2cf7c1d2
11 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
2331f7ed14 |
feat(sql): opt-in writes — allowWrites + per-tag writable, single-row parameterised UPDATE (lmxopcua#753)
v2-ci / unit-tests (push) Waiting to run
allowWrites is no longer inert: SqlDriver implements IWritable, default off. - Gates (outermost first): node Writable + WriteOperate (server), driver allowWrites, the tag's own TagConfig "writable": true (strict JSON boolean; anything else refuses the tag, and the deploy gate says why), and a model that names exactly one row — KeyValue, or WideRow by where-pair. topByTimestamp and Query are BadNotWritable. - SqlWritePlanner: the only statement a write can become is UPDATE <table> SET <value col> = @v WHERE <key col> = @k, built from the catalog-gate-canonical identifiers (dialect-quoted) with value and key bound; value-before-key marker order so positional ODBC binds correctly. No authored write SQL, INSERT, UPSERT or procedure. - Executed in a transaction that commits only when exactly one row was touched: 0 rows -> BadNoData (never inserts), >1 -> rolled back, BadConfigurationError, unknown count -> rolled back, BadNotSupported. Bounded by operationTimeout; provider errors -> BadCommunicationError; health untouched. - Discovery advertises Operate only where a write could succeed. - AdminUI: driver form's Allow writes switch is live; tag editor gains a per-tag write switch; model validates writable strictly (parity corpus). - Factory no longer warns "allowWrites ignored"; it logs whether writes are on. - Tests: SqlWriteTests (planner SQL/bind order/injection/coercion, every gate, readback, absent key, two-row rollback, gate-rejected tag, discovery); MySqlReadTests write legs against InnoDB (keyed row only, two-row rollback, server-side grant refusal, default-off). Seed adds a setpoints table and the one UPDATE grant. (lmxopcua#753) Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
0702b31029 |
fix(alarms): refuse a keyed native ack with no Galaxy identity synchronously, from a cached key set (lmxopcua#765)
v2-ci / unit-tests (push) Waiting to run
Item 3 of #765. A keyed (API-key) session whose key had no Galaxy ack identity got Good and then a revert, because whether the key has an identity lives in the Secrets store, which must not be read under the SDK lock. GalaxyAckIdentityDirectory (Driver.Galaxy) keeps a node-wide set of the key ids that have a galaxy-ack-user secret. It lists this node's Secrets store (metadata only, nothing decrypted) and is read lock-free. GalaxyDriver.GetAcknowledgeRefusal (IAlarmAcknowledgePreflight, published through NativeAlarmAckPreflightView as in #760) now refuses a keyed session whose key the directory reports Absent, when the driver has no fallback ack account. A refusal also asks for a refresh. Fails open: before the first refresh, once the snapshot is older than StaleAfter, and from a signalled identity-secret change until the next refresh, the lookup answers Unknown and the ack takes the old Good-then-revert path. Refresh: GalaxyAckIdentityRefreshService runs on driver nodes, every Drivers:Galaxy:AckIdentityCache:RefreshIntervalSeconds (default 30; StaleAfterSeconds 0 = three intervals; validated at start). It also refreshes early on secret changes. The Secrets library has no change event, so SecretsRegistration decorates ISecretCacheInvalidator, which is called by AdminUI /api-keys, /admin/secrets and the replication appliers. API-key changes need no event: a revoked key is already denied before the pre-check. Tests: Galaxy.Tests GalaxyAckIdentityDirectoryTests (16) and Host.Tests GalaxyAckIdentityCacheWiringTests (9). Seven separate mutations each turn at least one test red: pre-check ignores the directory, factory drops it, no invalidator decoration, no staleness check, no change-pending check, no refresh on refusal, loop never wakes early. Docs: Galaxy.md, AlarmTracking.md, Configuration.md, .claude/rules/alarms.md. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
f54922f94c |
fix(alarms): revert a native ack that reaches no driver; refuse native acks while the host is Stale (lmxopcua#765)
Residuals of #760: 1. An ack routed to a disabled / not-yet-spawned driver, or to a stubbed child (driver does not run on this node, or its factory rejected the config), was dropped and left the condition Acknowledged. DriverHostActor now reverts it through the same NativeAlarmProjector.TryRevertAcknowledge path as a refused ack. 2. A native ack arriving while the host is Stale was dropped before the projector recorded it, so it could never be reverted. Stale now marks the whole NativeAlarmAckPreflightView unavailable (SetHostUnavailable), so the node manager refuses every native ack synchronously; BecomeSteady clears it. 3. (keyed sessions without a Galaxy identity) is not addressed. Tests: DriverHostActorNativeAlarmTests' client-ack test and the FOCAS respawn theory now start the host's own driver (AckingAlarmDriver; a factory building a real FocasDriver per spawn over per-instance fake CNCs, with a real config-change respawn) - both fail against the fix in their old shape. New: ack to a disabled driver reverts, ack to a stubbed driver reverts, a Stale host refuses through the pre-check view - all three fail with the fix mutated out. Runtime.Tests 943/0/3. Docs: AlarmTracking.md, .claude/rules/alarms.md. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
7f29a75edb |
feat(mqtt): read Sparkplug B array metrics as 1-D OPC UA arrays (lmxopcua#754)
v2-ci / unit-tests (push) Has been cancelled
R06:M-5 made Sparkplug *Array leaves unbindable because the ingestor refused them. The ingestor now decodes the packed bytes_value of all 13 array types (new SparkplugArrayCodec: LE fixed widths, int64-ms DateTime, uint32-count + MSB-first BooleanArray, NUL-terminated UTF-8 StringArray; golden vectors are the spec's examples, reproduced byte-for-byte by SparkplugNet 1.3.10) and publishes a typed 1-D array through the scalar coercion, all-or-nothing. Shape uses the fleet's one array model: the tag's platform isArray/arrayLength keys (ValueRank=1, ArrayDimensions=[arrayLength] or [0] = variable length). The driver reads them with TagConfigIntent's exact semantics and never rejects on them, so composer, driver, authoring model and deploy inspector agree (MqttArrayShapeParityTests). Shape mismatch (array metric on a scalar tag, or the reverse) is BadTypeMismatch - a String tag no longer gets the packed buffer as base64; a malformed body or a length differing from a declared arrayLength is BadDecodingError (MTConnect #627 verdict). Template/DataSet members of an array type take the same path. Arrays stay read-only (encoder refuses them; MQTT is not in DriverArrayWriteSupport). Browser: array leaves are bindable again and state isArray in AddressFields; the commit mapper writes "isArray": true (no arrayLength). Discovery reports IsArray/ArrayDim. Docs: Mqtt.md "Array metrics", design table, drivers rule. Tests: codec (golden + malformed), ingest through the real codec + Dispatch (the project's MiniBroker never forwards a PUBLISH, so there is no in-process broker harness), browse, discovery, commit mapper, parity corpus. Mutating the fix back out fails 18 MQTT + 9 AdminUI tests. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
5db01053e8 |
docs(redundancy): stop claiming RedundancySupport/ServerUriArray are exposed; record why #717 is blocked (lmxopcua#717)
v2-ci / unit-tests (push) Waiting to run
Bounded, docs-only part of #717. The standard non-transparent metadata itself is NOT implemented here: the owner-selected contract is Warm with an explicit degraded standby (and None standalone), today's Secondary serves Good data at ServiceLevel 240, and the design/spec/plan for that standby behaviour is still pending on the issue - advertising Warm now would misdescribe the server. - docs/Redundancy.md: the "deferred pending an SDK object-type upgrade" claim was wrong; the pinned SDK 1.5.378.106 can build the graph (CreateMainNodeManagerFactory + AddBehaviourToPredefinedNode). Records what is and is not advertised (i=3709 SDK default, no i=11314) and the blocker. - .claude/rules/cluster-topology.md: said each node exposes RedundancySupport and ServerUriArray; it does not. - docs/OpcUaServer.md: same false claim about the SDK exposing them. Interop gates A4/A5b stay unmet; no product code changed. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
8e8d4cdf13 |
fix(alarms): surface a refused native alarm ack synchronously, revert one that fails later (lmxopcua#760)
The native-ack path is fire-and-forget after the Part 9 Acknowledge returns, so a Galaxy ack refused for lack of a credential (#749), or rejected by MXAccess, left the client with Good and the condition showing Acknowledged while Galaxy was never acked. Both options from the issue, layered: 1. Synchronous refusal for what the driver can decide without I/O. New optional IAlarmAcknowledgePreflight (Core.Abstractions); GalaxyDriver refuses an anonymous session when the driver has no AlarmAck fallback account. DriverHostActor publishes a condition NodeId -> owning-driver snapshot into NativeAlarmAckPreflightView (lock-free, volatile); the node manager's new NativeAlarmAckPreflight seam, consulted after the authz and Primary gates, returns BadUserAccessDenied with the reason - nothing routed, applied or reported. A keyed session is not pre-checked (its identity lives in the Secrets store, which must not be read under the SDK lock). 2. Revert for everything else. RouteAlarmAck carries the condition NodeId; DriverInstanceActor replies AlarmAckFailed on a refusal, a backend failure, a driver without an alarm source, or an ack dropped while connecting / reconnecting. DriverHostActor re-projects the condition unacknowledged via NativeAlarmProjector.TryRevertAcknowledge, but only while the local ack is still pending - any driver transition projected since then wins. A disabled or unspawned driver is not reverted (unchanged). GatewayGalaxyAlarmAcknowledger now throws DriverOperationRefusedException on a non-zero native hresult (wrong password, no ack permission) instead of only warning, so that case reverts too; as a refusal it neither retries nor trips the breaker. Tests (each fails with its fix mutated out): projector revert/supersede, DriverHostActor refused + failed ack -> unacked AlarmStateUpdate (successful ack control), preflight view snapshot, node-manager preflight unit test, over-the-wire ConditionMethodEventTests (BadUserAccessDenied, no route, no event; positive control), Galaxy preflight + hresult refusal. Docs: Galaxy.md, AlarmTracking.md, ScriptedAlarms.md, .claude/rules/alarms.md. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV |
||
|
|
acfb4fbaca |
fix(redundancy): a failed OPC UA endpoint drops ServiceLevel to 0 and steps the Primary down (lmxopcua#762)
v2-ci / unit-tests (push) Has been cancelled
IOpcUaEndpointState (review-remediation lane C3) recorded whether the SDK started, but only the health check read it: a fused node whose endpoint failed (port 4840 taken, ...) still advertised 250/240 and stayed driver Primary, so the Primary-gated data plane ran on a node no client could reach while the reachable peer refused writes as Secondary. - Move IOpcUaEndpointState/OpcUaEndpointState/OpcUaEndpointStatus from Host to Commons.OpcUa so the Runtime can consume it. - ServiceLevelCalculator: new NodeHealthInputs.EndpointListening (default true). false -> 0, ahead of every other input including the +10 Primary bonus. - OpcUaPublishActor: takes the endpoint state, feeds EndpointListening (Failed only; NotStarted / Stopped are boot/shutdown windows) on the DB-backed and DB-less paths, and the legacy role-only seam returns 0 for a failed endpoint too. - New OpcUaEndpointStepDownActor (one per driver node): a Primary (ClusterActiveNode.SelfIsActive, the election's own primitive) with a Failed endpoint gracefully Leaves its mesh - the manual failover mechanism - so the peer becomes the oldest Up driver member, hosts the singletons and is Primary. The election itself is not bent. Guarded on a peer having recently reported its own endpoint listening (EndpointReport on the new opcua-endpoint-state DPS topic), so a pair with both endpoints failed does not bounce the role and restart nodes forever, and a lone node never shuts itself down. - Runtime now references ZB.MOM.WW.Health.Akka (ClusterActiveNode). - Docs: Redundancy.md tier table + new "Endpoint start failure: Primary step-down" section; cluster-topology rule; HealthEndpoints / OpcUaEndpointHealthCheck comments (F-C1 landed). Tests: ServiceLevelCalculatorTests (+5), OpcUaPublishActorEndpointStateTests (7: DB-less, DB-backed, legacy seam, NotStarted/Stopped do not demote, a later failure demotes on the next tick), OpcUaEndpointStepDownActorTests (3, real two-node mesh: holds while the peer is not listening then leaves and the peer becomes Primary; failed Secondary and healthy Primary never leave). Each was mutation-checked: removing the calculator/legacy guard, the Leave, the peer-listening guard or the Primary guard fails the corresponding tests. |
||
|
|
cf62007678 |
fix(arrays): Modbus row honours the FC16/FC03 protocol ceilings, the RMW read cap and the address-space end
Review r0 of Integration-W3: - I1: the effective FC16 cap is min(configured maxRegistersPerWrite, 123). The driver trusts a larger configured cap and sends an over-ceiling FC16 (past 127 registers its byte-count byte wraps), which every conformant device refuses, so such an array is never advertised writable. - I2: a BitInRegister[] write reads its span first in one unchunked FC03, so it is also bounded by min(configured maxRegistersPerRead, 125) (absent/0 = 125). - m2: every span (registers and coils) must end at or before address 65535. - m1: the String-node wording says it converts only when the text parses, which the server cannot promise (DateTime never converts). - m4: the parity device now enforces FC01/02 2000, FC03/04 125 (or a smaller device read limit), FC15 1968, FC16 123, FC23 121/125, the FC15/FC16 byte-count field (exception 03) and the address-space end (exception 02). Tests: parity rows for each ceiling/cap/span boundary against the real write path, and Core.Abstractions row tests. The configured-cap test that asserted a cap of 200 lifts the ceiling now asserts the opposite. Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT |
||
|
|
5533de6281 |
feat(arrays): Modbus String[]/BitInRegister[] array writes reachable; table follows the resolver
The Modbus lane (#741 U3) gave the driver String[] and BitInRegister[] holding-register array encoders, and moved address resolution to ModbusTagAddressResolution (keys first, a bit region coerced to Bool, strict key reads), but DriverArrayWriteSupport still listed both array shapes read-only (follow-up F1), so a client write was BadNotWritable before it reached the driver. Modbus row now mirrors the driver end to end: - Keys shape only (region + address both present). A string-only addressString tag is resolved by the driver with its own family through a parser Core.Abstractions cannot reference, so it stays read-only (pinned: the conservative direction). - Strict reads as the resolver: address an integer 0-65535; a present region / dataType / byteOrder / stringByteOrder string must name a member. - Coils: any dataType (coerced to Bool), <= 1968 coils (FC15). - HoldingRegisters (FC16, never Bool): numeric, String ((stringLength+1)/2 registers, stringLength >= 1), BitInRegister (1 register, bitIndex 0-15, span ending <= 65535), all within maxRegistersPerWrite. FC23 is opt-in and never changes the answer. - Elements convert (ScadaBridge int[] -> Int16 stays writable); only a String / DateTime node over a numeric or bit element is left out, since such an element never converts. Tests: the parity test's PendingF1 exemption and its guard are gone; the parity matrix is now region x element type x node type against the real WriteAsync with a spec-conformant device (FC15 > 1968 refused), plus shape edges at every cap boundary (numeric, String, BitInRegister, coil), strict key reads, FC23 on/off, string-only, the ScadaBridge int[] shape and U3 wire bytes. Core.Abstractions row tests and a composer test (String[] and BitInRegister[] writable; over-cap, no-stringLength and string-only read-only). Docs: table XML doc, Uns.md, modbus-addressing.md, drivers/Modbus.md, data-plane rules. Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT |
||
|
|
44ea6595e5 |
feat(arrays): advertise AbCip/AbLegacy/TwinCAT array writes in DriverArrayWriteSupport
The Wave-2 lanes gave AbCip, AbLegacy and TwinCAT real whole-array write encoders (review 07 U10/U9), but the capability table still listed all three as scalar-only, so every array node materialised read-only and a client write was BadNotWritable before it reached the driver. Rows added, each listing only what WriteAsync encodes end to end: - AbCip: SInt/USInt/Int/UInt/DInt/UDInt/Real/Dt/LInt/ULInt/LReal, declared length, not a safetyTag. BOOL/STRING/Structure arrays stay read-only. - AbLegacy: Int/AnalogInt on N/B/A, Long on L, Float on F (file-width match), plain <file><n>:<word> address, <= 256 elements; not /bit, .sub, indirect, S:/I:/O:, nor native PLC-5. - TwinCAT: every codec element type, declared length; not a BOOL bit-in-word path. Elements convert in all three encoders, so the rows never key on an exact node DataType (ScadaBridge int[] -> Int16 stays writable); they leave out only node types whose elements never convert (DateTime/String over numeric, Boolean on AbLegacy, STRING under DateTime on TwinCAT: culture-dependent). Tests: driver-level parity for each driver (every element type x node type plus shape cases, against the real write path), the AbLegacy parity tests un-skipped, Core.Abstractions row tests, a composer test (three drivers writable, refused shapes read-only), and the existing AbCip negative cases moved to a BOOL array. Docs: Uns.md table, per-driver docs, data-plane rules. Refs #737 #738 #739 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT |
||
|
|
8c6067b62e |
docs: move subsystem gotchas out of CLAUDE.md into path-scoped .claude/rules