Commit Graph

5 Commits

Author SHA1 Message Date
Joseph Doherty 3edff3304b fix(ab-transport): per-pool diagnostics + per-device open-attempt limit, CIP-level close recycle, CipConnection/pool test gaps (#566, #581)
- Process-wide CipConnection statics (ForwardOpenCount, Forward Close counts, RequestsSent, exchange
  stats, OpenAttempts, OpenAttemptBudget) move to an instance ConnectionDiagnostics owned by each
  DeviceSessionPool (and by a stand-alone CipConnection). The open-attempt budget becomes a disposable
  per-DeviceKey limit (LimitOpenAttempts); the differential harness scopes one to the press under test.
- LibplctagOrphanRelease.ForceRootingForTest is gone: ReleaseIfOrphaned(tag, canReadHandles) overload.
- A connected reply with general 0x01 / extended 0x0107 or 0x0203 (target no longer holds the class-3
  connection, TCP still up) retires the session at once; the next send reopens through the throttle.
- New tests: dispose during RegisterSession, abandoned-open observer (falsified), scheduler-dispose-throws
  guard (DeviceSessionPool.CloseAsync), release-in-background with a shared open in flight, per-device
  limit scoping, CIP-close recycle (request + keep-alive + negative control).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 23:21:02 -04:00
Joseph Doherty 4e6eed7454 fix(abcip): native runtime STRING capacity, mistype churn, malformed-name config error, LWORD type check; non-blocking lease release (#570, #579)
#570
- STRING: the built-in 88-byte Logix STRING holds 82 characters (LEN + DATA[82] + 2 pad), not 84; the
  write still sends the whole 88-byte structure and a read never decodes the pad as characters.
- Mistype churn: a type refusal (CIP 0xFF/0x2107) on the existence read no longer throws from
  InitializeAsync, so the runtime is not disposed/re-created (and re-Forward-Opened) every poll; the driver
  also keeps a runtime that throws TypeMismatch from init and records the device as reachable.
- Malformed tag name: a TagPath that does not parse, or a name the CIP symbolic encoder refuses (now also
  non-ASCII, empty member, >255-char member, unterminated subscript), is AbCipTagConfigurationException ->
  per-tag BadConfigurationError (named const in AbCipStatusMapper), warned once, never feeding the device
  backoff or health; siblings keep reading. A malformed probe tag no longer feeds the backoff either.
- Micro800 BYTE/WORD/LWORD (0xD1/0xD2/0xD4) are type-checked as integers of their width: REAL/LREAL or a
  narrower integer over LWORD is TypeMismatch, not decoded garbage.

#579
- ConnectionLease.ReleaseInBackground: one non-blocking release shape for both native AB runtimes. The
  AbCip runtime's Dispose no longer waits up to 2 s under the per-tag lock; the pool still registers the
  close synchronously so a re-create cannot overlap it. Offline soak tests (25 cycles, AbCip + AbLegacy)
  prove no leaked connection; FakeEipServer gains OpenConnections.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 23:05:49 -04:00
Joseph Doherty 33dbd342e5 fix(ab-transport): trim-only CIP path canonicalisation, observe abandoned shared opens, no Forward Open after dispose during connect 2026-10-07 16:49:19 -04:00
Joseph Doherty a251954bf7 fix(ab-transport): harden Task 9 pool and connection (close chaining, uncancellable shared open, monotonic throttle, canonical CIP path, internal ctors, shared-pool logger) 2026-10-07 16:45:26 -04:00
Joseph Doherty b82fffd269 feat(ab-transport): per-device connection with routing modes, shared scheduler, keep-alive and Forward Open throttle 2026-10-07 16:35:11 -04:00