fix(ab): Task 22 review r1 — release-note timing and AbLegacy regressions, probe E2E on both transports
- I1: the upgrade restart itself moves every no-key AbCip/AbLegacy driver to Native (every process start constructs drivers, incl. boot-from-cache). Docs + CLAUDE.md now say so and tell operators to set "transport": "Libplctag" BEFORE upgrading (older builds ignore the unknown key). - I2: AbLegacy release note leads with the status-bit write refusal (T4:0.DN, C5:0.CU, R6:0.EN, ...) on defaulted SLC/MicroLogix drivers and the fallback. The real client status is BadCommunicationError, not BadNotSupported (the driver's write catch-all maps the runtime's AbTransportException like any transport failure, as #571 does for PLC-5), with handle eviction and Degraded health; pinned by a driver-level test (no 0xAA write on the wire, with a positive control). ST string byte order stated as unverified. Also corrects the docs' "T4:0/DN" examples: the driver's address grammar is "T4:0.DN" ("/DN" is a malformed address). - I3: DriverProbeHandshakeE2eTests' two AbCip probe tests are a [Theory] over Native and Libplctag. Run against ab_server controllogix: all 4 rows pass with identical exact messages. - M1: documented (docs + resolver XML doc): the AdminUI merges only the probed device, so a mixed-family defaulted AbLegacy driver can probe Native while running Libplctag. - M2: factory ParseEnum rejects undefined integer strings ("7") via Enum.IsDefined (both drivers). - M3: AbCip driver-level bad value reads "AB CIP config in '<id>' has unknown Transport ..."; the named constant is gone (tagName: null now means driver-level). - M4: the explicit-Native limited-family Warning is once per instance, not per (re)init. - Nit: EffectiveTransport docs note that injected factories bypass it. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe |
||
|
|
ed0881d672 |
feat(ab): native managed transport is the default for AbCip and AbLegacy; libplctag remains as fallback
Task 22 (spec section 8 P5), with the controller rulings that exclude PLC-5 and LogixPccc. - Transport is nullable on both option records; null (key absent) means "use the default" and is never serialized. Factory DTO parse: absent -> null; a bad value still fails via ParseEnum. - One resolver per driver (AbCipTransportResolver / AbLegacyTransportResolver), used by the driver constructor, the Test Connect probe and (through the driver) the CLI. AbCip: null -> Native. AbLegacy: null -> Native unless any device is Plc5 or LogixPccc, then the whole driver resolves to Libplctag. Explicit values always win; explicit Native with a Plc5/LogixPccc device logs one Warning at init. - Init log shows configured vs effective, e.g. transport=Native (default). - AdminUI forms: "Default (...)" / "Native (managed)" / "libplctag (fallback)". Default omits the key on save (reverses Task 19's explicit re-emit, which would have pinned every edited driver). - CLIs: --transport default|native|libplctag, default "default" via the resolver, so --plc-type Plc5 with no --transport runs libplctag. - Tests pinned to Libplctag where a default-path runtime was created: found by instrumenting the native factories with the current xUnit test name (one unit test, AbLegacyReinitConfigAdoption; plus the two fixture-gated AbCip probe E2E tests whose exact messages were proven on libplctag). TransportMatrix and the differential harness already pass explicit transports. - Switch/resolver/CLI/form tests are falsified by mutating the resolver (default -> Libplctag, exclusion removed, AbLegacy default -> Libplctag): each mutation turns them red. - Replaces the inline role-name literal in AbCipDriverFactoryExtensions' ParseEnum call with a named constant; RoleAuthorityGuardTests was already red on the base commit for that line. - Docs: AbCip.md / AbLegacy.md default + release note; CLAUDE.md AB section. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe |
||
|
|
6b3da93151 |
fix(browse): commit the browsed data type, and fix the probe classification the fixture was hiding (#536)
A browse-committed AB CIP / TwinCAT / FOCAS tag bound with its model's DEFAULT
data type, not the one the device reported. A browsed REAL committed as
`{"tagPath":"Pump_1_Speed","dataType":"DInt"}` — and those three drivers decode
the wire bytes by that field, not by the raw row's OPC UA DataType — so the tag
read four bytes of a float through an integer decoder and published a plausible
wrong number with no error raised anywhere. FOCAS was missed when #536 was filed.
The type is CARRIED, not derived. Reverse-mapping the leaf's driver-agnostic
DriverDataType looks like the smaller fix and is wrong: SInt/Int/DInt/USInt/UInt
all collapse into Int32 on the way out of the driver, so that version would bind
a 16-bit INT as a 32-bit DINT while appearing to fix the REAL. Drivers now state
their own type name on DriverAttributeInfo.NativeDataType, which reaches the
picker as AttributeInfo.AddressFields["dataType"] and the commit mapper from
there. A leaf that states nothing keeps the model default — the pre-#536
behaviour, kept deliberately as the fallback rather than a guess.
Numeric strings are refused before parsing: Enum.TryParse accepts "9" for any
enum and Enum.IsDefined then confirms it, so an unguarded parse would bind a tag
to a type nobody named. A test caught this in the first version of the guard.
--- and the other half, which the fixture was hiding ---
Test Connect on a device with NO authored tags — every AB CIP device at the
moment an operator first presses the button — reported "CIP handshake failed"
against a healthy controller. That was written down as a fixture limitation
("ab_server doesn't implement @raw_cpu_type"). Both halves of that were wrong:
* @raw_cpu_type is not a libplctag special tag at all (only @raw, @tags and
@udt/ are), so it goes out as an ordinary symbolic name that no controller
defines, and the controller's "tag does not exist" IS the successful answer.
* ab_server answered an unresolvable tag path with CIP 0x03 where a Logix
controller answers 0x04 — ErrorBadParam vs ErrorNotFound, which the probe
classifies oppositely. Fixed in vendored patch 0002.
* With the fixture then telling the truth, the real defect surfaced:
AbCipDriverProbe.IsReachableException matched the native C status spellings
("STATUS_NOT_FOUND"), but libplctag.NET throws with the MANAGED enum name
("ErrorNotFound"). Those substrings can never match, so the reachable
classification could not fire on the exception path — which is the path every
no-authored-tags probe takes. This was failing on real hardware too, not just
against the sim. It now recovers the Status and defers to IsReachableStatus,
so there is one classification rather than two that can drift.
Rejected: switching the fallback to @tags. libplctag builds a tag-listing tag
with NO network I/O, so it reports OK against any TCP listener — measured green
against a Mosquitto broker.
Verification: full solution suite green. Falsification runs confirm exactly the
intended tests go red — 9 for the type carry, 3 (the reachable statuses only) for
the probe classification. Live on docker-dev: browse-committed TestString/
Motor_Run/TestSINT now store String/Bool/SInt, alongside last session's
Pump_1_Speed still holding the wrong DInt. TestSINT is the falsifier — its row
DataType is Int32, identical to TestDINT's, so no reverse map could have produced
"SInt".
Known consequence: pre-existing browse-committed tags keep their wrong dataType;
the fix applies to new commits only.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
|
||
|
|
df340b8bba |
fix(tests): three real failures the integration suite had stopped catching
None of these were fixture absence. Each is a guard that went quietly wrong and then reported the wrong thing. PrimaryGateFailoverTests — per-cluster mesh Phase 6 ( |
||
|
|
4b14feb373 |
fix(drivers): serialize driver-config enums as strings in AdminUI pages + probes
AdminUI driver-instance pages serialized enum config fields (S7 CpuType, Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories, however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw when binding a JSON number to a string? — so an AdminUI-authored config containing any enum field produced a blob the driver could not parse, faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe (its factory + probe already carried the converter). Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the 8 missing driver probes' _opts (factories unchanged — already string-via- ParseEnum; strictly more permissive, also lets pages load hand-seeded string-enum configs back into the form). Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound, which the probe treats as reachable; hardware-gated follow-up). Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests); factory round-trip + numeric-form-throws guards for S7 and Modbus. Found by running the never-before-run FB-9/FB-10 live verifies. |
||
|
|
1164d423b6 |
fix(probe): Galaxy gRPC ping — drop invalid Retry, treat MxGatewayAuth exceptions as reachable (live /run)
v2-ci / build (push) Failing after 44s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Two bugs caught by live verification against the mxaccessgw at 10.100.0.48:5120: - MaxAttempts=1 produced an invalid Polly RetryStrategyOptions -> the probe failed on every real gateway. Removed the Retry override (matches GalaxyDriver); fail-fast is already guaranteed by the TCP preflight + the per-call deadline. - A rejected key surfaces as a typed MxGatewayAuthenticationException, not a raw RpcException, so 'auth-rejection = reachable' was bypassed. Catch the typed auth/ authorization exceptions -> Ok=true. Adds DriverProbeHandshakeE2eTests: direct-probe, skip-gated cross-protocol green/red discrimination (Modbus, OpcUaClient, Galaxy + a local real OPC UA server). |