A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
- Reserve an in-flight slot per client before authenticating (TryBegin /
Complete / Abandon under one lock); refuse once recorded failures +
in-flight attempts reach MaxFailedAttempts, so a parallel burst cannot
pass the check before its first failure is recorded.
- An expired lockout resets the count (LockoutSeconds < FailureWindowSeconds
relocked on every single failure after the first lockout).
- Validate OpcUa:CredentialLockout at host start: disabled, or both
durations > 0.
- Log the first refusal of a lockout episode at Information, the rest at
Debug.
- Document that on None endpoints the key is effectively IP-only (NAT
neighbours share a UserName count) and a null peer shares one key.
1. Orphaned subscriptions (session closed without deleting subs) have Session == null, so the public
MonitoredNode2.InvalidatePermissionCacheForSession never reached their items: a cached allow survived a
deploy, the moved alarm's events were queued and delivered on TransferSubscriptions. Each notifier's
cache is now cleared whole through the SDK's private MonitoredNode2.InvalidatePermissionCaches
(reflection, guard-tested; fallback = per-session drop + Remove/Add of session-less items).
2. The verdict is decided on the condition LIVE under the event's NodeId, not the event's own instance:
the SDK key has no instance identity, so a replaced instance's late event cached a deny its successor
inherited until the next invalidation.
3. Invalidation is skipped while enforcement is off (forced across an on/off authorizer transition) and is
one O(cache) clear per node instead of a whole-cache scan per item.
4. TagReferencingEquipment carries alarm-bearing raw tags only (TagConfigIntent.Alarm); the snapshot adopts
an OrdinalIgnoreCase set instead of copying it again.
Tests (each fails with its fix reverted): FolderEventVerdictInvalidationTests (orphan + deploy + transfer;
replaced instance's late event; ACL-off skip; SDK private-method guard), DeploymentArtifactScopePathTests
(alarm-bearing projection).
Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.
- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
as reference variables (an Area named like its equipment's id no longer narrows them).
Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
OPC Foundation SDK 2.0.1's SessionManager lockout refused EVERY
activation (Anonymous included, before the token is read) from a client
with 5 failed identity validations in 60 s, for 5 minutes, keyed on cert
thumbprint else peer IP. Disable it (MaxFailedAuthenticationAttempts=0
on built and loaded configs) and enforce FailedCredentialLockout in the
identity-registry adapter instead: UserName activations only, keyed on
thumbprint+peer together, same 5/60s/300s defaults, configurable via
OpcUa:CredentialLockout.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
Review r0 of Integration-W3:
- I1: the effective FC16 cap is min(configured maxRegistersPerWrite, 123). The
driver trusts a larger configured cap and sends an over-ceiling FC16 (past 127
registers its byte-count byte wraps), which every conformant device refuses, so
such an array is never advertised writable.
- I2: a BitInRegister[] write reads its span first in one unchunked FC03, so it is
also bounded by min(configured maxRegistersPerRead, 125) (absent/0 = 125).
- m2: every span (registers and coils) must end at or before address 65535.
- m1: the String-node wording says it converts only when the text parses, which
the server cannot promise (DateTime never converts).
- m4: the parity device now enforces FC01/02 2000, FC03/04 125 (or a smaller
device read limit), FC15 1968, FC16 123, FC23 121/125, the FC15/FC16 byte-count
field (exception 03) and the address-space end (exception 02).
Tests: parity rows for each ceiling/cap/span boundary against the real write
path, and Core.Abstractions row tests. The configured-cap test that asserted a
cap of 200 lifts the ceiling now asserts the opposite.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The Modbus lane (#741 U3) gave the driver String[] and BitInRegister[] holding-register array encoders, and
moved address resolution to ModbusTagAddressResolution (keys first, a bit region coerced to Bool, strict key
reads), but DriverArrayWriteSupport still listed both array shapes read-only (follow-up F1), so a client
write was BadNotWritable before it reached the driver.
Modbus row now mirrors the driver end to end:
- Keys shape only (region + address both present). A string-only addressString tag is resolved by the
driver with its own family through a parser Core.Abstractions cannot reference, so it stays read-only
(pinned: the conservative direction).
- Strict reads as the resolver: address an integer 0-65535; a present region / dataType / byteOrder /
stringByteOrder string must name a member.
- Coils: any dataType (coerced to Bool), <= 1968 coils (FC15).
- HoldingRegisters (FC16, never Bool): numeric, String ((stringLength+1)/2 registers, stringLength >= 1),
BitInRegister (1 register, bitIndex 0-15, span ending <= 65535), all within maxRegistersPerWrite.
FC23 is opt-in and never changes the answer.
- Elements convert (ScadaBridge int[] -> Int16 stays writable); only a String / DateTime node over a
numeric or bit element is left out, since such an element never converts.
Tests: the parity test's PendingF1 exemption and its guard are gone; the parity matrix is now region x
element type x node type against the real WriteAsync with a spec-conformant device (FC15 > 1968 refused),
plus shape edges at every cap boundary (numeric, String, BitInRegister, coil), strict key reads, FC23
on/off, string-only, the ScadaBridge int[] shape and U3 wire bytes. Core.Abstractions row tests and a
composer test (String[] and BitInRegister[] writable; over-cap, no-stringLength and string-only read-only).
Docs: table XML doc, Uns.md, modbus-addressing.md, drivers/Modbus.md, data-plane rules.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The Wave-2 lanes gave AbCip, AbLegacy and TwinCAT real whole-array write
encoders (review 07 U10/U9), but the capability table still listed all three
as scalar-only, so every array node materialised read-only and a client write
was BadNotWritable before it reached the driver.
Rows added, each listing only what WriteAsync encodes end to end:
- AbCip: SInt/USInt/Int/UInt/DInt/UDInt/Real/Dt/LInt/ULInt/LReal, declared
length, not a safetyTag. BOOL/STRING/Structure arrays stay read-only.
- AbLegacy: Int/AnalogInt on N/B/A, Long on L, Float on F (file-width match),
plain <file><n>:<word> address, <= 256 elements; not /bit, .sub, indirect,
S:/I:/O:, nor native PLC-5.
- TwinCAT: every codec element type, declared length; not a BOOL bit-in-word
path.
Elements convert in all three encoders, so the rows never key on an exact
node DataType (ScadaBridge int[] -> Int16 stays writable); they leave out
only node types whose elements never convert (DateTime/String over numeric,
Boolean on AbLegacy, STRING under DateTime on TwinCAT: culture-dependent).
Tests: driver-level parity for each driver (every element type x node type
plus shape cases, against the real write path), the AbLegacy parity tests
un-skipped, Core.Abstractions row tests, a composer test (three drivers
writable, refused shapes read-only), and the existing AbCip negative cases
moved to a BOOL array. Docs: Uns.md table, per-driver docs, data-plane rules.
Refs #737#738#739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Keeps the root CLAUDE.md lean by lazy-loading per-area detail (drivers, topology,
data-plane auth, alarms, historian) only when matching files are touched.