Joseph Doherty 4a3d7a9361 feat(modbus): wire Family / MelsecSubFamily / DisableFC23, and the form's timing keys
U1: a tag's addressString (Modicon / mnemonic / DL205 V-memory / MELSEC
D-X-Y grammar) now resolves through ModbusAddressParser with the DRIVER's
Family and MelsecSubFamily at every initialize and is authoritative; the
family-unaware gates (deploy Inspect, AdminUI parse consult) accept what
some family resolves. The tag editor gets an address-text field that
resolves with the owning driver's family and persists both the string and
the resolved region/offset/type fields; a hand edit drops the string.
DisableFC23 now gates FC23: by default a 2..121-register holding write is
one FC23 write + read-back (a unit answering exception 01, or failing FC23 at
the transport, moves to FC16 for the rest of the generation); RTU framing
deframes the FC23 reply. Live-checked: the pymodbus fixture implements FC23.
Also: the AdminUI driver form serialises ModbusDriverOptions (TimeSpan
strings), which the factory DTO never read - every timing field on the form
was dead. The DTO now accepts both shapes (*Ms keys win).

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:35:58 -04:00
Joseph Doherty ee12568cab refactor(modbus-rtu): distinct CrcMismatch/UnitMismatch desync reasons
v2-ci / build (pull_request) Successful in 4m1s
v2-ci / unit-tests (pull_request) Failing after 13m33s
The RTU framer overloaded DesyncReason.TruncatedFrame for three distinct
failures — a genuine short read, a CRC-16 validation failure, and a
CRC-valid reply from the wrong RS-485 slave. Split the latter two into
dedicated CrcMismatch / UnitMismatch enum members so a future .Reason
consumer (metrics, operator diagnostics) can tell a wiring/EMI CRC fault
apart from a mis-addressed multi-drop reply. Behaviour is unchanged — all
three still throw ModbusTransportDesyncException and tear the socket down.

Framing tests now assert the specific Reason on each path.

Follow-up #12 from the Modbus RTU-over-TCP plan.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-25 15:13:48 -04:00
Joseph Doherty 20100c36ad feat(modbus-rtu): validate response unit + cover partial-read/truncation in ModbusRtuFraming
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:42:25 -04:00
Joseph Doherty eed6617784 feat(modbus-rtu): add ModbusRtuFraming (ADU build + FC-aware length-less deframe)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:33:59 -04:00