#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.
Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.
#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
The Test-Connect probe set is resolved inside the AdminOperations Akka starter; resolving
ISecretResolver there walks AddZbSecrets -> IAuditWriter -> ActorAuditWriter, whose ctor needs
AuditWriterActorKey (registered later in the same builder). Found by the docker-dev live gate.
Regression test: resolving the probe set never resolves ISecretResolver (fails before the fix).
Also: TagRowProblem doc comment re-attached; Heidenhain credential help text names the
secret:heidenhain/ and env:OTOPCUA_HEIDENHAIN_ namespaces.
- Review 1: RawTreeService Create/UpdateDriver and Create/UpdateDevice refuse a Heidenhain
config whose password fields are not blank / secret:heidenhain/... / env:OTOPCUA_HEIDENHAIN_...
(DriverConfigSaveGate over HeidenhainOptionsParser.DescribeCredentialProblems: top level,
Access, Devices[], case-insensitive keys; the value is never echoed), so a literal password
never reaches the draft DB. The driver and device modals show the reason and disable Save.
- Review 8: CreateTag/UpdateTag/ImportTags (tag modal, manual entry, CSV import, browse commit)
refuse a ReadWrite Heidenhain tag or a Tag.DataType that disagrees with what the driver
publishes (HeidenhainTagRules: catalog type, Float64 => Double, or the binding's dataType).
The tag modal and manual-entry grid fix the access level at Read and derive the data type from
the address (RawTagRowDefaults). New deploy gate HeidenhainTagDataTypeMismatch.
- docs/drivers/Heidenhain.md: credential namespace convention + why, the save-path and deploy
enforcement, optional-role credential behaviour, BadConfigurationError, backoff/ordering notes.
Tests: HeidenhainSavePathTests (service save path; red with the gates disabled) and new
DraftValidatorHeidenhainTests cases.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
Real Heidenhain driver (factory-built from a merged config) against the in-process LSV2
simulator inside DriverInstanceActor: subscribe publishes Good, an OPC write is refused by
the runtime (no IWritable) with nothing sent to the control, an outage stamps
BadNoCommunication, recovery re-publishes the identical value Good, and only allowlisted
telegrams ever reach the simulated control.
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
A wrong published value now reports its Success/Value/Reason/StatusCode, the
publish's wall time against the run budget, the run guard's in-flight /
refused / quarantined counters, thread-pool and GC state around the call,
the shadow stats, and the tails of the script and runner logs.
Reproduced under heavy load (32 `yes`, test at nice 20, load avg 300+):
3 of 8 runs failed, every one because the SIBLING's shadow run missed the
300 ms soft deadline in the starved worker ("shadow Failed [budget] script
timed out after 0.3s") and was rightly recorded as a sibling mismatch. No
published value was ever wrong. The out-of-process soft deadline is armed at
submit, so it covers the pipe round trip and worker scheduling too.
The run budget (which is also the worker's soft deadline) goes to the 2 s
production default; no assertion changes. The runaway still runs away and is
killed at T + HardGrace, so nothing the test proves depends on T being short.
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).
The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.
Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
ShadowModeTests' runaway case asserted "slowest < 250 ms" around evaluations
whose timing included cold Roslyn compile/JIT of new script text, so it failed
on a healthy published path (540-880 ms measured, both SDK baselines).
The test now puts a test-owned barrier runner (GatedShadow) between the real
ShadowScriptRunner and the real worker pool. The runaway's first shadow run is
held before it reaches the pool, then (after it runs away in the worker, the
pool answers T and the worker is KilledDeadline with the runaway as culprit)
its outcome is held before comparison. Published evaluations made while a
barrier is closed must return the in-process values; a Mirror that waited for
its shadow hangs into a 30 s liveness failure (mutation-checked). Output
correctness, pool kill/quarantine, published-side never quarantined, the single
runaway mismatch (sibling is a victim, not compared) and key_busy drops are kept.
The wall-clock number moves to an opt-in Category=Perf case
(Shadow_published_path_latency_while_the_shadow_runs_away, OTOPCUA_SCRIPT_PERF=1)
on warmed evaluators, reporting hardware and load average.
Sibling: ContainmentTests' hard-deadline case timed the runaway's first
(cold-compile) run; it now compiles the runaway's source first with an input
that does not spin.
Central pin 1.1.0 -> 3.2.2; AdminUI/ControlPlane/Runtime/Host.Tests no longer carry VersionOverride.
The three driver IntegrationTests fixtures' Fact/Theory attributes gain the source-info ctor (xUnit3003).
No xUnit1051 fallout remained (already cleaned). Test counts unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Akka.TestKit.Xunit2 -> Akka.TestKit.Xunit 1.5.62 (xunit.v3 TestKit; needs xunit.v3 3.2.2, set via
VersionOverride on the four projects). Removes the xunit 2.9.3 pin. IAsyncLifetime returns ValueTask,
SqlServerFactAttribute gains the source-info ctor, and xUnit1051 call sites pass
TestContext.Current.CancellationToken. Test counts unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Owner decisions §14 #5/#6 as built (design §12.5):
- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
the host's window station and desktop, because USER32 init made coreclr.dll fail with
ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
the pipe ACL, token access and a real restricted worker running a script, all green on windev.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
ForbiddenTypeAnalyzer now denies System.AppContext, System.Console, GCSettings, ProfileOptimization,
EncodingProvider/CodePagesEncodingProvider, TypeDescriptor and CryptoConfig as types, and the ambient
CultureInfo.{DefaultThreadCurrentCulture,DefaultThreadCurrentUICulture,CurrentCulture,CurrentUICulture}
and TimeZoneInfo.ClearCachedData members (member deny-list now covers properties and member-access reads).
Shadow-mode tests diverge via culture-sensitive string.Compare (worker is InvariantGlobalization) instead of
AppContext.BaseDirectory, with a premise test. Mutation-proved: 21 new cases fail with the analyzer reverted.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV