer-002: HistoryRead-Events NumValuesPerNode==0 now maps to unbounded (int.MaxValue) instead of the backend default-cap sentinel; no Core.Abstractions contract change (+EventMaxEvents helper tests)
- OpcUaServer-004: EnsureAddressSpaceCreated guard on public mutators -> clear InvalidOperationException instead of bare NRE if called pre-start (+tests)
- OpcUaServer-003: Deferred (endUtc inclusive/exclusive needs live Wonderware boundary confirmation)
- Configuration-013: wire DraftValidator.ValidateClusterTopology into AdminOperationsActor deploy gate (read-only, no migration) (+2 tests)
Cross-module fix from the review sweep. -007 (Medium): OnTimedUnshelve built its AlarmCommand
with User=string.Empty, so Part9StateMachine.ApplyUnshelve rejected it (ArgumentException,
swallowed) and a TimedShelve never auto-expired. Pass the canonical 'system' user; the
AlarmAck-gate bypass is preserved. Repurposed the test that had encoded the bug.
Live-verify finding: the surgical DataType/array path only fires for drivers whose
TagConfig carries a stable top-level FullName (Galaxy/OpcUaClient). For protocol
drivers (Modbus/S7/...), ExtractTagFullName falls back to the raw TagConfig blob, so
a shape edit also mutates FullName → safe full-rebuild fallback. Comment-only.
Code-review follow-ups on the FB-7 surgical shape-write commit:
- GeneralModelChangeEvent now sets SourceNode=Server + SourceName (Part 3 §8.7.4)
so clients filtering events by SourceNode match it (report still uses source:null).
- UpdateTagAttributes adds an explicit dataType null/empty guard (widened surface).
- Tighten the ArrayLengthDiffers doc comment.
- Add array→scalar transition test + null-arrayLength zero-default test (coverage
symmetry). 275/275 OpcUaServer.Tests green.