#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The gateway alarm feed names an alarm "Galaxy!<Area>.<tag>.<Attr>". The AdminUI Galaxy
picker authors attributeRef "<tag>.<Attr>". OnAlarmFeedTransition reverse-mapped only the
full reference, so a picker-authored native alarm never matched its condition and never
went active. Its ack also dialled the bare reference, which AcknowledgeAlarm refuses.
ResolveAlarmRawPath now matches the full reference, then SourceObjectReference, then the
full reference without its Provider!Area. prefix. A fallback match records the full
reference per RawPath, and AcknowledgeAsync dials it, so the gateway accepts the ack and the
#869 confirmation watch matches. Found and re-verified live in the #615 G6 gate on the
windev test Galaxy.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Hermle49 (iTNC 530 NC 340490 03 SP10) refuses the tool selector with code 24;
the driver correctly publishes BadNotSupported for every Tool/* leaf, so there
is no runtime type to check. The test required >0 Good leaves and failed there.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper)
and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked
a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a
priority-1 alarm read 250 and a priority-999 system event 1000.
It now uses AVEVA's default priority ranges, most urgent first:
AVEVA priority AVEVA severity bucket OPC UA Severity
1-250 1 Critical Critical 1000
251-500 2 High High 750
501-750 3 Medium Medium 500
751-999 4 Low Low 250
(history only) 0 not an alarm - 1
Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03
Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1,
400/500 severity 2, 600/700 severity 3, and every priority-999 System.* /
User.* row severity 0 with IsAlarm 0.
- Live and history now use the same number. GalaxyDriver passes the table's
exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket,
which NativeAlarmProjector re-mapped through its generic 200/500/700/900
ladder, so live and history disagreed even before the direction fix.
- History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy,
User.Write...) is not an alarm and reads Severity 1, below every alarm band.
For alarms AVEVA's 1-4 severity is still never the value: the live feed
carries only the priority, so it cannot use it, and history must agree.
- Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity
(lmxopcua#887)"; docs/AlarmTracking.md updated.
- Live re-run of the #801/#886 harness against vd03 HistorianGateway
ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886
run, the 9 others differ only in Severity (priority-700 alarm rows 750 ->
500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md
"#887 re-run", report aveva-gate-sdk2-887.json.gz.
Client-visible: every OPC UA client that ranks or filters Galaxy alarms by
Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has
no code that depends on the old values; its own mixed severity directions are
ScadaBridge#129.
Tests updated because they pinned the inverted table:
- Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/
500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps,
monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001)
- Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium)
- Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999
-> 250, 1 -> 1000; system events -> 1)
- OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 ->
500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4
severity)
New tests:
- Runtime.Tests NativeAlarmRestatementEndToEndTests
.Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real
feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests
pins on the history path)
- EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm
(5 rows, incl. the priority-999 alarm positive control)
- GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through
Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the
driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band
edges off by one; history ignoring priority; a missing AVEVA severity read
as 0.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A notifier folder read one event source, its NodeId identifier (a RawPath or an EquipmentId). AVEVA stores a
Galaxy object's A&E history under the object's tag_name (Source_Object), so AVEVA's own alarm and event
history reached no production folder. Its lower-case property keys were also missed, so every row read
Severity 1 with no ConditionName.
Sources. A folder's event history now reads its own source plus the Galaxy object of every native condition
that fires on it live: those parented under it and those WireAlarmNotifiers wired to it. Live and history use
the same membership. The object comes from the condition's Galaxy alarm reference, its raw tag's attributeRef,
up to the first '.':
- The composer reads it with the driver's own parser (GalaxyAttributeRef, shared with GalaxyDriver), only for
a GalaxyMxGateway tag with an alarm (RawTagPlan.NativeAlarmReference, part of plan equality).
- The applier binds it after materialising the condition (IOpcUaAddressSpaceSink.BindNativeAlarmHistory,
forwarded by the deferred sink). A rebuild or the condition's removal forgets it.
Each object is read with the #882 rule: its own events and <Object>.<Attribute> rows, never a prefix sibling.
Fan-out. historiangw's ReadEvents filter is a single predicate, so there is one request per source; the wire
contract is unchanged. EventSourceFanOut merges the reads as one source:
- order is (time, source position, arrival), reversed for a reverse read; ties are never re-sorted by EventId,
so the boundary skip stays stable;
- duplicates by EventId are dropped and the merge is cut to the cap;
- a truncated source bounds the page at the time it stopped.
Paging, continuation points (bound to the whole source set), the walked-back reverse read and the tie-cluster
over-fetch are unchanged. A folder with one source is read exactly as before.
ACL. Every source is read inside the folder's own HistoryRead, after AuthorizeHistoryRead (#826). A denied
folder reads nothing and fails closed.
Mapping (EventMapper, property names now case-insensitive):
- Severity: an AVEVA row's priority goes through GalaxyAlarmPriority, the table live Galaxy alarms use
(MxAccessSeverityMapper now delegates to it), so history matches live. Otherwise severity (OtOpcUa's own
rows, which AVEVA stores lower-cased), clamped. AVEVA's own 1-4 severity is ignored. The table ranks a
higher priority as more severe, which inverts AVEVA's convention: filed as #887.
- An AVEVA row whose source_conditionvariable names a native condition that fires on the folder takes that
condition's SourceNode and live ConditionName. Otherwise ConditionName is alarmname or the condition
variable's attribute.
- alarm_id/alarmid map to AlarmId.
Tests:
- GalaxyEquipmentEventHistoryWireTests (4, real SDK session, production Gateway backend, AVEVA-shaped fake
gateway): equipment EqA backed by objects Oven_007 + OvenDoor_07. Covers object and attribute events from
both objects, the prefix sibling excluded, cross-object and in-object ties, forward paging at 1-4 a page,
reverse whole and paged, SourceNode/ConditionName/Severity, the raw device folder, ACL deny with no backend
call plus a granted positive control, and a rebuild forgetting the bindings.
- EventSourceFanOutTests (8), EventMapper AVEVA cases (11), GalaxyAttributeRefTests (16), a composer test and
an applier ordering test.
- Mutation-checked, 17 mutants, all killed. Covered: parent-only membership, no scope, a case-sensitive
condition match, no condition rewrite, no truncation bound, EventId tie order, no sort, no cap, no stop at
the bound, unreversed source order, no dedupe, no '.' boundary, priority ignored, case-sensitive keys, no
applier bind, no deferred forward, and a composer that ignores the driver type. The forget-on-rematerialise
guard survives as belt-and-braces: the rebuild clear covers it.
- Live, read-only, no WinRM, vd03 HistorianGateway ea9f21c: equipment folder EQ-886-ZipsenLeft (objects
DevWinPlatform + Left_001). It read 0 events before and 92 now, equal to the unfiltered read's rows for both
objects. 1/7-event pages and reverse whole/5-event pages agree, and 73 rows resolve to their live condition.
diff_runs vs the #882 run: 221/226 identical. The 5 that differ are expected: DevWinPlatform Severity
1 -> 750/1000, and #881 capabilities.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.
LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.
OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.
Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
HistorianGateway answers a per-source ReadEvents (Source_Object = DevWinPlatform) with the
object's own events (SourceName DevWinPlatform) AND its attribute alarms, which it reports as
<Object>.<Attribute> (Source_ProcessVariable, e.g. DevWinPlatform.CPULoadAvg). The Gateway
backend's defensive client-side source filter compared SourceName for equality, so it dropped
the attribute alarms: 70 of the 72 DevWinPlatform events on vd03.
The filter (and the past-the-cap "more events" signal) now uses EventSourceMatch: the source
itself, or <source>.<anything> on the '.' boundary, ordinal. DevWinPlatform never matches
DevWinPlatform2 or DevWinPlatform2.X. This needs no wire change and still makes one request.
Each event keeps its own SourceName. SourceNode stays the condition its stored alarm id names,
which is null for AVEVA rows. The attribute events ride the notifier's own read, so the
per-folder HistoryRead verdict (#826) governs them: a denied folder answers
BadUserAccessDenied before any backend call. The SqlServer and QuestDB backends still match
exactly; they hold only OtOpcUa's own events.
Tests:
- GatewayAttributeEventSourceTests (16): the boundary theory, attribute-in/sibling-out through
the data source, the drain signal, and an exact attribute-named read.
- AttributeEventHistoryWireTests (2, over a real SDK session with the production Gateway
backend on an AVEVA-shaped deterministic gateway): object + attribute events with their own
SourceName, a prefix sibling excluded, paging, and the ACL-on deny with no backend call plus a
granted positive control.
- Mutation-checked: exact match fails both wire tests; dropping the '.' boundary fails the
wire sibling check and 6 unit tests.
- Live AVEVA harness re-run against vd03 HistorianGateway ea9f21c (read-only, no WinRM):
folder DevWinPlatform 2 -> 72 events (whole, 72 1-event pages, reverse); the new #882 check
passes; 221 of 225 shared cases are identical to the #801 SDK2 baseline, and the 4 that
differ are exactly the DevWinPlatform event cases. Recorded in aveva-history-801.md.
Follow-up #886: production folders name RawPaths/EquipmentIds, not Galaxy objects, plus the AVEVA
severity/condition property mapping.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Adds GatewayGalaxyStreamAttachedAckLiveTests (skip-gated on MXGW_ENDPOINT +
GALAXY_MXGW_API_KEY, like the other gateway live tests). Proves what the unit
suite cannot: the request flag reaches a real gateway and the sentinel comes back.
- live session advertises stream-events-attached-ack; GatewayGalaxySubscriber reports it
- raw stream: sentinel is the first message when requested (family Unspecified,
worker_sequence 0, live_after 0) and never sent when not requested (control,
with a data event as the positive control)
- real GalaxyDriver + EventPump + GatewayGalaxySubscriber behind a pass-through
recorder: exactly one sentinel, ack observed before the first SubscribeBulk,
pump StreamAttached completed, sentinel never dispatched nor counted as
received (galaxy.events.stream_attached=1, received == non-sentinel events),
no missing-ack warning within the production 1 s budget, and the static
attribute TestMachine_002.Tagname delivers its initial value
- control: a subscriber that opts out gets no sentinel and the pump never
reports one, while the #865 fallback still delivers
Run 2026-11-12 against windev 10.100.0.48:5120 (mxaccessgw 447070a5): 4/4.
Mutation checks, each caught: subscriber not requesting the ack (sentinel
count 0); driver skipping the ack wait (wire order became stream | subscribe |
ack, 2/2 runs, so the race is real on a live gateway); pump not intercepting
the sentinel (received=2 vs 1 non-sentinel).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
mxaccessgw#227 (Contracts/Client 0.4.0) adds an opt-in attach acknowledgement on
StreamEvents: a StreamAttached sentinel MxEvent sent first, only after the
stream's subscriber is registered on the session. This closes the #865 attach
race that waiting for "stream requested" only narrowed.
- Bump vendored MxGateway.Client/Contracts 0.3.0 -> 0.4.0 (nuget-packages/,
pulled from the Gitea feed; local-mxgw stays the mapped source).
- IGalaxySubscriber.SupportsStreamAttachedAck (default false, so fakes and older
seams keep the fallback); GatewayGalaxySubscriber reads it from the live
session's capabilities (stream-events-attached-ack) and passes
emitStreamAttached accordingly; TracedGalaxySubscriber forwards it.
- EventPump: records AttachAckExpected before the stream opens (published
before StreamRequested completes); intercepts ev.StreamAttached ahead of the
ReplayGap check - completes StreamAttached and continues: never dispatched,
never counted as received, never a resume cursor (worker_sequence 0). The
signal also completes when the loop ends so no waiter hangs. One pump = one
stream, so a reconnect's new pump has a fresh signal. New counter
galaxy.events.stream_attached.
- AwaitCurrentEventStreamAsync: with the capability, waits on StreamAttached
within the same StreamRequestWait budget (1 s); a missing ack logs a
rate-limited Warning and proceeds instead of hanging. Without the capability
the old StreamRequested wait is the fallback.
Tests (StreamAttachedAckTests, 6): ack-gated subscribe gets its initial value;
capability absent uses the fallback; missing ack times out with a warning; the
sentinel is never dispatched; a dead stream releases ack waiters; reconnect
gives each stream a fresh signal. With the ack wait skipped, 3 of them fail.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The rule fix itself landed in 1a08b4f7 (detail-0 failure rows route on
category); its test only exercised raw_detected_by = 3. Add per-source
coverage for every MxStatusSource value mxaccessgw's MapSource emits
(-1, 0..5, and an out-of-range value) across the failure categories, plus
the live-captured shape the old rule got wrong (OperationalError detected
by the responding automation object, mxaccessgw docs/AlarmProbeFindings.md)
and a RequestingLmx CommunicationError positive control. All 10 new cases
fail against the old 'detail 0 && raw_detected_by != 0 => comms' rule.
Comment in FromMxStatus now cites MapSource and says why NMX (2/3) is not
a transport signal. Item 1 (Warning/Pending) stays open pending a capture.
Co-Authored-By: Claude <noreply@anthropic.com>
Gate F (#761) against the VD03 gateway: Galaxy initialize (session open +
platform seed) took 4–5 s against Tier A's 5 s Initialize timeout, so 10 of 40
restarts failed, paid a 10 s retry and left a killed gateway worker.
DriverFactoryRegistry.Register takes optional capabilityDefaults per driver
type (GetCapabilityDefaults); DriverResilienceOptionsParser layers them over the
tier table and under the per-instance ResilienceConfig; the Host wires the
registry into DriverCapabilityInvokerFactory. Galaxy registers Initialize =
20 s (no retry, breaker 2), under the actor's 30 s pessimistic bound.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Every raw detected_by value names an MXAccess layer (requesting/responding
LMX, NMX, automation object); the gateway's own failures arrive as
ProtocolStatus. The 'non-zero source = transport failure' rule made a failure
the responding object detected a comms error. Item 1 of #872 (Warning/Pending
categories) stays open pending a captured row.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway fills Statuses on every data change (live OnDataChange, value-cache
replay and session snapshot all carry Quality too), and EventPump used the status
row whenever one was present, so Quality was never read: an off-scan, Bad or
Uncertain attribute with an OK status row was published Good. A failure status
row still wins; otherwise the quality byte grades the value (legacy parity:
quality >= 192 Good).
Live, read-only on VD03 (DEV): healthy ScanState and _TestArea attributes stay
Good (0x00000000) via quality 192; the stopped JoePlatform/JoeAppEngine ScanState
now publish BadCommunicationError (0x80050000) instead of generic Bad, with no
"unrecognised quality byte" warning.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway copies MXSTATUS_PROXY.detail verbatim, so a failure row's detail is
always an MxStatusDetail code. FromMxStatus routed any detail <= 0xFF through the
OPC DA quality table: MX_E_PlatformCommunicationError (2) on a stopped platform's
ScanState logged "Unrecognised MXAccess quality byte 0x02" and published generic
Bad (VD03 live capture), MX_E_InvalidObjectId (8) became BadNotConnected,
MX_E_Overflow (20) BadCommunicationError, and a detail in the Uncertain band
published Uncertain for a failure.
Every non-zero detail now maps per the gateway.md vocabulary (timeout,
communication, configuration, type, range, access, initialising), then by
category; the category-fallback warning logs once per (detail, category).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Adds an escalated-stream-fault test seam and a test: the live pump's fault
escalates (positive controls before and after), a superseded pump's late
fault after a reopen does not; the absence is asserted only once both
pumps' callbacks are known to have run (HasEnded). Verified to fail with
the filter disabled. The filter's comment now says the identity check does
the work and warns about a future session bump while Healthy.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
ReconnectSupervisor swallowed a transport failure reported while Replaying,
so a restarted event stream refused/ended a round trip after the replay
began still let the replay go Healthy over a dead stream (and the next
advise's re-report restarted at attempt 1 with no backoff). A failure
reported during Replaying is now remembered and turns that attempt's
success into a retry with backoff. ReplayAsync's synchronous dead-pump
throw yields to a teardown's cancellation.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- Start the ack confirmation with Task.Run + ConfigureAwait(false) so it never
depends on the ReceiveAsync handler's ActorTaskScheduler (the PostStop
abandon-and-revert report must run after the actor stopped).
- DriverInstanceActorAckConfirmationTests: a confirmation that faults after the
handler returned is reported; one pending at actor stop is reported; a
confirmed ack reports nothing (positive control).
- Deterministic tracker matching test (Raise/Clear/Retrigger/other alarm do not
confirm; case-insensitive match does).
- AdminUI min/max on the confirm-timeout field; Galaxy.md documents the
reconnect, UNACK_RTN-as-Clear and RPC-budget limits.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- ReplayAsync fails when its restarted pump's stream has already ended, so
the supervisor backs off and stays Degraded instead of going Healthy over
a dead stream (whose next advise re-report restarted at attempt 1 with no
backoff - a tight reconnect loop).
- ReconnectSupervisor.AttemptInProgress (reopen through replay); advises
wait for a stale pump's replacement only while an attempt is running, not
for a whole backoff (the state still reads Reopening/Replaying there).
- ReconnectSupervisor: _disposed is set under the state lock and re-checked
inside ReportTransportFailure, so a late report cannot start a recovery
loop that StopAsync already missed.
- EventPump.HasEnded is a flag set before StreamRequested is released, and
a stream that ends/faults on its first MoveNext is marked ended first.
- SubscriptionRegistry fast path: a miss now falls through to the locked
path (lookup + session + window check atomically) instead of a lock-free
re-lookup.
- Tests: replay over an immediately-ending stream fails; AttemptInProgress
across attempt/backoff; ReportTransportFailure after stop; the
reopen-window test uses a generous wait bound.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
mxaccessgw answers AcknowledgeAlarm OK both when the AckMsg write was
applied and when it was only sent (no OnWriteComplete; the reply then
carries a diagnostic). EvaluateReply treated both as success, so the H6
live gate saw a condition go Acknowledged while Galaxy never applied it.
- EvaluateReply returns Applied (no diagnostic) or Unconfirmed (diagnostic)
and logs the gateway diagnostic on every branch that carries one.
- GalaxyAckConfirmationTracker watches the alarm feed from before the RPC
and, for an unconfirmed reply, waits up to AlarmAck.ConfirmTimeoutMs
(default 10 s, 0 = old behaviour) for an Acknowledge/ActiveAcknowledged
transition; on timeout it refuses (BadTimeout + diagnostic).
- New optional IAlarmAcknowledgeConfirmation: DriverInstanceActor awaits it
after AcknowledgeAsync, off its mailbox and outside the resilience
pipeline; a failure is the existing #760 AlarmAckFailed revert.
- AdminUI Galaxy form carries the new knob; docs updated.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- StreamRequestWait 1 s (under Tier-A Read 2 s / Subscribe 5 s budgets) and
a stale pump is only waited on while the supervisor is reopening or
replaying (or a restart is underway); in a reconnect backoff the advise
proceeds at once. The no-stream log is a rate-limited Warning while
Healthy, Debug otherwise.
- A current-session pump whose loop has ended is not a stream: if the
supervisor already reports Healthy (its fault was swallowed while it was
recovering) the failure is re-reported to start a new cycle.
- Subscribe/Read no longer start the pump directly (only
AwaitCurrentEventStreamAsync does, honouring the replay restart flag);
the teardown refusal is an explicit ThrowIfRuntimeStopping.
- SubscriptionRegistry.ResolveOrPark fast path: the handle lookup and the
open-window check were not atomic, so a subscribe that registered the
handle and closed its window in between got its initial value dropped as
stale (found by a stress run: the first event of a bulk advise lost). It
re-looks-up before declaring stale. Deterministic test via a seam.
- Tests: first Read on a fresh driver, replay of a data subscription.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Round 1 replaced a stale-session pump from any advise path and disposed the
old one in the background; that could start a second stream while the old
one still held the gateway's single-subscriber slot, and a kept
current-session pump could be dead with no fault re-reported.
- EnsureEventPumpStarted reuses again; only ReplayAsync restarts the pump.
RestartEventPumpForReplay keeps a current-session pump only while its loop
is running (EventPump.HasEnded), and flags the restart so no advise path
starts a competing pump in the dispose gap.
- AwaitCurrentEventStreamAsync (bounded by StreamRequestWait) starts a pump
only when none exists, WAITS for the replay while the pump is stale or
restarting, waits for StreamRequested, and returns the session it verified.
SubscribeAsync (per #861 attempt), read-via-subscribe and the probe hook
issue and fence the advise under that session, so a reconnect after the
check is caught as a straddle and retried.
- Read: a deadline (not caller) cancel during the wait falls through to
per-ref results.
- Tests: reopen-window probe test now asserts the advise waits for the
replay's single new stream; first Subscribe/Read wait for the stream; the
fencing tests that advise in the window use a short wait bound; the
production-path seed test uses an empty galaxy (a real probe advise now
starts a stream against the fake endpoint).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- EnsureEventPumpStarted replaces a pump created for an older registry
session (the reopen -> replay window still held the dead session's pump,
so an advise there lost its initial value and the replay skipped it);
RestartEventPumpForReplay keeps a pump already on the current session.
- SubscribeAsync, read-via-subscribe and ReplayAsync also await the
bounded StreamRequested wait before advising, not just the probes.
- TryEnsureEventPumpStarted tolerates a teardown flipping _runtimeStopping
mid-check; the probe hook honours an already-cancelled seed token.
- StreamRequested is documented as narrowing, not closing, the attach race.
- Tests: reopen-window probe test, EventPump.StreamRequested tests, and the
FixRound1 fresh-pump assertion now waits on a positive control.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
When the data starts inside an interval (no start bound) and its first value is
Uncertain, the frozen 1.5.378.182 AverageAggregateCalculator integrated the
uncovered span as a ramp from 0 and divided TimeAverage by the whole interval:
GetRegionsInValueSet (ignoreBadData, sloped) overwrites the BadNoData start
region's status with UncertainDataSubNormal in its one branch without a not-Bad
guard. Live AggregateFilter therefore disagreed with HistoryRead and Part 13
§5.4.3.6/§5.4.3.8 ("No Start Bound: Calculate Partial Interval"); QP: Total
188.96 vs 163.96, TimeAverage 9.448 vs 10.931. SDK 2.0.1 stock does the same.
Owner-approved 2026-11-11.
- New app-owned CoveredTimeAverageAggregateCalculator subclasses the baseline
and recomputes only TimeAverage/Total, restoring the Bad status of a region
that starts at a Bad point (only the start bound can). Only such an interval's
value changes; status, timestamps, type and bits are the baseline's. Stepped
and TreatUncertainAsBad=true never reached the defect. CompatibilityAggregate-
Factory routes exactly those two IDs; copied SDK files untouched.
- Golden test: 0 fixture vectors change (every data set has a usable value at
-10 s), asserted. New sweep over late-start variants of every data set (cut
+5 s / +25 s, first non-Bad sample Uncertain, all directions/stepping/configs/
incremental): 150 / 142 of 384 change, each pinned to a baseline-derived
oracle (untouched baseline's value with that sample Good, its status/bits on
the variant itself) - never our calculator. Plus a hand-computed case.
- Live-vs-HistoryRead parity (TimeWeightedAggregator) forward + reverse, no
masks, with discrimination against the pre-#821 baseline; QualityMix now
compares QP's TimeAverage/Total with the live oracle on both SQL backends;
booted-runtime facts test expects 163.96 / 10.93.
- README recorded decision, ServerAggregateConfiguration remarks, oracle
remarks, docs/Historian.md and .claude/rules/historian.md updated.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway's StreamEvents with after_worker_sequence = 0 is a fresh stream
and never replays, and the event pump started only on the first
Read/Subscribe, so platform ScanState probes advised before then lost their
initial value (and a driver with no authored tags never got any host status).
PerPlatformProbeWatcher now awaits an ensure-event-stream hook before every
probe SubscribeBulk (seed, discover sync, reconnect ResubscribeStaleAsync).
The driver's hook starts the pump (refused while a teardown is in progress)
and waits, bounded, on the new EventPump.StreamRequested signal - completed
once the stream loop's first MoveNext has issued the StreamEvents RPC, or
when the loop ends - so the advise never precedes the stream request.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway's shared GalaxyHierarchyProjector ANDs template_chain_contains
entries, so the single request carrying both $WinPlatform and $AppEngine
matched no object and the probe watcher always seeded 0 platforms.
GatewayGalaxyPlatformSource now runs one paged sweep per template and
unions/dedupes by tag name. The tests use a fake gateway that applies the
projector's AND semantics (they fail on the old single request).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
HeidenhainSession.Leaf's `case Lsv2Tool t` switch expression mixed long, int and
double? arms, so C# unified the natural type to double? and Tool/Number (Int64),
Tool/Index and Tool/AxisCode (Int32) were published as Double. Every arm in that
switch (and in the alarm-list, axes and feature-acquire switches in the same file)
is now boxed to object explicitly so no numeric arm can widen another.
New HeidenhainLeafRuntimeTypeTests asserts value.GetType() for every catalog value
leaf against its declared DataType (scalar + array), plus PLC/DATA binding coercion
for Int16/Int32/Int64/Boolean. Verified red on the old code (exactly the three Tool
leaves) and green with the fix.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
TwinCATDriverProbe ran a first-phase TCP check against the AmsNetId's
first four octets on the AMS port (801/851). An AmsNetId is not an IP and
the AMS port is not a TCP port, so Test Connect timed out against every
real runtime (Z35474: dialled 5.118.56.93, an unrelated public host).
The probe now opens no socket of its own: it takes the driver's path,
AdsClient.Connect + ReadStateAsync through the local AMS router, bounded
by the probe budget (Task.Run + WaitAsync), and classifies failures as
no local AMS router / no route or target unreachable / timeout / other.
The degrade-to-green 'TCP reachability only' outcome is gone - with no
TCP check nothing was contacted, so a missing router is reported red.
Tests: the regression test listens on the AmsNetId-derived endpoint and
asserts no connection arrives (fails on the old probe); classification
and budget tests drive the handshake through an internal seam.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The frozen 1.5.378.182 StatusAggregateCalculator counts Uncertain regions as
Good under TreatUncertainAsBad=false, so live AggregateFilter PercentGood /
DurationGood disagreed with HistoryRead (Part 13 §5.4.3.31/§5.4.3.33, Mantis
0006166) whenever Uncertain data was present. Owner-approved 2026-11-11.
- New app-owned GoodOnlyStatusAggregateCalculator subclasses the baseline and
replaces only the PercentGood/DurationGood computation (Good regions only);
CompatibilityAggregateFactory routes exactly those two IDs to it. The copied
SDK files are untouched; the other 35 aggregates are byte-identical.
- Golden test: the 64 changed vectors (38 PercentGood + 26 DurationGood) are
exempted exactly — those whose baseline output differs from the same case's
baseline TreatUncertainAsBad=true twin — and pinned to that twin (baseline
evidence, not regenerated from the implementation); plus a full Good-only
pin over all 352 PercentGood/DurationGood vectors and a hand-computed case.
- Live-vs-history parity over Good/Uncertain/Bad mixes (no masks), with a
discrimination check against the pre-#809 baseline; the booted-runtime facts
test now expects 8000 ms / 40 %.
- SdkAggregateOracle: Run/RunLive = the registered factory; RunSdkAsIs = the
untouched baseline; its Part13GoodCalculator duplicate is removed.
- README (recorded decision), ServerAggregateConfiguration remarks,
docs/Historian.md and .claude/rules/historian.md updated.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Owner decision 2026-11-11 (Java parity): a genuinely empty observation on a
String/Reference or unauthored item is Good "" instead of BadNoCommunication.
Non-string items (numeric, bool, DateTime, arrays) keep BadNoCommunication -
the Agent supplied no value; BadTypeMismatch would wrongly blame the authored
type. The UNAVAILABLE sentinel is unchanged, and a structured observation with
no text stays BadNotSupported (structured check now precedes the empty check).
Parity matrix, quality-mapping section and drivers rule updated.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
With Reconnect.ReplayOnSessionLost=false a recreated gateway session carries none of
the old advises, so every pre-reconnect subscription went silently deaf: nodes kept
their last value as Good and health returned to Healthy (only a Warning log).
ReplayAsync now records the stranded subscriptions and publishes BadNoCommunication
(StatusCodeMap.BadNoCommunication, 0x80310000; value null — no driver value cache)
for every tag of each, straight to OnDataChange so LastSuccessfulRead is not stamped.
GetHealth reports Degraded naming the setting while any stranded subscription is
still registered; it clears on UnsubscribeAsync (the host's re-subscribe path) or
runtime teardown, and pruned ids never pin it. A subscribe after the reconnect is an
ordinary new-session subscription. With nothing else flowing, the comms-loss
watchdog re-initializes the driver after 90 s (a delayed replay).
Tests: Runtime/StrandedSubscriptionTests (6). Docs: drivers/Galaxy.md, which also
no longer claims the replay uses the gateway's ReplaySubscriptions RPC.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
BLOCKER: the reconnect replay chose work from the registry entries' sessions,
but ONE registry entry holds every probe handle and any probe publish on the
new session (a seed in the reopen→replay gap, or the straddle retry) re-stamps
it as current — the replay then skipped the probe watcher and the old
platforms stayed bound to handle 0 (host status frozen); a publish after the
snapshot made it re-subscribe everything (double advise, leaked handle).
ReplayAsync now excludes the probe entry from its snapshot and calls the new
PerPlatformProbeWatcher.ResubscribeStaleAsync on every reconnect, which
re-subscribes exactly the platforms whose ProbeHandle.Session predates the
current session. The replay-gap path keeps ResubscribeAsync (all platforms).
Also: ClearRegistry (teardown) starts a new registry session, so a late
PurgeParked from a teardown-orphaned call cannot reach the next runtime's
parked values; the read path's unused pump local is gone (call kept).
Tests go through the driver's reopen/replay: the probe old-session-number test
is rewritten that way, plus the seed-in-the-gap scenario (only P and Q are
re-subscribed, R keeps its new-session handle, all three resolve). Both checked
red with the probe replay removed / re-subscribing all platforms.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
B-1: the subscribe-once read's cleanup unsubscribes what the registry holds at
removal (the replay may have rebound it to new-session handles), not its
original bindings; nothing when the entry still holds dead old-session
handles. Found while testing it: reads were attached to the pump INSTANCE, so
a read across a reconnect's pump restart never saw the replayed value — reads
now listen on a driver-level ReadDataChange raised for whichever pump is live.
I-A: PerPlatformProbeWatcher records the registry session with each probe
handle. Publishing goes through the new fenced TryUpsert and binds only
current-session handles; removal/stop unsubscribe and purge only those; a
seed reply that straddled a reconnect records nothing and is re-issued (max 3).
I-B: PurgeParked takes the session captured BEFORE the unsubscribe RPC and is
a no-op under the park gate if the session changed.
I-C: ReopenAsync starts a new registry session before AND after the gateway
session swap; ReplayAsync does so only when no reopen ran (injected subscriber
/ tests) and replays only subscriptions still holding older-session handles,
so a subscribe issued after the swap is live and not double-advised.
P-1: ReplayAsync restarts the pump before any early return (no entries used to
leave the dead pump in place). P-2: ReplayOnSessionLost=false logs a Warning;
misleading comment about gateway-side replay fixed.
M-a: TryRebind returns BindOutcome; UnknownId releases the handles just
advised for a subscription removed mid-replay. M-b: the replay/re-snapshot
pass reads the session once and stops if it changes. M-c: parked entries drop
their MxEvent when they leave the parked set. M-d (retry a straddled read)
not done.
Tests (TestWait) for each, each checked red against a mutation of its fix.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
I-2: unclaimed parked events are trimmed by window sequence. Each window gets a
monotonically increasing sequence at Begin, each parked event is stamped with
the newest one, and on every End events stamped before the oldest open
window's sequence are dropped (amortised O(1) via a park-order queue). Under
concurrent reads the open count rarely hit 0, so trailing events used to pile
up to the bound and push genuine early values into overflow.
I-1 / #861: SubscriptionRegistry.StartNewSession() — called FIRST in
ReplayAsync on every reconnect — clears held events, invalidates the reverse
map (subscriptions kept) and bumps a session number. New-session events whose
number an old binding still held now park until the replay's per-subscription
Rebind promotes them, instead of resolving to the wrong tag. TryRegister /
TryRebind refuse a stale session atomically under the park gate: a
SubscribeAsync whose reply straddled a reconnect is re-issued on the new
session (max 3 attempts), a subscribe-once read returns BadCommunicationError,
ResubscribeAllAsync stops if the session changes again. Old-session handle
numbers are never unsubscribed (Remove reports whether the entry belongs to
the current session; the read's late-reply path checks too), and an old
session's pump can no longer resolve through the map (fast path checks the
session).
I-3 (interim): a completed UnsubscribeBulk purges events parked for its
handles (driver + probe watcher). Full fix needs a worker sequence on the
SubscribeBulk reply (mxaccessgw, optional) — documented.
M-1: a resolved handle with a stranded parked list promotes it and resolves
the live event (never parks it). M-2: ResolveOrPark returns the ready events
to replay first, one gate acquisition per event while anything is held.
M-3: SubscribeAsync/read dispose the window before the orphan-release RPC.
M-5: ResolveOrPark remarks document the single-dispatching-pump invariant.
Tests (TestWait): overlapping windows don't accumulate, purge, stranded list,
session fence + map invalidation, stale-session registration refused,
end-to-end replay with swapped handle numbers and event-before-reply,
subscribe and read straddling a reconnect, read deadline closes its window.
Each was checked red against a mutation of the fix it pins.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
1. ReadAsync (subscribe-once) now opens the early-event window around its
SubscribeBulk + registration; an initial value that overtook the reply was
dropped and the read returned BadTimeout.
2. Register/Rebind write the reverse map and promote parked events in ONE
critical section under the park gate, and ResolveOrPark resolves under that
gate whenever anything is held (lock-free fast path only when nothing is),
so a later live event can no longer overtake the parked initial value. A
resolved handle that still holds a parked list queues behind it.
3. Held events are fenced by a session epoch: each new EventPump calls
StartNewEpoch(), discarding parked AND promoted-but-unreplayed events; an
older pump can neither park nor replay. Item-handle reuse across a reconnect
can no longer put an old-session value on a new tag.
4. ResubscribeAllAsync opens one window per subscription, not across the whole
replay.
5. Promoted-but-unreplayed (ready) events count toward MaxParkedEvents.
6. Begin/End of a window run under the park gate, so N->0 discard and 0->1
open are atomic (no inherited leftovers).
Documented that ParkedEventsReady may run under _registryGate/_syncLock and
relies on the channel's AllowSynchronousContinuations=false.
Tests use TestWait (#858); each new test was checked red against a mutation
of the fix it pins.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
mxaccessgw gives no reply-before-event ordering: the worker completes the STA
command via a RunContinuationsAsynchronously TCS, so the reply is framed on a
thread-pool continuation while the STA already pumps the OnDataChange Advise
queued (drained/framed by a separate loop), and the reply (unary Invoke) and
the event (StreamEvents) are separate HTTP/2 streams. The driver then also
registers handles concurrently with the pump's dispatch loop. MXAccess's
initial value could therefore be dropped as "stale after unsubscribe",
leaving the node at its pre-subscribe value until the next change.
SubscriptionRegistry gains an early-event window: every SubscribeBulk call
site (SubscribeAsync, ResubscribeAllAsync, PerPlatformProbeWatcher) opens
BeginPendingSubscribe() before the RPC and closes it after registering.
Inside the window unknown-handle events are parked (bounded, 100k); the
Register/Rebind that binds a handle promotes them, and the EventPump replays
them on its single dispatch thread before any later event for that handle
(woken by a sentinel when no further event arrives). Closing the last window
discards unclaimed events, so the stale drop is unchanged outside it.
New counters galaxy.events.early_{parked,replayed,overflow}.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Under heavy parallel load (14 concurrent test processes + 14 CPU burners, with
DOTNET_ThreadPool_ForceMinWorkerThreads=1 as the reproducer) the Galaxy tests
with 1-3 s fixed waits failed 16/70 runs. Every failure was a background loop
started with Task.Run (alarm feed, DeployWatcher, EventPump, ReconnectSupervisor)
not being SCHEDULED within the ceiling - e.g. DeployWatcher's stream had not even
been opened after 2 s. No production race: the code under test was checked for
each (alarm feed dispatch is synchronous in-order, DeployWatcher/ReconnectSupervisor
state is lock- or loop-local, subscribe registers before returning).
- New shared TestWait (UntilAsync / ForAsync / HealthyAsync): 30 s presence
ceiling, failure reports elapsed ms + an observed-state snapshot (#856 shape;
GalaxyDriverFixRound1Tests.WaitUntilAsync now delegates to it).
- Converted the short waits in GatewayGalaxyAlarmFeedTests, DeployWatcherTests,
GalaxyDriverSubscribeTests, GalaxyDriverRawPathKeyingTests (its WaitForAsync
never threw on timeout), EventPumpStreamFaultTests, EventPumpReplayGapTests,
ReconnectSupervisorTests; FixRound2 InitBudget 2 s -> 10 s (the parked fetch
never completes, so any finite bound keeps the verdict).
- Absence by short sleep replaced with positive controls: DeployWatcher bootstrap
and same-deploy-time (follow with a real change, assert exactly that one raise -
verified red when suppression is removed), subscribe failed-tag / unsubscribed
handle (follow with a live handle's event), faulted pump (wait for its
onStreamFault instead of 100 ms).
- Fixed sleeps that raced scheduling: subscribe-once read tests wait for the
read's registration (TrackedSubscriptionCountForTests) instead of 50 ms;
supervisor Dispose test waits for reopen entry instead of 50 ms; the
already-Healthy WaitForHealthy test asserts synchronous completion instead of a
wall-clock bound. FakeSubscriber.Map is now a ConcurrentDictionary.
Loaded run (14 parallel x 5, 14 burners, ForceMinWorkerThreads=1):
before 16/70 failed runs; after 0/350 (70 + 210 + 70). Without the thread-pool
override: 0/70 before and after on this host. Serial: 472 passed, 8 skipped.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Found while load-verifying #856: ShutdownAsync_cancels_the_event_stream_and_releases_the_pump
timed out 7/700 under parallel load. The fake's StreamCancelled was set by a
CancellationToken registration scoped by `using` inside the async iterator.
On Cancel() the newer ReadAllAsync registration runs first and resumes the
iterator on a pool thread, whose `using` can dispose our registration while
Cancel() is still walking the callback list - so it never runs. Signal from
the iterator's finally (when the token is cancelled) instead, which also
proves the stream actually ended. 0/700 after.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
PerPlatformProbeWatcher records a platform's handle and publishes the probe
binding into the driver registry as one step under _syncLock, but
WatchedPlatforms read the handle map lock-free - so it could report a
platform one step ahead of the registry Upsert. A ScanState event raised in
that window was dispatched by the EventPump, missed ResolveSubscribers and
was dropped as "stale after unsubscribe", leaving the host status empty.
That is the #856 flake: A_fetch_completing_after_init_populates_host_statuses
waited for WatchedPlatforms, emitted ScanState, and timed out at 10 s on the
final Running wait. Reproduced 11/700 (28 parallel runners x 25 + 14 CPU
burners), every failure at that step with the binding present by the time of
diagnosis and hostStatuses=[] - i.e. the event was dropped. 0/1400 after.
WatchedPlatforms now reads under _syncLock (test seam only; the dispatch path
already checks the map after the registry, the safe order). New
PerPlatformProbeWatcherVisibilityTests spins a reader on another thread and
asserts the registry entry exists the moment the platform is visible
(old code: torn in 1691/2000 iterations). WaitUntilAsync gains a describe
overload; the #856 test's waits now report elapsed time and the observed
seed/binding/pump/host-status chain on timeout.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- AdminUI MTConnect driver form: "Comms-loss confirm (ms)" in the Reconnect section, always written
(0 = first refusal, negative = off is never dropped), case-insensitive load, unknown keys preserved,
advisory at >= 90000 ms (the watchdog fires first). Form output byte-pinned and parsed through
MTConnectDriver.ParseOptions on the driver side.
- Driver: a confirmed refused-connection outage now annotates every told CONDITION quality-only
BadNoCommunication (state/ack kept, once per outage, UNAVAILABLE-Bad skipped); the first delivery
afterwards re-diffs all subscribed conditions so unchanged ones get a quality-only Good.
- docker-dev/docker-compose.mtconnect-gate.yml: throwaway Agent in its adapter's network namespace so a
stop is a genuine ConnectionRefused (a plain stopped container is a DNS failure = ambiguous).
- Docs: MTConnect.md comms-loss section + live-gate recipe, docker-dev README, drivers.md rule.
Refs #852
I-1: Test Connect / browse configs may carry unsaved edits (the device modal merges
the stored DriverConfig with the typed device config). The server
(DriverInstanceIdentities.EffectiveOwnerAsync, used by AdminOperationsActor and
BrowserSessionService) honours the named owner only when every endpoint value
(new DriverCredentialRules.EndpointFields: Galaxy Endpoint, OpcUaClient
EndpointUrl/EndpointUrls/DiscoveryUrl, Heidenhain Host/Port) is one that driver
stores; otherwise the owner is null and its instance-named secrets are refused.
Every Test Connect / browse whose config carries an in-scope secret:/env: reference
is recorded (CredentialUseAudit: IAuditWriter event category CredentialUse + a
structured Information line: user, driver, endpoint hosts, outcome).
L-1: the UserCertificatePath rule is skipped only in an object that explicitly sets
AuthType to non-Certificate (string or ordinal); the deploy gate also checks the
runtime-merged driver+device config so the switch cannot be split from the path; the
form no longer persists the hidden field.
L-2: a ConfigDb fault in the browse check is a refusal; RawBrowseModal catches open
failures into its error message.
L-4: a relative UserCertificateDirectory resolves against AppContext.BaseDirectory.
Co-Authored-By: Claude <noreply@anthropic.com>
#835: inside one driver namespace, a secret:<ns>/<X>/... reference whose first
segment names ANOTHER existing same-type driver instance (id or name,
case-insensitive; another-instance match beats an own-name match, so renaming
one's driver after a victim's unlocks nothing) is refused at save
(DriverConfigSaveGate.ValidateAsync), deploy (CredentialReferenceOtherInstance,
Heidenhain included), Test Connect (TestDriverConnect.DriverInstanceId, ConfigDb
read off the mailbox) and live browse (BrowserSessionService, fail-closed without
a ConfigDb). One rule: DriverCredentialPolicy.DescribeOtherInstanceProblems +
DriverInstanceIdentities. Shared names and the driver's own id stay valid; env:
is not instance-scoped. Running drivers are unchanged (warn-only window: the
deploy gate and the upgrade preflight / /raw banner list them).
#836: OpcUaClient UserCertificatePath is a relative path inside
Drivers:OpcUaClient:UserCertificateDirectory (default
<LocalAppData>/OtOpcUa/pki/user-certificates). Syntactic rule (CredentialFilePaths,
a DriverCredentialPolicy path field) at every #815 seam; at load time
ResolveSecretRefsAsync joins, canonicalises and requires lexical AND
link-resolved containment before the PFX password is resolved, and
LoadCertificate refuses an unresolved path. A running driver's pre-#836 absolute
path keeps loading with a rate-limited warning (LegacyCredentialReferenceTracker.ReportPath).
Co-Authored-By: Claude <noreply@anthropic.com>