fix(ablegacy): review fixes - one family-aware address authority in Contracts, deploy gate + editor check, malformed address -> BadNodeIdUnknown warned once, probe normalised, octal/migration docs (#244 #245 #247)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -97,9 +97,21 @@ physical inputs and may reject the write.
|
||||
bit 7 and `I:017/17` is bit 15. Only `I`/`O` on PLC-5 (`OctalIoAddressing` on the family profile) — SLC,
|
||||
MicroLogix and Logix-PCCC stay decimal, and PLC-5 `N`/`B`/... files stay decimal. The record stores decimal and
|
||||
`ToLibplctagName()` **emits decimal**, so the libplctag `name=` string and the string the native transport
|
||||
re-parses carry identical numbers. ⚠️ *Unverified:* whether libplctag itself reads PLC-5 I/O indices as octal
|
||||
when handed the raw RSLogix text was not checked (no libplctag source/PLC here); the driver therefore never
|
||||
hands it octal text. Native PLC-5 is N-file read-only anyway, so I/O never reaches the native wire.
|
||||
re-parses carry identical numbers. This is not a double conversion: libplctag's `pccc.c`
|
||||
(`parse_pccc_elem_num` / `parse_pccc_bit_num`) parses decimal numerals only (a FIXME there says octal is
|
||||
unsupported), so the driver must convert. Pinned by `Plc5_io_indices_are_octal` (`I:017/17` -> `I:15/15`).
|
||||
The connectivity-probe address is normalised the same way.
|
||||
- ⚠️ **Behaviour change / migration.** Before this change a PLC-5 `I:`/`O:` address was passed to libplctag as
|
||||
written, i.e. read as **decimal**. An address copied from RSLogix in octal (e.g. `I:017`) therefore read the
|
||||
wrong word, and an authored decimal such as `I:1/12` now means bit 10 (octal 12). A previously "working"
|
||||
address containing the digits 8 or 9 (`I:018`, `O:1/9`) is no longer valid on PLC-5. Re-author any PLC-5
|
||||
I/O tags in RSLogix octal. Such a tag is refused (see below), never silently misread.
|
||||
- **A malformed / family-invalid address** (also: a function-file letter off MicroLogix) reads and writes
|
||||
`BadNodeIdUnknown` for that tag only, creates no runtime, leaves driver health alone, and logs **one**
|
||||
Warning per tag. The same check (`AbLegacyAddress.Validate`) runs in the AdminUI tag editor (family-independent:
|
||||
rejects only what *no* family accepts) and the deploy gate (`EquipmentTagConfigInspector`, using the device's
|
||||
`DeviceConfig.PlcFamily`, absent = SLC 500, unrecognised = unknown) — so `I:018` on a PLC-5 device warns at
|
||||
deploy (an error under `TagConfigValidationMode.Error`), and the editor is never stricter than the gate.
|
||||
- **MicroLogix function files (#245).** `RTC`, `HSC`, `DLS`, `MMI`, `PTO`, `PWM`, `STI`, `EII`, `IOS`, `BHI`
|
||||
(single fixed instance — no file number — with a `.SUBELEMENT`; no bit index) parse on MicroLogix devices only.
|
||||
`AbLegacyFunctionFile.SubElementType` carries the sub-element catalogue (flags → Boolean, words → Int32; unknown
|
||||
|
||||
+36
-3
@@ -49,7 +49,10 @@ public sealed record AbLegacyAddress(
|
||||
|
||||
/// <summary>
|
||||
/// Converts the address to the libplctag library address format. Numeric indices are always
|
||||
/// emitted <b>decimal</b> (a PLC-5 octal I/O address is normalised at parse time). An indirect
|
||||
/// emitted <b>decimal</b> (a PLC-5 octal I/O address is normalised at parse time). This is correct, not a
|
||||
/// double conversion: libplctag's <c>pccc.c</c> (<c>parse_pccc_elem_num</c> / <c>parse_pccc_bit_num</c>) parses
|
||||
/// decimal numerals only (a FIXME there notes octal is unsupported), so handing it the RSLogix octal text would
|
||||
/// read the wrong word. An indirect
|
||||
/// address re-emits its bracket form, which neither transport accepts — check
|
||||
/// <see cref="IsIndirect"/> first.
|
||||
/// </summary>
|
||||
@@ -86,6 +89,36 @@ public sealed record AbLegacyAddress(
|
||||
return ParseCore(value.Trim(), profile, allowIndirect: true);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The single authoring / deploy-gate / runtime address check. With a known <paramref name="family"/> the
|
||||
/// address must parse for that family; with an unknown one (<see langword="null"/>) it must parse for at
|
||||
/// least one family, so a caller that cannot see the device never rejects what the runtime would accept.
|
||||
/// </summary>
|
||||
/// <param name="address">The authored address text.</param>
|
||||
/// <param name="family">The device's PLC family, or <see langword="null"/> when it is not known.</param>
|
||||
/// <returns>An error message, or <see langword="null"/> when the address is acceptable.</returns>
|
||||
public static string? Validate(string? address, AbLegacyPlcFamily? family)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(address)) return "Address is required.";
|
||||
if (family is { } f)
|
||||
{
|
||||
if (TryParse(address, f) is not null) return null;
|
||||
var hint = f == AbLegacyPlcFamily.Plc5 && TryParse(address, AbLegacyPlcFamily.Slc500) is not null
|
||||
? " (PLC-5 I:/O: word and bit indices are octal - 8 and 9 are invalid)"
|
||||
: IsFunctionLetterPrefix(address) ? " (function files are MicroLogix-only)" : "";
|
||||
return $"'{address}' is not a valid address for a {f} device{hint}.";
|
||||
}
|
||||
foreach (var candidate in Enum.GetValues<AbLegacyPlcFamily>())
|
||||
if (TryParse(address, candidate) is not null) return null;
|
||||
return $"'{address}' is not a valid PCCC file address for any PLC family.";
|
||||
}
|
||||
|
||||
private static bool IsFunctionLetterPrefix(string address)
|
||||
{
|
||||
var colon = address.IndexOf(':');
|
||||
return colon > 0 && IsFunctionFileLetter(address[..colon].Trim().ToUpperInvariant());
|
||||
}
|
||||
|
||||
private static AbLegacyAddress? ParseCore(string src, AbLegacyPlcFamilyProfile? profile, bool allowIndirect)
|
||||
{
|
||||
// BitIndex: trailing /N outside any bracketed inner address. The numeric parse is deferred until the
|
||||
@@ -254,9 +287,9 @@ public sealed record AbLegacyAddress(
|
||||
|
||||
/// <summary>
|
||||
/// MicroLogix 1100/1400 function-file prefixes — each a single fixed instance with a sub-element
|
||||
/// catalogue (<see cref="AbLegacyFunctionFile"/>).
|
||||
/// catalogue (<c>AbLegacyFunctionFile</c>).
|
||||
/// </summary>
|
||||
internal static bool IsFunctionFileLetter(string letter) => letter switch
|
||||
public static bool IsFunctionFileLetter(string letter) => letter switch
|
||||
{
|
||||
"RTC" or "HSC" or "DLS" or "MMI" or "PTO" or "PWM" or "STI" or "EII" or "IOS" or "BHI" => true,
|
||||
_ => false,
|
||||
+27
-2
@@ -1,3 +1,4 @@
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
|
||||
using System.Text.Json;
|
||||
using System.Text.Json.Nodes;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
@@ -122,6 +123,12 @@ public static class AbLegacyTagDefinitionFactory
|
||||
/// The RawPath handed to <see cref="FromTagConfig"/> during inspection — the mapper only copies it
|
||||
/// onto <see cref="AbLegacyTagDefinition.Name"/> and never validates it.
|
||||
/// </summary>
|
||||
private static bool IsIndirectFor(string address, AbLegacyPlcFamily? family)
|
||||
{
|
||||
if (family is { } f) return AbLegacyAddress.TryParse(address, f)?.IsIndirect == true;
|
||||
return Enum.GetValues<AbLegacyPlcFamily>().Any(c => AbLegacyAddress.TryParse(address, c)?.IsIndirect == true);
|
||||
}
|
||||
|
||||
private const string InspectionRawPath = "(inspect)";
|
||||
|
||||
/// <summary>
|
||||
@@ -145,7 +152,18 @@ public static class AbLegacyTagDefinitionFactory
|
||||
/// </remarks>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference)
|
||||
public static IReadOnlyList<string> Inspect(string reference) => Inspect(reference, family: null);
|
||||
|
||||
/// <summary>
|
||||
/// <see cref="Inspect(string)"/> plus the family-aware address check (<see cref="AbLegacyAddress.Validate"/>,
|
||||
/// the same authority the driver runtime uses). <paramref name="family"/> is the tag's device's PLC family, or
|
||||
/// <see langword="null"/> when unknown (then only an address no family accepts is flagged). An indirect
|
||||
/// address parses but the runtime always answers it <c>BadNotSupported</c>, so it is warned about too.
|
||||
/// </summary>
|
||||
/// <param name="reference">The equipment tag's TagConfig JSON.</param>
|
||||
/// <param name="family">The owning device's PLC family, when known.</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string reference, AbLegacyPlcFamily? family)
|
||||
{
|
||||
var warnings = new List<string>();
|
||||
// Gitea #556 item 1: the framing check TRIMS FIRST. FromTagConfig hands the blob straight to
|
||||
@@ -157,7 +175,14 @@ public static class AbLegacyTagDefinitionFactory
|
||||
|
||||
// The accept gate: whatever the driver reads draws nothing. The RAW reference is handed to the
|
||||
// mapper — the driver reads the stored blob, not a trimmed copy of it.
|
||||
if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
|
||||
if (FromTagConfig(reference, InspectionRawPath, out var accepted))
|
||||
{
|
||||
if (AbLegacyAddress.Validate(accepted.Address, family) is { } addressError)
|
||||
warnings.Add($"AbLegacy tag address: {addressError} The driver reads this tag as BadNodeIdUnknown.");
|
||||
else if (IsIndirectFor(accepted.Address, family))
|
||||
warnings.Add($"AbLegacy address '{accepted.Address}' is indirect; indirect addressing is not supported and the tag reads BadNotSupported.");
|
||||
return warnings;
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
|
||||
@@ -357,7 +357,14 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
{
|
||||
// Indirect addresses (N7:[N7:0]) parse but are not resolved at runtime (#247) — answer the
|
||||
// refusal before a runtime is created for a name neither transport can encode.
|
||||
if (AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily) is { IsIndirect: true })
|
||||
var preParsed = AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily);
|
||||
if (preParsed is null)
|
||||
{
|
||||
WarnMalformedOnce(device, def);
|
||||
results[i] = new DataValueSnapshot(null, AbLegacyStatusMapper.BadNodeIdUnknown, null, now);
|
||||
continue;
|
||||
}
|
||||
if (preParsed.IsIndirect)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, AbLegacyStatusMapper.BadNotSupported, null, now);
|
||||
continue;
|
||||
@@ -465,8 +472,16 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
{
|
||||
var parsed = AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily);
|
||||
|
||||
// A malformed address is a config error, not a comms fault (BadNodeIdUnknown, warned once per tag).
|
||||
if (parsed is null)
|
||||
{
|
||||
WarnMalformedOnce(device, def);
|
||||
results[i] = new WriteResult(AbLegacyStatusMapper.BadNodeIdUnknown);
|
||||
continue;
|
||||
}
|
||||
|
||||
// Indirect addressing is parse-only (#247): refuse before any runtime or RMW read is created.
|
||||
if (parsed is { IsIndirect: true })
|
||||
if (parsed.IsIndirect)
|
||||
{
|
||||
results[i] = new WriteResult(AbLegacyStatusMapper.BadNotSupported);
|
||||
continue;
|
||||
@@ -625,7 +640,10 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
Port: state.ParsedAddress.Port,
|
||||
CipPath: state.EffectiveCipPath,
|
||||
LibplctagPlcAttribute: state.Profile.LibplctagPlcAttribute,
|
||||
TagName: _options.Probe.ProbeAddress!,
|
||||
// Normalised exactly like tag paths (PLC-5 octal I/O -> decimal); an unparseable probe address is passed through
|
||||
// so the transport reports the failure as it always did.
|
||||
TagName: AbLegacyAddress.TryParse(_options.Probe.ProbeAddress, state.Options.PlcFamily)?.ToLibplctagName()
|
||||
?? _options.Probe.ProbeAddress!,
|
||||
Timeout: _options.Probe.Timeout);
|
||||
|
||||
IAbLegacyTagRuntime? probeRuntime = null;
|
||||
@@ -873,6 +891,19 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
keep();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A tag whose address does not parse for its device's PLC family (e.g. a PLC-5 octal I/O digit 8/9, a
|
||||
/// function-file letter off MicroLogix) is a configuration error: answered <c>BadNodeIdUnknown</c> with the
|
||||
/// handle/health untouched, and warned once per tag so a polled tag does not flood the log.
|
||||
/// </summary>
|
||||
private void WarnMalformedOnce(DeviceState device, AbLegacyTagDefinition def)
|
||||
{
|
||||
if (!device.MalformedAddressLogged.TryAdd(def.Name, 0)) return;
|
||||
_logger.LogWarning(
|
||||
"AbLegacy tag address is not valid for the device's PLC family. Driver={DriverInstanceId} Device={DeviceHostAddress} Reference={Reference} Address={Address} Family={Family}",
|
||||
_driverInstanceId, def.DeviceHostAddress, def.Name, def.Address, device.Options.PlcFamily);
|
||||
}
|
||||
|
||||
/// <summary>The create parameters for a tag's own runtime — shared by creation and the write-refusal check, so
|
||||
/// the refusal is asked about exactly the runtime a write would otherwise create.</summary>
|
||||
private AbLegacyTagCreateParams CreateParamsFor(DeviceState device, AbLegacyTagDefinition def, AbLegacyAddress parsed) =>
|
||||
@@ -1105,6 +1136,9 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
/// </summary>
|
||||
public bool FirstNonZeroStatusLogged { get; set; }
|
||||
|
||||
/// <summary>Tags already warned about for a malformed address (once-per-tag log).</summary>
|
||||
public System.Collections.Concurrent.ConcurrentDictionary<string, byte> MalformedAddressLogged { get; } = new();
|
||||
|
||||
/// <summary>
|
||||
/// Disposes all cached tag runtimes.
|
||||
/// </summary>
|
||||
|
||||
@@ -68,8 +68,11 @@ public sealed class AbLegacyTagConfigModel
|
||||
if (TagConfigJson.DescribeInvalidEnum<AbLegacyDataType>(_bag, "dataType") is { } dtError)
|
||||
return dtError;
|
||||
|
||||
if (string.IsNullOrWhiteSpace(Address))
|
||||
return "Address is required.";
|
||||
// The editor cannot see the device's PLC family, so it checks only what no family accepts (the same
|
||||
// AbLegacyAddress authority the deploy gate and runtime use) — never stricter than the gate, which adds the
|
||||
// family-specific verdict (PLC-5 octal I/O, MicroLogix-only function files).
|
||||
if (AbLegacyAddress.Validate(Address, family: null) is { } addressError)
|
||||
return addressError;
|
||||
|
||||
// DELIBERATELY STRICTER THAN THE RUNTIME, and re-confirmed as such by the Gitea #554 survey — do not
|
||||
// "align" it. PCCC data-file elements are limited to AbLegacyArray.MaxElements (256). The reader
|
||||
|
||||
@@ -262,12 +262,16 @@ public sealed class AdminOperationsActor : ReceiveActor
|
||||
var driverByDevice = draft.Devices
|
||||
.GroupBy(d => d.DeviceId, StringComparer.Ordinal)
|
||||
.ToDictionary(g => g.Key, g => g.First().DriverInstanceId, StringComparer.Ordinal);
|
||||
var deviceConfigById = draft.Devices
|
||||
.GroupBy(d => d.DeviceId, StringComparer.Ordinal)
|
||||
.ToDictionary(g => g.Key, g => g.First().DeviceConfig, StringComparer.Ordinal);
|
||||
var tagConfigWarnings = new List<(string TagId, string Text)>();
|
||||
foreach (var t in draft.Tags)
|
||||
{
|
||||
if (!driverByDevice.TryGetValue(t.DeviceId, out var driverInstanceId)) continue;
|
||||
if (!driverTypeById.TryGetValue(driverInstanceId, out var driverType)) continue;
|
||||
foreach (var w in EquipmentTagConfigInspector.Inspect(driverType, t.TagConfig))
|
||||
foreach (var w in EquipmentTagConfigInspector.Inspect(
|
||||
driverType, t.TagConfig, deviceConfigById.GetValueOrDefault(t.DeviceId)))
|
||||
tagConfigWarnings.Add((t.TagId, $"tag '{t.TagId}': {w}"));
|
||||
}
|
||||
if (tagConfigWarnings.Count > 0)
|
||||
|
||||
+42
@@ -1,6 +1,7 @@
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbCip;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Calculation;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
@@ -78,6 +79,47 @@ public static class EquipmentTagConfigInspector
|
||||
return Inspectors.TryGetValue(driverType, out var inspect) ? inspect(tagConfig) : Array.Empty<string>();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// <see cref="Inspect(string?, string?)"/> with the owning device's <c>DeviceConfig</c>, so a driver whose
|
||||
/// address grammar depends on the device (AbLegacy: the <c>PlcFamily</c>) is checked against the family the
|
||||
/// runtime will use. Other drivers ignore the device config. A missing family key is the runtime default
|
||||
/// (SLC 500); an unrecognised value is "unknown" and only the family-independent check applies — the gate
|
||||
/// is never stricter than the runtime.
|
||||
/// </summary>
|
||||
/// <param name="driverType">The bound driver's <c>DriverType</c>.</param>
|
||||
/// <param name="tagConfig">The equipment tag's <c>TagConfig</c> JSON.</param>
|
||||
/// <param name="deviceConfig">The owning device's <c>DeviceConfig</c> JSON (may be null).</param>
|
||||
/// <returns>The warnings; empty when clean.</returns>
|
||||
public static IReadOnlyList<string> Inspect(string? driverType, string? tagConfig, string? deviceConfig)
|
||||
{
|
||||
if (string.IsNullOrEmpty(driverType) || tagConfig is null) return Array.Empty<string>();
|
||||
if (string.Equals(driverType, DriverTypeNames.AbLegacy, StringComparison.OrdinalIgnoreCase))
|
||||
return AbLegacyTagDefinitionFactory.Inspect(tagConfig, ReadAbLegacyFamily(deviceConfig));
|
||||
return Inspect(driverType, tagConfig);
|
||||
}
|
||||
|
||||
private static AbLegacyPlcFamily? ReadAbLegacyFamily(string? deviceConfig)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(deviceConfig)) return AbLegacyPlcFamily.Slc500;
|
||||
try
|
||||
{
|
||||
using var doc = System.Text.Json.JsonDocument.Parse(deviceConfig);
|
||||
if (doc.RootElement.ValueKind != System.Text.Json.JsonValueKind.Object) return AbLegacyPlcFamily.Slc500;
|
||||
foreach (var prop in doc.RootElement.EnumerateObject())
|
||||
{
|
||||
if (!string.Equals(prop.Name, "PlcFamily", StringComparison.OrdinalIgnoreCase)) continue;
|
||||
var raw = prop.Value.ValueKind == System.Text.Json.JsonValueKind.String ? prop.Value.GetString() : null;
|
||||
if (string.IsNullOrWhiteSpace(raw)) return AbLegacyPlcFamily.Slc500;
|
||||
return Enum.TryParse<AbLegacyPlcFamily>(raw, ignoreCase: true, out var f) && Enum.IsDefined(f) ? f : null;
|
||||
}
|
||||
return AbLegacyPlcFamily.Slc500;
|
||||
}
|
||||
catch (System.Text.Json.JsonException)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Whether the given driver type has a mapped inspector.</summary>
|
||||
/// <param name="driverType">The bound driver's <c>DriverType</c>.</param>
|
||||
/// <returns><see langword="true"/> when an inspector is registered for the driver type.</returns>
|
||||
|
||||
+68
@@ -249,4 +249,72 @@ public sealed class AbLegacyFamilyAddressingTests
|
||||
ex.Status.ShouldBe(AbStatus.Unsupported);
|
||||
ex.Message.ShouldContain(why, Case.Insensitive);
|
||||
}
|
||||
|
||||
private sealed class CapturingLogger : Microsoft.Extensions.Logging.ILogger<AbLegacyDriver>
|
||||
{
|
||||
public readonly System.Collections.Concurrent.ConcurrentQueue<string> Warnings = new();
|
||||
public IDisposable? BeginScope<TState>(TState state) where TState : notnull => null;
|
||||
public bool IsEnabled(Microsoft.Extensions.Logging.LogLevel logLevel) => true;
|
||||
public void Log<TState>(Microsoft.Extensions.Logging.LogLevel level, Microsoft.Extensions.Logging.EventId id,
|
||||
TState state, Exception? ex, Func<TState, Exception?, string> f)
|
||||
{
|
||||
if (level == Microsoft.Extensions.Logging.LogLevel.Warning) Warnings.Enqueue(f(state, ex));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A PLC-5 address that no longer parses (the pre-octal-era decimal 8/9 digit) is a config error: BadNodeIdUnknown on
|
||||
/// read and write, no runtime created, health untouched, and ONE warning per tag however often it is polled.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Malformed_address_is_BadNodeIdUnknown_warned_once_and_never_throws()
|
||||
{
|
||||
var factory = new FakeAbLegacyTagFactory();
|
||||
var logger = new CapturingLogger();
|
||||
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
|
||||
{
|
||||
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0", AbLegacyPlcFamily.Plc5)],
|
||||
RawTags = AbLegacyRawTags.Entries(
|
||||
new AbLegacyTagDefinition("Bad", "ab://10.0.0.5/1,0", "I:018", AbLegacyDataType.Int, Writable: true),
|
||||
new AbLegacyTagDefinition("Good", "ab://10.0.0.5/1,0", "N7:1", AbLegacyDataType.Int)),
|
||||
Probe = new AbLegacyProbeOptions { Enabled = false },
|
||||
}, "drv-1", factory, logger);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
factory.Customise = p => new FakeAbLegacyTag(p) { Value = 1 };
|
||||
|
||||
var first = await drv.ReadAsync(["Bad", "Good"], CancellationToken.None);
|
||||
var second = await drv.ReadAsync(["Bad"], CancellationToken.None);
|
||||
var write = await drv.WriteAsync([new WriteRequest("Bad", 1)], CancellationToken.None);
|
||||
|
||||
first[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
|
||||
second[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
|
||||
write[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
|
||||
first[1].StatusCode.ShouldBe(AbLegacyStatusMapper.Good); // positive control: the refusal is per tag
|
||||
factory.Tags.Keys.ShouldNotContain(k => k.StartsWith("I:"));
|
||||
logger.Warnings.Count(w => w.Contains("not valid for the device's PLC family") && w.Contains("I:018")).ShouldBe(1);
|
||||
}
|
||||
|
||||
/// <summary>The connectivity-probe address is normalised like tag paths (PLC-5 octal I/O handed over decimal).</summary>
|
||||
[Fact]
|
||||
public async Task Probe_address_is_normalised_like_tag_paths()
|
||||
{
|
||||
var factory = new FakeAbLegacyTagFactory();
|
||||
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
|
||||
{
|
||||
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0", AbLegacyPlcFamily.Plc5)],
|
||||
Probe = new AbLegacyProbeOptions
|
||||
{
|
||||
Enabled = true, Interval = TimeSpan.FromMilliseconds(50), Timeout = TimeSpan.FromMilliseconds(200),
|
||||
ProbeAddress = "I:017",
|
||||
},
|
||||
}, "drv-1", factory);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var deadline = DateTime.UtcNow.AddSeconds(5);
|
||||
while (!factory.Tags.ContainsKey("I:15") && DateTime.UtcNow < deadline) await Task.Delay(20);
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
|
||||
factory.Tags.ContainsKey("I:15").ShouldBeTrue();
|
||||
factory.Tags.ContainsKey("I:017").ShouldBeFalse();
|
||||
}
|
||||
}
|
||||
|
||||
@@ -0,0 +1,55 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.AdminUI.Uns.TagEditors;
|
||||
using ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.AdminUI.Tests.Uns;
|
||||
|
||||
/// <summary>#244/#245/#247: one address authority (AbLegacyAddress.Validate) behind the editor and the deploy gate.</summary>
|
||||
public sealed class AbLegacyFamilyAddressGateTests
|
||||
{
|
||||
private static string Cfg(string address) => "{\"address\":\"" + address + "\",\"dataType\":\"Int\"}";
|
||||
|
||||
[Theory]
|
||||
[InlineData("{\"PlcFamily\":\"Plc5\"}", "I:018", true)] // octal 8 on PLC-5
|
||||
[InlineData("{\"PlcFamily\":\"Plc5\"}", "I:017/07", false)]
|
||||
[InlineData("{\"PlcFamily\":\"Slc500\"}", "I:018", false)] // control: decimal on SLC
|
||||
[InlineData("{\"plcFamily\":\"plc5\"}", "I:018", true)] // key + value case-insensitive
|
||||
[InlineData("{\"PlcFamily\":\"Slc500\"}", "RTC:0.HR", true)] // function file off MicroLogix
|
||||
[InlineData("{\"PlcFamily\":\"MicroLogix\"}", "RTC:0.HR", false)]
|
||||
[InlineData(null, "RTC:0.HR", true)] // absent family = runtime default SLC 500
|
||||
[InlineData("{\"PlcFamily\":\"Bogus\"}", "I:018", false)] // unknown family: never stricter than the runtime
|
||||
[InlineData("{\"PlcFamily\":\"Slc500\"}", "Q9:0", true)]
|
||||
public void Gate_checks_the_address_against_the_device_family(string? deviceConfig, string address, bool warns)
|
||||
{
|
||||
var w = EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg(address), deviceConfig);
|
||||
(w.Count > 0).ShouldBe(warns, string.Join("; ", w));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Gate_warns_about_indirect_addresses_which_never_read()
|
||||
{
|
||||
EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg("N7:[N7:0]"), "{\"PlcFamily\":\"Slc500\"}")
|
||||
.ShouldContain(x => x.Contains("indirect"));
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData("N7:0", null)]
|
||||
[InlineData("I:018", null)] // family unknown to the editor: another family accepts it
|
||||
[InlineData("RTC:0.HR", null)] // MicroLogix accepts it
|
||||
[InlineData("Q9:0", "any PLC family")]
|
||||
public void Editor_validates_only_the_family_independent_shape(string address, string? error)
|
||||
{
|
||||
var result = AbLegacyTagConfigModel.FromJson(Cfg(address)).Validate();
|
||||
if (error is null) result.ShouldBeNull(); else result!.ShouldContain(error);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Editor_is_never_stricter_than_the_gate()
|
||||
{
|
||||
const string address = "Q9:0";
|
||||
AbLegacyTagConfigModel.FromJson(Cfg(address)).Validate().ShouldNotBeNull();
|
||||
EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg(address), null).ShouldNotBeEmpty();
|
||||
}
|
||||
}
|
||||
@@ -346,7 +346,7 @@ public sealed class RawTagConfigGateTests
|
||||
public void A_browse_committed_config_passes_the_gate(string driverType)
|
||||
{
|
||||
var tagConfig = RawBrowseCommitMapper.BuildTagConfig(
|
||||
driverType, "SomeAddress", BrowseFieldsFor(driverType));
|
||||
driverType, driverType == DriverTypeNames.AbLegacy ? "N7:0" : "SomeAddress", BrowseFieldsFor(driverType));
|
||||
|
||||
TagConfigValidator.Validate(driverType, tagConfig).ShouldBeNull(
|
||||
$"browse-commit for {driverType} must not author a config the import refuses");
|
||||
|
||||