Commit Graph

15 Commits

Author SHA1 Message Date
Joseph Doherty f8785cfa2c Merge branch 'worktree-agent-a71443b71c4c01c13' into heidenhain-pylsv2-parity
# Conflicts:
#	.claude/rules/drivers.md
#	docs/drivers/Heidenhain.md
#	tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Heidenhain.Tests/HeidenhainPyLsv2ParityTests.cs
2026-11-12 23:57:06 -05:00
Joseph Doherty 3055646688 Merge branch 'worktree-agent-ab2193d7e99435def' into heidenhain-pylsv2-parity
# Conflicts:
#	.claude/rules/drivers.md
#	docs/drivers/Heidenhain.md
2026-11-12 23:56:31 -05:00
Joseph Doherty 4cee05c2f8 feat(heidenhain): R_RI runtime-info parity with pyLSV2 — state names, refusal codes, timer/unit docs
Compared every R_RI decoder we use (22-28, 30-34, 51) byte-for-byte with pyLSV2 (MIT,
97a3d691) and ran the captured iTNC 530 replies through pyLSV2 itself: no decode
disagreement, so no published value changes.

- Additive read-only String leaves Status/ExecutionStateName, Status/ProgramStateName and
  Tool/AxisName (pyLSV2 ExecState / PgmState / decode_tool_info names; out-of-table code =
  "Unknown"). They ride the raw leaf's feature, so no extra wire read; raw Int32 leaves unchanged.
- Refusals: 52/72 -> BadOutOfRange, 58 -> BadTimeout, 56 -> BadInvalidState, 57 (outside the
  alarm walk) -> BadNoData. IsStable and the 57-only alarm-walk end are unchanged.
  Lsv2RefusalCodes names every code (pyLSV2 LSV2StatusCode) in exception/log/probe text.
- Timers 30-34 documented as uint32be seconds (lifetime counters) per pyLSV2, hardware-unproven;
  TimersEnabled stays false. Axis/tool units: none on the wire, none assumed.
- Lsv2ReadOnlyPolicy untouched (pinned by a test); R_RI 20/21 left out.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-12 23:55:34 -05:00
Joseph Doherty 50933d57fc feat(heidenhain): PLC/DATA parity with pyLSV2 — FF bits, INPUT/OUTPUT_DWORD, PLCDEBUG write-up
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
  return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
  02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
  int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
  conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
  raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
  an owner decision; Lsv2ReadOnlyPolicy is unchanged.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-12 23:53:16 -05:00
Joseph Doherty ba9015fac8 feat(heidenhain): classify the control family from R_VR; DATA gated to iTNC 530 (per pyLSV2)
- HeidenhainControlFamily + HeidenhainControlFamilies.Classify (Contracts): one authority, ported from
  pyLSV2 (MIT) dat_cls.py VersionInfo.control (strip spaces, case-insensitive prefix, ITNC530 first).
  Families: ITnc530, Tnc (640/620/320/128), Tnc7, Lathe (CNC PILOT 640 / MANUALplus 620), MillPlus,
  LegacyTnc (426/430, not a pyLSV2 class), Unknown.
- New additive read-only leaf Controller/Family (String, Identity feature, derived from the same R_VR
  reply: no extra request). Lsv2Versions.Family is computed, so record equality and the #831
  identity-change rediscovery signal are unchanged. Probe message + /hosts diagnostics (<host>.family).
- DATA gate now goes through SupportsDataPath(family) (pyLSV2 client.py read_data_path is iTNC-only):
  non-iTNC and Unknown => Capabilities/DataLogin Unsupported, DATA login never sent. Replaces the
  "model contains itnc" substring check (same result on the real iTNC530 controls).
- No per-family selector pre-gates: pyLSV2's TNC 640 observations (27/28/51/30-34 unknown telegram,
  25/26 need DNC) are already handled by the reply-driven refusal/suppression path; tests pin it.
- Lsv2ReadOnlyPolicy, HeidenhainTagWritable and the no-IWritable rule are untouched.
- Simulator: per-family ControlProfiles (strings from the pyLSV2 README tables / protocol.rst), both
  R_VR field counts, 124-byte R_PR; HeidenhainControlFamilyTests (classification, gates, decoding,
  wire log inside the read-only set, refused selectors asked once).
- docs/drivers/Heidenhain.md: Control families matrix (iTNC 530 hardware-proven; the rest per pyLSV2,
  hardware-unproven) + open questions (C_CC buffer size, encrypted passwords, R_RI 20/21).

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-12 23:52:06 -05:00
Joseph Doherty 8e97fc94fd fix(heidenhain): Tool/Number, Tool/Index, Tool/AxisCode publish their declared integer types (#867)
HeidenhainSession.Leaf's `case Lsv2Tool t` switch expression mixed long, int and
double? arms, so C# unified the natural type to double? and Tool/Number (Int64),
Tool/Index and Tool/AxisCode (Int32) were published as Double. Every arm in that
switch (and in the alarm-list, axes and feature-acquire switches in the same file)
is now boxed to object explicitly so no numeric arm can widen another.

New HeidenhainLeafRuntimeTypeTests asserts value.GetType() for every catalog value
leaf against its declared DataType (scalar + array), plus PLC/DATA binding coercion
for Int16/Int32/Int64/Boolean. Verified red on the old code (exactly the three Tool
leaves) and green with the fix.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:20:33 -05:00
Joseph Doherty ddc1f29e3a feat(heidenhain): Part 9 condition class from alarm class/group, ALARM: selectors in the browse picker, unclaimed alarms counted + logged (#839)
- Core: optional AlarmEventArgs.ConditionClass (AlarmConditionClass Base/Process/Maintenance/System/Safety)
  carried by NativeAlarmProjector on AlarmConditionSnapshot and written to ConditionClassId/Name by
  OtOpcUaNodeManager (kept across class-less events, carried across a #641 rebuild).
- Heidenhain: HeidenhainAlarmClasses — HEIDENHAIN DNC-interface class/group names (corroborated by the
  captured iTNC 530 record); class 5 => Safety, group 1/2 => Process, 4/5 => System, else Base.
- DiscoverAsync offers AlarmConditions/ selector leaves (IsAlarm Boolean); browse-commit seeds the alarm object.
- Alarms no selector claims: otopcua.driver.alarms.unmatched counter, /hosts diagnostics, rate-limited Warning.

Refs #839
2026-11-11 03:41:14 -05:00
Joseph Doherty e9064dbdf4 Merge fix/815-credential-ref-scoping
# Conflicts:
#	.claude/rules/drivers.md
#	docs/drivers/Heidenhain.md
2026-11-11 02:08:24 -05:00
Joseph Doherty 2b0eed1a8f feat(heidenhain): controller alarms as native Part 9 conditions; rediscovery on identity change (#831)
- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
  ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
  An ALARM: address and the cross-driver alarm object only work together — the factory
  refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
  fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
  driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
  Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
  FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
  deterministic display order, told-record on the driver instance, recorded only while a
  handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
  Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
  the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
  tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
  "Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)

Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
2026-11-11 01:37:41 -05:00
Joseph Doherty a224fd6391 fix(security): scope operator-authored credential references per driver (#815)
A Designer could point a Galaxy / OpcUaClient endpoint at a host they control,
set a credential field to any reference the node can resolve
(env:ConnectionStrings__ConfigDb, env:ServerHistorian__ApiKey, secret:<any>,
Galaxy file:<any path>) and click Test Connect / live browse; the node resolved
the value and sent it to that host.

One shared rule in Core.Abstractions (CredentialReferences +
DriverCredentialPolicy) generalises the #803 Heidenhain namespace:
- Galaxy: secret:galaxy/... | secret:otopcua/galaxy/... | env:OTOPCUA_GALAXY_... |
  legacy env:GALAXY_MXGW_...; file: refused; dev:/literal API key unchanged.
- OpcUaClient: secret:opcuaclient/... | env:OTOPCUA_OPCUACLIENT_...; literals unchanged.
- Heidenhain adopts the shared parser/resolver (namespace unchanged).
Enforced at the AdminUI save path (DriverConfigSaveGate), the deploy gate
(CredentialReferenceDeployChecks, code CredentialReferenceOutOfScope), Test
Connect (AdminOperationsActor, before any probe), live browse
(BrowserSessionService, before any browser) and again at resolve time in every
driver/browser (fail closed, before any store/env read).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:28:58 -05:00
Joseph Doherty 5bbe1e3c7a fix(heidenhain): resolve the probe's secret resolver lazily — eager resolution crash-looped central nodes at boot (#803)
v2-ci / unit-tests (push) Successful in 1h9m7s
The Test-Connect probe set is resolved inside the AdminOperations Akka starter; resolving
ISecretResolver there walks AddZbSecrets -> IAuditWriter -> ActorAuditWriter, whose ctor needs
AuditWriterActorKey (registered later in the same builder). Found by the docker-dev live gate.
Regression test: resolving the probe set never resolves ISecretResolver (fails before the fix).
Also: TagRowProblem doc comment re-attached; Heidenhain credential help text names the
secret:heidenhain/ and env:OTOPCUA_HEIDENHAIN_ namespaces.
2026-11-11 00:27:37 -05:00
Joseph Doherty f7a3588b24 fix(heidenhain): namespaced credentials, optional-role credential isolation, loop robustness (#803 review)
- Credential exfiltration (review 2): password references are scoped to
  secret:heidenhain/<name> and env:OTOPCUA_HEIDENHAIN_<NAME> only. Enforced by
  HeidenhainOptionsParser.TryParseCredentialReference (parser, probe, deploy gate) AND again at
  resolve time in HeidenhainCredentials (fail closed without consulting the store or the
  environment), so Test Connect can no longer send env:ConnectionStrings__ConfigDb or another
  subsystem's secret to an arbitrary Host. The probe also refuses an unsendable password.
- Optional-role credentials (review 6): an unresolvable/NUL/non-Latin-1/>247-byte DNC or DATA
  credential never sends a login and never fails the session; the reads needing that role are
  BadConfigurationError (capability ConfigurationError) and INSPECT telemetry continues. A
  policy refusal inside AcquireAsync is per-tag, not a session teardown.
- Start after DisposeAsync is a no-op (review 3); initial subscription push and Publish are
  ordered under one lock (review 4); JSON-null sections are normalised and the acquisition loop
  catches every fault (review 5); backoff resets only after a session published a poll batch,
  with clamped delays (review 7).

Tests: HeidenhainReviewFixTests + namespace/normalisation tests in HeidenhainConfigTests;
each was confirmed red against the reverted fix.
2026-11-10 23:49:48 -05:00
Joseph Doherty 8fb03d6a72 docs(heidenhain): driver page, README/probe index rows, drivers rule note (#803)
docs/drivers/Heidenhain.md: read-only boundary + allowlist table, transport, config,
credential references, address grammar (fixed catalog, PLC element/byte-count rules,
DATA types incl. FF Boolean), quality table, lifecycle/health/comms loss, probe, tests,
hardware-gated items and deliberate exclusions.

Also: InitializeAsync clears surviving subscription handles (the actor re-subscribes
after every successful init, so a kept handle would double-publish).
2026-11-10 23:23:25 -05:00
Joseph Doherty 2b45694f91 feat(heidenhain): read-only, credential and endpoint deploy gates + TagConfig inspector (#803)
- HeidenhainDeployChecks (wired into DraftValidator): HeidenhainTagWritable refuses a
  ReadWrite access level on any Heidenhain tag, so no node is ever advertised writable;
  HeidenhainCredentialPersisted refuses a literal password in DriverConfig/DeviceConfig
  (only blank / secret: / env: references; the value is never echoed);
  HeidenhainConfigInvalid for out-of-range settings or a tagged device without an endpoint.
- EquipmentTagConfigInspector maps Heidenhain to HeidenhainTagDefinitionFactory.Inspect.
- Driver validates only devices that carry tags (an unconfigured default Device1 no longer
  faults the driver).
2026-11-10 23:10:36 -05:00
Joseph Doherty d50ee809e3 feat(heidenhain): native read-only LSV2 driver + in-process simulator (#803)
Native LSV2 TCP transport (default port 19000; no Java/Python/vendor SDK), ported from
the ignitionoee v0.20.3 reference driver:

- Lsv2ReadOnlyPolicy: payload-aware outbound allowlist (A_LG INSPECT/DNC/DATA, R_VR, R_PR,
  R_RI 22-28/30-34/51, bounded R_MB, R_DP), applied in Lsv2Codec.Frame before any byte is
  written; no public raw-command API.
- Lsv2Client: serialized transactions, one monotonic deadline per transaction, EOF/oversize/
  unexpected/trickle close the client; Close never waits on the gate.
- Lsv2Data / HeidenhainBindingCodec: reference decoders, R_PR byte-capacity + element-index
  rules, next-area cap, DATA Boolean 00/01/FF, strict non-truncating coercion.
- HeidenhainSession: per-batch wire cache, refusal suppression, provisional DNC denial retry,
  alarm cursor (57 = end, overflow = BadOutOfRange), capability strings.
- HeidenhainDeviceRuntime: one loop per control, generation-guarded publication, all-node
  BadNoCommunication on comms loss, bounded exponential reconnect.
- HeidenhainDriver: cached ReadAsync, push subscriptions deduped on (value,status), static
  catalog discovery (no connect), host status, diagnostics, skipped-tag report. No IWritable.
- Probe (INSPECT login + version) and factory registered in DriverFactoryBootstrap (probe on
  admin nodes too); DriverTypeNames.Heidenhain.

Tests: 159 unit tests against an in-process LSV2 simulator incl. the Java fixtures' captured
iTNC 530 replies as golden vectors; env-gated LiveIntegration category for real hardware.
2026-11-10 23:08:30 -05:00