8971861b7c56a2b1ac347f4fa80bd4883dbb3b76
358 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
8971861b7c |
fix(adminui): MTConnect editor must read driverDataType at the runtime's precedence and drop the alias on save (#550)
MTConnectTagDefinitionFactory.TryFromTagConfig resolves the coercion type as
FirstNonBlank(blob.DriverDataType, blob.DataType) — driverDataType OUT-RANKS
dataType — while MTConnectTagConfigModel read and wrote dataType alone. That
broke in both directions at once:
* a blob carrying "driverDataType": "Strng" was accepted at authoring while
the runtime rejected the tag (the residual slice of #549), and
* a VALID driverDataType silently overrode whatever type the editor displayed
and saved, so the editor showed a lie and a save RETYPED the tag.
Both halves land together, mirroring the existing IdKeys pattern:
* FromJson reads DataTypeKeys = [driverDataType, dataType] in the runtime's
precedence, with the runtime's own per-key semantics — absent/JSON-null and
present-but-blank fall through, a non-string token stops the walk (the
runtime deserialise throws JsonException on it and rejects the whole tag),
and the raw TOKEN is captured so Validate() judges what the driver judges.
* ToJson drops every non-canonical DataTypeKeys entry and writes dataType as
the enum NAME, so the alias can never out-rank the key the editor writes on
the next load.
* Validate() now names the offending spelling rather than always saying
"dataType".
Doing only one half silently retypes existing tags on their next save; the
falsification runs recorded in the PR confirm each half-fix reddens a distinct
test.
|
||
|
|
a3c0ec037f |
fix(adminui): authoring must not accept a TagConfig enum the runtime rejects (#549)
MTConnectTagConfigModel read `dataType` with TagConfigJson.GetEnum, which falls
back to String on ANY unrecognised value. A misspelled name ("Strng") from a
hand-authored blob, a CSV import or the API was therefore accepted at authoring
and silently rewritten, while the driver's strict parse rejected it and the tag
died with BadNodeIdUnknown. Found by the G-7 parity tests' falsifiability
control, which had to use the digits-only shape to have a case that failed.
The rule is not restated in the AdminUI. MTConnectTagDefinitionFactory exposes
its parse as `IsAcceptedDataTypeName`, documented as the one authority the
driver, the deploy gate and the authoring model all consult; the model's
Validate() asks it about the raw value the blob carries. The old digits-only
message is NOT retained as a special case: the runtime draws no distinction
between a bare number and a typo — one predicate, one Inspect warning — so a
second message here would be a second statement of a rule this model does not
own. The raw value is captured as the JSON TOKEN, because the runtime
deserialises the key into a `string?` DTO field and an unquoted number throws
there too.
The survey found the same asymmetry at six more editors, contrary to the
assumption that those runtimes silently default: R2-11 Phase C moved every
driver's TagConfig enum read to TagConfigJson.TryReadEnumStrict, which REJECTS
the tag on a present-but-invalid string, while the editors kept loading them
with a silent fallback. Modbus (region/dataType/byteOrder), S7, AbCip, AbLegacy,
TwinCAT and FOCAS now check their enums in Validate() through the runtime's own
TagConfigJson.DescribeInvalidEnumText — added alongside a public
ClassifyEnumText that TryReadEnum now delegates to, so the JSON-token door and
the string door reach one implementation. Mqtt and Sql already carried
equivalent strict checks and are untouched.
Care taken NOT to become stricter than the runtime: a present-but-non-string
token stays accepted for those six (TryReadEnum calls it absent), as does an
absent key, each pinned by a test.
Also adds a direct ProjectReference to Core.Abstractions from the AdminUI — the
save gate now leans on a type it was consuming only transitively.
|
||
|
|
0739f4b9a4 | merge: RawBrowseModal post-await staleness guard (deferment §0.1 race ported from the 2026-08-05 sibling fix) | ||
|
|
87637e4e2c |
fix(adminui): guard RawBrowseModal's resolve against a superseded open
Blazor does not serialize OnParametersSetAsync against its own outstanding task, and the modal's `_open` bool cannot tell two opens apart. ResetAndResolveAsync awaits LoadMergedProbeConfigAsync and ResolveGroupContextAsync and then wrote _driverType/_mergedConfig/_effectiveDeviceId/_groupPrefix/_canBrowse/_disabledReason with no staleness re-check, so a close-reopen onto another device let the first open's late continuation install its device's browse context under the displayed modal — "Connect & browse" would silently dial the wrong controller and the commit would land under the wrong tag-group. Ports the per-open `_openGeneration` counter proven in the two sibling modals (RawManualTagEntryModal, RawTagModal, 2026-08-05) to every post-await write here: after both awaits, in the catch's error banner, and in the finally. The finally is the one departure from the sibling shape and it is load-bearing — this modal resolves inside a try/finally, so a stale `return` still runs the tail and would drop the LIVE open's spinner mid-resolve. Pinned by four RawBrowseModalStaleOpenTests facts, each observed red before the guard and each re-falsified afterwards by reverting only its own guard. The modal calls StateHasChanged on the open path, which throws without a render handle, so the test attaches an inert Renderer subclass (file-local BL0006 pragma); [Parameter]s are set by reflection per the BL0005 convention. AdminUI suite 1117/1117 green. |
||
|
|
dac7e1885d |
feat(resilience): route IDriver.InitializeAsync through the capability invoker (R2-10 T10 closed)
The connect path was the one capability call the resilience pipeline never saw, so a driver that could not connect contributed zero breaker input and the /hosts resilience panel read 'All targets healthy' against a dead endpoint. InitializeAsync now routes through the invoker as DriverCapability.Initialize, keyed on the driver-instance id. - No pipeline retry: the actor's RetryConnect timer is the retry loop (parser forces retryCount overrides to 0, same funnel as write-shaped). - Breaker threshold 2, not the Read-sized 5: the breaker samples 30 s and the reconnect timer fires every 10 s, so at most three attempts fit one window — threshold 5 could never open. Pinned by its own test. - An open breaker fast-fails into the same InitializeFailed path as a real connect failure; the 15 s break window costs at most one extra tick. The best-effort teardown ShutdownAsync stays unwrapped. - Companion fix: DriverCapabilityInvokerFactory.Create now invalidates the instance's tracker snapshots with its pipelines — a respawn during an outage discarded the only breaker whose OnClosed could clear the OPEN flag, stranding a false 'Breaker OPEN' chip forever. Live gate PASSED on docker-dev (image symbol-verified per container): rtu-gate against dead 10.100.0.35:5021 opened its Initialize breaker on both centrals with the red 'BREAKER OPEN' chip on /hosts; a socat 5021→5020 forwarder recovered it (both breakers closed within 1 s, panel back to 'All targets healthy'); healthy MAIN-modbus recorded zero breaker events. Full suite 50/50 green. Evidence: docs/plans/2026-08-07-adminui-followups-and-live-gates.md §7. |
||
|
|
9420f8efff |
Merge fix/issue-546-panel: wire DriverStatusPanel into /hosts driver rows (#546)
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1 |
||
|
|
e669fb349a |
fix(adminui): #546 recycle DriverStatusPanel on Enabled flip via @key
DriverStatusPanel decides whether to subscribe exactly once, in OnInitializedAsync (`if (!Enabled) return;`), and exposes no OnParametersSet hook. The detail row was keyed only by DriverInstanceId, so a live config edit that flipped a row's Enabled true->false — surfaced on the page by the 5 s LoadConfigAsync refresh — reused the same panel instance: the markup correctly switched to "Disabled - not deployed" while the panel's two store SnapshotChanged subscriptions and its 5 s staleness timer stayed wired underneath, until the operator happened to collapse the row. Including the flag in the detail row's key recycles the component instead. Both directions verified against the panel's own lifecycle: true->false disposes the old instance (unsubscribing both stores, draining both timers) and mounts one that skips subscription setup entirely; false->true disposes an instance that never subscribed (the unsubscribes are no-ops, both timers null) and mounts one that subscribes and primes from the stores. The data row's key is unchanged. No behaviour change when Enabled is stable. Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1 |
||
|
|
f1c188114b |
refactor(fleet): #542 delete the dead fleet-status chain (broadcaster, SignalR bridge, hub, messages)
#542 filed FleetStatusBroadcaster as blind to site nodes since the Phase 6 per-cluster mesh split: it derives "the fleet" from central's own Akka gossip ring, which after the split is just central's own pair. Scoping the cross-mesh rewrite found the deeper truth — the whole chain is dead end to end, so this deletes it rather than reviving it. - Zero consumers. FleetStatusBroadcaster published FleetStatusChanged on the DPS "fleet-status" topic; FleetStatusSignalRBridge forwarded it to FleetStatusHub ("/hubs/fleet-status"); nothing anywhere connected. The AdminUI bans self-connecting HubConnections, no browser JS subscribes, and /fleet (Fleet.razor) reads NodeDeploymentState from the ConfigDb plus IClusterRoleInfo on a 5 s poll instead. - Its second input never existed. DriverHostStatusHeartbeat had no production sender — only the broadcaster's own test told it — so CurrentRevision was always null and the 30 s staleness -> Degraded flip could never fire. - Post-Phase-6 DPS is pair-local, so even the central-only view it did produce was an accident of topology rather than a design. The fleet visibility that actually works is unchanged and already cross-mesh-correct: /fleet over NodeDeploymentState, and the four Phase 5 per-node telemetry dials. Precedent for deleting inert machinery rather than activating it: #522 (driver stability tiers), #507 (discovered-node injection), #525 (GetMemoryFootprint). Deleted: FleetStatusBroadcaster (+ its nested DriverHostStatusHeartbeat), its admin singleton registration and FleetStatusBroadcasterKey, FleetStatusSignalRBridge and its key, FleetStatusHub and its route mapping, and the FleetStatusChanged / FleetNodeStatus / FleetNodeHealth messages. Both Fleet/ directories survive — ControlPlane keeps ClusterNodeAddressReconciler, Commons keeps GetDiagnostics. Docs swept where they claimed a fleet-status channel exists (Telemetry.md's Phase 5 non-migrated channels, Configuration.md, CLAUDE.md); completed-program plan docs under docs/plans and docs/v2 are left as the historical record they are. Build 0 errors, 868 warnings — byte-identical to master's rebuild baseline. ControlPlane.Tests 231/231, AdminUI.Tests 1109/1109. Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1 |
||
|
|
d33e4e20b5 |
feat(adminui): #546 wire DriverStatusPanel into /hosts driver rows (collapsed expander)
DriverStatusPanel was orphaned — zero references repo-wide — so the Restart and Reconnect driver commands had NO reachable UI at all, despite working end to end over the new gRPC mesh transport. Nothing failed to build, test or deploy while that was true, which is why it went unnoticed. The panel is now reachable per driver row on /hosts, behind a per-row "Controls" expander that is collapsed by default: the table stays scannable, and only the opened panels hold snapshot-store subscriptions. Expansion state is a HashSet keyed by DriverInstanceId held on the page, so it survives the 5 s refresh that replaces every row record. Both rows are @key'd by instance id so the panel — which binds its DriverInstanceId once in OnInitializedAsync — can never be diffed onto a different driver. The panel's Enabled parameter is fed from real config rather than defaulted: HostsDriverInstanceInfo/HostsDriverRow now carry DriverInstance.Enabled, which LoadConfigAsync already had in hand. A snapshot with no matching configured instance is treated as enabled — the row exists only because live health arrived, so "Disabled — not deployed" would contradict the same row. The expander is visible to every AuthenticatedRead viewer; the panel self-gates only its Reconnect/Restart buttons on DriverOperator. A source-scan pin (HostsPanelWiringTests) asserts /hosts still renders the panel and still binds it to the row's own driver, cluster and enabled state — removing the tag would silently restore the orphaned state. Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1 |
||
|
|
4d2dfb5b50 |
test(mesh): step 7 — replace the boundary test with MeshGrpcBoundaryTests and sweep the comments
MeshGrpcBoundaryTests replaces the MeshClusterClientBoundaryTests deleted in step 1. Three
self-seeded single-member clusters sharing the ActorSystem name, joined ONLY by gRPC, driving
the REAL CentralCommunicationActor -> MeshGrpcCommandDialer -> Kestrel h2c ->
MeshCommandAuthInterceptor -> NodeCommandGrpcService -> NodeCommunicationActor -> EventStream:
1. No_cross_mesh_Akka_association_forms_between_central_and_either_site — the program's own
point, kept as a test rather than a live-gate note: each cluster stays single-member and
none ever holds another's address as a member.
2. One_dispatch_through_central_reaches_a_node_in_every_cluster_mesh — the fan, with each
site holding its OWN per-cluster PSK, so a dial that selected the wrong cluster's key
would be refused at the far side.
3. Falsifiability_control_a_dial_carrying_the_wrong_cluster_key_delivers_nothing — without
it, (2) cannot distinguish "the gRPC boundary carried it" from "something else in the
process did". The same node then accepts the right key, so the silence is the auth gate
and not a dead endpoint.
All three run fully offline — no Docker fixture — and pass.
Comment sweep across every remaining clusterclient|receptionist hit in src/ and tests/:
the program label becomes "mesh gRPC command plane", and every comment that described the
deleted transport as live now describes what actually runs (Dps = pair-local default,
Grpc = cross-mesh). mesh_transport.proto's header/service comments are reworded; no message,
field or enum is touched — the contract is locked. MeshCommActorPathTests is reshaped rather
than retired: the two paths still exist and still matter, but what a mismatch costs is now a
misleading Unavailable from the gRPC ingress rather than a silently dropped receptionist send.
The only surviving mentions of the old names are the ones that must survive: the fail-closed
rules that name "ClusterClient" as a retired value refused at boot, their tests, and this
test class's own account of what it replaces.
|
||
|
|
667639e6ab |
fix(mesh): per-endpoint deadline + review fixes — failover survives a hanging central
CRITICAL. The ack deadline was one absolute DateTime computed once for the whole endpoint walk. Against the characteristic WAN failure — a central that HANGS (SYN black-hole, frozen host) rather than refusing — endpoint 1 burned the whole AckTimeoutSeconds and endpoint 2 was then dialled with a deadline already in the past: instant DeadlineExceeded, no packet leaving the node, the surviving central never really tried. Failover looked like it ran and did not. It also contradicted MeshTransportOptions' own documented "applied per endpoint, not per ack". The deadline is now computed fresh inside the loop; headers stay hoisted (read-only, sequential walk). Two test gaps that let that survive are closed: nothing pinned the ackRouter gate (narrowing it back to ClusterClient-only compiled and passed every test while dead-ending every Grpc ack to DPS), and the deadline fact's lower bound accepted any positive timeout at all. Both new pins are mutation-verified. Docs corrected where they overstated the case: duplicate acks CANNOT mis-seal a deployment — ConfigPublishCoordinator.HandleAck keys _acks by NodeId behind an expected-set guard, so a duplicate overwrites its own entry. The single-endpoint rule is defence in depth and a bound on wasted work, not a correctness dependency; and the walk is at-least-once on the deadline path, not at-most-once. |
||
|
|
e1db90f9c9 |
fix(mesh): 1B.1 review follow-ups
Two review items from Task 1B.1, both diagnostic: 1. CentralCommandGrpcService's "actor not ready" Warning omitted the peer and the correlation id while the decode-failure Warning six lines above carried both. These are the only two ways an ack fails to reach the coordinator, and an operator has to correlate either against the node's own log. Decoding has already succeeded on this path, so the DECODED correlation id is free. 2. A fused driver,admin,cluster-MAIN node under Mode=Grpc owes BOTH validator surfaces at once (driver keys AND ConfigServe:GrpcListenPort). The two blocks are independent `if`s; chained as `else if` a fused central node would be graded on one surface only and boot with nowhere for any ack to land. Pinned from both sides plus the fully-configured pass. |
||
|
|
7e7df337cc | feat(mesh): CentralCommandService on the ConfigServe listener | ||
|
|
dd900f970a |
fix(hosts): a driver that never built a tag table reports NO ANSWER, not zero skips
Found on the docker-dev live gate, not in tests. Two drivers that faulted during initialise (rtu-gate, opcua1) each rendered "0 tags" on /hosts against two authored tags apiece, because a ledger that had never committed returned SkippedTagReport.Empty. A zero report is a positive claim -- "this driver skipped nothing" -- and making it on behalf of a driver that never got as far as looking is exactly the quiet inaccuracy #541 exists to remove. GetSkippedTags() and SkippedTagLedger.Snapshot() now return null until the first committed build, so the column renders the same em-dash it already used for a driver that cannot report at all. Both are 'no answer'; neither is 'nothing skipped'. Knock-on: a FOCAS driver whose only init threw now reports null rather than a zero report, which is strictly more honest than the assertion the test originally made. |
||
|
|
39db75083d |
feat(drivers): every driver reports the authored tags it skipped (Gitea #541)
A driver builds its RawPath -> definition table at init and tolerates a
per-tag miss: an unmappable TagConfig, an unparseable address, a
capability-matrix rejection. That tolerance is right -- one bad tag must not
take down the other few thousand. What was missing is any statement of the
fact afterwards. A skip is not an error and happens before any read, so the
driver stays Healthy, errors/5 min stays 0, Last error stays empty, and Last
read advances live off the tags that did map. On the wonder Makino in #540
that reading held while focas-z-34184 ignored 20 of its 22 tags.
New optional capability ISkippedTagReporter, backed by a shared
SkippedTagLedger so the reset/commit/cap rules are one implementation rather
than one per driver. The report -- authored count, exact skipped count, and a
capped sample of RawPath + reason -- rides DriverHealthChanged to a new Tags
column on /hosts, over the Phase 5 telemetry stream. No table: a driver-only
node has no ConfigDb to write to, the lesson from #521.
The issue named eight drivers. It is twelve -- every driver in
DriverTypeNames.All has an authored-tag skip path. Calculation (no scriptId),
MTConnect (no readable DataItem id), Galaxy (no attributeRef) and OpcUaClient
(no nodeId) were unlisted, and OpcUaClient's was the quietest of the twelve:
NamespaceMap drops such an entry with a bare `continue` and not even a log
line. SkippedTagReporterFleetTests pins the invariant reflectively over every
IDriver in src/Drivers/, so a thirteenth cannot re-introduce the silence.
Sql drops a tag at TWO points and its report is the union of both: a blob
that does not map, AND an identifier the 8.1 catalog gate rejects against the
live catalog. The second is what schema drift produces -- a renamed column, a
dropped view -- months after a deployment sealed green, and reporting only
the first would have that driver claim "0 skipped" while polling half its
tags, which is worse than reporting nothing because the column would then be
actively reassuring.
Deliberately additive to driver state, never a change of it. Latching
non-Healthy for a config problem would satisfy both halves of the #527
comms-loss conjunction -- 90 s without a successful read AND non-Healthy --
and a driver whose tags were ALL skipped has no successful reads by
construction, so it would reconnect-loop forever against a healthy device.
Three details that are load-bearing rather than incidental:
- The skip digest is part of the publish fingerprint. A skipped tag leaves
every other fingerprint component identical to a clean driver's, so without
it PublishHealthSnapshot's dedup swallows exactly the publish carrying the
signal -- the trap that already bit the rediscovery and host-status
channels. The digest covers the sample, not just the counts: a redeploy
that fixes one tag and breaks another leaves both counts unchanged.
- The count is exact; only the sample is capped, and the tooltip says so when
it is showing fewer than it counted. A truncated list that looked complete
would have an operator fix twenty tags and believe the job done.
- The ledger stages and commits, so an init that throws part-way leaves the
previous report standing. A partial snapshot would read as "we now skip
fewer tags", the opposite of the truth.
The proto field needs no companion presence flag, unlike host_statuses: a
singular message field carries real presence in proto3, and a has_ flag would
collide with protoc's generated HasSkippedTags.
Verified red-first three ways: dropping SkippedTagDigest from the fingerprint
fails the two dedup tests, removing the seam from one driver fails the fleet
guard, and dropping the catalog-gate leg fails the Sql union test. Full
solution builds with zero new warnings against
|
||
|
|
b61fe38823 |
fix(focas): browse-committed fixed-tree tags are readable (Gitea #540)
Authoring FOCAS tags through /raw -> Browse device... produced tags the driver
could never read. Every committed tag read BadNodeIdUnknown forever, and the
failure was silent end to end: the AdminUI accepted it, the deploy gate sealed
green, and the driver reported Healthy with 0 errors while ignoring the tags.
Net effect: the whole fixed-tree surface could not be published through any v3
authoring path. Found cutting wonder-app-vd03 over to v3 against a real Makino
Pro 5 / Fanuc 30i, where 0 of 20 committed tags read while two hand-authored
MACRO: tags on the same device read Good.
A captured browse leaf's id IS its DriverAttributeInfo.FullName, and the fixed
tree emitted "{deviceHost}/{path}" there -- an internal cache key, not an
address. Both authoring paths wrote it verbatim into TagConfig.address, and
FocasAddress.TryParse accepts no such form, so the driver skipped the tags at
init.
Fixed at the emitter rather than by stripping the host at commit, which fixes
the browse-commit flow and the manual picker's tree-select together and leaves
one canonical address form:
- FocasAddress gains a fourth kind, FIXED:<path>, and moves to Contracts so the
AdminUI and ControlPlane can parse without referencing the runtime driver
(#526). A FIXED: read is served from the fixed-tree snapshot the poll loop
already maintains -- no area read, no connection. Writes refuse: nothing in
that tree is a writable location on the CNC.
- The address carries no device. A tag's device comes from its Device row, and
a second routing channel for one fact is what created this defect.
- An authored FIXED: tag arms the fixed-tree poll loop by itself. Enabled
defaults false and the browser force-enables it only for a browse, so the
operator would otherwise browse, commit, deploy, and land on a driver whose
loop never starts -- every tag Bad with a correct address.
- Fixed-tree values are now dated from the last answered poll and go
BadCommunicationError once it is stale (8 cadences, floored at 30s). The poll
loop swallows a failed tick by design, so a dead CNC would otherwise serve its
last snapshot as Good indefinitely -- harmless while nothing could bind to the
tree, not harmless now.
Guardrails, so this class cannot recur silently:
- FocasTagConfigModel.Validate() runs the real parser instead of a non-empty
check, and FocasTagDefinitionFactory.Inspect() warns at the deploy gate, which
covers CSV/API config that never touches the modal.
- The manual picker offered axis/spindle/program/status "parameter groups" --
none of which is a FOCAS addressing space -- and its own default value,
axis:5, was unusable. It now composes PMC / PARAM: / MACRO: through
FocasAddress, so what it emits is parseable by construction.
Tests assert addresses ROUND-TRIP through the parser rather than matching an
expected string: the previous FocasAddressBuilderTests pinned "axis:5" exactly,
which is how a green suite coexisted with a picker nobody could use. Verified
red-first against the old emitter. FOCAS 308, AdminUI 1095, ControlPlane 169,
Core 581 -- all pass, 0 warnings.
The remaining half of #540 -- a driver reporting Healthy/0 errors while
skipping tags at init -- is fleet-wide (eight drivers do this) and is filed
separately rather than patched per-driver.
|
||
|
|
d54f3c8342 | merge: Sql driver Postgres + Oracle providers (managed Npgsql/ODP.NET, dialect-owned binding, live-gated fixtures) | ||
|
|
f13a89dbc3 | docs(mtconnect): final-review nits — two stale read-only comments; task statuses | ||
|
|
08c1728a98 | feat(sql-adminui): Postgres + Oracle in the provider dropdown; docs | ||
|
|
2c19a50bf9 | fix(raw): a superseded manual-entry open can no longer feed the pickers another device's config | ||
|
|
4e3a6e8497 | fix(raw): a stale open can no longer feed the picker another device's config | ||
|
|
a2093b4400 | fix(raw): manual tag entry feeds each row's picker the merged device config (#468 follow-up) | ||
|
|
abb9f8a1cb | fix(raw): tag edit modal feeds the picker the merged device config, not '{}' (#468 follow-up) | ||
|
|
6b3da93151 |
fix(browse): commit the browsed data type, and fix the probe classification the fixture was hiding (#536)
A browse-committed AB CIP / TwinCAT / FOCAS tag bound with its model's DEFAULT
data type, not the one the device reported. A browsed REAL committed as
`{"tagPath":"Pump_1_Speed","dataType":"DInt"}` — and those three drivers decode
the wire bytes by that field, not by the raw row's OPC UA DataType — so the tag
read four bytes of a float through an integer decoder and published a plausible
wrong number with no error raised anywhere. FOCAS was missed when #536 was filed.
The type is CARRIED, not derived. Reverse-mapping the leaf's driver-agnostic
DriverDataType looks like the smaller fix and is wrong: SInt/Int/DInt/USInt/UInt
all collapse into Int32 on the way out of the driver, so that version would bind
a 16-bit INT as a 32-bit DINT while appearing to fix the REAL. Drivers now state
their own type name on DriverAttributeInfo.NativeDataType, which reaches the
picker as AttributeInfo.AddressFields["dataType"] and the commit mapper from
there. A leaf that states nothing keeps the model default — the pre-#536
behaviour, kept deliberately as the fallback rather than a guess.
Numeric strings are refused before parsing: Enum.TryParse accepts "9" for any
enum and Enum.IsDefined then confirms it, so an unguarded parse would bind a tag
to a type nobody named. A test caught this in the first version of the guard.
--- and the other half, which the fixture was hiding ---
Test Connect on a device with NO authored tags — every AB CIP device at the
moment an operator first presses the button — reported "CIP handshake failed"
against a healthy controller. That was written down as a fixture limitation
("ab_server doesn't implement @raw_cpu_type"). Both halves of that were wrong:
* @raw_cpu_type is not a libplctag special tag at all (only @raw, @tags and
@udt/ are), so it goes out as an ordinary symbolic name that no controller
defines, and the controller's "tag does not exist" IS the successful answer.
* ab_server answered an unresolvable tag path with CIP 0x03 where a Logix
controller answers 0x04 — ErrorBadParam vs ErrorNotFound, which the probe
classifies oppositely. Fixed in vendored patch 0002.
* With the fixture then telling the truth, the real defect surfaced:
AbCipDriverProbe.IsReachableException matched the native C status spellings
("STATUS_NOT_FOUND"), but libplctag.NET throws with the MANAGED enum name
("ErrorNotFound"). Those substrings can never match, so the reachable
classification could not fire on the exception path — which is the path every
no-authored-tags probe takes. This was failing on real hardware too, not just
against the sim. It now recovers the Status and defers to IsReachableStatus,
so there is one classification rather than two that can drift.
Rejected: switching the fallback to @tags. libplctag builds a tag-listing tag
with NO network I/O, so it reports OK against any TCP listener — measured green
against a Mosquitto broker.
Verification: full solution suite green. Falsification runs confirm exactly the
intended tests go red — 9 for the type carry, 3 (the reachable statuses only) for
the probe classification. Live on docker-dev: browse-committed TestString/
Motor_Run/TestSINT now store String/Bool/SInt, alongside last session's
Pump_1_Speed still holding the wrong DInt. TestSINT is the falsifier — its row
DataType is Int32, identical to TestDINT's, so no reverse map could have produced
"SInt".
Known consequence: pre-existing browse-committed tags keep their wrong dataType;
the fix applies to new commits only.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
|
||
|
|
1a1dbc3f00 |
fix(uns): enforce the UNS segment rule on every authoring path (#535)
An area or line could be named "Packaging" or "Line 1", save cleanly, and then fail the NEXT deployment with UnsSegmentInvalid. Because a deployment snapshots the whole database, one badly-named area blocked EVERY cluster's deploy - and whoever hit that was usually not whoever typed the name. Only the equipment form carried the rule; the deploy gate held its own private copy. The rule now lives once, on Configuration.Validation.UnsSegment, and both ends call it. DraftValidator no longer restates it. Enforced in UnsTreeService, not just on the forms: - Create/Update Area, Line and Equipment reject an invalid name before touching the row. - The CSV import reports a bad name as an ERROR, not a skip - a skip means "you already have this row", which would tell the operator the equipment exists when it does not. Good rows in the same batch still insert. A form attribute could never have covered the import, and with no bUnit in this repo a rule only a form enforces is also a rule no test can reach. The forms keep an attribute for the immediate message, but it now references the shared pattern rather than restating it - a second copy is how these drifted apart. One behaviour change beyond the fix: UnsSegment.AttributePattern admits "_default", which the equipment form's hand-written literal rejected. The form was stricter than the gate it was mirroring, so a _default row was uneditable through the AdminUI. Tests: 41, falsified with three production mutations - dropping the CreateArea guard reds exactly the CreateArea rejections, turning the import error back into a skip reds only the import test, and narrowing AttributePattern reds only the attribute/IsValid agreement. Every rejection is paired with a name that must still be accepted, or a guard that refused everything would pass. Live-verified on docker-dev: the area modal now refuses "Packaging" in place with the rule spelled out, "packaging-b" saves, and a CSV import of two rows reports Inserted 1 / Skipped 0 / Errors 1 naming the offending row - the path no form attribute reaches. Rig cleaned up and a further deployment sealed. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
d542ab5b7c |
feat(security): author ACL grants from the real tree, not free text (#520 stage 7)
The last stage of #520. Enforcement landed in stages 5-6; this closes the authoring end, where a grant could be saved, deployed and sealed green while resolving to nothing. Scope kind and scope target are now chosen TOGETHER from a picker over the cluster's raw and UNS trees (AclScopePickerModal -> AclScopeTree, backed by IAclScopeService). They were previously an unrelated dropdown and a free-text box, so "RawDevice + a TagId" was a well-formed row. Because the trees are rooted at the grant's own cluster and each node supplies its own kind, NodeAclScopeCrossCluster, NodeAclScopeIdUnexpected, NodeAclScopeIdMissing and NodeAclScopeKindRetired all become unauthorable by construction. CheckScopeAsync mirrors DraftValidator.ValidateNodeAclScopes rule for rule and blocks the save when a scope resolves to nothing - re-checked on submit, not trusted from form load, because a row whose entity was deleted since is exactly where the operator never touches the picker. The list page marks such rows unresolved with the reason. The principal field suggests known principals and reports how many live keys reach the one typed; reaching nobody warns rather than blocks, since authoring ahead of minting is legitimate. Deliberate departures from the plan line, all recorded in the design doc: - The banners are reshaped, not removed. "Not enforced" stopped being true at stage 6, but enforcement is still a per-node flag the AdminUI cannot see, so a narrow grant really does confer nothing on a default-configured node. - A Cluster row produces a NULL ScopeId. The deploy gate rejects one that carries an id, so filling in the cluster id would author undeployable rows. - AclScopeTree is a new component rather than a third mode on RawTree, which already carries the /raw editing tree and the equipment reference picker. - UNS tags are not offered: a UNS signal is a UnsTagReference, and a Tag grant already covers the raw node and every UNS projection of it. Also fixed: the ACL editor had a DataAnnotationsValidator and no ValidationSummary, so an invalid NodeAclId made Create a silent no-op. Tests: 30 in AdminUI.Tests/Acls, falsified with six production mutations - each turned exactly the intended tests red and no others. Live gate PASSED on docker-dev, 11 legs; both central containers asserted on the same image by container id. The pair that matters is legs 8 and 11: the page and the deploy gate reject the same row with the same reason. Legs 5 and 9 are the positive controls - without them the gate passes against a page that refuses everything. Not covered: UNS-realm scope selection (SITE-A has no UNS areas). Rig restored to zero ACL rows. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
00aa486677 |
feat(security): enforce node ACLs on read, browse and subscribe (#520 stage 6)
Completes data-plane enforcement behind Security:Acl:Enabled. Read (every attribute, not just Value), Browse, TranslateBrowsePath, CreateMonitoredItems, SubscribeToEvents and SetMonitoringMode now consult scoped NodeAcl grants. With the flag off nothing changes. Four things went beyond the stage as written, each because leaving it out would have made the feature look like it worked: - Browse needed ancestor visibility. The trie inherits downward, and a client reaches a deep node by browsing the nodes above it, so without this every grant narrower than the cluster was authored, shipped and unreachable. It is a separate non-inheriting marker, NOT a synthesized Browse grant on each ancestor: the additive downward walk would carry such a grant from Plant onto Plant/Siemens/dev9 and every other sibling subtree. Pinned by a test that goes through the evaluator — probing the trie helper directly passes against the broken design, because a sibling is absent from the trie either way. - Revocation had to reach LIVE subscriptions. Every other operation re-asks per request; a subscription is authorized once and then streams, and streaming is how machine consumers actually read this server — so stopping only the re-asking operations would have made revocation close to cosmetic. IDataPlaneAuthoritySource gained a Changed event. A denied item is queued BadUserAccessDenied and then DETACHED from its MonitoredNode2 fan-out, not set MonitoringMode.Disabled. Disabling discards the item's queued notifications, so the client is silenced without ever being told why. The over-the-wire test caught this; the unit-level path reports the item as stood down either way. Detaching is also reversible, so a restored grant resumes the feed with no client action. - The decision cache holds the grant WALK, not the decision. Grants and the trie are fixed for a generation; a key's ExpiresUtc passes with the clock, so caching the whole decision would let an expired key keep working until the next deploy — the stage-5 open-session hole in a subtler form. - TranslateBrowsePath is gated, without which browse filtering is decorative: a client refused a browse asks TranslateBrowsePathsToNodeIds for the same path. Found en route: UserAuthorizationState's staleness ceiling couples two clocks. MembershipResolvedUtc is stamped from DataPlaneAuthorizer's TimeProvider while IsStale is evaluated against TriePermissionEvaluator's; they are the same instance in production and diverge the moment anything injects a test clock, at which point the evaluator denies EVERYTHING with a verdict indistinguishable from "no grant matched". Stage 5's claim that these predicates cannot fire was accidentally true; they are now disabled explicitly. Also fixed: ContinuationPoint.NodeToBrowse is the manager HANDLE, not a NodeState. The declared type is object, so the wrong cast compiled cleanly and silently yielded null — skipping the browse source gate entirely. Falsified: disabling the transit marking reddens exactly the three tests that assert transit works; implementing transit as an ancestor grant reddens the sibling-leak test; skipping the fan-out detach reddens the revocation test. Full solution suite green. The stage 8 live gate has NOT run yet. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
f692f6afe4 |
feat(security): enforce node ACLs on write, alarms and HistoryRead (#520 stage 5)
`Security:Acl:Enabled` (default false) makes scoped `NodeAcl` grants decide data-plane authorization at the three seams that have one, and gives HistoryRead a check it never had. Read, Browse and Subscribe stay ungated — stage 6. The ACL decision REPLACES the server-wide role check rather than chaining with it. Chained, a grant would have to confer the role as well as pass the scope check, and only Cluster-scoped grants confer a role — so every narrow grant would have stayed inert and the flag would have looked inert too. The load-bearing test is an ALLOW: a session carrying no roles at all writing successfully on the strength of its grant. A deny-only test passes against a build where the ACL is never consulted, because the role gate denies too. Found en route: the principal never reached the session. The authenticator passed it as OpcUaUserAuthResult.DisplayName, but RoleCarryingUserIdentity derives DisplayName from the presented token — for a key-bearing client that is the static username `apikey`, identical fleet-wide. So the trie's matching key was dropped at the identity boundary, and the audit ClientUserId on a rejected write recorded `apikey` for every consuming system. Principal and ApiKeyId are now carried explicitly. Beyond the stage as sketched: - Revocation reaches an OPEN session. Every decision re-checks the authenticating key against the current snapshot; without it a key revoked by a deployment kept its authority until the client chose to reconnect, which for a machine-to-machine consumer can be indefinitely. - UserAuthorizationState is built per CALL, not per session. The per-session shape exists so an LDAP session can re-resolve membership that changed out of band; nothing can change out of band under API keys, so the generation stamp is the whole invalidation signal and a per-call record picks it up for free. IsStale/NeedsRefresh therefore cannot fire here and are documented as vestigial. - The trie is built inside DataPlaneAuthorityState.Apply, under the same generation as the snapshot, rather than by a second wiring at the publish actor. An uninstalled trie denies everything — indistinguishable from working enforcement. Deleting the install turns 13 of the 22 new tests red. - The deploy log reports what the BUILD dropped instead of re-deriving it. The old count agreed with the builder on one of its four drop reasons; a rule with a blank ScopeId, a retired scope kind, or a path not starting at a realm vanished with the log reading zero. Both IApiKeyStore implementations widened to the full grant set. The narrowing was redundant — ApiKeyInterimRoleMapper applies the same filter itself — and became a trap once scope was enforced. Pinned by asserting the roles are unchanged, with the two grants carrying different flags so it cannot pass by accident. Falsified by mutation: enforcement never engaging, the write seam ignoring the ACL, the realm dropped from the scope, the revocation check removed, and the trie never installed each turn the intended tests red and no others. Full solution suite green. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
3a6b2a1daf |
feat(acl): variable-depth scope model + the scopePaths producer (#520 stage 3)
Makes the /raw device tree addressable by an ACL rule, and builds the
scope-path producer PermissionTrieBuilder has accepted since it was written
but which had no caller anywhere.
The plan for this stage said "add NodeHierarchyKind.Raw, whose path is the
RawPath segments Folder/Driver/Device/TagGroup/Tag". That shape is wrong.
RawFolder.ParentRawFolderId and TagGroup.ParentTagGroupId are both
self-referencing, so folders and tag groups each nest without bound and a real
RawPath is folder…/Driver/Device/group…/Tag. NodeScope was fixed-arity and
PermissionTrie.CollectMatches was five hardcoded steps, so the scope model
could not address a real raw tree at all. NodeScope is now {ClusterId, Kind,
Segments} and the walk is a segment loop. The trie STRUCTURE was already
variable-depth (NodeAclPath.Segments is a list, Children is a recursive
dictionary), so only the walker and the scope record had to change.
Four decisions worth keeping:
- The namespace level became the realm. Level 1 gated on NodeScope.NamespaceId,
but v3 has no Namespace entity — the snapshot was retired when the address
space went dual-namespace, and the identifier appears nowhere in production
outside NodeScope. So the level could only ever fail to match, which silently
made every sub-cluster grant unreachable while cluster grants kept working.
It is now a realm token derived from the scope's Kind, not carried on it, so
the walk and the producer cannot disagree about its spelling.
- Provenance comes from the granting row's own ScopeKind, recorded on TrieGrant
at build time. Depth-derived provenance could not name a raw level at all,
since the depth of "Device" varies with folder nesting.
- The trie comparer moved from OrdinalIgnoreCase to Ordinal. Raw sibling-name
uniqueness is ordinal, so Speed and speed can both exist under one device and
a grant on either would have matched both.
- The null-scopePaths "deterministic test mode" is deleted. It planted
unresolvable rows at a direct child of the trie root, a position the walker
cannot reach, so the grant looked placed and could never match — and every
test using that mode proved nothing about production placement. scopePaths is
now required, and a row that does not resolve is dropped with a diagnostic.
A scope resolves to a LIST of paths: a raw tag projected into N equipments is
reachable at N+1 NodeIds and a write through any of them lands on the same
driver reference, so a Tag-scoped grant covering only the raw node would be
bypassable through a UNS one. The lookup is keyed on (ScopeKind, ScopeId), not
ScopeId alone — ScopeId has no FK and no type discriminator, so an id collision
across entity types would hand a grant the wrong node's paths.
Also closed here, all found by review rather than asked for:
- NodeAcl rows had no deploy-time validation of any kind and were not reachable
from DraftValidator at all (DraftSnapshot carried no NodeAcls). They are now
gated for dangling ids, cross-cluster scopes, blank/contradictory ScopeId, the
retired FolderSegment kind, and undefined ordinals.
- ConfigDbApiKeyStore conferred roles from Cluster-scoped grants authored in ANY
cluster, because it filtered on scope kind with no ClusterId predicate while
ArtifactApiKeyStore read an already-cluster-filtered snapshot. On a fused
admin+driver node that was a cross-cluster over-grant. Its doc comment claimed
the two stores matched.
- The two AdminUI ACL banners still said enforcement was LDAP-group -> role
mapping, which stages 1/2 made false in both directions.
- The /apikeys page was never classified in PageAuthorizationGuardTests, so that
test has been red since the key-minting commit merged — I did not run
AdminUI.Tests before merging stage 4.
Falsified rather than assumed: 8 mutations against the trie tests, 5 against the
deploy gate (including one proving a cross-cluster row is not silently
mis-diagnosed as unresolved), a staged red->green for the over-grant regression,
and the realm gate, the comparer and the malformed-path guard each broken
individually to confirm only their own tests go red.
Node ACLs are still not ENFORCED — nothing constructs a NodeScope or calls the
evaluator yet. That is stages 5 and 6; this stage makes the model able to
express what those will enforce.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
|
||
|
|
c1771dc271 |
docs(acl): correct the API-key revocation warning after live verification (#520)
The /apikeys page claimed revocation "takes effect on a node only after the next deployment". The live gate showed that is wrong for the node the operator is most likely looking at: revoking through the UI denied the key on the VERY NEXT request against the fused admin+driver node, because ConfigDbApiKeyStore reads per request. The deployment delay applies only to driver-only nodes, whose keys ride the artifact. Reworded to say both, and to tell an operator to assume the slower behaviour when revoking a compromised key — which is the decision the warning exists to inform. Found by doing the thing rather than reasoning about it: the previous wording looked obviously correct until the revoked key was actually re-presented. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
087a969ee6 |
feat(acl): API key minting — AdminUI page + admin service (#520)
Pulled forward from stage 7 because without it the feature is unusable and un-live-gateable: there was no way to create a key short of hand-inserting a row and computing an HMAC by hand. The minting logic is an IApiKeyAdminService in Core.Authorization, NOT logic in the Razor page — this repo has no bUnit, so anything only a page can reach is untestable, and minting credentials is not where that belongs. The page is a thin shell over it. Moved to Core.Authorization so both ends can reach them: ApiKeyOptions (was in Host) and OpcUaPrincipals (was in OpcUaServer.Security). The OPC UA server resolves principals; the AdminUI must refuse to mint a key claiming a reserved one. OpcUaServer already gained a Core reference in stage 1b, so no new edge — AdminUI gains one. ApiKeyOptions is now bound UNCONDITIONALLY rather than in the driver branch: a driver node needs the pepper to VERIFY keys and an admin node needs it to MINT them, and getting that wrong on either side is a silent authentication failure rather than a startup error. Validation rules, all covered: the reserved 'anonymous' principal is refused case-insensitively (so "ANONYMOUS" cannot slip past into a distinct principal that the evaluator would then match case-INsensitively against anonymous's grants); blank name/principal; a principal longer than the column, rejected rather than truncated, because silent truncation yields a key that authenticates and is granted nothing with no visible cause; a past expiry. Generation runs BEFORE the DbContext is opened so an unconfigured pepper surfaces as a clear error instead of a stored row whose hash nothing can verify. The page shows the plaintext ONCE and says so; it is held in component state and written nowhere else, because the server keeps only a hash. Revocation is flagged in the UI as taking effect only after the next deployment — driver-only nodes have no ConfigDb, so keys ride the artifact. FleetAdmin-only (Administrator), not ConfigEditor: this mints credentials. Core.Tests 68 green. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
4d376f727f |
refactor(acl): NodeAcl.LdapGroup -> Principal, with the proc that reads it (#520)
Stage 1a of the API-key ACL design. Behaviour-neutral: the trie walker already matched an opaque string, so only what produces that string changes. No enforcement is wired by this commit and none of the two live role gates move. Renamed through the ACL model: NodeAcl.Principal, TrieGrant.Principal, MatchedGrant.Principal, AuthorizationDecision.Principal, UserAuthorizationState.Principals, and PermissionTrie.CollectMatches's parameter. LdapGroupRoleMapping is a DIFFERENT entity that also has an LdapGroup column and is deliberately untouched — it backs AdminUI login, which keeps LDAP. The migration is the interesting part. EF scaffolds RenameColumn/RenameIndex, so rows survive — but it cannot know that dbo.sp_ComputeGenerationDiff checksums NodeAcl.LdapGroup. That proc is created in V3Initial.StoredProcedures and never redefined since, and SQL Server does not validate a procedure body when a column is renamed out from under it: the object keeps reporting healthy and fails at CALL time with Invalid column name, silently breaking config-drift detection. Verified against the live dev DB that the deployed proc really does reference the column. The migration therefore re-emits the proc, as one parameterised template shared by Up and Down so the two cannot drift. Prose that describes what is enforced TODAY (fleet-wide LDAP group -> role) is left alone, because it is still accurate until stage 2 lands. UserAuthorizationState's refresh machinery is retained unchanged but now carries a note that it is LDAP-shaped and largely vestigial here: an API-key principal set cannot change out of band, since keys and ACL rows both ride the deployment artifact, so the generation stamp rather than the freshness timer is the real invalidation signal. 41 authorization tests pass; solution builds clean. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
803f4e6efe |
refactor(sql): split ISqlDialect/SqlServerDialect into a .Dialect leaf (#526)
`Driver.Sql.Browser` referenced the runtime `Driver.Sql` project. The AdminUI references that browser, so the whole SQL driver runtime — and `ZB.MOM.WW.OtOpcUa.Core` through it — sat in the AdminUI's build/deploy graph. This is the same layering violation #512 removed from the MQTT browser, in a second driver, and it is why #512's expected removal of `Core.dll` from the AdminUI's output did not happen. MEASURED, both directions, on a clean AdminUI build: before: ZB.MOM.WW.OtOpcUa.Core.dll + ZB.MOM.WW.OtOpcUa.Driver.Sql.dll present after: both absent The old csproj comment's premise was sound and survives — the dialect's catalog SQL *is* the browse engine, so it must be shared rather than duplicated. What was wrong was the conclusion that sharing it required referencing the runtime driver. `ISqlDialect`/`SqlServerDialect` depend on nothing in `Driver.Sql`, so they move to a `.Dialect` leaf that both consume. This is the `.Transport` shape, not the cheap one: `ISqlDialect` exposes `DbProviderFactory` and `SqlServerDialect` returns `SqlClientFactory.Instance`, so `.Contracts` (deliberately provider-free) cannot hold them. Assembly name is `.Dialect`; the NAMESPACE stays `ZB.MOM.WW.OtOpcUa.Driver.Sql`, matching the `Driver.Mqtt.Transport` precedent — the extraction cost zero `using` changes. Two dependencies the cut edge surfaced as the implicit ones they were: - The AdminUI itself read `SqlDriver.DriverTypeName` in three places — the tag editor map, the tag config validator, and the Sql address picker. All three now read `DriverTypeNames.Sql`, which is exactly what that constant resolves to and exactly the repoint `SqlDriverBrowser`'s own comment had deferred until a factory was registered against the shared constant. One exists now. - `SqlDriverFormContractTests` asserts the AdminUI form's emitted JSON against the runtime factory that reads it, so it genuinely needs the runtime driver. `AdminUI.Tests` now references it explicitly. A test project referencing a runtime driver is fine — tests are not in the AdminUI's deploy graph. New guard: `DriverBrowserLayeringTests` (Commons.Tests) scans the csproj graph of every `*.Browser` project in the tree, transitively. It reads csproj files rather than loaded assemblies because the cost is a build-graph cost — the compiler emits no assembly reference for an unused `ProjectReference`, so `MqttBrowserLayeringTests`' assembly-reference approach cannot see that case. The two are complementary and each now points at the other. Falsified three ways, each red then green again: the direct reference re-added to the browser; the same reference one hop out via `.Dialect` (proving the walk is really transitive); and both controls — browsers-discovered and references-parsed — which exist so an empty discovery cannot pass the absence assertion vacuously. #526's claim that the reference "carries no comment at all" was wrong; it carried a detailed one from the scaffold commit. Corrected on the issue and in the design doc's project table, which had recorded the deviation as deliberate. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
7f2108dcf2 |
feat(mqtt): Sparkplug primary-host STATE publishing, Primary-gated (#511)
`ActAsPrimaryHost` was accepted by config and by the AdminUI form and did nothing but
log a warning. It now delivers the whole three-part contract or none of it: a retained
`ONLINE` on `spBv1.0/STATE/{hostId}`, a matching retained `OFFLINE` armed as the MQTT
Last Will, and an explicit `OFFLINE` on a clean stand-down.
**The claim is a dedicated connection, not a message.** A Will can only be registered in
the CONNECT packet — it cannot be added to a live session, changed, or withdrawn. So a
claim that is acquired and released at runtime cannot ride the long-lived ingest session.
`SparkplugPrimaryHost` opens its own connection (client id `{clientId}-spbhost`, forced
clean-session) when the node gains Primary and closes it when the node loses Primary; the
connection's lifetime *is* the claim, so every leg follows from its lifecycle. Ingest is
untouched by a role change — no dropped subscriptions, no lost birth cache, no data gap at
the Secondary->Primary transition.
**Primary-gated** (owner decision, recorded on the issue). Both pair nodes subscribe
independently, so an ungated claim means both claim the same host id — and the sharp
failure is not the two fighting over the retained STATE, it is that the SECONDARY's death
fires its Will and publishes OFFLINE while the Primary is healthy, stopping every edge node
in the group. Registering the Will only on whichever node is Primary at connect time fails
the other way: a node that later gains Primary would publish ONLINE with no Will behind it.
New seam: `IDriverPrimaryRoleSource` (`Core.Abstractions`) carrying the *data-plane* verdict
(`PrimaryGatePolicy.ShouldServiceAsPrimary`), not the alarm-drain verdict — an unknown role
with a driver peer present must deny. Registered unconditionally by `AddOtOpcUaRuntime`,
deliberately NOT alongside `IRedundancyRoleView`, which `AddAlarmHistorian` registers only
when that section is enabled: piggybacking would leave a pair with no alarm historian
falling back to "claim unconditionally". Polled on a 1s timer rather than evented — a
process singleton raising events at per-instance drivers outlives every driver it holds.
Accepted trade: a brief edge-visible OFFLINE window during failover. That is a genuine
state transition, not a glitch to hide.
Live-gated 5/5 against the Mosquitto fixture, including the Will leg — `AbandonForTests`
drops the socket with no DISCONNECT, because a clean disconnect makes the broker discard
the Will by protocol rule, so a test driven through `StopAsync` would observe the
stand-down OFFLINE and pass against an implementation that never armed a Will. Falsified:
removing the Will turns that leg and only that leg red.
Also corrects two stale claims found en route: the AdminUI form still said MQTT tags are
read-only (#508 shipped), and the driver doc still said nothing consumes `IRediscoverable`.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
|
||
|
|
72be19225d |
feat(mqtt): write-through (IWritable) — Plain publish + Sparkplug NCMD/DCMD (#508)
MqttDriver implemented no IWritable, so every MQTT node materialized read-only
regardless of what the operator authored. It now publishes.
Plain -> the tag's writeTopic; UTF-8 text (Raw/Scalar) or a bare JSON
literal (Json)
Sparkplug -> DCMD for a device metric, NCMD for an edge-node metric, carrying
the metric BY NAME with an explicit Datatype and no seq
Both at QoS 0, retain:false. Retain is deliberately not configurable — a retained
command is replayed by the broker on every future subscribe, including the
device's own reconnect, so one stale write would be re-applied forever.
writeTopic is a new, separate TagConfig key, and its ABSENCE is meaningful: the
write is refused BadNotWritable and the node is discovered ViewOnly. The issue's
"do not skip" warning drove the design — the one outcome worse than read-only
nodes is a node that looks writable, returns Good and publishes nothing. Reusing
the read topic would be worse still: it would echo back and read as a confirmed
device value. Browse-time writability is computed by the SAME encoder the write
path uses, so a node cannot advertise writability it would then refuse.
Good means published, not applied — MQTT has no application-level write ack, so
this is Galaxy's optimistic-Good posture and inherits its property: a failed
DEVICE write can never be surfaced. A failed PUBLISH is reported Bad; the
optimism covers what the device did with the command, never whether it was sent.
WriteIdempotent stays default-off.
The encoder is pure and lives in .Contracts, so both wire shapes are testable
without a broker. Unrepresentable values and types with no Sparkplug encoding are
refused rather than coerced — a Reference must not silently become a String on
the wire, and "not-a-number" must not become 0 on a live plant.
LIVE GATE PASSED against the real Mosquitto fixture on 10.100.0.35: 21/21
integration tests, including 6 new ones that observe the published message with
an INDEPENDENT broker subscriber — a fake asserting "publish was called" could
not tell the feature working from the feature publishing to the wrong topic.
The gate earned its keep: the NCMD test initially failed because NCMD is a SHARED
channel — the driver publishes its own rebirth request (Node Control/Rebirth) on
the very topic an edge-node metric write uses, and it arrived first. Correct
driver behaviour, wrong test; the watcher now matches on metric name. Documented,
because anything consuming that topic needs to know. DCMD has no contention.
Offline: 24 encoder + 9 driver tests. The four new status constants are NAMED so
StatusCodeParityTests can see them (#497/#519) — it went 258 -> 262 and validated
each against the pinned SDK.
Also corrects the Mqtt.md "Known gaps" table: prunes the six rows closed in this
round, and fixes the #507 row, which still described rediscovery as inert after
that issue was closed as superseded and its injection path deleted.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
|
||
|
|
7f53bd96ec |
fix(mqtt): close #509, #510, #512, #513, #514
Five MQTT tracker items — four AdminUI/authoring defects plus the .Browser layering exception. No runtime driver behaviour changes. #513 payloadFormat in a Sparkplug blob. MqttTagConfigModel.ToJson wrote the key unconditionally. Sharper than the issue states: PayloadFormat is the one Plain field with a NON-NULLABLE typed backing, so the write did not preserve a retyped tag's leftover — it INVENTED "payloadFormat":"Json" in a Sparkplug tag that never had one. Now Plain-only; preserve-unknown-keys is pinned unchanged. #509 slashed Sparkplug metric names. The mapper already carried metricName verbatim; only the tag Name (a RawPath segment) tripped RawPaths.ValidateSegment, which refused the batch whole — including Node Control/Rebirth, mandatory on every Sparkplug edge node. ToRawSegment coerces the Name and leaves the address untouched. Coercion is not injective, so DescribeNameCollisions refuses a colliding set BY NAME: silently merging two metrics into one tag would be worse than the refusal it replaces. Applies to every driver, not just MQTT — the argument is about what a Name is, not about who produced it. The sanitiser is pinned against RawPaths.ValidateSegment rather than a copied charset. #510 stale rebirth affordance. _canRebirth was probed once at browse-open and sessions are reaped for idleness, so a modal left open offered an action whose token no longer resolved. Re-probed on arm AND on confirm (the reap can land between the two, and confirm is the one path that publishes to a live broker); the affordance retires with an explanation instead of vanishing or erroring. #514 rebirth on a quiet plant. The tree is birth-driven and births are never retained, so a plant that birthed before the window opened showed an empty tree — and the scope came only from a tree selection, so the one action that would fill the tree could not be armed. The session already accepted a bare {group}/{edgeNode} ("the prime rebirth target"); this adds the affordance. Edge-node scope only, not a group broadcast. The rule is extracted to SparkplugRebirthScope so it is testable — this repo has no bUnit — and is advisory: the session re-resolves and refuses before publishing. #512 .Browser -> .Driver layering. TWO extractions were needed, not the one the issue anticipated: it costed this as "the client-options builder", but the browse session decodes births itself, so moving only that would have left the reference exactly where it was. - MqttClientOptionsFactory (TLS, PEM CA-pin validator, credentials, protocol mapping) -> new leaf .Transport project. NOT .Contracts: that is deliberately transport-free and MqttClientOptions is an MQTTnet type, so .Contracts would hand MQTTnet to ControlPlane. This is the fix the .Browser csproj comment had already prescribed, against the issue's suggestion. - The Sparkplug protocol layer (SparkplugTopic/MessageType, SparkplugCodec, RebirthRequester) -> .Contracts, beside the Tahu wire schema it encodes. Still exactly one copy of the TLS/CA-pin logic; MqttBrowserLayeringTests guards the graph both ways. Measured, not assumed: Driver.Mqtt.dll, Polly.Core and Serilog are now absent from the AdminUI's output. Core.dll remains, because Driver.Sql.Browser has the SAME violation, undocumented — the old comment blamed this browser for Core and was wrong. Filed separately rather than fixed in passing. Full suite green apart from the 7 known pre-existing failures (4 AbLegacy integration, compose profiles not up; 3 Host.IntegrationTests). Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
ce589569fe |
fix(hosts): pluralise the host count; live-verified on docker-dev
Live /run verification of #521 on the docker-dev rig (this repo has no bUnit, so a Razor binding bug passes every unit test and review). Findings: - The Hosts column renders all three states correctly against real drivers: "—" for the probe-less Calculation drivers, "1 host" for healthy Modbus/Sql, and a "1 / 1 DOWN" warn chip for the faulted OpcUaClient, whose tooltip reads "opc.tcp://10.100.0.35:50000: Unknown since 2026-07-30 08:51:23Z". - That tooltip vindicates counting HostState.Unknown as degraded: the faulted driver's probe never completed a tick, so it reports Unknown — treating Unknown as healthy would have shown the one genuinely broken driver in the fleet as "1 host", fine. - **The cross-mesh gRPC telemetry path is verified, not assumed.** site-a is a separate Akka mesh, so its telemetry crosses the Phase 5 gRPC stream the proto change targets, rather than central's in-mesh DPS. It initially showed "—", which is also what a broken mapper would produce; rebuilding site-a turned it into "1 host", proving the has_host_statuses presence flag round-trips over the real wire and that the earlier "—" was version skew. - Mixed-version behaviour is therefore graceful by construction: an old node's payload has the flag clear, which decodes to null and renders "—" — not a crash, and not a false "0 hosts". - The DropDriverHostStatusTable migration applied cleanly (the table is gone from the rig's ConfigDb; DriverInstance / DriverInstanceResilienceStatus intact). Only fix needed: "1 hosts" → "1 host". Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
cbb882293b |
refactor(drivers): delete the inert driver-tier recycle machinery (#522)
The tier system was documented, operator-authorable, and inert. Deleted rather than activated,
because its premise is gone rather than merely unused.
"Tier C" meant a driver running out-of-process behind an IDriverSupervisor that could restart its
Host without tearing down the OPC UA session. No such process exists anywhere: Galaxy reaches
MXAccess over gRPC to the external mxaccessgw sidecar (PR 7.2 retired the in-process
Galaxy.Host/Proxy/Shared projects) and FOCAS has run in-process since its managed wire client
landed 2026-04-24. Consistently, IDriverSupervisor had ZERO implementations and there was nothing
for one to implement against.
The issue understated the inertness. It says the Tier-C-only protections never engaged, implying
the Tier A/B parts did. They did not: nothing constructs MemoryTracking, MemoryRecycle or
ScheduledRecycleScheduler outside their own unit tests, so the whole Core/Stability recycle layer
was dead — meaning option (a), "pass real tiers", was never a flag flip. It would have meant
writing the wiring that never existed AND arming it.
Deleted: MemoryTracking, MemoryRecycle, ScheduledRecycleScheduler, IDriverSupervisor, the
vestigial DriverTypeRegistry (referenced only by its own tests), and the RecycleIntervalSeconds
knob — which the AdminUI let an operator author and the parser validated while it configured
nothing.
DriverTier itself SURVIVES and is load-bearing: DriverResilienceOptions.GetTierDefaults supplies
the real per-capability timeout/retry/breaker policies via DriverFactoryRegistry.GetTier and
DriverCapabilityInvokerFactory. Only the isolation-and-recycle layer above it is gone.
Deliberately NOT deleted:
- WedgeDetector came along in the same directory and is equally dead in production, but it is
tier-agnostic and is not recycle machinery — it only shares the folder. Restored rather than
swept up in a decision that was not about it.
- IDriver.GetMemoryFootprint() and FlushOptionalCachesAsync() lose their only consumer here.
Removing them touches all 12 drivers and every test stub, so they are documented as
consumerless and filed as #525 instead of buried in this diff.
Compatibility: a deployed ResilienceConfig blob still carrying "recycleIntervalSeconds" parses
cleanly (unknown keys are ignored — guarded by a new test, because a blob that suddenly failed to
parse would fall back to tier defaults and silently discard the operator's real overrides), and
the AdminUI's preserve-unknown-keys bag keeps the key rather than rewriting stored config on an
unrelated edit.
The 01/U-6 knob-inertness guard carried an explicit carve-out admitting RecycleIntervalSeconds was
dormant and out of scope; that carve-out is now gone, so the expected set is literally what the
test's name claims.
Note: Host.IntegrationTests has 2 failures (DriverProbeRegistrationTests.is_idempotent,
PrimaryGateFailoverTests) — verified pre-existing by reproducing both on clean master
|
||
|
|
30d0697c28 |
feat(hosts): surface per-host connectivity on /hosts; drop the unwritable table (#521)
`IHostConnectivityProbe` was a dead surface: eleven drivers implement it, `GetHostStatuses()` had ZERO production call sites, and `OnHostStatusChanged` had no subscriber outside the Galaxy driver's own aggregator. Per-host connectivity was computed by every driver and read by nobody. The issue offered "build the publisher or delete it". The publisher as its entity doc described it — driver nodes upserting `DriverHostStatus` rows — is not buildable: per-cluster mesh Phase 4 gates `AddOtOpcUaConfigDb` on the `admin` role, so a driver-only node has no ConfigDb connection to write rows with. So the capability is kept and the transport changed. `DriverHealthChanged.HostStatuses` now carries the probe result to `/hosts` as a Hosts column. That channel already reached the page, already survives the mesh split via the Phase 5 gRPC telemetry stream, and already replays a last-value snapshot on re-subscribe — so per-host state re-primes after a reconnect without a durable store. Both halves of the interface finally do what they are for: the event triggers a prompt publish, the pull is the source of truth. The point of the column is the case the driver-level state chip structurally cannot express: a multi-device driver stays aggregate-Healthy while ONE of its devices is unreachable. Two traps, both pinned by tests that were falsified against the prod code: - The host digest MUST be in the publish fingerprint. On a single-host-down transition every other fingerprint component is unchanged, so the dedup would swallow exactly the publish carrying the news — the trap that already bit the rediscovery signal. Removing it turns the guard test red, verified. - null (no probe) must stay distinct from empty (probe with no hosts). proto3 cannot tell an absent repeated field from an empty one, hence the explicit `has_host_statuses` flag; collapsing them would render every probe-less driver as one whose devices are all fine. Dropped: the DriverHostStatus entity, enum, DbSet, model config and table (migration DropDriverHostStatusTable — empty on every deployment, so the scaffolder's data-loss warning is moot, and Down() recreates it exactly). Found en route, NOT fixed here: `DriverInstanceResilienceStatus` is the identical defect — no writer, no reader, only a DbSet declaration, while the live data rides the `driver-resilience-status` telemetry channel. Its doc-comment now states that rather than describing the sampler and AdminUI join that were never built. Filed as #524 rather than widening this schema change beyond what was asked. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo |
||
|
|
6a01358b9a |
fix(adminui): guard the driver dispatch maps and close G-1..G-6 (§8.4)
A parity guard already existed for DriverTypeNames <-> the /raw driver picker, but not for the two dispatch maps downstream, so a driver could be registered, offered in the picker, and then have no config form. That is exactly what happened to Calculation (G-1) and to Sql/MTConnect/Calculation on the device modal (G-2) — both survived review because nothing could see them. The maps had to become data first. A Razor @switch compiles into BuildRenderTree's IL, so no test can enumerate its cases; the picker guard works only because RawDriverTypeDialog keeps its data in a field the markup enumerates. Both modals now render from DriverConfigFormMap / DeviceFormMap through <DynamicComponent>, and being public those maps need none of the picker test's BindingFlags.NonPublic fragility. - G-1 CalculationDriverForm.razor — RunTimeout was unauthorable via the UI. - G-2 Sql/MTConnect/Calculation declared single-connection rather than given hollow device forms; each holds one connection at the driver level. - G-3 DriverConfigModal's hardcoded "Galaxy or Mqtt" -> IsSingleConnection, so Sql/MTConnect authors are no longer sent to a device form with no endpoint. - G-4 DriverFormMapParityTests (5, both directions) + DriverDispatchMapParityTests. - G-5 CsvColumnMap entries for Sql, Mqtt, MTConnect. - G-6 RawBrowseCommitMapper Sql branch — and the browser end, which the audit missed: SqlBrowseSession emitted NO AddressFields, so a browsed leaf carried only a column name, and a column alone cannot address a Sql tag. It now travels schema/table/column and the mapper builds a WideRow config from them. A branch alone would have produced a half-built blob. Two findings while writing the guards. The G-6 test showed Modbus and Calculation also hit the generic address fallback — correctly, as neither is browsable — so it asserts the fall-through set EQUALS a documented non-browsable list in both directions; a one-way check would let a newly browsable driver be quietly added to the exclusion list. And TagConfigDriverTypeNameGuardTests was hollow: it enumerated a hand-written TheoryData that had already drifted (omitting Galaxy, Sql and Mqtt), guarding renames but not gaps. Now enumerated from the map with a coverage test facing the other way. Live-verified on docker-dev, since this repo has no bUnit and no unit test reaches Blazor parameter binding: opened Calculation's config (previously "No typed config form"), typed 3500, saved, reopened — the value persisted, so the DynamicComponent two-way binding round-trips. Sql's form renders fully and now reads "This driver holds a single connection, authored above". AdminUI.Tests 930 passed. |
||
|
|
09a401b881 |
feat(drivers): consume IRediscoverable as an operator re-browse prompt (§8.2, #518)
Nine drivers raise IRediscoverable.OnRediscoveryNeeded when they observe that a remote's tag set may have changed — a Galaxy redeploy, a TwinCAT symbol-version bump, an MTConnect agent restart, a Sparkplug rebirth. Nothing in src/ subscribed, so every raise went into the void. Drivers even wrap the invoke in try/catch for "subscriber threw"; there has never been a subscriber. DriverInstanceActor now attaches the event in PreStart and detaches in PostStop, mirroring AttachAlarmSource/DetachAlarmSource. Attach is per-actor, not per-connect: the raise has no connection affinity and can land while the driver is between connects. The detach is load-bearing rather than tidy — the IDriver instance outlives the actor when the host respawns a child around the same driver object, so a missing -= accumulates one handler per respawn, each holding a dead Self. The signal rides the existing driver-health snapshot to /hosts as a "re-browse" chip. It is ADVISORY: the served address space is deliberately not rebuilt, because v3 authors raw tags explicitly through the /raw browse-commit flow and a runtime graft would materialise nodes no operator approved and no deployment artifact records. Two things worth knowing: - PublishHealthSnapshot dedups on a health fingerprint, and a rediscovery raise on an otherwise-healthy driver changes none of the four fields it hashed. Without adding the timestamp to that tuple the dedup swallows the exact publish carrying the signal. Reverting that one line turns 3 of the 5 new tests red, which is how it was confirmed rather than assumed. - The new test stub implements IDriver from scratch instead of deriving from the shared StubDriver, whose GetHealth() returns DateTime.UtcNow — its fingerprint differs on every call, so the dedup never engages and the dedup test would have passed vacuously either way. The planned discovery-result drift detector was NOT built. Modbus, S7, MQTT, AbLegacy and Sql all echo authored config from DiscoverAsync rather than browsing the device, so a discovered-vs-authored diff is permanently empty for them — it would have been another plausible-looking inert seam, which is the class this audit exists to remove. IRediscoverable is the trustworthy signal because the driver asserts it deliberately. DriverHealthChanged, IDriverHealthPublisher.Publish and HostsDriverRow gain defaulted optional parameters, so no existing call site changed. telemetry.proto gains fields 8/9 and both Phase-5 mappers carry them. Runtime.Tests 512 passed / 31 skipped. |
||
|
|
53ede679c3 |
docs+ui(security): state plainly that node ACLs are not enforced (§8.1, #520)
deferment.md §8.1 asked for a decision: wire IPermissionEvaluator into the node manager, or say plainly that ACLs are not enforced. Decision: the latter. The evaluator stays in the tree; #520 tracks the wire-up. Verifying the claim turned up four things worse than the audit recorded: - docs/security.md, not ReadWriteOperations.md, was the highest-risk doc. It claimed an anonymous session is "default-denie[d] any node a session has no ACL grant for". The opposite holds: anonymous can Browse/Read/Subscribe/ HistoryRead the entire address space, and is refused writes and alarm acks only because it carries no roles. - Three of five documented data-plane role strings do nothing. OpcUaDataPlaneRoles declares exactly WriteOperate and AlarmAck; ReadOnly, WriteTune and WriteConfigure are compared against nowhere in src/. The doc called all five "exact, case-insensitive, and code-true". - ReadWriteOperations.md was fiction beyond the ACL claims. OnReadValue has zero occurrences in src/ — the documented read path did not exist. Reads never reach a driver: the node manager is push-model and the SDK serves a Read from the cached pushed value. WriteAuthzPolicy, _sourceByFullRef, _writeIdempotentByFullRef and IRoleBearer are likewise zero-hit, and CapabilityInvoker is not referenced by the OpcUaServer project at all. This file is rewritten rather than bannered. - v2-release-readiness.md claimed a whole enforcement layer shipped — FilterBrowseReferences, GateCallMethodRequests, MapCallOperation, AuthorizationBootstrap, Node:Authorization:* keys. None exist. Whatever landed on the v2 branch did not survive into the shipped tree. The UI change is the operative one: ClusterAcls.razor and AclEdit.razor now warn that a grant is saved and shipped in every deployment artifact but never evaluated, so an operator cannot author a deny rule believing it works. deferment.md gains a §9 execution log tracking §8 remediation. |
||
|
|
9227d03ca8 |
feat(mtconnect): make an MTConnect driver creatable + configurable in /raw (Task 18 Part B)
An MTConnect driver instance could not be authored at all: RawDriverTypeDialog
(the only DriverInstance creation surface) offered a hardcoded 9-entry list
without it, and DriverConfigModal's default: branch renders a warning with no
raw-JSON fallback — so even a hand-inserted row could not be configured and
DriverConfig stayed "{}", on which ParseOptions throws "missing required
AgentUri".
Adds the typed MTConnectDriverForm (the consistent sibling pattern) covering
agentUri / deviceName / the four polling knobs / probe / reconnect, wires the
dispatch case, and offers the type in the dialog.
- All decisions live in the static MTConnectDriverForm.BuildConfigJson +
MTConnectFormModel (plain C#), because this project has no bUnit.
- The wire shape mirrors the driver's private MTConnectDriverConfigDto, NOT
MTConnectDriverOptions: the latter's TimeSpan probe knobs would serialise as
"00:00:05" and never bind to the driver's integer intervalMs.
- arch-review 01/S-6: a non-positive timing knob is REMOVED from the document
rather than written, so ParseOptions substitutes the driver's own positive
default instead of the driver faulting at Initialize on RequirePositive.
Removal (not just skipping) also stops a stale positive value surviving and
disagreeing with what the form shows.
- Unknown top-level keys survive a load/save, so the driver's hand-authored
tags[] surface is not silently deleted by opening the form.
- _jsonOpts carries JsonStringEnumConverter, satisfying the
DriverPageJsonConverterTests fleet guard properly rather than by exemption.
New RawDriverTypeDialogCoverageTests resolves the offered set through
DriverTypeNames.All, so the next registered driver fails here until the dialog
offers it.
|
||
|
|
115a43dd47 |
feat(mtconnect): typed AdminUI tag-config editor + browse round-trip (Task 18 Part A)
Registers the MTConnect typed tag editor in TagConfigEditorMap /
TagConfigValidator (keyed off DriverTypeNames.MTConnect, never a literal) and
adds the razor shell over Task 17's MTConnectTagConfigModel.
The shell stays trivial: the /probe-sourced mtCategory/mtType/mtSubType/units
row is rendered disabled + readonly with NO binding of any kind, and no
inferred-type hint is shown — MTConnectDataTypeInference.Infer() also keys on
the DataItem `representation`, which the tag-config model does not carry, so
calling it here would agree with the browse picker for ordinary items and
silently disagree for exactly the DATA_SET/TABLE/TIME_SERIES ones.
Also fixes the picker -> editor round trip, which was broken in both
directions:
- RawBrowseCommitMapper.BuildTagConfig had no MTConnect branch, so a committed
tag landed as the generic {"address": "<dataItemId>"} while the model read
only `fullName`. The data plane kept working (the driver accepts all three id
spellings), so the only symptom was an empty DataItem-id field in the editor
— and saving from that state stamped fullName:"" over the tag.
- MTConnectTagConfigModel.FromJson now accepts dataItemId/address as fallbacks
(fixing tags committed before this change) and ToJson normalises onto
`fullName`, dropping the aliases so the two spellings cannot drift.
|
||
|
|
b0046d6959 |
feat(mtconnect): typed AdminUI tag-config model (Task 17)
MTConnectTagConfigModel: pure FromJson/ToJson/Validate for the MTConnect tag TagConfig JSON blob, mirroring ModbusTagConfigModel/OpcUaClientTagConfigModel. Fields: fullName (DataItem@id, required), dataType (DriverDataType override, written as an enum name string), mtCategory/mtType/mtSubType/units (probe metadata), mtDevice/mtComponent (author context). Preserves unknown JSON keys across load->save (isHistorized/historianTagname and anything else). Guards against the enum-serialization trap (numeric dataType would fault the driver at deploy) both on write (always TagConfigJson.Set via enum name) and on read (Validate() rejects a dataType that was stored as a bare digit string, since Enum.TryParse silently accepts numeric text). AdminUI.csproj gains a ProjectReference to Driver.MTConnect.Contracts, matching the existing POCO-only driver-Contracts pattern used by the other six typed tag editors. Scope: pure model only (Task 17). The razor editor shell + TagConfigEditorMap/ TagConfigValidator registration is Task 18. |
||
|
|
c3a2b0f773 |
Merge branch 'feat/mqtt-sparkplug-driver'
# Conflicts: # src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeNames.cs # src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Components/Shared/Drivers/DriverConfigModal.razor # src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/EndpointRouteBuilderExtensions.cs # src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/TagConfigEditorMap.cs # src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/TagConfigValidator.cs # src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/ZB.MOM.WW.OtOpcUa.AdminUI.csproj # src/Server/ZB.MOM.WW.OtOpcUa.Host/Drivers/DriverFactoryBootstrap.cs |
||
|
|
123ddc3f40 |
fix(scripteditor): complete + hover absolute RawPaths (#490)
The issue reports a missing feature. The cause is a stale projection, and the
consequence was worse than the gap described.
`ScriptTagCatalog` still emitted `Tag.TagConfig.FullName` — the pre-v3 driver wire
address. Since v3 the mux key is the **RawPath**: `AddressSpaceComposer` harvests the
`ctx.GetTag("…")` literals into `DependencyRefs`, those become `VirtualTagActor`
dependency refs registered with `DependencyMuxActor`, whose `_byRef` is keyed Ordinal
by `AttributeValuePublished.FullReference` — and a driver's wire ref IS the RawPath
(`DriverHostActor._nodeIdByDriverRef` is keyed `(DriverInstanceId, RawPath)`). The
`{{equip}}/<RefName>` form already substitutes to RawPaths at both compose seams.
So the catalog was wrong in BOTH directions, not merely incomplete: completion
offered paths that could never resolve at runtime, while a CORRECT absolute RawPath
got no completion and hovered as "not a known configured tag path". The file's own
comment admitted the raw/UNS catalog was left for "Batch 2/3" and it never came.
Now projected through the shared `RawPathResolver` — the same byte-parity authority
`DraftValidator` and `AddressSpaceComposer` use — so a suggested path is identical to
the one the deploy gate and the runtime compute. A tag with a broken ancestry chain
resolves to null and is omitted: the runtime could not route it either, so offering
it would be a lie. Hover additionally gains the owning `DriverInstanceId`, which the
topology now makes available (it was always null before).
Editor-accepts <=> publish-accepts is preserved: no diagnostic keys off this catalog
(`OTSCRIPT_EQUIPREF` only marks `{{equip}}` paths), so this changes completion and
hover only — it cannot newly reject a script.
The existing tests pinned the v2 contract and were re-authored: a RawPath only exists
if the RawFolder -> DriverInstance -> Device -> TagGroup -> Tag chain does, so the
seed now builds one. Added coverage for group-nested paths, a driver at the cluster
root (no folder segment), a broken chain being omitted rather than guessed, and the
pre-v3 FullName no longer resolving.
Live-gated on docker-dev (rig rebuilt, both central nodes):
- completion, empty literal -> every RawPath incl. group-nested
`opcua1/plc/OpcPlc/Telemetry/Basic/AlternatingBoolean`
- completion, prefix `pymod` -> `pymodbus/plc/HR200X`, `pymodbus/plc/ImportedTag`
- hover `pymodbus/plc/HR200X` -> "Tag · Type UInt16 · Driver MAIN-modbus"
- hover an unknown path -> "Not a known configured tag path"
AdminUI 742/742; script-analysis 55/55; solution builds 0 errors.
|
||
|
|
0f38f48679 |
merge: Modbus RTU-over-TCP transport (#495)
Wave 1 of the driver-expansion program. The branch was complete and live-gated but had never been merged; it sat 15 commits ahead and 50 behind master. Purely additive behind the existing IModbusTransport seam — the application protocol (function codes, codecs, planner, coalescing, write path, probe, materialisation, HistoryRead) is identical across TCP and RTU; only the wire framing differs ([addr][PDU][CRC-16], no MBAP, no TxId). Zero changes to codecs/planner/health. Selected by a new Transport config field (ModbusTransportMode: Tcp | RtuOverTcp), routed through ModbusTransportFactory (throws on unknown mode), with the string-enum guard on options/DTO/factory and a Transport selector on the AdminUI Modbus form. ModbusSocketLifecycle was extracted from ModbusTcpTransport (behaviour-preserving) and is composed by both transports. Descoped by design: direct-serial (System.IO.Ports) and Modbus ASCII — RTU buses are reached exclusively via a serial->Ethernet gateway. No per-tag config changes; the existing per-tag UnitId already makes a multi-drop bus work. Re-validated against current master at merge time (the branch's own gate predates 50 commits of master): no overlapping files, clean merge, solution builds 0 errors, and Modbus 344/344, Modbus.Addressing 161/161, AdminUI 740/740, Runtime 507/507, Configuration 131/131 all pass. Confirmed the Transport selector is still reachable through master's current authoring path (DriverConfigModal -> ModbusDriverForm), so the branch's live /run gate result still applies. |
||
|
|
4cc0215bb4 |
fix(adminui): the cluster-node editor was dead — 500 on load, silent no-op on save
Both defects are PRE-EXISTING (present on master, unrelated to #499) and were found live-verifying the #499 guard, which lives on this page and was unreachable without them fixed. 1. **HTTP 500 on load.** `FormModel.ServiceLevelBase` was `byte` to match the entity, and `InputNumber<T>`'s static constructor throws outright for `System.Byte` — "The type 'System.Byte' is not a supported numeric type". That escapes `BuildRenderTree` unhandled, which in Blazor takes the WHOLE page down, not one field. `/clusters/{id}/nodes/{nodeId}` and `.../nodes/new` have never rendered. Now `int` with the same `[Range(0, 255)]` and a cast on the way to the entity, so the stored type is unchanged. (Same failure mode as #504: an unhandled throw inside the render tree is a page-kill.) 2. **Save did nothing, silently.** `NodeId` was validated against `^[A-Za-z0-9_-]+$`, which forbids the colon — but every NodeId in this system is `host:port` (`ClusterRoleInfo` and `ConfigPublishCoordinator` derive it as `member.Address.Host:Port`, the seed writes `central-1:4053`, and `NodeDeploymentState.NodeId` is FK-bound to it). So every existing node failed validation, `OnValidSubmit` never ran, and the button was inert. Pattern now allows `:` and `.` (hostnames may be dotted). 3. **Added the missing `<ValidationSummary/>`.** The form had a `DataAnnotationsValidator` but nothing rendering its output, so a validation failure produced no feedback at all — which is precisely how (2) stayed invisible. This is the change that stops the next such defect being silent. Live-verified on docker-dev (both central nodes rebuilt, since :9200 round-robins the pair): page 500 → 200 on both routes, and a real edit now persists. |
||
|
|
2193d9f2e4 |
fix(config): refuse to store a Sql credential in a node config override (#499)
`ClusterNode.DriverConfigOverridesJson` is the third surface a Sql driver's config is persisted on, and the only one nothing gated. It is a map keyed by `DriverInstanceId` merged onto the cluster-level `DriverConfig`, so a literal `connectionString` pasted there leaks exactly as one pasted into the driver — the leak #498 closed for `DriverInstance.DriverConfig` and `Device.DeviceConfig`. Gated at the SAVE, not at the deploy — a deliberate departure from both options the issue offered: - `DraftSnapshot` carries no `ClusterNode` rows, and adding them would widen the snapshot and every builder of one for a single rule about a value that never enters the artifact. - More to the point, a deploy gate is the wrong instrument here. Node overrides are not in the artifact, so blocking a deploy would not stop the credential being stored — it is already in the database and replicated by then. Refusing the save is the only point where "refuse to store it" is literally true, which is #498's own framing: discarding a secret on read is not the same as refusing to store it. The check moves into a shared `SqlCredentialGuard` so the two enforcement points cannot drift; `DraftValidator` now calls it instead of its own private helper. Kept deliberately narrow — the `Sql` driver's `connectionString` only, and only for instance ids that ARE Sql drivers. The issue asked whether to generalise to credential-shaped keys across every driver type; not doing that, for the same reason #498 did not: a broader sweep would start refusing configs that are legitimate today for drivers which never made an indirect-credential guarantee, which is a regression rather than defence in depth. Widen per driver, as each gains its own contract. The error names the offending driver instance(s) and NEVER the value — it reaches the AdminUI and the audit trail. 14 new cases cover both halves, including the case variants (System.Text.Json binds `ConnectionString` to `connectionString`, so a case variant is the same key, not a bypass), non-Sql ids being ignored, and every blank/malformed/non-object shape. |