Cause: the client-side PerEndpointConnectTimeout (3 s), not opc-plc. The
validate:null case is the first test the assembly runs, so it pays the
cold-process cost of the first Basic256Sha256 connect: loading the fresh
throwaway certificate, validating the server's, and the asymmetric handshake.
In the G2 full-solution run that local work used up the budget. The opc-plc
log at 13:13:50-53Z shows the discovery channel closing at 50.709, then nothing
from the client for 3 s, then OpenSecureChannel answered at 53.775 and the
client closing the channel 48 ms later. The SDK reports a wait cancelled by
that budget as BadRequestInterrupted. opc-plc auto-accepted the certificate
(--aa, "Trusting certificate ... command line option") with no reject and no
store round-trip.
- Driver: a per-endpoint budget expiry now surfaces as TimeoutException naming
PerEndpointConnectTimeout instead of BadRequestInterrupted or a bare
TaskCanceledException. There is no behaviour change. Unit test added
against a silent TCP listener.
- Test: the ServerHostNameValidationTests secure options use a 15 s budget,
the same as the browser integration tests' 10 s. Connect latency is not
what these tests check.
- docs/drivers/OpcUaClient.md: documents what the budget covers.
c569f806 passed the bare "driver" literal to WarmRoleAuthority.OldestUpMember
at OpcUaPublishActor.cs:1875-1876, which RoleAuthorityGuardTests forbids outside
RoleParser. Same value; found by the #615 G2 full-suite run. Cluster.Tests
255/255, Runtime Warm tests 23/23.
G9 ran on an isolated 2-node pair (otopcua-g9, 003c7f89, Mode unset as
deployed) with otopcua-cli as the owner-approved client: A1-A3, A5, A7, A8
(graceful, ~11 s gap), B2 (docker kill, failover <1 s, ~2 s gap, 0 Bad,
survivor 250 at +44 s) and B3 (no failback) pass; A4/A5b unmet under Unset,
met under Warm (#717). G8 (CTT) waived by the owner for GA; G5 is the only
open exit criterion.
The run found the CLI printing every array as System.String[] (ServerArray
unreadable); ValueFormatter now renders [a, b] / hex for read, subscribe and
historyread, with tests. Runbook A4/A5b text updated for the #717 modes.
Evidence: docs/plans/evidence/2026-11-13-615-g9/RESULTS.md.
Bump ZB.MOM.WW.HistorianGateway.Client + Contracts 1.0.0 -> 1.1.0 (historiangw#135,
release 6365f34). GatewayErrorReasons now reads Client 1.1.0's typed
HistorianGatewayException.StatusCode / ErrorReason / ErrorDomain (constants from
HistorianGatewayErrorReasons) instead of parsing grpc-status-details-bin itself; the
direct Grpc.StatusProto pin and reference are dropped (the client brings it). The
published client maps every RpcException to a HistorianGatewayException, so the
trailer fallback is not needed. Behaviour unchanged: FailedPrecondition +
AGGREGATE_NOT_SUPPORTED_FOR_TAG (domain historian_gateway.v1) ->
BadAggregateNotSupported, everything else keeps its handling.
Adds GatewayErrorReasonsTests (typed-property-only exceptions, so they fail against
the old trailer implementation); wire tests and docs/Historian.md updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Two defects on the crash-failover path, found by the T13 live gate on an isolated docker pair:
1. When auto-down removed the unreachable Primary (~15 s after the survivor promoted), the
snapshot's Primary left the unreachable set, so (3') failed and the survivor demoted to
Standby (BadOutOfService, ServiceLevel 50) for ~15 s, until its own singleton published
after the hand-over retries. A Primary that is Down, or that this node saw removed, now
counts as gone (WarmRoleAuthority.SnapshotPrimaryGone). A member that is merely
Leaving/Exiting, or that this node never saw, is not.
2. The verdict read Cluster.State / SelfMember (Akka's ClusterReadView, a separate subscriber
to the same events), which can lag the event being handled. Live, the survivor stayed
Standby 4.3 s after its own UnreachableMember event (promotion waited for the next health
tick). The Warm verdict now uses a membership view built from this actor's own
member/reachability subscription, falling back to the read view only before the first event.
Tests: WarmRoleAuthorityTests.A_snapshot_Primary_that_auto_down_removed_is_still_gone_and_the_survivor_stays_Active,
OpcUaPublishActorWarmTests.The_crash_survivor_promotes_on_its_own_unreachable_event_and_stays_Active_through_the_removal
(synthetic events the read view never sees). Mutations: read-view-only verdict and the removed
arm switched off each fail the actor test. Runtime.Tests 1058 passed, 3 skipped.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A planned stop of the Primary took ~30 s on QA: WebApplication stops the web
server before Akka.Hosting's service, and Kestrel's graceful drain waited the
whole ShutdownTimeout for the peer's open LocalDb sync stream (the library's
LocalDbSyncService only observes the call token, which fires at the END of the
drain). Only then did CoordinatedShutdown run, so the stopping node held the
Primary role and the peer sat at ServiceLevel 240 for the whole window.
- GracefulClusterLeaveService (IHostedLifecycleService): StoppingAsync runs
before any hosted service's StopAsync; it raises ApplicationStopping, then
runs and awaits CoordinatedShutdown with ClrExitReason (not Cluster.Leave,
whose ClusterLeavingReason makes Akka.Hosting set ExitCode -1). The cluster
is left while Kestrel is still up.
- ShutdownStreamCancellationInterceptor (innermost on the shared gRPC
pipeline): every streaming call gets a context whose token is linked with
ApplicationStopping; streams arriving once stopping are refused Unavailable.
Host-side mitigation until LocalDb 0.3.8 is published and pinned
(scadaproj 3ddb083, scadaproj#57); it also covers the mesh streams.
Test GracefulStopWithOpenSyncStreamTests (real WebApplication + Kestrel h2c +
MapZbLocalDbSync + single-node Akka cluster + real peer initiator, 8 s drain
budget): stop 895 ms, cluster left at 892 ms, drain began at 894 ms. Positive
control without the fix: stop 8863 ms, cluster left at 8841 ms after the drain
began at 0 ms. Mutations: no CoordinatedShutdown in StoppingAsync -> order
assertion fails (drain at 1 ms, removed at 893 ms); interceptor passes the
original context -> stop 8006 ms, fails.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A picker-form native alarm (attributeRef tag.Attr) only learns the provider-qualified reference
Galaxy!<Area>.tag.Attr from the alarm feed. After a host restart the condition can be restored from
LocalDb before the feed's first snapshot reached the new driver, and an ack in that window dialled the
bare tag.Attr, which the gateway's AcknowledgeAlarm refuses.
The feed now exposes InitialSnapshotCompleted (set on snapshot_complete, after every snapshot entry has
been raised). AcknowledgeAsync resolves the reference through ResolveAlarmAckReferenceAsync: when a
picker-form tag has learned nothing yet and the feed is running, it waits for that snapshot (2 s, and the
caller's token) and dials the reference the snapshot names, so the area always comes from the feed and a
re-areaed object acks under its current area. No reference is guessed: if the snapshot does not name the
alarm, or does not arrive in time, the authored reference is dialled as before and refused visibly.
Chosen over the alternatives in the issue: a GR-browse area lookup can be stale against the runtime
area and is not loaded for authored tags, and a gateway-side tag.Attr resolution needs a cross-repo
deploy and would resolve from the same monitor cache the snapshot already carries.
Tests: 5 driver cases + 1 feed case (fail with the call site / sentinel reverted), and a skip-gated live
gate GalaxyPickerAckBeforeSnapshotLiveTests, run against windev's TEST Galaxy (TestMachine_015.TestAlarm003):
an ack issued before the snapshot dials Galaxy!TestArea.TestMachine_015.TestAlarm003 and is confirmed; with
the call site reverted it fails with the gateway's InvalidRequest refusal.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The #815 warn-only compatibility window is over. A running Galaxy driver
(InitializeAsync, every gateway ReopenAsync, the ack fallback password) and a
running OpcUaClient driver (session open) now refuse an out-of-namespace
credential reference with the same CredentialReferenceException that save,
deploy (CredentialReferenceOutOfScope), Test Connect and browse already raise,
before any store / environment / file read and before any endpoint is dialled.
The one existing scope check (CredentialReferences.Parse/ResolveAsync) is now
the only path; nothing new was added.
Removed:
- LegacyCredentialReferenceTracker (Core.Abstractions), its rate-limited WARN
and the credential-compat:<field> diagnostics entry.
- The per-driver Legacy* resolve methods and every `legacy` parameter
(GalaxySecretRef, GalaxyAckCredentialResolver, OpcUaUserIdentityFactory,
OpcUaUserCertificatePaths, OpcUaClientSecretResolution).
- IDriverDiagnostics on GalaxyDriver / OpcUaClientDriver (it only carried the
tracker's entries).
- The tracker also kept a pre-#836 absolute UserCertificatePath loading on a
running OpcUaClient driver; that is refused now too.
Preflight / banner decision: KEPT, as a hard error. The Running source
(driver-health credential-compat entries) and CredentialReferenceBannerModel
are gone with the tracker, but the ConfigDb scan still tells an operator
something no other surface does: a Deployed finding is now a driver that is
not connecting, a Draft finding is a deploy the gate will refuse - named
before anyone deploys, e.g. after restoring an old ConfigDb backup or
importing a pre-#815 config. It also carries the #835 cross-instance and
#836/#850 path checks. CredentialReferencePreflightService now logs one Error
per finding (was Warning) with no warn-only wording, and the /raw banner is
alert-danger.
DEV and QA ConfigDbs hold no Galaxy/OpcUaClient driver (checked 2026-11-13);
no production install exists.
Tests: GalaxyDriverLegacyCredentialTests replaced by
GalaxyDriverCredentialScopeTests; new OpcUaClientDriverCredentialScopeTests;
tracker tests in OpcUaClientSecretResolutionTests /
OpcUaClientUserCertificatePathTests deleted; AdminUI preflight tests drop the
Running/banner-model cases and assert Error level. Against the old code the
new refusal tests fail (Galaxy 5/6, OpcUaClient 4/5; the two positive controls
pass on both).
docs/security.md: the migration table now says running drivers refuse; the
warn-only section is replaced by "The compatibility window is over".
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Owner decision 2026-11-13 on #872 item 1. StatusCodeMap.FromMxStatus now maps a
Pending or Warning row to Uncertain (0x40000000) for any detail, ahead of the
detail vocabulary, keeping the once-per-(detail, category) warning. MXAccess sets
success = -1 on Pending (accepted, in progress); neither category is a failure.
Detail 8001 (automation-object ConfigurationError, write rejected for type
conversion, live-captured on windev 2026-11-13) maps to BadTypeMismatch. 8018
stays BadUserAccessDenied via its SecurityError category, now pinned by a test.
Data change: the value is published Uncertain. Write reply: the result is
Uncertain, never Good, so the server (which commits only Good) reports the write
not committed and reverts the node; a later MXAccess commit arrives as a data
change. Host status is unchanged (probe decode treats Uncertain and Bad alike,
quality < 192 -> Unknown); no alarm path calls the map.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Root cause: DeploymentDriftProbe (a singleton shared by every circuit) cached its verdict until
the ConfigEdit audit watermark (MAX(EditedAtUtc), COUNT(*)) moved, assuming every configuration
write appends a ConfigEdit row. Only deployments and driver restart/reconnect do; the AdminUI
editors (RawTreeService, UnsTreeService, ScriptEdit, cluster/node/ACL pages) write the config
tables directly. So after a draft change the page kept showing the cached "In sync" until
something unrelated moved the watermark.
- DeploymentDriftProbe: the watermark cache is gone; every verdict comes from a composition that
started after the caller asked. Compositions stay serialised behind the gate, and callers queued
behind one share a verdict only when that composition started after they arrived (start
sequence number) for the same sealed hash, so sharing is exact, never stale.
- Deployments page: the drift check runs in OnAfterRenderAsync (interactive render only, so a
visit costs one composition, not two with prerender); the first render shows a neutral
"Checking for changes..." chip, never a verdict; a failed check shows "Drift check failed" and
logs a warning instead of crashing the page. A deploy re-runs the check.
- Tests: probe tests for an un-audited draft change (real ConfigComposer over InMemory), fresh
composition per call, and queued callers not reusing an older composition; bUnit page tests that
a second page load after a direct draft change shows "Configuration drift" and that the first
render shows "Checking" until the comparison answers. All fail against the previous code.
DeploymentDriftProbeSqlServerTests is removed: it pinned the SQL translation of the watermark
query, which no longer exists.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Closing a tab with the script editor open ended the circuit; MonacoEditor.DisposeAsync then
called MonacoBlazor.dispose through SafeInvokeAsync, which caught only JSDisconnectedException,
so the TaskCanceledException from the torn-down circuit escaped and was logged at [ERR].
DisposeAsync now treats JSDisconnectedException, OperationCanceledException (incl.
TaskCanceledException) and ObjectDisposedException as the expected gone-circuit outcome and logs
them at Debug; a real JSException from a live page is still logged (Warning); the
DotNetObjectReference is released in a finally. MonacoEditor is the only component in the repo
that uses JS interop, so there is nothing else to align.
bUnit tests: dispose throwing each of the three gone-circuit exceptions neither escapes nor logs
above Debug (with a positive control that the failing call ran), and a JSException still warns.
They fail against the previous DisposeAsync.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Review of e113faf5 found three gaps in the alarm-feed reverse map:
- A tag hand-authored as Galaxy!<Area>.tag.Attr stopped resolving once Galaxy moved the object to
another area: the feed's full reference named the new area and none of the fallbacks looked at the
authored provider form. Provider-form attributeRefs are now also indexed by their area-free
tag.Attr, and the ack dials the reference the feed now uses.
- A reference composed with an empty area (Galaxy!tag.Attr, the gateway's ComposeFullReference when
the area is blank) with the subtag provider's object-only source reference stripped "tag." and
missed. The part after the '!' is now also tried.
- Resolution ran after the subscription gate, so a transition seen with no handle registered taught
nothing for the ack. It now resolves first; fan-out is still gated.
A picker tag and a provider-form tag for the same alarm resolve deterministically and log a warning.
New tests cover re-area for both forms, subtag shapes, H6-style dotted refs, unmatched/malformed
refs, the collision, pre-subscription learning, and the #869 confirmation of a picker-form ack;
reverted-code runs fail them.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A node declared numeric whose AVEVA tag is discrete (or string) is not refused up front by #897, so its native
TimeAverage / Total still reach AVEVA, which refuses them. A HistorianGateway at or after historiangw#135
(a220ec0) answers that FailedPrecondition with a google.rpc.ErrorInfo (reason AGGREGATE_NOT_SUPPORTED_FOR_TAG,
domain historian_gateway.v1) in grpc-status-details-bin. The Gateway backend's native processed read now maps
exactly that to HistoryAggregateNotSupportedException (BadAggregateNotSupported for the node) without recording
a health failure or treating it as transport. Any other FailedPrecondition and every Internal (an older gateway's
answer for the same case) keep today's handling.
Detection lives in one place, GatewayErrorReasons. The HistorianGateway.Client pin stays 1.0.0 (1.1.0 is not on
the feed): 1.0.0 keeps the gateway's RpcException, trailers included, as the InnerException of the
HistorianGatewayException it throws, so the reason is read with Grpc.StatusProto 2.76.0 (added via central
package management; nuget.org; same version as Grpc.Core.Api; depends on Google.Api.CommonProtos 2.16.0, which
accepts Google.Protobuf 3.34.1). With Client 1.1.0, ReasonOf becomes
`(ex as HistorianGatewayException)?.ErrorReason` and the StatusProto reference can go.
Tests:
- GatewayAggregateNotSupportedWireTests: in-process gRPC gateway sending the real status + ErrorInfo shape
(copied from historiangw HistorianRpcFaults.ToRpcException), read through the PUBLISHED Client 1.0.0 via the
production adapter: TimeAverage / Total -> HistoryAggregateNotSupportedException, 0 health failures; controls
(Internal; FailedPrecondition without ErrorInfo; other reason; other domain; the reason on Internal) are
rethrown, not IOException, and counted; positive control served.
- DiscreteTagTimeWeightedWireTests: over a real SDK session, a Double / Int32 node on the discrete tag ->
BadAggregateNotSupported with 0 failures; the older gateway's Internal answer keeps its status and counts.
- AvevaGatewayAggregateRefusalLiveGateTests: opt-in read-only live gate (OTOPCUA_AVEVA_GATE_900=true).
Mutations (catch removed; status ignored; domain ignored; reason ignored; inner-exception walk removed) each
fail at least one test. Release build 0 warnings; Historian.Gateway.Tests 601/607 (6 skipped), OpcUaServer
IntegrationTests 323/361 (38 skipped).
Live, read-only: private HistorianGateway container from a220ec0 (API-key auth disabled, live writes off,
removed after) against wonder-sql-vd03: Double and Int32 nodes on SysPulse, TimeAverage and Total ->
BadAggregateNotSupported, health failures unchanged (0); SysTimeSec TimeAverage Good (2 rows); SysPulse Average
served. Gateway traffic was ReadAggregate / ReadRaw / GetTagMetadata only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via
historianTagname re-typed/re-described it on every add and host start.
- TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly):
HistoryRead from an existing historian tag that OtOpcUa never provisions and never
records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags
hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the
RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid.
AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the
runtime parse.
- ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly
(Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not
sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start.
- Default for an explicit historianTagname stays OWNED: overrides pin owned history
across renames, a read-only default would silently stop provisioning + recording.
#898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized
Float/Double/Byte/SByte tags were never provisioned. New shared
HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16
(lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips
Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject).
UPGRADE: the first host start after this provisions (upserts) every existing historized
Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set
ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
libplctag 2.6.0 cannot parse RTC/HSC/... names; tag creation failed with
PLCTAG_ERR_BAD_PARAM, which the status translation reported as BadConnection:
evicted handle, degraded health, counted toward marking a healthy device down.
The libplctag runtime now refuses function-file addresses before creating a
native tag (Unsupported -> BadNotSupported, health untouched), matching native.
Docs: function files are unsupported on both transports, not "unverified".
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
TimeAverage / Total on a Boolean node over the Gateway backend (AVEVA discrete tag, live
SysPulse) went to the gateway since native TimeAverage/Total became default-on (#694). AVEVA
refuses both modes at StartQuery; the gateway reports that only as Internal /
HistorianServerOperationException (the same answer as a historian storage fault), so the
node answered BadHistoryOperationUnsupported and the read counted as a backend failure.
HistoryRead-Processed now checks the node's scalar DataType before calling any backend and
answers BadAggregateNotSupported (Part 11 6.5.4: "If the Aggregate is not valid for the Node
then the StatusCode shall be Bad_AggregateNotSupported"). Nothing is sent, nothing is counted.
- Shared, every backend: HistoryAggregateDataTypes (Core.Abstractions) applies Part 13
5.4.2.3 Table 50: the numeric-only aggregates (Average, TimeAverage(2), Total(2), Min/Max,
ActualTime, Range, Delta, DeltaBounds, Interpolative, stddev/variance) on a String or
DateTime node are refused. Client-visible: the SQL backends used to answer every interval
BadAggregateInvalidInputs.
- Per backend: IHistorianDataSource.SupportsAggregateFor(aggregate, TypeCode?) (default true;
every production backend declares it, guard-tested). Gateway: false for native
TimeAverage/Total on a Boolean node. SqlServer/QuestDb: true, since they serve Boolean as
0/1 (stepped), so Boolean stays served there, as do the Gateway's raw-evaluated aggregates.
The residual case (a node declared numeric whose AVEVA tag is discrete) cannot be told apart
from a historian fault on the wire and still counts; that needs the gateway to surface
AVEVA's native error code as a deterministic status.
Tests: HistoryAggregateDataTypesTests, guard test, node-manager String/DateTime and per-type
refusals, Gateway capability matrix, DiscreteTagTimeWeightedWireTests (production Gateway
backend over an AVEVA-shaped fake: unsent, 0 health failures, positive controls). Each
mutation (no check, no shared rule, no backend hint, Gateway hint true, shared rule always
true, SQL inheriting the default) fails at least one. Live gate re-run read-only against
AVEVA 2023 R2 via a private HistorianGateway fa9cf31 container: SysPulse TimeAverage on the
wire = BadAggregateNotSupported, health failures unchanged; #801 gate 244 cases pass.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
No public source exists for DNC_ERROR_CLASS / DNC_ERROR_GROUP or their numbers
(the table was written from memory). The iTNC 530 Technical Manual's PLC error
table documents the same class and group NAMES without codes; three real
iTNC 530 records corroborate 7/4, 7/3 and 1/3. DNC and LSV2 numberings are
known to differ (ProgramStatus vs R_RI 26), so the numbers stay unproven.
Docs/comments only; no behaviour change.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A UnsTagReference to a raw tag that carries an "alarm" object produced a UNS
value Variable that read BadWaitingForInitialData forever (G6 live gate,
TestAlarm002Condition on testmachine-015). BuildUnsReferenceVariables now skips
those references; the equipment gets the alarm only as the raw condition wired
as an event notifier of its folder, which is unchanged (the reference still
feeds RawTagPlan.ReferencingEquipmentPaths).
Why condition-only and not "feed the mirror":
- The raw side has no value node for such a tag: AddressSpaceApplier
materialises an alarm tag as a condition OR a value variable, never both.
There is no raw value for the UNS mirror to mirror.
- DriverHostActor skips alarm tags when it builds the value fan-out and write
routing maps (`continue` before the UNS registration), and the driver leaves
them out of its value subscription ("subscribed to 5 refs" with 6 tags in
G6). Feeding the mirror would mean subscribing a value the design says the
tag does not have.
- Docs already state condition-only: ScriptedAlarms.md ("instead of a value
variable"), AlarmTracking.md ("only the condition, with no sibling value
variable"), the v3 design (native alarm = one condition at the raw tag,
surfaced at equipment via notifiers).
- The composer tests that asserted the mirror were incidental: f4f3e17e
(v3 B4-WP1) put the alarm on the fixture's Speed tag to test raw alarm
attachment, and later tests reused Speed for writable / historian / array
checks of the mirror. No commit or doc chose a value mirror for alarm tags.
- ScadaBridge does not read it: its OtOpcUa alarm path is event subscriptions
on the equipment/raw folders (v3 alarm B/C live gate), and a node that never
had a value cannot be a working binding. G6 itself authored the alarm's
Boolean as a separate value tag (TestAlarm002), which is the supported way to
read it.
Tests: the composer fixture moves the alarm onto its own HighTemp tag
(Speed is now a plain historized value tag), with a new test asserting no UNS
Variable for the alarm reference, with positive controls (the raw tag still
carries the equipment path; the value references still emit). New real-SDK
test Alarm_bearing_reference_surfaces_as_the_condition_only_against_real_SDK:
no Variable at the UNS path, the Speed mirror present, one condition, the
equipment folder wired as its notifier. Both new tests fail with the skip
removed. Docs: Uns.md, ScriptedAlarms.md, G6 evidence note.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Compared every R_RI decoder we use (22-28, 30-34, 51) byte-for-byte with pyLSV2 (MIT,
97a3d691) and ran the captured iTNC 530 replies through pyLSV2 itself: no decode
disagreement, so no published value changes.
- Additive read-only String leaves Status/ExecutionStateName, Status/ProgramStateName and
Tool/AxisName (pyLSV2 ExecState / PgmState / decode_tool_info names; out-of-table code =
"Unknown"). They ride the raw leaf's feature, so no extra wire read; raw Int32 leaves unchanged.
- Refusals: 52/72 -> BadOutOfRange, 58 -> BadTimeout, 56 -> BadInvalidState, 57 (outside the
alarm walk) -> BadNoData. IsStable and the 57-only alarm-walk end are unchanged.
Lsv2RefusalCodes names every code (pyLSV2 LSV2StatusCode) in exception/log/probe text.
- Timers 30-34 documented as uint32be seconds (lifetime counters) per pyLSV2, hardware-unproven;
TimersEnabled stays false. Axis/tool units: none on the wire, none assumed.
- Lsv2ReadOnlyPolicy untouched (pinned by a test); R_RI 20/21 left out.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
an owner decision; Lsv2ReadOnlyPolicy is unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- HeidenhainControlFamily + HeidenhainControlFamilies.Classify (Contracts): one authority, ported from
pyLSV2 (MIT) dat_cls.py VersionInfo.control (strip spaces, case-insensitive prefix, ITNC530 first).
Families: ITnc530, Tnc (640/620/320/128), Tnc7, Lathe (CNC PILOT 640 / MANUALplus 620), MillPlus,
LegacyTnc (426/430, not a pyLSV2 class), Unknown.
- New additive read-only leaf Controller/Family (String, Identity feature, derived from the same R_VR
reply: no extra request). Lsv2Versions.Family is computed, so record equality and the #831
identity-change rediscovery signal are unchanged. Probe message + /hosts diagnostics (<host>.family).
- DATA gate now goes through SupportsDataPath(family) (pyLSV2 client.py read_data_path is iTNC-only):
non-iTNC and Unknown => Capabilities/DataLogin Unsupported, DATA login never sent. Replaces the
"model contains itnc" substring check (same result on the real iTNC530 controls).
- No per-family selector pre-gates: pyLSV2's TNC 640 observations (27/28/51/30-34 unknown telegram,
25/26 need DNC) are already handled by the reply-driven refusal/suppression path; tests pin it.
- Lsv2ReadOnlyPolicy, HeidenhainTagWritable and the no-IWritable rule are untouched.
- Simulator: per-family ControlProfiles (strings from the pyLSV2 README tables / protocol.rst), both
R_VR field counts, 124-byte R_PR; HeidenhainControlFamilyTests (classification, gates, decoding,
wire log inside the read-only set, refused selectors asked once).
- docs/drivers/Heidenhain.md: Control families matrix (iTNC 530 hardware-proven; the rest per pyLSV2,
hardware-unproven) + open questions (C_CC buffer size, encrypted passwords, R_RI 20/21).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway alarm feed names an alarm "Galaxy!<Area>.<tag>.<Attr>". The AdminUI Galaxy
picker authors attributeRef "<tag>.<Attr>". OnAlarmFeedTransition reverse-mapped only the
full reference, so a picker-authored native alarm never matched its condition and never
went active. Its ack also dialled the bare reference, which AcknowledgeAlarm refuses.
ResolveAlarmRawPath now matches the full reference, then SourceObjectReference, then the
full reference without its Provider!Area. prefix. A fallback match records the full
reference per RawPath, and AcknowledgeAsync dials it, so the gateway accepts the ack and the
#869 confirmation watch matches. Found and re-verified live in the #615 G6 gate on the
windev test Galaxy.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Found on the docker-dev rig during the #761 Wave-4 gate run (2026-11-12): the documented
bodyless headless deploy (docker-dev/deploy.sh, README "Headless deploy") returned 404 on
both centrals, while the same POST with a JSON body was accepted.
Cause: the optional body was an inferred `DeployRequest?` parameter, which stamps
Accepts(application/json) metadata on the endpoint. For a request with no Content-Type the
routing AcceptsMatcherPolicy prefers endpoints that declare no consumes metadata, and on a
fused admin+driver host MapOtOpcUaMeshGrpcServices has mapped grpc-dotnet's
`{unimplementedService}/{unimplementedMethod}` catch-all, so the request was routed away
from the deploy handler and 404'd. The deploy API on its own does not reproduce it.
The handler now reads the optional body itself: no body (absent or zero-length) is the
headless form, a non-JSON body answers 415 and malformed JSON 400, as the framework's
binding did. New DeployApiBodylessPostTests compose the deploy API with the mesh gRPC
services and drive real HTTP; with the fix reverted the two bodyless cases fail with 404.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Pins ZB.MOM.WW.Telemetry(.Serilog) 0.1.0 -> 0.3.0. The OTel Resource now names the
node: site.id = its application Cluster id (the cluster-<ClusterId> role suffix,
omitted on a legacy node), node.role = its plain roles in canonical order
(admin / driver / admin,driver), service.version = the entry assembly's informational
version (the git SHA). Program passes its resolved EffectiveRoles. The whole
OtOpcUa:Telemetry section goes through the shared ApplyConfiguration, so SiteId /
NodeRole / ServiceVersion / ResourceAttributes:* are operator overrides, and
Exporter=Otlp now also sends the Serilog logs to the same collector.
ObservabilityResourceIdentityTests cover the mapping and the built container's
Resource. Host.Tests 288/288, Host.IntegrationTests 325/327 (2 skipped).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
ZbTelemetryOptions.Meters/ActivitySources are strict allowlists. The host named only
ZB.MOM.WW.OtOpcUa and the LocalDb meter, so the in-process Galaxy driver's galaxy.* spans
and its event pump's galaxy.events.* counters (both on "ZB.MOM.WW.OtOpcUa.Driver.Galaxy")
were silently dropped from /metrics and OTLP. Found exercising OTLP end to end against a
collector (scadaproj#13).
- Galaxy driver: public GalaxyDriverTelemetryNames (MeterName / ActivitySourceName);
GalaxyTelemetry and EventPump reference it.
- Host: ObservabilityExtensions.ObservedMeters / ObservedActivitySources include it.
- Host.IntegrationTests: ObservabilityAllowlistTests assert on the listener side (span
sampled, instrument enabled) with an unregistered-name negative control; dropping the
Galaxy entries fails 3 of 8.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Pins ZB.MOM.WW.LocalDb and .Replication at 0.3.7 (published 2026-11-12).
Wire-compatible; no code change needed.
- 0.3.6 (scadaproj#36): the library sync service enforces
LocalDb:Replication:ApiKey itself. LocalDbSyncAuthInterceptor is kept for
its refuse-every-stream-when-blank rule; doc comment updated. docker-dev
site-a pair: both nodes now read one variable,
OTOPCUA_SITE_A_LOCALDB_SYNC_KEY (same dev default as before), so an
override can never split the pair.
- 0.3.7 (scadaproj#16): a tombstone is held until the peer has it, so a
node offline past TombstoneRetention no longer brings a pruned
deployment back. The ledger grows while a peer is down; optional
TombstoneHardCap (documented in Configuration.md) bounds it.
Runbook, Configuration.md and the cluster-topology rule updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper)
and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked
a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a
priority-1 alarm read 250 and a priority-999 system event 1000.
It now uses AVEVA's default priority ranges, most urgent first:
AVEVA priority AVEVA severity bucket OPC UA Severity
1-250 1 Critical Critical 1000
251-500 2 High High 750
501-750 3 Medium Medium 500
751-999 4 Low Low 250
(history only) 0 not an alarm - 1
Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03
Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1,
400/500 severity 2, 600/700 severity 3, and every priority-999 System.* /
User.* row severity 0 with IsAlarm 0.
- Live and history now use the same number. GalaxyDriver passes the table's
exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket,
which NativeAlarmProjector re-mapped through its generic 200/500/700/900
ladder, so live and history disagreed even before the direction fix.
- History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy,
User.Write...) is not an alarm and reads Severity 1, below every alarm band.
For alarms AVEVA's 1-4 severity is still never the value: the live feed
carries only the priority, so it cannot use it, and history must agree.
- Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity
(lmxopcua#887)"; docs/AlarmTracking.md updated.
- Live re-run of the #801/#886 harness against vd03 HistorianGateway
ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886
run, the 9 others differ only in Severity (priority-700 alarm rows 750 ->
500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md
"#887 re-run", report aveva-gate-sdk2-887.json.gz.
Client-visible: every OPC UA client that ranks or filters Galaxy alarms by
Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has
no code that depends on the old values; its own mixed severity directions are
ScadaBridge#129.
Tests updated because they pinned the inverted table:
- Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/
500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps,
monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001)
- Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium)
- Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999
-> 250, 1 -> 1000; system events -> 1)
- OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 ->
500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4
severity)
New tests:
- Runtime.Tests NativeAlarmRestatementEndToEndTests
.Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real
feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests
pins on the history path)
- EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm
(5 rows, incl. the priority-999 alarm positive control)
- GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through
Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the
driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band
edges off by one; history ignoring priority; a missing AVEVA severity read
as 0.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The SDK memoizes INodeManager3.ValidateEventRolePermissions per (item, event type,
SourceNode). #826 kept it fresh by reflecting into the private
MonitoredNode2.InvalidatePermissionCaches (plus a detach/re-attach fallback). Since #855
condition events never take that channel, and the search for #878 found nothing
production-raised that does except a condition's SDK method audits, which reach it only
with auditing on, SignAndEncrypt and a SecurityAdmin session (nothing grants that role).
Under enforcement the channel verdict is now a flat deny for items on our nodes, so no
cached verdict depends on a grant, and InvalidateFolderEventVerdicts, the reflection,
the fallback, its counter and the guard test are removed. Method audits still reach
Server-object items, decided per event.
Tests: FolderEventVerdictInvalidationTests -> FolderEventVerdictFreshnessTests; new
revoked-grant test (positive control: a still-granted session) and method-audit test
(SecurityAdmin mapped for the test; positive controls: Server-object item, flag off);
the plain-event test runs each mode on a fresh server. Mutation-checked.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A notifier folder read one event source, its NodeId identifier (a RawPath or an EquipmentId). AVEVA stores a
Galaxy object's A&E history under the object's tag_name (Source_Object), so AVEVA's own alarm and event
history reached no production folder. Its lower-case property keys were also missed, so every row read
Severity 1 with no ConditionName.
Sources. A folder's event history now reads its own source plus the Galaxy object of every native condition
that fires on it live: those parented under it and those WireAlarmNotifiers wired to it. Live and history use
the same membership. The object comes from the condition's Galaxy alarm reference, its raw tag's attributeRef,
up to the first '.':
- The composer reads it with the driver's own parser (GalaxyAttributeRef, shared with GalaxyDriver), only for
a GalaxyMxGateway tag with an alarm (RawTagPlan.NativeAlarmReference, part of plan equality).
- The applier binds it after materialising the condition (IOpcUaAddressSpaceSink.BindNativeAlarmHistory,
forwarded by the deferred sink). A rebuild or the condition's removal forgets it.
Each object is read with the #882 rule: its own events and <Object>.<Attribute> rows, never a prefix sibling.
Fan-out. historiangw's ReadEvents filter is a single predicate, so there is one request per source; the wire
contract is unchanged. EventSourceFanOut merges the reads as one source:
- order is (time, source position, arrival), reversed for a reverse read; ties are never re-sorted by EventId,
so the boundary skip stays stable;
- duplicates by EventId are dropped and the merge is cut to the cap;
- a truncated source bounds the page at the time it stopped.
Paging, continuation points (bound to the whole source set), the walked-back reverse read and the tie-cluster
over-fetch are unchanged. A folder with one source is read exactly as before.
ACL. Every source is read inside the folder's own HistoryRead, after AuthorizeHistoryRead (#826). A denied
folder reads nothing and fails closed.
Mapping (EventMapper, property names now case-insensitive):
- Severity: an AVEVA row's priority goes through GalaxyAlarmPriority, the table live Galaxy alarms use
(MxAccessSeverityMapper now delegates to it), so history matches live. Otherwise severity (OtOpcUa's own
rows, which AVEVA stores lower-cased), clamped. AVEVA's own 1-4 severity is ignored. The table ranks a
higher priority as more severe, which inverts AVEVA's convention: filed as #887.
- An AVEVA row whose source_conditionvariable names a native condition that fires on the folder takes that
condition's SourceNode and live ConditionName. Otherwise ConditionName is alarmname or the condition
variable's attribute.
- alarm_id/alarmid map to AlarmId.
Tests:
- GalaxyEquipmentEventHistoryWireTests (4, real SDK session, production Gateway backend, AVEVA-shaped fake
gateway): equipment EqA backed by objects Oven_007 + OvenDoor_07. Covers object and attribute events from
both objects, the prefix sibling excluded, cross-object and in-object ties, forward paging at 1-4 a page,
reverse whole and paged, SourceNode/ConditionName/Severity, the raw device folder, ACL deny with no backend
call plus a granted positive control, and a rebuild forgetting the bindings.
- EventSourceFanOutTests (8), EventMapper AVEVA cases (11), GalaxyAttributeRefTests (16), a composer test and
an applier ordering test.
- Mutation-checked, 17 mutants, all killed. Covered: parent-only membership, no scope, a case-sensitive
condition match, no condition rewrite, no truncation bound, EventId tie order, no sort, no cap, no stop at
the bound, unreversed source order, no dedupe, no '.' boundary, priority ignored, case-sensitive keys, no
applier bind, no deferred forward, and a composer that ignores the driver type. The forget-on-rematerialise
guard survives as belt-and-braces: the rebuild clear covers it.
- Live, read-only, no WinRM, vd03 HistorianGateway ea9f21c: equipment folder EQ-886-ZipsenLeft (objects
DevWinPlatform + Left_001). It read 0 events before and 92 now, equal to the unfiltered read's rows for both
objects. 1/7-event pages and reverse whole/5-event pages agree, and 73 rows resolve to their live condition.
diff_runs vs the #882 run: 221/226 identical. The 5 that differ are expected: DevWinPlatform Severity
1 -> 750/1000, and #881 capabilities.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
ConfigurationBinder appends configured collection items to an existing list, so
the pre-filled [None, Sign, SignAndEncrypt] default made "drop None" a no-op:
every deployment that listed only the secure profiles still advertised an
unsigned/unencrypted None endpoint.
EnabledSecurityProfiles is now null by default; ResolveEnabledSecurityProfiles()
applies the unchanged three-profile default only when nothing is configured.
A set-but-empty list fails startup validation and BuildSecurityPolicies no
longer falls back to a None endpoint on empty input (it throws). Sweep of all
options classes found no other non-empty pre-filled collection default.
Tests: options binding (indexed, JSON, env forms, default, empty, bad name), a
booted-server wire test (no None endpoint, None connection refused with
BadSecurityPolicyRejected, secure connection works; default case is the control).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.
LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.
OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.
Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The SDK starts Server.ServiceLevel at 255 (full service), and OpcUaPublishActor publishes nothing
until the node's first redundancy snapshot arrives, so a restarting pair node advertised 255 for the
~10-13 s it took to join, out-ranking the real Primary (250) for any client that picks the highest
ServiceLevel.
OtOpcUaSdkServer now writes StartupServiceLevel = 0 in OnNodeManagerStartedAsync: after the SDK's
CreateServerObjectAsync wrote 255 and before the server goes Running, so no session can ever read
255. 0 is the design's existing Down / Detached tier (ServiceLevelCalculator returns 0 for a member
that is not Up/Joining, and a node with no snapshot has no role yet). It is below the SDK 2
session-headroom floor (200), so it stands through session churn before the #884 claim, and the
claim's bind replays any level already requested. Single-node deployments are unaffected beyond
the window: the first snapshot publishes 250 as before.
New Node_with_no_requested_level_advertises_the_startup_level_until_one_is_published: reads 0
before the bind, 0 after a bind with nothing to replay, then 250 once published. Without the
startup write it reads 255 on the first session (mutation-checked). docs/Redundancy.md updated for
#884 and #885.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
SDK 2.0.1 recomputes Server.ServiceLevel from session headroom on every session create/close and
overwrites any value >= 200 unless a provider has claimed it through
IServerServiceLevelControl.ClaimServiceLevelControl. SdkServiceLevelPublisher never claimed it, so on
the docker-dev pair both nodes read 255 as soon as a client connected while their own metrics showed
250 (Primary) and 240 (Secondary); the Stale tier's 200 was lifted to 255 too. Levels below 200 (100,
0) were untouched, which is why the bootstrap 100 showed briefly.
The publisher now claims the value at construction and writes through the SDK's writer; a server
without the claim (test doubles) keeps the diagnostics-guarded write. New
Published_level_survives_later_sessions (250/240/200) fails without the claim (reads 255) and passes
with it.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
HistorianGateway answers a per-source ReadEvents (Source_Object = DevWinPlatform) with the
object's own events (SourceName DevWinPlatform) AND its attribute alarms, which it reports as
<Object>.<Attribute> (Source_ProcessVariable, e.g. DevWinPlatform.CPULoadAvg). The Gateway
backend's defensive client-side source filter compared SourceName for equality, so it dropped
the attribute alarms: 70 of the 72 DevWinPlatform events on vd03.
The filter (and the past-the-cap "more events" signal) now uses EventSourceMatch: the source
itself, or <source>.<anything> on the '.' boundary, ordinal. DevWinPlatform never matches
DevWinPlatform2 or DevWinPlatform2.X. This needs no wire change and still makes one request.
Each event keeps its own SourceName. SourceNode stays the condition its stored alarm id names,
which is null for AVEVA rows. The attribute events ride the notifier's own read, so the
per-folder HistoryRead verdict (#826) governs them: a denied folder answers
BadUserAccessDenied before any backend call. The SqlServer and QuestDB backends still match
exactly; they hold only OtOpcUa's own events.
Tests:
- GatewayAttributeEventSourceTests (16): the boundary theory, attribute-in/sibling-out through
the data source, the drain signal, and an exact attribute-named read.
- AttributeEventHistoryWireTests (2, over a real SDK session with the production Gateway
backend on an AVEVA-shaped deterministic gateway): object + attribute events with their own
SourceName, a prefix sibling excluded, paging, and the ACL-on deny with no backend call plus a
granted positive control.
- Mutation-checked: exact match fails both wire tests; dropping the '.' boundary fails the
wire sibling check and 6 unit tests.
- Live AVEVA harness re-run against vd03 HistorianGateway ea9f21c (read-only, no WinRM):
folder DevWinPlatform 2 -> 72 events (whole, 72 1-event pages, reverse); the new #882 check
passes; 221 of 225 shared cases are identical to the #801 SDK2 baseline, and the 4 that
differ are exactly the DevWinPlatform event cases. Recorded in aveva-history-801.md.
Follow-up #886: production folders name RawPaths/EquipmentIds, not Galaxy objects, plus the AVEVA
severity/condition property mapping.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Every Boolean under Server/ServerCapabilities/HistoryServerCapabilities read
false (the SDK default) even though data and event history were served, so a
spec-following client skipped HistoryRead entirely.
Each backend now declares what it serves through its own interface:
- IHistorianDataSource.ReadCapabilities (Data / Events / ServerTimestamps):
Gateway Data|Events; SqlServer + QuestDb add ServerTimestamps (they store
ServerTimeUtc, the Gateway stamps read time); Null declares None. A
reflection guard requires every production source to declare it itself.
- IHistorianDataUpdater.Capabilities (required member): SqlServer and QuestDb
declare Insert/Replace/Update/DeleteRaw/DeleteAtTime; the Gateway provider
has no updater.
The node manager writes the flags on every source/updater assignment
(AdvertisedHistoryCapabilities), and the same declarations drive dispatch:
an update the updater does not declare is BadHistoryOperationUnsupported
without reaching it, the HistoryWrite AccessLevel bit follows a non-empty
declaration, and event-history notifier promotion follows the Events flag.
Event and annotation update flags stay false (nothing dispatches them).
Tests: booted-server wire test per backend + Null + a SqlServer->Gateway
rewire pairing on one session; dispatch gating unit test; the #801 live
gate now asserts the Gateway flags (not run here).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
mxaccessgw#227 (Contracts/Client 0.4.0) adds an opt-in attach acknowledgement on
StreamEvents: a StreamAttached sentinel MxEvent sent first, only after the
stream's subscriber is registered on the session. This closes the #865 attach
race that waiting for "stream requested" only narrowed.
- Bump vendored MxGateway.Client/Contracts 0.3.0 -> 0.4.0 (nuget-packages/,
pulled from the Gitea feed; local-mxgw stays the mapped source).
- IGalaxySubscriber.SupportsStreamAttachedAck (default false, so fakes and older
seams keep the fallback); GatewayGalaxySubscriber reads it from the live
session's capabilities (stream-events-attached-ack) and passes
emitStreamAttached accordingly; TracedGalaxySubscriber forwards it.
- EventPump: records AttachAckExpected before the stream opens (published
before StreamRequested completes); intercepts ev.StreamAttached ahead of the
ReplayGap check - completes StreamAttached and continues: never dispatched,
never counted as received, never a resume cursor (worker_sequence 0). The
signal also completes when the loop ends so no waiter hangs. One pump = one
stream, so a reconnect's new pump has a fresh signal. New counter
galaxy.events.stream_attached.
- AwaitCurrentEventStreamAsync: with the capability, waits on StreamAttached
within the same StreamRequestWait budget (1 s); a missing ack logs a
rate-limited Warning and proceeds instead of hanging. Without the capability
the old StreamRequested wait is the fallback.
Tests (StreamAttachedAckTests, 6): ack-gated subscribe gets its initial value;
capability absent uses the fallback; missing ack times out with a warning; the
sentinel is never dispatched; a dead stream releases ack waiters; reconnect
gives each stream a fresh signal. With the ack wait skipped, 3 of them fail.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi