Commit Graph

9 Commits

Author SHA1 Message Date
Joseph Doherty fe2b0614c8 test(abcip): deterministic transport-switch probe tests
The libplctag-path positive control asserted 'timed out', but libplctag's internal
timeout equals the probe timeout and races the probe's own cancellation; under CPU
load it surfaces as 'ErrorTimeout' instead. Accept either libplctag stall outcome
(native never produces either: it fails at once with 'Connection lost').

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 23:51:11 -04:00
Joseph Doherty 7105ef3eb5 Merge #574/#576/#577/#584: AB forms preserve unknown keys + write factory ms keys, /raw device-name + prerender fixes, CLI read prints Bad status, docs dot-form
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 23:03:48 -04:00
Joseph Doherty be421a4cb0 fix(abcip): native browse paging/pacing/template lease (#572); differential equal-refusal + budget isolation (#575)
#572: listing continues at max(instance in page)+1 (no ascending-order assumption, no-progress guard kept);
browsePageDelayMs (default 5 ms) paces pages; DiscoverAsync reads templates through one batch reader
(IAbCipTemplateReaderFactory.CreateBatch) holding one lease.
#575: differential harness reports a same-status template refusal as an equal refusal; offline test pins the
open-attempt budget without relying on the abort ending the phase.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 22:59:42 -04:00
Joseph Doherty e588443ced fix(abcip,adminui): ParseEnum device wording + libplctag probe assertion (#574); AB forms preserve unknown keys + MaxConcurrentReads (#576); probe off for new AbCip driver (#577); docs T4:0.DN (#584)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 22:53:04 -04:00
Joseph Doherty b75e013d0a feat(abcip): final review I1 — node-level Drivers:AbCip:DefaultTransport
The old AdminUI cannot author the per-driver transport key (#576), so the
'pin before upgrading' recipe had no working path. A node-level appsetting
(env Drivers__AbCip__DefaultTransport) now supplies the default for AbCip
drivers with no key: explicit key > node default > compiled Native. Bound
and validated unconditionally (bad value fails host start); the driver
factory and the Test Connect probe both read it so they agree. AbCip.md
upgrade recipe rewritten around the key; Configuration.md documents it.
Also documents first-wins for AllowPacking/probe and host-alias throttles
(final review M6) and moves the status-bit note out of AbCip.md (M5).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 21:34:48 -04:00
Joseph Doherty 1806af54f0 fix(ab): Task 22 review r1 — release-note timing and AbLegacy regressions, probe E2E on both transports
- I1: the upgrade restart itself moves every no-key AbCip/AbLegacy driver to Native (every process
  start constructs drivers, incl. boot-from-cache). Docs + CLAUDE.md now say so and tell operators
  to set "transport": "Libplctag" BEFORE upgrading (older builds ignore the unknown key).
- I2: AbLegacy release note leads with the status-bit write refusal (T4:0.DN, C5:0.CU, R6:0.EN, ...)
  on defaulted SLC/MicroLogix drivers and the fallback. The real client status is
  BadCommunicationError, not BadNotSupported (the driver's write catch-all maps the runtime's
  AbTransportException like any transport failure, as #571 does for PLC-5), with handle eviction
  and Degraded health; pinned by a driver-level test (no 0xAA write on the wire, with a positive
  control). ST string byte order stated as unverified. Also corrects the docs' "T4:0/DN" examples:
  the driver's address grammar is "T4:0.DN" ("/DN" is a malformed address).
- I3: DriverProbeHandshakeE2eTests' two AbCip probe tests are a [Theory] over Native and
  Libplctag. Run against ab_server controllogix: all 4 rows pass with identical exact messages.
- M1: documented (docs + resolver XML doc): the AdminUI merges only the probed device, so a
  mixed-family defaulted AbLegacy driver can probe Native while running Libplctag.
- M2: factory ParseEnum rejects undefined integer strings ("7") via Enum.IsDefined (both drivers).
- M3: AbCip driver-level bad value reads "AB CIP config in '<id>' has unknown Transport ..."; the
  named constant is gone (tagName: null now means driver-level).
- M4: the explicit-Native limited-family Warning is once per instance, not per (re)init.
- Nit: EffectiveTransport docs note that injected factories bypass it.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 21:06:40 -04:00
Joseph Doherty ed0881d672 feat(ab): native managed transport is the default for AbCip and AbLegacy; libplctag remains as fallback
Task 22 (spec section 8 P5), with the controller rulings that exclude PLC-5 and LogixPccc.

- Transport is nullable on both option records; null (key absent) means "use the default" and is
  never serialized. Factory DTO parse: absent -> null; a bad value still fails via ParseEnum.
- One resolver per driver (AbCipTransportResolver / AbLegacyTransportResolver), used by the driver
  constructor, the Test Connect probe and (through the driver) the CLI.
  AbCip: null -> Native. AbLegacy: null -> Native unless any device is Plc5 or LogixPccc, then the
  whole driver resolves to Libplctag. Explicit values always win; explicit Native with a
  Plc5/LogixPccc device logs one Warning at init.
- Init log shows configured vs effective, e.g. transport=Native (default).
- AdminUI forms: "Default (...)" / "Native (managed)" / "libplctag (fallback)". Default omits the
  key on save (reverses Task 19's explicit re-emit, which would have pinned every edited driver).
- CLIs: --transport default|native|libplctag, default "default" via the resolver, so
  --plc-type Plc5 with no --transport runs libplctag.
- Tests pinned to Libplctag where a default-path runtime was created: found by instrumenting the
  native factories with the current xUnit test name (one unit test, AbLegacyReinitConfigAdoption;
  plus the two fixture-gated AbCip probe E2E tests whose exact messages were proven on libplctag).
  TransportMatrix and the differential harness already pass explicit transports.
- Switch/resolver/CLI/form tests are falsified by mutating the resolver (default -> Libplctag,
  exclusion removed, AbLegacy default -> Libplctag): each mutation turns them red.
- Replaces the inline role-name literal in AbCipDriverFactoryExtensions' ParseEnum call with a named
  constant; RoleAuthorityGuardTests was already red on the base commit for that line.
- Docs: AbCip.md / AbLegacy.md default + release note; CLAUDE.md AB section.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-07 20:49:33 -04:00
Joseph Doherty cff57d25c5 test(abcip): Task 15 nullable warning fix 2026-10-07 17:13:53 -04:00
Joseph Doherty 45f6e1793f feat(abcip): Transport option selects native or libplctag across driver, probe and CLI 2026-10-07 17:13:37 -04:00