Joseph Doherty aa60b3e34e test(soak): #799 place the soak's UNS folder after #808; Windows x64 port of the lifecycle soak harness
v2-ci / unit-tests (push) Has been cancelled
Acceptance runs for #799 (owner scope 2026-11-12: Windows x64 + Linux) on current master.

Fixture: since #808 an UNS folder the authority snapshot does not place is denied under enforcement (fail
closed). The canonical soak creates its own "SoakEquipment" folder but never placed it, so on master the very
first cycle's UNS monitored item came back bad (retained failed Linux launch on b61f3e05, cycle 1). The rig
gains AdditionalFolderScopes (merged into FolderScopes by Enforce) and the soak places its folder there, as a
deployed generation does - the same fixture gap #888 fixed for the SDK matrix. No server authorization code,
cap, baseline or canonical operation changed; the soak test bodies are otherwise byte-identical to b18f9723.

Windows port (test/harness only, opt-in):
- DescriptorCountsAsync gains a Windows branch: total = every handle in the process handle table, PKI = disk
  file/directory handles whose GetFinalPathNameByHandle path lies under a canonicalised PKI root; dedicated
  thread under the same 5 s bound as the macOS lsof probe.
- Descriptor controls enabled on Windows (symlink alias; timeout control via cmd.exe + ping).
- LateSlopeRun.ValidateRequest accepts Linux ARM64 or Windows x64; duration/runtime/leak tracking unchanged.
- late-slope/analyze.py: expected architecture is a module constant (Linux default Arm64 unchanged).
- windows/: prepare.py (win-x64 self-contained 10.0.14 bundle + manifest), launch.ps1 (container.sh
  equivalent: bundle re-verification, 2/2 controls first, PID/apphost/coreclr verification, external
  sampler, 7440 s outer deadline), analyze.py (Linux row/window logic, X64), README with every adaptation.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 12:42:16 -05:00
Joseph Doherty b61f3e0560 fix(galaxy): AVEVA priority 1 is the most urgent: Galaxy alarm Severity follows AVEVA's priority bands, live and history alike (#887)
v2-ci / unit-tests (push) Has been cancelled
GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper)
and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked
a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a
priority-1 alarm read 250 and a priority-999 system event 1000.

It now uses AVEVA's default priority ranges, most urgent first:

  AVEVA priority  AVEVA severity  bucket    OPC UA Severity
  1-250           1 Critical      Critical  1000
  251-500         2 High          High       750
  501-750         3 Medium        Medium     500
  751-999         4 Low           Low        250
  (history only)  0 not an alarm  -            1

Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03
Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1,
400/500 severity 2, 600/700 severity 3, and every priority-999 System.* /
User.* row severity 0 with IsAlarm 0.

- Live and history now use the same number. GalaxyDriver passes the table's
  exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket,
  which NativeAlarmProjector re-mapped through its generic 200/500/700/900
  ladder, so live and history disagreed even before the direction fix.
- History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy,
  User.Write...) is not an alarm and reads Severity 1, below every alarm band.
  For alarms AVEVA's 1-4 severity is still never the value: the live feed
  carries only the priority, so it cannot use it, and history must agree.
- Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity
  (lmxopcua#887)"; docs/AlarmTracking.md updated.
- Live re-run of the #801/#886 harness against vd03 HistorianGateway
  ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886
  run, the 9 others differ only in Severity (priority-700 alarm rows 750 ->
  500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md
  "#887 re-run", report aveva-gate-sdk2-887.json.gz.

Client-visible: every OPC UA client that ranks or filters Galaxy alarms by
Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has
no code that depends on the old values; its own mixed severity directions are
ScadaBridge#129.

Tests updated because they pinned the inverted table:
- Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/
  500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps,
  monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001)
- Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium)
- Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999
  -> 250, 1 -> 1000; system events -> 1)
- OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 ->
  500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4
  severity)

New tests:
- Runtime.Tests NativeAlarmRestatementEndToEndTests
  .Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real
  feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests
  pins on the history path)
- EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm
  (5 rows, incl. the priority-999 alarm positive control)
- GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through

Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the
driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band
edges off by one; history ignoring priority; a missing AVEVA severity read
as 0.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 12:14:49 -05:00
Joseph Doherty fa811feb3d fix(opcua): drop the reflective folder-event verdict invalidation; deny the SDK channel under enforcement (#878)
v2-ci / unit-tests (push) Waiting to run
The SDK memoizes INodeManager3.ValidateEventRolePermissions per (item, event type,
SourceNode). #826 kept it fresh by reflecting into the private
MonitoredNode2.InvalidatePermissionCaches (plus a detach/re-attach fallback). Since #855
condition events never take that channel, and the search for #878 found nothing
production-raised that does except a condition's SDK method audits, which reach it only
with auditing on, SignAndEncrypt and a SecurityAdmin session (nothing grants that role).

Under enforcement the channel verdict is now a flat deny for items on our nodes, so no
cached verdict depends on a grant, and InvalidateFolderEventVerdicts, the reflection,
the fallback, its counter and the guard test are removed. Method audits still reach
Server-object items, decided per event.

Tests: FolderEventVerdictInvalidationTests -> FolderEventVerdictFreshnessTests; new
revoked-grant test (positive control: a still-granted session) and method-audit test
(SecurityAdmin mapped for the test; positive controls: Server-object item, flag off);
the plain-event test runs each mode on a fresh server. Mutation-checked.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:45:54 -05:00
Joseph Doherty 3a312ffdd1 fix(history): a folder's event history reads the Galaxy objects behind its native conditions (#886)
v2-ci / unit-tests (push) Has been cancelled
A notifier folder read one event source, its NodeId identifier (a RawPath or an EquipmentId). AVEVA stores a
Galaxy object's A&E history under the object's tag_name (Source_Object), so AVEVA's own alarm and event
history reached no production folder. Its lower-case property keys were also missed, so every row read
Severity 1 with no ConditionName.

Sources. A folder's event history now reads its own source plus the Galaxy object of every native condition
that fires on it live: those parented under it and those WireAlarmNotifiers wired to it. Live and history use
the same membership. The object comes from the condition's Galaxy alarm reference, its raw tag's attributeRef,
up to the first '.':
- The composer reads it with the driver's own parser (GalaxyAttributeRef, shared with GalaxyDriver), only for
  a GalaxyMxGateway tag with an alarm (RawTagPlan.NativeAlarmReference, part of plan equality).
- The applier binds it after materialising the condition (IOpcUaAddressSpaceSink.BindNativeAlarmHistory,
  forwarded by the deferred sink). A rebuild or the condition's removal forgets it.
Each object is read with the #882 rule: its own events and <Object>.<Attribute> rows, never a prefix sibling.

Fan-out. historiangw's ReadEvents filter is a single predicate, so there is one request per source; the wire
contract is unchanged. EventSourceFanOut merges the reads as one source:
- order is (time, source position, arrival), reversed for a reverse read; ties are never re-sorted by EventId,
  so the boundary skip stays stable;
- duplicates by EventId are dropped and the merge is cut to the cap;
- a truncated source bounds the page at the time it stopped.
Paging, continuation points (bound to the whole source set), the walked-back reverse read and the tie-cluster
over-fetch are unchanged. A folder with one source is read exactly as before.

ACL. Every source is read inside the folder's own HistoryRead, after AuthorizeHistoryRead (#826). A denied
folder reads nothing and fails closed.

Mapping (EventMapper, property names now case-insensitive):
- Severity: an AVEVA row's priority goes through GalaxyAlarmPriority, the table live Galaxy alarms use
  (MxAccessSeverityMapper now delegates to it), so history matches live. Otherwise severity (OtOpcUa's own
  rows, which AVEVA stores lower-cased), clamped. AVEVA's own 1-4 severity is ignored. The table ranks a
  higher priority as more severe, which inverts AVEVA's convention: filed as #887.
- An AVEVA row whose source_conditionvariable names a native condition that fires on the folder takes that
  condition's SourceNode and live ConditionName. Otherwise ConditionName is alarmname or the condition
  variable's attribute.
- alarm_id/alarmid map to AlarmId.

Tests:
- GalaxyEquipmentEventHistoryWireTests (4, real SDK session, production Gateway backend, AVEVA-shaped fake
  gateway): equipment EqA backed by objects Oven_007 + OvenDoor_07. Covers object and attribute events from
  both objects, the prefix sibling excluded, cross-object and in-object ties, forward paging at 1-4 a page,
  reverse whole and paged, SourceNode/ConditionName/Severity, the raw device folder, ACL deny with no backend
  call plus a granted positive control, and a rebuild forgetting the bindings.
- EventSourceFanOutTests (8), EventMapper AVEVA cases (11), GalaxyAttributeRefTests (16), a composer test and
  an applier ordering test.
- Mutation-checked, 17 mutants, all killed. Covered: parent-only membership, no scope, a case-sensitive
  condition match, no condition rewrite, no truncation bound, EventId tie order, no sort, no cap, no stop at
  the bound, unreversed source order, no dedupe, no '.' boundary, priority ignored, case-sensitive keys, no
  applier bind, no deferred forward, and a composer that ignores the driver type. The forget-on-rematerialise
  guard survives as belt-and-braces: the rebuild clear covers it.
- Live, read-only, no WinRM, vd03 HistorianGateway ea9f21c: equipment folder EQ-886-ZipsenLeft (objects
  DevWinPlatform + Left_001). It read 0 events before and 92 now, equal to the unfiltered read's rows for both
  objects. 1/7-event pages and reverse whole/5-event pages agree, and 73 rows resolve to their live condition.
  diff_runs vs the #882 run: 221/226 identical. The 5 that differ are expected: DevWinPlatform Severity
  1 -> 750/1000, and #881 capabilities.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:45:48 -05:00
Joseph Doherty a83bf1fa27 fix(opcua): a configured OpcUa:EnabledSecurityProfiles list replaces the default, so None can be dropped (#879)
v2-ci / unit-tests (push) Has been cancelled
ConfigurationBinder appends configured collection items to an existing list, so
the pre-filled [None, Sign, SignAndEncrypt] default made "drop None" a no-op:
every deployment that listed only the secure profiles still advertised an
unsigned/unencrypted None endpoint.

EnabledSecurityProfiles is now null by default; ResolveEnabledSecurityProfiles()
applies the unchanged three-profile default only when nothing is configured.
A set-but-empty list fails startup validation and BuildSecurityPolicies no
longer falls back to a None endpoint on empty input (it throws). Sweep of all
options classes found no other non-empty pre-filled collection default.

Tests: options binding (indexed, JSON, env forms, default, empty, bad name), a
booted-server wire test (no None endpoint, None connection refused with
BadSecurityPolicyRejected, secure connection works; default case is the control).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:38:42 -05:00
Joseph Doherty be28aa4432 fix(opcua-client): send UserName passwords in the legacy RSA format so 65-char API keys log in to SDK 1.5 servers (#880)
SDK 2.0.1's UserNameIdentityTokenHandler encrypts a password longer than 64 bytes
(a private RsaEncryptedSecretPasswordThreshold, no setting) as an RsaEncryptedSecret
with EncryptionAlgorithm=null. SDK 1.5.378 (.106 and .182) decrypts only the legacy
format under RSA policies; its SecurityPolicies.Decrypt answers a null algorithm with
BadIdentityTokenInvalid ("Unexpected encryption algorithm") before any key check.
Every production API key is 65 chars, so no SDK 2 OtOpcUa client could use one
against QA (b8b4c18f), a rollback target or an older third-party server.

LegacyRsaUserNameIdentityTokenHandler (Driver.OpcUaClient.Session, plugged in through
the public UserIdentity(IUserIdentityTokenHandler) ctor) always uses the legacy
format, RSA-OAEP(len|password|serverNonce) under the server certificate, under an RSA
policy. That is what SDK 2 sends for passwords of 64 bytes or less and what SDK 1.5
clients always send. The legacy format has no size limit (the plaintext is
length-framed over as many RSA blocks as it needs), and an SDK 2 server reads both
formats. Policy None, the ECC policies and a missing certificate go to the SDK
handler unchanged.

OpcUaUserIdentityFactory.UserName is now the one UserName identity the driver, the
AdminUI browse and Client.Shared (CLI/UI) present. Client.Shared references .Session
for it.

Tests: handler unit tests (all three RSA policies, the 1.5-required algorithm URI,
SDK 2 server-side decrypt, the session Copy() keeps the type, None unchanged, and an
SDK control pinning the 64/65-byte switch); a Client.Shared identity test; and an
SDK2<->SDK2 integration test where a 65-char key is admitted in both formats and a
wrong 65-char key reaches the key check (BadIdentityTokenRejected). The #800 Windows
gate's SDK 2 CLI 65-char case now gates against the 1.5 server too.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:12:27 -05:00
Joseph Doherty 3fff439b11 fix(redundancy): advertise ServiceLevel 0 until the node has a redundancy level (#885)
v2-ci / unit-tests (push) Has been cancelled
The SDK starts Server.ServiceLevel at 255 (full service), and OpcUaPublishActor publishes nothing
until the node's first redundancy snapshot arrives, so a restarting pair node advertised 255 for the
~10-13 s it took to join, out-ranking the real Primary (250) for any client that picks the highest
ServiceLevel.

OtOpcUaSdkServer now writes StartupServiceLevel = 0 in OnNodeManagerStartedAsync: after the SDK's
CreateServerObjectAsync wrote 255 and before the server goes Running, so no session can ever read
255. 0 is the design's existing Down / Detached tier (ServiceLevelCalculator returns 0 for a member
that is not Up/Joining, and a node with no snapshot has no role yet). It is below the SDK 2
session-headroom floor (200), so it stands through session churn before the #884 claim, and the
claim's bind replays any level already requested. Single-node deployments are unaffected beyond
the window: the first snapshot publishes 250 as before.

New Node_with_no_requested_level_advertises_the_startup_level_until_one_is_published: reads 0
before the bind, 0 after a bind with nothing to replay, then 250 once published. Without the
startup write it reads 255 on the first session (mutation-checked). docs/Redundancy.md updated for
#884 and #885.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:11:11 -05:00
Joseph Doherty 5e3fb4229d test(redundancy): exercise SessionClosing in the #884 ServiceLevel claim test
v2-ci / unit-tests (push) Has been cancelled
The claim test disposed its sessions, which may leave them to time out rather than raise
SessionClosing, so only the SessionCreated half of the SDK's session-headroom overwrite was
proven. Sessions now close explicitly, a later level (230, inside the SDK's >= 200 overwrite
band for every case, where the old level-10 left the 200 case at 190 and so unexercised) is read
back on a surviving session after another one closes on its own. Probed without the claim: the
close-only read fails (255) in all three cases.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 11:00:59 -05:00
Joseph Doherty f66b9daec0 fix(redundancy): claim Server.ServiceLevel so SDK 2 stops overwriting 250/240 with 255 (#801)
SDK 2.0.1 recomputes Server.ServiceLevel from session headroom on every session create/close and
overwrites any value >= 200 unless a provider has claimed it through
IServerServiceLevelControl.ClaimServiceLevelControl. SdkServiceLevelPublisher never claimed it, so on
the docker-dev pair both nodes read 255 as soon as a client connected while their own metrics showed
250 (Primary) and 240 (Secondary); the Stale tier's 200 was lifted to 255 too. Levels below 200 (100,
0) were untouched, which is why the bootstrap 100 showed briefly.

The publisher now claims the value at construction and writes through the SDK's writer; a server
without the claim (test doubles) keeps the diagnostics-guarded write. New
Published_level_survives_later_sessions (250/240/200) fails without the claim (reads 255) and passes
with it.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 10:55:49 -05:00
Joseph Doherty da948e5fb5 fix(history): a folder's event history includes its object's attribute alarms (#882)
v2-ci / unit-tests (push) Has been cancelled
HistorianGateway answers a per-source ReadEvents (Source_Object = DevWinPlatform) with the
object's own events (SourceName DevWinPlatform) AND its attribute alarms, which it reports as
<Object>.<Attribute> (Source_ProcessVariable, e.g. DevWinPlatform.CPULoadAvg). The Gateway
backend's defensive client-side source filter compared SourceName for equality, so it dropped
the attribute alarms: 70 of the 72 DevWinPlatform events on vd03.

The filter (and the past-the-cap "more events" signal) now uses EventSourceMatch: the source
itself, or <source>.<anything> on the '.' boundary, ordinal. DevWinPlatform never matches
DevWinPlatform2 or DevWinPlatform2.X. This needs no wire change and still makes one request.
Each event keeps its own SourceName. SourceNode stays the condition its stored alarm id names,
which is null for AVEVA rows. The attribute events ride the notifier's own read, so the
per-folder HistoryRead verdict (#826) governs them: a denied folder answers
BadUserAccessDenied before any backend call. The SqlServer and QuestDB backends still match
exactly; they hold only OtOpcUa's own events.

Tests:
- GatewayAttributeEventSourceTests (16): the boundary theory, attribute-in/sibling-out through
  the data source, the drain signal, and an exact attribute-named read.
- AttributeEventHistoryWireTests (2, over a real SDK session with the production Gateway
  backend on an AVEVA-shaped deterministic gateway): object + attribute events with their own
  SourceName, a prefix sibling excluded, paging, and the ACL-on deny with no backend call plus a
  granted positive control.
- Mutation-checked: exact match fails both wire tests; dropping the '.' boundary fails the
  wire sibling check and 6 unit tests.
- Live AVEVA harness re-run against vd03 HistorianGateway ea9f21c (read-only, no WinRM):
  folder DevWinPlatform 2 -> 72 events (whole, 72 1-event pages, reverse); the new #882 check
  passes; 221 of 225 shared cases are identical to the #801 SDK2 baseline, and the 4 that
  differ are exactly the DevWinPlatform event cases. Recorded in aveva-history-801.md.

Follow-up #886: production folders name RawPaths/EquipmentIds, not Galaxy objects, plus the AVEVA
severity/condition property mapping.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 10:34:29 -05:00
Joseph Doherty b27b5b9cc1 fix(history): advertise HistoryServerCapabilities from the wired backend (#881)
v2-ci / unit-tests (push) Has been cancelled
Every Boolean under Server/ServerCapabilities/HistoryServerCapabilities read
false (the SDK default) even though data and event history were served, so a
spec-following client skipped HistoryRead entirely.

Each backend now declares what it serves through its own interface:
- IHistorianDataSource.ReadCapabilities (Data / Events / ServerTimestamps):
  Gateway Data|Events; SqlServer + QuestDb add ServerTimestamps (they store
  ServerTimeUtc, the Gateway stamps read time); Null declares None. A
  reflection guard requires every production source to declare it itself.
- IHistorianDataUpdater.Capabilities (required member): SqlServer and QuestDb
  declare Insert/Replace/Update/DeleteRaw/DeleteAtTime; the Gateway provider
  has no updater.

The node manager writes the flags on every source/updater assignment
(AdvertisedHistoryCapabilities), and the same declarations drive dispatch:
an update the updater does not declare is BadHistoryOperationUnsupported
without reaching it, the HistoryWrite AccessLevel bit follows a non-empty
declaration, and event-history notifier promotion follows the Events flag.
Event and annotation update flags stay false (nothing dispatches them).

Tests: booted-server wire test per backend + Null + a SqlServer->Gateway
rewire pairing on one session; dispatch gating unit test; the #801 live
gate now asserts the Gateway flags (not run here).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 10:31:29 -05:00
Joseph Doherty f607ee7502 test(historian): #801 real-AVEVA history gate over the SDK wire (env-gated)
AvevaGatewayHistoryLiveGateTests boots the server in-process, wires the production
Gateway backend (HistorianBackendRegistry -> GatewayHistorianDataSource) to a real
HistorianGateway and drives HistoryRead over a real SDK session: raw (all, paged,
reverse, bounds), modified, the ten served aggregates and seven refused ones, AtTime,
events (all, 1-event pages, reverse), a missing tag, HistoryServerCapabilities and
node metadata, and a HistoryUpdate that must be refused (sandbox-bound node only).
Every wire answer is compared with the backend's direct answer; the run is dumped as
JSON for cross-SDK and SQL comparison. Skips unless HISTGW_GATEWAY_ENDPOINT and
HISTGW_GATEWAY_APIKEY are set; read-only by construction.

scripts/validation/aveva-history-801: run/compare instructions, the SDK 1.5.378
baseline port patch (API spelling only), and the diff / SQL / aggregate / histgw-cli
comparison scripts.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 10:02:21 -05:00
Joseph Doherty e5a03e3cce test(acl): pin the fail-closed rule for non-condition events on folder items (#838 item 3)
v2-ci / unit-tests (push) Waiting to run
A folder event item under enforcement withholds an event that names no live
condition; flag off, the SDK's own type + SourceNode check applies. Positive
controls: the same event reaches the item flag-off and a condition event
reaches it flag-on. Mutation-checked: IsNotifierEventVisibleTo returning true
for a non-condition event fails the test.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 08:54:43 -05:00
Joseph Doherty 2e948d3139 fix(opcua): #874 route the server's OPC UA SDK log output to the host logger
The host handed the SDK a provider-less telemetry context, so SDK-side
refusals — identity-token decryption (the SDK 2 RsaEncryptedSecret clock
window, #873), certificate validation, secure-channel faults — left no server
log line (found on windev during the #800 Windows validation). The hosted
service now creates one ServerSdkTelemetry context from its ILoggerFactory
(Warning and above, SDK categories, rate-limited 20/min per category) and
shares it between OtOpcUaSdkServer and the ApplicationInstance; released on
dispose. Test: an untrusted client's rejection reaches the captured log.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 16:37:03 -05:00
Joseph Doherty 36583ee6f4 test(opcua): #870 review — pin the 1000th-newest duplicate-window boundary; serialise the ring-queue switch users
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 15:20:31 -05:00
Joseph Doherty bcde93056a perf(opcua): #870 ring-buffer event monitored-item queue
Since #855 condition events are queued to folder event items under the node
manager Lock. At a full DiscardOldest queue the SDK's EventQueueHandler
dequeues the head of EventMonitoredItemQueue, a List.RemoveAt(0) shift of the
whole queue (~1 us/item at QueueSize 1000, ~10 us at 10000).

OtOpcUaSdkServer.CreateMonitoredItemQueueFactory now wraps the SDK factory in
RingEventQueueFactory: event queues are RingEventMonitoredItemQueue (O(1)
discard), data-change queues, durable requests and disposal go to the SDK
factory unchanged. A factory set through StandardServer.MonitoredItemQueueFactory
is used as-is.

The SDK queue is storage only (decompiled 2.0.1): DiscardOldest, overflow-event
positions and discarded/overflow counters live in EventQueueHandler, which is
unchanged. The ring reproduces QueueSize 0 initial + BadInternalError enqueue,
drop-oldest at Count == QueueSize, FIFO dequeue, SetQueueSize keep-newest /
keep-oldest, the newest-1000 duplicate window via IsEventRaisedFor, no-op
Dispose. RingEventMonitoredItemQueueParityTests drive both queues, and the SDK
EventQueueHandler over both factories, with the same random sequences.

FolderEventDeliveryPerfTests gains Ring_vs_sdk_event_queue (A/B in one process
via the internal OtOpcUaSdkServer.RingEventQueues switch).

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 15:15:45 -05:00
Joseph Doherty 733dfe94da fix(opcua): #855 perf review 3 — weak filter-group registry; where clause validated; sharing pinned
- The filter-group registry holds groups weakly (the filter->group table is
  the only strong reference), sweeps dead entries amortised and counts only
  live shapes against the 4096 cap; filters past the cap are counted on the
  new meter otopcua.opcua.condition_events.filter_groups_unshared.
- A group validates its where clause too (restored, never-validated filters
  evaluate like validated ones).
- Test: value-equal filters cost one projection per locale set per report.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 14:20:19 -05:00
Joseph Doherty b77bb2ded1 fix(opcua): #855 perf review 2 — where clause in the group bucket key; pin dedupe, modify and keys
- Filter-group buckets include the where clause's (value-based) hash, so
  per-source filters sharing a select list are not all scanned under Lock.
- Locale keys are cached per session array.
- Tests: a notifier reached twice in one walk (Line above two wired
  equipment) gets each event once on both paths (fails without the
  per-report set); queued events re-projected by a modify are identical on
  both paths; locale keys unambiguous and where clauses hash by value.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 14:10:02 -05:00
Joseph Doherty ca0e73fbca fix(opcua): #855 perf review 1 — groups evaluate their own filter clone; lazy fields; tighter equivalence tests
- A filter group owns a deep clone of its first filter, validated once and
  evaluated under the group's lock: no item-owned filter is mutated or raced
  (Validate mutates a select clause).
- The projection is computed in the SDK's order: where clause first, fields
  only for an item that will queue.
- Unambiguous locale key; counter for filters given a private group past the
  registry cap; DeliveryCache getter returns its own allocation.
- UseProjectedEventDelivery=false also asks the role and grant checks per
  item, so the equivalence test compares against the pre-optimisation path.
- Equivalence test: same select list under three where clauses, a filter
  modified mid-run, a session with other locales, an ungranted anonymous
  Server-object item, per-rig counter; plus a small overflowing queue with
  DiscardOldest true and false.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:59:22 -05:00
Joseph Doherty 98d962b24b perf(opcua): #855 — shared per-report projection for condition events under Lock
Condition events delivered to many event items (folder and Server-object)
no longer pay the SDK's per-item QueueEvent(IFilterTarget) work under the
node-manager Lock: the role-permission verdict is shared per (session,
identity), the #826 grant check per identity per hop, and the where clause +
select-clause projection per (value-equal EventFilter, locales); each item
gets its own EventFieldList over the shared read-only fields. The SDK's
QueueEvent body is reproduced under the item's own lock (three private SDK
members, guard-tested); anything outside that shape falls back to the SDK.
The per-report duplicate check replaces the SDK's O(queue) scan.

ProjectedEventDeliveryWireTests compares both paths over the wire.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:42:29 -05:00
Joseph Doherty a8f4be616b test(opcua): opt-in perf harness for #855 folder event per-item delivery
FolderEventDeliveryPerfTests (Category=Perf, skipped unless OTOPCUA_EVENT_PERF=1)
reports per-alarm-report node-manager Lock hold and end-to-end delivery latency
for one equipment folder with N = 1/10/50/200 event items, ACL on/off, folder
subscribers publishing or stalled at a full queue; the latency of an i=2253
subscriber while folder subscribers stall; and a QueueSize sensitivity sweep.
Compiles against the pre-#855 tree for a before/after comparison.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:20:58 -05:00
Joseph Doherty c9e5c8dcf7 Merge #855 folder event items: per-item delivery under the node manager, ConditionRefresh cut matches the Server object
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:07:21 -05:00
Joseph Doherty ec17a8797b fix(opcua): #855 review 4 — per-item "known" in the folder cut; pin the post-stall liveness check
- RefreshDirectItemsWithCut keys its "decided off Lock" set per (item,
  condition), so a condition one item's walk saw is still decided for another.
- The deferral warning no longer blames slow folder subscribers (no folder of
  ours defers since #855).
- FolderEventFloodWireTests' removal test now asserts the folder item got
  nothing and the Server object exactly the pre-stall event (it passed with
  the post-stall liveness re-check deleted).

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 13:05:06 -05:00
Joseph Doherty 7783fadae1 fix(opcua): #855 review 3 — plain refresh skips removed conditions; per-hop failure isolation
- Both plain ConditionRefresh paths (Server object and folder) skip a
  condition a deploy removed or replaced between the off-Lock walk and the
  queueing (the SDK base did not either; only the cut path checked).
- A failure delivering at one notifier hop is logged and the walk continues
  to the remaining hops; a failure deciding the Server-object items withholds
  only them.
- Test: a condition removed during a plain refresh (folder + Server object).

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:51:03 -05:00
Joseph Doherty f775625805 fix(opcua): #855 review 2 — frozen replay skips non-live conditions; per-hop ACL resolution; drain never inline
- QueueFrozenReplay's verdict refuses a condition a deploy removed or replaced
  since the cut (Server-object and folder), so the cut path cannot replay a
  ghost or judge a replaced scripted alarm on its old folder.
- DeliverToNotifierItems resolves the #826 decision's item-independent part
  (live condition, notifier check, scopes) once per hop; only the grant and
  SDK role checks stay per item.
- A deferred delivery's drain starts on the pool, never inline under Lock.
- Test: a condition removed between the cut and its replay (folder + Server
  object).

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:40:06 -05:00
Joseph Doherty d2b1545659 fix(opcua): #855 review 1 — re-decide frozen replay entries; a failed delivery is not a deferral
- QueueFrozenReplay re-asks each item's verdict right before each entry's gate
  hold (Server-object and folder cut paths): a grant revoked between the
  pre-Lock verdicts and the replay no longer lets the replay through. A denied
  entry is also removed from the cut's re-sent set.
- ReportEventWithoutBlocking logs and returns on a delivery that faulted
  inline instead of booking it as a deferral episode (which ran the drain and
  ClearStaleRefreshCuts under the event-report gate while Lock was held).
- OnConditionReportEvent isolates failures per Server-object item.
- Tests: revocation between cut and replay (folder + Server object), throwing
  hop not booked as a deferral; production-overload sampling inside Lock.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:31:02 -05:00
Joseph Doherty 8a0032bfdf fix(aggregates): live TimeAverage/Total leave the span before an Uncertain first value out (#821)
When the data starts inside an interval (no start bound) and its first value is
Uncertain, the frozen 1.5.378.182 AverageAggregateCalculator integrated the
uncovered span as a ramp from 0 and divided TimeAverage by the whole interval:
GetRegionsInValueSet (ignoreBadData, sloped) overwrites the BadNoData start
region's status with UncertainDataSubNormal in its one branch without a not-Bad
guard. Live AggregateFilter therefore disagreed with HistoryRead and Part 13
§5.4.3.6/§5.4.3.8 ("No Start Bound: Calculate Partial Interval"); QP: Total
188.96 vs 163.96, TimeAverage 9.448 vs 10.931. SDK 2.0.1 stock does the same.
Owner-approved 2026-11-11.

- New app-owned CoveredTimeAverageAggregateCalculator subclasses the baseline
  and recomputes only TimeAverage/Total, restoring the Bad status of a region
  that starts at a Bad point (only the start bound can). Only such an interval's
  value changes; status, timestamps, type and bits are the baseline's. Stepped
  and TreatUncertainAsBad=true never reached the defect. CompatibilityAggregate-
  Factory routes exactly those two IDs; copied SDK files untouched.
- Golden test: 0 fixture vectors change (every data set has a usable value at
  -10 s), asserted. New sweep over late-start variants of every data set (cut
  +5 s / +25 s, first non-Bad sample Uncertain, all directions/stepping/configs/
  incremental): 150 / 142 of 384 change, each pinned to a baseline-derived
  oracle (untouched baseline's value with that sample Good, its status/bits on
  the variant itself) - never our calculator. Plus a hand-computed case.
- Live-vs-HistoryRead parity (TimeWeightedAggregator) forward + reverse, no
  masks, with discrimination against the pre-#821 baseline; QualityMix now
  compares QP's TimeAverage/Total with the live oracle on both SQL backends;
  booted-runtime facts test expects 163.96 / 10.93.
- README recorded decision, ServerAggregateConfiguration remarks, oracle
  remarks, docs/Historian.md and .claude/rules/historian.md updated.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:30:01 -05:00
Joseph Doherty d9b23e0b95 feat(opcua): per-item delivery for folder event items; folder ConditionRefresh gets the #854 cut (#855)
Condition events reaching one of our notifiers no longer go through the SDK
MonitoredNode2 channel: the walk serves the attached items itself, per item and
per event (audit guard, uncached INodeManager3 verdict, item gate/cut,
QueueEvent), as the Server-object path does. No notifier of ours defers any
more; the #838 deferral queue and the #854 cut stay as the safety net and
folder items share the cut (RefreshDirectItems, flag on and off). An event
whose walk suspends is marked deferred before it suspends.

Tests produce deferral with a notifier-stall probe instead of holding a folder
item's SDK lock (which would now block the reporter). New
FolderConditionRefreshWireTests; design note in docs/plans.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:18:11 -05:00
Joseph Doherty ed05d50795 fix(aggregates): live PercentGood/DurationGood count Good time only (#809)
The frozen 1.5.378.182 StatusAggregateCalculator counts Uncertain regions as
Good under TreatUncertainAsBad=false, so live AggregateFilter PercentGood /
DurationGood disagreed with HistoryRead (Part 13 §5.4.3.31/§5.4.3.33, Mantis
0006166) whenever Uncertain data was present. Owner-approved 2026-11-11.

- New app-owned GoodOnlyStatusAggregateCalculator subclasses the baseline and
  replaces only the PercentGood/DurationGood computation (Good regions only);
  CompatibilityAggregateFactory routes exactly those two IDs to it. The copied
  SDK files are untouched; the other 35 aggregates are byte-identical.
- Golden test: the 64 changed vectors (38 PercentGood + 26 DurationGood) are
  exempted exactly — those whose baseline output differs from the same case's
  baseline TreatUncertainAsBad=true twin — and pinned to that twin (baseline
  evidence, not regenerated from the implementation); plus a full Good-only
  pin over all 352 PercentGood/DurationGood vectors and a hand-computed case.
- Live-vs-history parity over Good/Uncertain/Bad mixes (no masks), with a
  discrimination check against the pre-#809 baseline; the booted-runtime facts
  test now expects 8000 ms / 40 %.
- SdkAggregateOracle: Run/RunLive = the registered factory; RunSdkAsIs = the
  untouched baseline; its Part13GoodCalculator duplicate is removed.
- README (recorded decision), ServerAggregateConfiguration remarks,
  docs/Historian.md and .claude/rules/historian.md updated.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 12:05:34 -05:00
Joseph Doherty 284358a2e2 test(opcua): ConditionRefresh stress runs until deferral was actually exercised (#838 follow-on)
Under load 40 refreshes could finish before any stall overlapped a report, failing the 'stress must have
run with deferred events' precondition. Keep refreshing (>=40, ceiling 90 s) until deferral is seen.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 10:36:49 -05:00
Joseph Doherty 4bb9c453a3 test(opcua): event-queue overflow with the per-folder/Server-object ACL active (#838 item 2)
EventQueueOverflowAclWireTests drives >4096 condition events at a folder notifier
item and a Server-object (i=2253) item with Security:Acl enforcement on, a
non-publishing client, and a second session reading a node-manager node throughout:

- denied (EqA-owned scripted) events interleaved with allowed native ones, under one
  Lock hold and per-projection: no deadlock, reads stay bounded, deferral peak stays
  within 2 x (MaxDeferredEventsPerCondition + 1), delivery <= item QueueSize, oldest
  dropped / newest kept in report order, one EventQueueOverflowEventType published ahead
  of the survivors (SDK DiscardOldest, Part 4 5.13.1.5), zero denied events delivered;
- a grant revoked (state.Apply -> revalidation, re-entering Lock) while a deferred tail
  waits behind a full folder channel: neither the tail nor later events reach the
  revoked session's folder or Server-object item; a still-granted session on the same
  channel receives all of it.

Falsified: with enforcement off (and with the revocation removed) all three cases fail.
No production defect found.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
2026-11-11 10:35:12 -05:00
Joseph Doherty fe48458a41 fix(opcua): Server-object ConditionRefresh off Lock unless deferring; cut path O(conditions) with replay queued off Lock (#854 review)
Review of 1622d07f:
1. Perf: every i=2253 refresh ran the whole notifier walk + permission checks +
   QueueEvent under Lock. Now, with nothing deferred (the common case), the refresh is
   the SDK-shaped walk off Lock (Lock only to copy the root notifiers), kept only if no
   deferral episode existed at any moment of it (count 0 before and after, episode
   unchanged); otherwise the cut path also runs and its later replay supersedes. The
   cut path takes ACL/role verdicts off Lock, then one short Lock hold: watermark +
   frozen snapshots of Retain conditions from _alarmConditions (no tree walk) + per-item
   cut and "replay pending" marker; the replay is queued OFF Lock, one event per hold of
   the item gate. While pending, a condition event newer than the cut marks its
   condition so the older frozen entry is dropped rather than following it. A
   concurrent fast-path refresh cancels a pending cut replay of the same item.
   Measured, 3000 retained conditions, longest Lock wait seen by another thread during
   one refresh: 1622d07f 95-106 ms idle / 102-127 ms deferring; now 0-3 ms idle /
   23-32 ms deferring.
2. ACL: a retained condition omitted from the replay for want of a grant is never
   withheld (RefreshCut.RetainedAtCut); only Retain=true events of a condition omitted
   because it was NOT retained are.
3. One gate/cut state per item for its lifetime (ConditionalWeakTable keyed by the
   item): an unsubscribe + resubscribe between refresh and drain keeps the cut.
4. Cuts carry their deferral episode; ClearStaleRefreshCuts runs when the count
   returns to zero, and a stale-episode cut is inert.
5. Dispose guard for the custom refresh (ObjectDisposedException once disposing;
   Dispose waits for refreshes in flight).
6. Docs: a refresh waits at most for one in-progress QueueEvent on the item.

Tests: resubscribe variants, ACL-grant-lands test, pending-replay probe test,
dispose test, 3000-condition Lock-hold measurement with a probe pinning that neither
path queues its replay under Lock; stress invariant tightened (never backwards outside a
refresh; each refresh ends on the newest delivered state) and tolerant of the SDK's own
BadRefreshInProgress overlap refusal. Each new test fails against its targeted mutation.
2026-11-11 07:28:08 -05:00
Joseph Doherty 1622d07f2e fix(opcua): ConditionRefresh on a Server-object item is not overtaken by older deferred condition events (#854)
While a folder subscriber's SDK channel is full, a condition's later events wait in
its #838 deferral queue and reach i=2253 items only when the drain gets to them, off
Lock. A ConditionRefresh in that window replayed the current state, then the older
deferred events followed RefreshEnd (stale state, or a condition the refresh had just
dropped re-added until the newest drained).

- Condition events are reported as ConditionEventSnapshot (an InstanceStateSnapshot
  carrying a report sequence, condition NodeId and Retain); events queued behind a
  deferred report are marked Deferred.
- Server-object refresh (ConditionRefresh and ConditionRefresh2, flag on AND off) now
  runs in RefreshServerObjectItems: watermark, "anything deferred?", the replay and its
  queueing in ONE Lock hold, so the replay is exactly the state at the cut. Per item it
  queues the replay and installs a RefreshCut under the item's gate.
- OnConditionReportEvent holds that gate across "superseded? -> QueueEvent" for
  deferred events only. Withheld from that item alone: events at/below the cut whose
  condition the replay re-sent, or Retain=true events of a condition it omitted; an
  older Retain=false event of an omitted condition is still delivered. Queues, other
  Server-object items and folder items are untouched; refresh never waits for a drain.
- Lock order Lock -> item gate -> SDK item lock, same as a synchronous report.
- Meter otopcua.opcua.condition_events.superseded.
- Folder items keep a documented residual (SDK channel backlog + memoised per-item
  verdict leave no per-event hook).

Tests: ConditionRefreshDeferralWireTests (deterministic overload by holding the folder
item's SDK lock; 6 variants fail before the fix; probe-driven gate test fails with the
gate removed; concurrent reports/refreshes/stall stress test fails before the fix).
2026-11-11 06:37:22 -05:00
Joseph Doherty 7482a88888 fix(opcua): deferred condition events never outlive their condition; per-condition bounded deferral; canonical lockout identity (#838, #844 review)
#838 review of 91e28e87:
1. Ghost events. The deferred report ran the SDK walk off Lock with no
   liveness check, so an event waiting behind a full channel when a deploy
   removed its condition still reached i=2253 subscribers after the NodeDeleted
   (a ghost Retain alarm for ScadaBridge) and folder items. Delivery now walks
   the SDK path itself (OnReportEvent, OnReportEventAsync, inverse notifiers,
   then the Parent as BaseInstanceState does) re-checking before EVERY hop that
   the condition is the live instance; OnConditionReportEvent checks the same,
   which also stops a non-live scripted condition being admitted through its
   old equipment folder (#808). A guard test pins that only NodeState and
   BaseInstanceState define the walk. New wire test removes the condition in
   the same Lock hold as a flood; the flag-off variant fails without the checks.
2. Back-pressure. Deferral is per condition (one condition's events stay
   ordered; others are not held up). Overflow policy: coalesce, newest wins --
   past 1024 waiting per condition or 65,536 total, the oldest not-yet-started
   event is discarded (a condition event carries full state). Warning on
   entering deferral (<=1/min), Information on draining, meters
   otopcua.opcua.condition_events.deferred / .discarded{reason}.
3. Verified by decompiling SDK 2.0.1: the notifier list is snapshotted under the
   node's own lock, MonitoredNode2.Dispose completes its writer (pending writes
   fail with ChannelClosedException, swallowed), and the consumer catches
   per-event exceptions -- no fix needed; documented.
4. ConditionRefresh does not flush deferrals; documented as a residual.

#844 review: DescribeCredential canonicalises the key id (trim, lowercase;
non-hex ids fold into one identity) and the username, since ConfigDbApiKeyStore
matches with SQL Server's case-insensitive, trailing-space-blind `=`.
2026-11-11 04:35:30 -05:00
Joseph Doherty 91e28e87be fix(opcua): condition events never block under the node-manager lock; folder-event Part 3 note (#838)
#838(a): each notifier's SDK MonitoredNode2 drains a bounded channel (4096,
FullMode=Wait) and the synchronous NodeState.ReportEvent blocks when it is
full. Condition events are reported under Lock, and the delivery task takes
Lock on a verdict-cache miss (the SDK's own GetNodeMetadata, flag off too, and
#826's IsNotifierEventVisibleTo). A burst of >4096 events under one Lock hold
therefore deadlocked the node manager -- FolderEventFloodWireTests stalled at
exactly 4097 events with enforcement on AND off (so it predates #826).

ReportConditionEvent now goes through ReportEventWithoutBlocking:
ReportEventAsync completes inline while channels have room (unchanged normal
path); on overflow the report continues asynchronously holding no thread or
lock, and later reports queue behind it so events keep report order. The
deferred work holds only frozen snapshots and drains once Lock is released;
client delivery stays bounded by each item's queue.

#838(b): documented in docs/security.md that Part 3 ReceiveEvents applies to
the event's EventType and SourceNode (the SDK check, kept first), not to the
notifier; our decision is layered on top and non-condition events on a folder
item fail closed under enforcement. The reflection item stays open.
2026-11-11 04:06:28 -05:00
Joseph Doherty ffba75bb93 fix(opcua): credential lockout counts per credential identity, ignores transient denials (#844, #845)
#844: a success cleared the whole per-client count, so a client holding a valid
key could make four guesses at another key id, sign in with its own, and repeat
forever. Failures are now charged to the (client, credential identity) pair --
IOpcUaUserAuthenticator.DescribeCredential, key:<keyId> for API keys -- and to
the client as a whole. A success clears only its own identity's count; the
per-identity threshold locks that identity; a new per-client cap
(OpcUa:CredentialLockout:MaxFailedAttemptsPerClient, default 2 x
MaxFailedAttempts) that a success never resets bounds spraying across key ids
and locks every credential. Slots are bounded on both counts; a waiter whose
identity has room is not held behind one whose identity has none.

#845: (1) store timeouts, miss-budget refusals, store/authenticator exceptions,
an unset pepper and cancellation are reported Transient
(OpcUaUserAuthResult.Unavailable) and released uncounted, so a ConfigDb stall
can no longer lock every keyed client out; the client still sees the same
opaque denial. (2) a full 4096-entry table defers its next prune until the
earliest entry could age out instead of rescanning under the lock per failure.
(3) ApplicationUri deliberately NOT added to the key: on a None channel it is a
free string, so it would let an attacker reset the count per guess --
documented. (4) wire tests: distinct client certificates on a Sign endpoint are
locked out separately; the ApplicationConfigPath branch keeps the SDK lockout
off (falsified by removing the loaded-branch disable).
2026-11-11 03:47:10 -05:00
Joseph Doherty 2314a53842 fix(opcua): parallel UserName activations wait for a slot instead of being refused (#833)
A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
2026-11-11 02:43:38 -05:00
Joseph Doherty 61b9adeb9c Merge branch 'master' into fix/832-docker-dev-batch 2026-11-11 02:32:42 -05:00
Joseph Doherty 5bfe8386e6 Merge fix/826-folder-event-acl 2026-11-11 02:25:44 -05:00
Joseph Doherty 489664d105 fix(acl): folder event verdict invalidation reaches orphaned items, decides on the live instance, skips ACL-off; alarm-bearing reference map (#826 review)
1. Orphaned subscriptions (session closed without deleting subs) have Session == null, so the public
   MonitoredNode2.InvalidatePermissionCacheForSession never reached their items: a cached allow survived a
   deploy, the moved alarm's events were queued and delivered on TransferSubscriptions. Each notifier's
   cache is now cleared whole through the SDK's private MonitoredNode2.InvalidatePermissionCaches
   (reflection, guard-tested; fallback = per-session drop + Remove/Add of session-less items).
2. The verdict is decided on the condition LIVE under the event's NodeId, not the event's own instance:
   the SDK key has no instance identity, so a replaced instance's late event cached a deny its successor
   inherited until the next invalidation.
3. Invalidation is skipped while enforcement is off (forced across an on/off authorizer transition) and is
   one O(cache) clear per node instead of a whole-cache scan per item.
4. TagReferencingEquipment carries alarm-bearing raw tags only (TagConfigIntent.Alarm); the snapshot adopts
   an OrdinalIgnoreCase set instead of copying it again.

Tests (each fails with its fix reverted): FolderEventVerdictInvalidationTests (orphan + deploy + transfer;
replaced instance's late event; ACL-off skip; SDK private-method guard), DeploymentArtifactScopePathTests
(alarm-bearing projection).
2026-11-11 02:25:24 -05:00
Joseph Doherty 8e1e73f93c fix(acl): per-event visibility for direct folder event items; generation-checked native wiring (#826)
Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.

- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
  per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
  legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
  ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
  authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
  UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
  counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
  as reference variables (an Area named like its equipment's id no longer narrows them).

Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
2026-11-11 01:39:06 -05:00
Joseph Doherty 56e642239f test(opcua): i=11201 advertises DurationGood/DurationBad on the SQL backends (#820)
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:30:51 -05:00
Joseph Doherty e7b485c0a2 feat(historian): serve DurationGood/DurationBad on the SQL backends; pin the #821 late-start facts (#820, #821)
#820: SqlServer + QuestDB now serve Part 13 DurationGood / DurationBad from the
same Good / Bad region totals TimeWeightedAggregator already computes for
PercentGood / PercentBad — reported in milliseconds (OPC UA Duration, the SDK's
unit), Uncertain time in neither (Mantis 0006166), same BadNoData / status /
Partial rules. AggregateFamilies.Served grows 17 -> 19, so i=11201 and the
up-front refusal follow automatically; Gateway still refuses both (explicit
served set, unchanged). Client.Shared AggregateType / mapper / CLI gain both.
The #796 oracle answers DurationGood through the Good-only subclass as well.
QualityMix conformance asserts both directly (Q and QP, hand values, ms, and
= PercentGood x interval), replaces the "refused up front" test, and adds
Duration* to the forward/reverse/truncated oracle comparisons.

#821 (facts only, no decision): SdkAggregateParityTests pins an Uncertain-first
late-start interval (QP over [0,20), both directions) against ours (Part 13
Total 163.96, TimeAverage 10.93), the frozen 1.5.378.182 calculators (188.96,
9.448), SDK 2.0.1's stock calculators (188.96, 9.448) and a Good-first control
(all 163.96); LiveAggregateLateStartFactsTests pins the same through the booted
server's runtime AggregateManager (live AggregateFilter) incl. DurationGood
15000 / PercentGood 75 there vs 8000 / 40 in HistoryRead (#809). QualityMix
adds the reverse late-start variant (reverse TW pin + reverse oracle windows).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:28:54 -05:00
Joseph Doherty 40969e5c4b fix(opcua): failed sign-ins no longer lock a client out of anonymous sessions (#833)
OPC Foundation SDK 2.0.1's SessionManager lockout refused EVERY
activation (Anonymous included, before the token is read) from a client
with 5 failed identity validations in 60 s, for 5 minutes, keyed on cert
thumbprint else peer IP. Disable it (MaxFailedAuthenticationAttempts=0
on built and loaded configs) and enforce FailedCredentialLockout in the
identity-registry adapter instead: UserName activations only, keyed on
thumbprint+peer together, same 5/60s/300s defaults, configurable via
OpcUa:CredentialLockout.
2026-11-11 01:23:33 -05:00
Joseph Doherty e39a125069 fix(acl): close the #808 review findings — reference variables, owner folder chain, NUL keys, unknown ids (#808)
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
   equipment stayed readable/writable under the OLD names' grants: they now
   resolve as ReferenceVariable and are authorized at their split path only
   while it equals their live equipment folder's placement (live chain ==
   generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
   to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
   so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
   client ids disjoint from the NUL-prefixed resolved-scope keys (a client
   could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
   Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
   split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
   removed UNS folders/vtags/conditions — documented); 4-segment
   reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.

Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
2026-11-10 23:44:11 -05:00
Joseph Doherty af5c9744b7 fix(acl): place opaque-id UNS folders, virtual tags and scripted conditions for every operation (#808)
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.

- The generation carries UnsFolderScopes (folderId -> path + id chain), built
  by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
  two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
  ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
  decision cache, which now caches the walk keyed on the resolved scope.
  Folders require live chain == generation chain (a moved equipment is denied
  under old and new line until the rebuild). Owned nodes (vtags, conditions,
  children) get owner path + a reserved segment, so Tag grants and their
  Browse transit never expose them. Conditions share TryPlaceScriptedCondition
  with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
  condition alone, so a moved alarm cannot reach its old owner there.

Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
2026-11-10 23:12:46 -05:00
Joseph Doherty 4620e542e8 fix(acl): require the live scripted-alarm owner to match the generation's deployed owner (#797)
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).

The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.

Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
2026-11-10 21:42:03 -05:00
Joseph Doherty 3d1b86b451 fix(acl): authorize scripted alarm commands at their owning equipment's scope (#797)
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.

- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
  EquipmentId it was materialised under (only when it hangs under that folder);
  dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
  same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
  [uns, Area, Line, Equipment]) decoded from the artifact by the same
  AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
  generation per call (uncached) and evaluates at the owner path; unbound,
  replaced or unplaceable owners deny under every grant. No id-split or
  realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
  NodeIds and AlarmCommand.AlarmId are unchanged.

Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
2026-11-10 21:23:57 -05:00