diff --git a/docs/drivers/AbLegacy.md b/docs/drivers/AbLegacy.md
index fbe030e6..09b46101 100644
--- a/docs/drivers/AbLegacy.md
+++ b/docs/drivers/AbLegacy.md
@@ -97,9 +97,21 @@ physical inputs and may reject the write.
bit 7 and `I:017/17` is bit 15. Only `I`/`O` on PLC-5 (`OctalIoAddressing` on the family profile) — SLC,
MicroLogix and Logix-PCCC stay decimal, and PLC-5 `N`/`B`/... files stay decimal. The record stores decimal and
`ToLibplctagName()` **emits decimal**, so the libplctag `name=` string and the string the native transport
- re-parses carry identical numbers. ⚠️ *Unverified:* whether libplctag itself reads PLC-5 I/O indices as octal
- when handed the raw RSLogix text was not checked (no libplctag source/PLC here); the driver therefore never
- hands it octal text. Native PLC-5 is N-file read-only anyway, so I/O never reaches the native wire.
+ re-parses carry identical numbers. This is not a double conversion: libplctag's `pccc.c`
+ (`parse_pccc_elem_num` / `parse_pccc_bit_num`) parses decimal numerals only (a FIXME there says octal is
+ unsupported), so the driver must convert. Pinned by `Plc5_io_indices_are_octal` (`I:017/17` -> `I:15/15`).
+ The connectivity-probe address is normalised the same way.
+ - ⚠️ **Behaviour change / migration.** Before this change a PLC-5 `I:`/`O:` address was passed to libplctag as
+ written, i.e. read as **decimal**. An address copied from RSLogix in octal (e.g. `I:017`) therefore read the
+ wrong word, and an authored decimal such as `I:1/12` now means bit 10 (octal 12). A previously "working"
+ address containing the digits 8 or 9 (`I:018`, `O:1/9`) is no longer valid on PLC-5. Re-author any PLC-5
+ I/O tags in RSLogix octal. Such a tag is refused (see below), never silently misread.
+ - **A malformed / family-invalid address** (also: a function-file letter off MicroLogix) reads and writes
+ `BadNodeIdUnknown` for that tag only, creates no runtime, leaves driver health alone, and logs **one**
+ Warning per tag. The same check (`AbLegacyAddress.Validate`) runs in the AdminUI tag editor (family-independent:
+ rejects only what *no* family accepts) and the deploy gate (`EquipmentTagConfigInspector`, using the device's
+ `DeviceConfig.PlcFamily`, absent = SLC 500, unrecognised = unknown) — so `I:018` on a PLC-5 device warns at
+ deploy (an error under `TagConfigValidationMode.Error`), and the editor is never stricter than the gate.
- **MicroLogix function files (#245).** `RTC`, `HSC`, `DLS`, `MMI`, `PTO`, `PWM`, `STI`, `EII`, `IOS`, `BHI`
(single fixed instance — no file number — with a `.SUBELEMENT`; no bit index) parse on MicroLogix devices only.
`AbLegacyFunctionFile.SubElementType` carries the sub-element catalogue (flags → Boolean, words → Int32; unknown
diff --git a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyAddress.cs b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyAddress.cs
similarity index 85%
rename from src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyAddress.cs
rename to src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyAddress.cs
index f4363b8c..aac67c41 100644
--- a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyAddress.cs
+++ b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyAddress.cs
@@ -49,7 +49,10 @@ public sealed record AbLegacyAddress(
///
/// Converts the address to the libplctag library address format. Numeric indices are always
- /// emitted decimal (a PLC-5 octal I/O address is normalised at parse time). An indirect
+ /// emitted decimal (a PLC-5 octal I/O address is normalised at parse time). This is correct, not a
+ /// double conversion: libplctag's pccc.c (parse_pccc_elem_num / parse_pccc_bit_num) parses
+ /// decimal numerals only (a FIXME there notes octal is unsupported), so handing it the RSLogix octal text would
+ /// read the wrong word. An indirect
/// address re-emits its bracket form, which neither transport accepts — check
/// first.
///
@@ -86,6 +89,36 @@ public sealed record AbLegacyAddress(
return ParseCore(value.Trim(), profile, allowIndirect: true);
}
+ ///
+ /// The single authoring / deploy-gate / runtime address check. With a known the
+ /// address must parse for that family; with an unknown one () it must parse for at
+ /// least one family, so a caller that cannot see the device never rejects what the runtime would accept.
+ ///
+ /// The authored address text.
+ /// The device's PLC family, or when it is not known.
+ /// An error message, or when the address is acceptable.
+ public static string? Validate(string? address, AbLegacyPlcFamily? family)
+ {
+ if (string.IsNullOrWhiteSpace(address)) return "Address is required.";
+ if (family is { } f)
+ {
+ if (TryParse(address, f) is not null) return null;
+ var hint = f == AbLegacyPlcFamily.Plc5 && TryParse(address, AbLegacyPlcFamily.Slc500) is not null
+ ? " (PLC-5 I:/O: word and bit indices are octal - 8 and 9 are invalid)"
+ : IsFunctionLetterPrefix(address) ? " (function files are MicroLogix-only)" : "";
+ return $"'{address}' is not a valid address for a {f} device{hint}.";
+ }
+ foreach (var candidate in Enum.GetValues())
+ if (TryParse(address, candidate) is not null) return null;
+ return $"'{address}' is not a valid PCCC file address for any PLC family.";
+ }
+
+ private static bool IsFunctionLetterPrefix(string address)
+ {
+ var colon = address.IndexOf(':');
+ return colon > 0 && IsFunctionFileLetter(address[..colon].Trim().ToUpperInvariant());
+ }
+
private static AbLegacyAddress? ParseCore(string src, AbLegacyPlcFamilyProfile? profile, bool allowIndirect)
{
// BitIndex: trailing /N outside any bracketed inner address. The numeric parse is deferred until the
@@ -254,9 +287,9 @@ public sealed record AbLegacyAddress(
///
/// MicroLogix 1100/1400 function-file prefixes — each a single fixed instance with a sub-element
- /// catalogue ().
+ /// catalogue (AbLegacyFunctionFile).
///
- internal static bool IsFunctionFileLetter(string letter) => letter switch
+ public static bool IsFunctionFileLetter(string letter) => letter switch
{
"RTC" or "HSC" or "DLS" or "MMI" or "PTO" or "PWM" or "STI" or "EII" or "IOS" or "BHI" => true,
_ => false,
diff --git a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyTagDefinitionFactory.cs b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyTagDefinitionFactory.cs
index 79b48a1b..1bbfa9af 100644
--- a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyTagDefinitionFactory.cs
+++ b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Contracts/AbLegacyTagDefinitionFactory.cs
@@ -1,3 +1,4 @@
+using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
using System.Text.Json;
using System.Text.Json.Nodes;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
@@ -122,6 +123,12 @@ public static class AbLegacyTagDefinitionFactory
/// The RawPath handed to during inspection — the mapper only copies it
/// onto and never validates it.
///
+ private static bool IsIndirectFor(string address, AbLegacyPlcFamily? family)
+ {
+ if (family is { } f) return AbLegacyAddress.TryParse(address, f)?.IsIndirect == true;
+ return Enum.GetValues().Any(c => AbLegacyAddress.TryParse(address, c)?.IsIndirect == true);
+ }
+
private const string InspectionRawPath = "(inspect)";
///
@@ -145,7 +152,18 @@ public static class AbLegacyTagDefinitionFactory
///
/// The equipment tag's TagConfig JSON.
/// The warnings; empty when clean.
- public static IReadOnlyList Inspect(string reference)
+ public static IReadOnlyList Inspect(string reference) => Inspect(reference, family: null);
+
+ ///
+ /// plus the family-aware address check (,
+ /// the same authority the driver runtime uses). is the tag's device's PLC family, or
+ /// when unknown (then only an address no family accepts is flagged). An indirect
+ /// address parses but the runtime always answers it BadNotSupported, so it is warned about too.
+ ///
+ /// The equipment tag's TagConfig JSON.
+ /// The owning device's PLC family, when known.
+ /// The warnings; empty when clean.
+ public static IReadOnlyList Inspect(string reference, AbLegacyPlcFamily? family)
{
var warnings = new List();
// Gitea #556 item 1: the framing check TRIMS FIRST. FromTagConfig hands the blob straight to
@@ -157,7 +175,14 @@ public static class AbLegacyTagDefinitionFactory
// The accept gate: whatever the driver reads draws nothing. The RAW reference is handed to the
// mapper — the driver reads the stored blob, not a trimmed copy of it.
- if (FromTagConfig(reference, InspectionRawPath, out _)) return warnings;
+ if (FromTagConfig(reference, InspectionRawPath, out var accepted))
+ {
+ if (AbLegacyAddress.Validate(accepted.Address, family) is { } addressError)
+ warnings.Add($"AbLegacy tag address: {addressError} The driver reads this tag as BadNodeIdUnknown.");
+ else if (IsIndirectFor(accepted.Address, family))
+ warnings.Add($"AbLegacy address '{accepted.Address}' is indirect; indirect addressing is not supported and the tag reads BadNotSupported.");
+ return warnings;
+ }
try
{
diff --git a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyDriver.cs b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyDriver.cs
index f6315c78..89b78f40 100644
--- a/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyDriver.cs
+++ b/src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy/AbLegacyDriver.cs
@@ -357,7 +357,14 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
{
// Indirect addresses (N7:[N7:0]) parse but are not resolved at runtime (#247) — answer the
// refusal before a runtime is created for a name neither transport can encode.
- if (AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily) is { IsIndirect: true })
+ var preParsed = AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily);
+ if (preParsed is null)
+ {
+ WarnMalformedOnce(device, def);
+ results[i] = new DataValueSnapshot(null, AbLegacyStatusMapper.BadNodeIdUnknown, null, now);
+ continue;
+ }
+ if (preParsed.IsIndirect)
{
results[i] = new DataValueSnapshot(null, AbLegacyStatusMapper.BadNotSupported, null, now);
continue;
@@ -465,8 +472,16 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
{
var parsed = AbLegacyAddress.TryParse(def.Address, device.Options.PlcFamily);
+ // A malformed address is a config error, not a comms fault (BadNodeIdUnknown, warned once per tag).
+ if (parsed is null)
+ {
+ WarnMalformedOnce(device, def);
+ results[i] = new WriteResult(AbLegacyStatusMapper.BadNodeIdUnknown);
+ continue;
+ }
+
// Indirect addressing is parse-only (#247): refuse before any runtime or RMW read is created.
- if (parsed is { IsIndirect: true })
+ if (parsed.IsIndirect)
{
results[i] = new WriteResult(AbLegacyStatusMapper.BadNotSupported);
continue;
@@ -625,7 +640,10 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
Port: state.ParsedAddress.Port,
CipPath: state.EffectiveCipPath,
LibplctagPlcAttribute: state.Profile.LibplctagPlcAttribute,
- TagName: _options.Probe.ProbeAddress!,
+ // Normalised exactly like tag paths (PLC-5 octal I/O -> decimal); an unparseable probe address is passed through
+ // so the transport reports the failure as it always did.
+ TagName: AbLegacyAddress.TryParse(_options.Probe.ProbeAddress, state.Options.PlcFamily)?.ToLibplctagName()
+ ?? _options.Probe.ProbeAddress!,
Timeout: _options.Probe.Timeout);
IAbLegacyTagRuntime? probeRuntime = null;
@@ -873,6 +891,19 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
keep();
}
+ ///
+ /// A tag whose address does not parse for its device's PLC family (e.g. a PLC-5 octal I/O digit 8/9, a
+ /// function-file letter off MicroLogix) is a configuration error: answered BadNodeIdUnknown with the
+ /// handle/health untouched, and warned once per tag so a polled tag does not flood the log.
+ ///
+ private void WarnMalformedOnce(DeviceState device, AbLegacyTagDefinition def)
+ {
+ if (!device.MalformedAddressLogged.TryAdd(def.Name, 0)) return;
+ _logger.LogWarning(
+ "AbLegacy tag address is not valid for the device's PLC family. Driver={DriverInstanceId} Device={DeviceHostAddress} Reference={Reference} Address={Address} Family={Family}",
+ _driverInstanceId, def.DeviceHostAddress, def.Name, def.Address, device.Options.PlcFamily);
+ }
+
/// The create parameters for a tag's own runtime — shared by creation and the write-refusal check, so
/// the refusal is asked about exactly the runtime a write would otherwise create.
private AbLegacyTagCreateParams CreateParamsFor(DeviceState device, AbLegacyTagDefinition def, AbLegacyAddress parsed) =>
@@ -1105,6 +1136,9 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
///
public bool FirstNonZeroStatusLogged { get; set; }
+ /// Tags already warned about for a malformed address (once-per-tag log).
+ public System.Collections.Concurrent.ConcurrentDictionary MalformedAddressLogged { get; } = new();
+
///
/// Disposes all cached tag runtimes.
///
diff --git a/src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/AbLegacyTagConfigModel.cs b/src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/AbLegacyTagConfigModel.cs
index 06d9d5c6..948438cb 100644
--- a/src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/AbLegacyTagConfigModel.cs
+++ b/src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/AbLegacyTagConfigModel.cs
@@ -68,8 +68,11 @@ public sealed class AbLegacyTagConfigModel
if (TagConfigJson.DescribeInvalidEnum(_bag, "dataType") is { } dtError)
return dtError;
- if (string.IsNullOrWhiteSpace(Address))
- return "Address is required.";
+ // The editor cannot see the device's PLC family, so it checks only what no family accepts (the same
+ // AbLegacyAddress authority the deploy gate and runtime use) — never stricter than the gate, which adds the
+ // family-specific verdict (PLC-5 octal I/O, MicroLogix-only function files).
+ if (AbLegacyAddress.Validate(Address, family: null) is { } addressError)
+ return addressError;
// DELIBERATELY STRICTER THAN THE RUNTIME, and re-confirmed as such by the Gitea #554 survey — do not
// "align" it. PCCC data-file elements are limited to AbLegacyArray.MaxElements (256). The reader
diff --git a/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/AdminOperationsActor.cs b/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/AdminOperationsActor.cs
index 7c5112a6..afcf2e0a 100644
--- a/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/AdminOperationsActor.cs
+++ b/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/AdminOperationsActor.cs
@@ -262,12 +262,16 @@ public sealed class AdminOperationsActor : ReceiveActor
var driverByDevice = draft.Devices
.GroupBy(d => d.DeviceId, StringComparer.Ordinal)
.ToDictionary(g => g.Key, g => g.First().DriverInstanceId, StringComparer.Ordinal);
+ var deviceConfigById = draft.Devices
+ .GroupBy(d => d.DeviceId, StringComparer.Ordinal)
+ .ToDictionary(g => g.Key, g => g.First().DeviceConfig, StringComparer.Ordinal);
var tagConfigWarnings = new List<(string TagId, string Text)>();
foreach (var t in draft.Tags)
{
if (!driverByDevice.TryGetValue(t.DeviceId, out var driverInstanceId)) continue;
if (!driverTypeById.TryGetValue(driverInstanceId, out var driverType)) continue;
- foreach (var w in EquipmentTagConfigInspector.Inspect(driverType, t.TagConfig))
+ foreach (var w in EquipmentTagConfigInspector.Inspect(
+ driverType, t.TagConfig, deviceConfigById.GetValueOrDefault(t.DeviceId)))
tagConfigWarnings.Add((t.TagId, $"tag '{t.TagId}': {w}"));
}
if (tagConfigWarnings.Count > 0)
diff --git a/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/EquipmentTagConfigInspector.cs b/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/EquipmentTagConfigInspector.cs
index 57163a36..aa12b674 100644
--- a/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/EquipmentTagConfigInspector.cs
+++ b/src/Server/ZB.MOM.WW.OtOpcUa.ControlPlane/AdminOperations/EquipmentTagConfigInspector.cs
@@ -1,6 +1,7 @@
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
using ZB.MOM.WW.OtOpcUa.Driver.AbCip;
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
+using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
using ZB.MOM.WW.OtOpcUa.Driver.Calculation;
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
using ZB.MOM.WW.OtOpcUa.Driver.Modbus;
@@ -78,6 +79,47 @@ public static class EquipmentTagConfigInspector
return Inspectors.TryGetValue(driverType, out var inspect) ? inspect(tagConfig) : Array.Empty();
}
+ ///
+ /// with the owning device's DeviceConfig, so a driver whose
+ /// address grammar depends on the device (AbLegacy: the PlcFamily) is checked against the family the
+ /// runtime will use. Other drivers ignore the device config. A missing family key is the runtime default
+ /// (SLC 500); an unrecognised value is "unknown" and only the family-independent check applies — the gate
+ /// is never stricter than the runtime.
+ ///
+ /// The bound driver's DriverType.
+ /// The equipment tag's TagConfig JSON.
+ /// The owning device's DeviceConfig JSON (may be null).
+ /// The warnings; empty when clean.
+ public static IReadOnlyList Inspect(string? driverType, string? tagConfig, string? deviceConfig)
+ {
+ if (string.IsNullOrEmpty(driverType) || tagConfig is null) return Array.Empty();
+ if (string.Equals(driverType, DriverTypeNames.AbLegacy, StringComparison.OrdinalIgnoreCase))
+ return AbLegacyTagDefinitionFactory.Inspect(tagConfig, ReadAbLegacyFamily(deviceConfig));
+ return Inspect(driverType, tagConfig);
+ }
+
+ private static AbLegacyPlcFamily? ReadAbLegacyFamily(string? deviceConfig)
+ {
+ if (string.IsNullOrWhiteSpace(deviceConfig)) return AbLegacyPlcFamily.Slc500;
+ try
+ {
+ using var doc = System.Text.Json.JsonDocument.Parse(deviceConfig);
+ if (doc.RootElement.ValueKind != System.Text.Json.JsonValueKind.Object) return AbLegacyPlcFamily.Slc500;
+ foreach (var prop in doc.RootElement.EnumerateObject())
+ {
+ if (!string.Equals(prop.Name, "PlcFamily", StringComparison.OrdinalIgnoreCase)) continue;
+ var raw = prop.Value.ValueKind == System.Text.Json.JsonValueKind.String ? prop.Value.GetString() : null;
+ if (string.IsNullOrWhiteSpace(raw)) return AbLegacyPlcFamily.Slc500;
+ return Enum.TryParse(raw, ignoreCase: true, out var f) && Enum.IsDefined(f) ? f : null;
+ }
+ return AbLegacyPlcFamily.Slc500;
+ }
+ catch (System.Text.Json.JsonException)
+ {
+ return null;
+ }
+ }
+
/// Whether the given driver type has a mapped inspector.
/// The bound driver's DriverType.
/// when an inspector is registered for the driver type.
diff --git a/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/AbLegacyFamilyAddressingTests.cs b/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/AbLegacyFamilyAddressingTests.cs
index 40fdd620..595b4797 100644
--- a/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/AbLegacyFamilyAddressingTests.cs
+++ b/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/AbLegacyFamilyAddressingTests.cs
@@ -249,4 +249,72 @@ public sealed class AbLegacyFamilyAddressingTests
ex.Status.ShouldBe(AbStatus.Unsupported);
ex.Message.ShouldContain(why, Case.Insensitive);
}
+
+ private sealed class CapturingLogger : Microsoft.Extensions.Logging.ILogger
+ {
+ public readonly System.Collections.Concurrent.ConcurrentQueue Warnings = new();
+ public IDisposable? BeginScope(TState state) where TState : notnull => null;
+ public bool IsEnabled(Microsoft.Extensions.Logging.LogLevel logLevel) => true;
+ public void Log(Microsoft.Extensions.Logging.LogLevel level, Microsoft.Extensions.Logging.EventId id,
+ TState state, Exception? ex, Func f)
+ {
+ if (level == Microsoft.Extensions.Logging.LogLevel.Warning) Warnings.Enqueue(f(state, ex));
+ }
+ }
+
+ ///
+ /// A PLC-5 address that no longer parses (the pre-octal-era decimal 8/9 digit) is a config error: BadNodeIdUnknown on
+ /// read and write, no runtime created, health untouched, and ONE warning per tag however often it is polled.
+ ///
+ [Fact]
+ public async Task Malformed_address_is_BadNodeIdUnknown_warned_once_and_never_throws()
+ {
+ var factory = new FakeAbLegacyTagFactory();
+ var logger = new CapturingLogger();
+ var drv = new AbLegacyDriver(new AbLegacyDriverOptions
+ {
+ Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0", AbLegacyPlcFamily.Plc5)],
+ RawTags = AbLegacyRawTags.Entries(
+ new AbLegacyTagDefinition("Bad", "ab://10.0.0.5/1,0", "I:018", AbLegacyDataType.Int, Writable: true),
+ new AbLegacyTagDefinition("Good", "ab://10.0.0.5/1,0", "N7:1", AbLegacyDataType.Int)),
+ Probe = new AbLegacyProbeOptions { Enabled = false },
+ }, "drv-1", factory, logger);
+ await drv.InitializeAsync("{}", CancellationToken.None);
+ factory.Customise = p => new FakeAbLegacyTag(p) { Value = 1 };
+
+ var first = await drv.ReadAsync(["Bad", "Good"], CancellationToken.None);
+ var second = await drv.ReadAsync(["Bad"], CancellationToken.None);
+ var write = await drv.WriteAsync([new WriteRequest("Bad", 1)], CancellationToken.None);
+
+ first[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
+ second[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
+ write[0].StatusCode.ShouldBe(AbLegacyStatusMapper.BadNodeIdUnknown);
+ first[1].StatusCode.ShouldBe(AbLegacyStatusMapper.Good); // positive control: the refusal is per tag
+ factory.Tags.Keys.ShouldNotContain(k => k.StartsWith("I:"));
+ logger.Warnings.Count(w => w.Contains("not valid for the device's PLC family") && w.Contains("I:018")).ShouldBe(1);
+ }
+
+ /// The connectivity-probe address is normalised like tag paths (PLC-5 octal I/O handed over decimal).
+ [Fact]
+ public async Task Probe_address_is_normalised_like_tag_paths()
+ {
+ var factory = new FakeAbLegacyTagFactory();
+ var drv = new AbLegacyDriver(new AbLegacyDriverOptions
+ {
+ Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0", AbLegacyPlcFamily.Plc5)],
+ Probe = new AbLegacyProbeOptions
+ {
+ Enabled = true, Interval = TimeSpan.FromMilliseconds(50), Timeout = TimeSpan.FromMilliseconds(200),
+ ProbeAddress = "I:017",
+ },
+ }, "drv-1", factory);
+ await drv.InitializeAsync("{}", CancellationToken.None);
+
+ var deadline = DateTime.UtcNow.AddSeconds(5);
+ while (!factory.Tags.ContainsKey("I:15") && DateTime.UtcNow < deadline) await Task.Delay(20);
+ await drv.ShutdownAsync(CancellationToken.None);
+
+ factory.Tags.ContainsKey("I:15").ShouldBeTrue();
+ factory.Tags.ContainsKey("I:017").ShouldBeFalse();
+ }
}
diff --git a/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/AbLegacyFamilyAddressGateTests.cs b/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/AbLegacyFamilyAddressGateTests.cs
new file mode 100644
index 00000000..b0404868
--- /dev/null
+++ b/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/AbLegacyFamilyAddressGateTests.cs
@@ -0,0 +1,55 @@
+using Shouldly;
+using Xunit;
+using ZB.MOM.WW.OtOpcUa.AdminUI.Uns.TagEditors;
+using ZB.MOM.WW.OtOpcUa.ControlPlane.AdminOperations;
+using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
+
+namespace ZB.MOM.WW.OtOpcUa.AdminUI.Tests.Uns;
+
+/// #244/#245/#247: one address authority (AbLegacyAddress.Validate) behind the editor and the deploy gate.
+public sealed class AbLegacyFamilyAddressGateTests
+{
+ private static string Cfg(string address) => "{\"address\":\"" + address + "\",\"dataType\":\"Int\"}";
+
+ [Theory]
+ [InlineData("{\"PlcFamily\":\"Plc5\"}", "I:018", true)] // octal 8 on PLC-5
+ [InlineData("{\"PlcFamily\":\"Plc5\"}", "I:017/07", false)]
+ [InlineData("{\"PlcFamily\":\"Slc500\"}", "I:018", false)] // control: decimal on SLC
+ [InlineData("{\"plcFamily\":\"plc5\"}", "I:018", true)] // key + value case-insensitive
+ [InlineData("{\"PlcFamily\":\"Slc500\"}", "RTC:0.HR", true)] // function file off MicroLogix
+ [InlineData("{\"PlcFamily\":\"MicroLogix\"}", "RTC:0.HR", false)]
+ [InlineData(null, "RTC:0.HR", true)] // absent family = runtime default SLC 500
+ [InlineData("{\"PlcFamily\":\"Bogus\"}", "I:018", false)] // unknown family: never stricter than the runtime
+ [InlineData("{\"PlcFamily\":\"Slc500\"}", "Q9:0", true)]
+ public void Gate_checks_the_address_against_the_device_family(string? deviceConfig, string address, bool warns)
+ {
+ var w = EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg(address), deviceConfig);
+ (w.Count > 0).ShouldBe(warns, string.Join("; ", w));
+ }
+
+ [Fact]
+ public void Gate_warns_about_indirect_addresses_which_never_read()
+ {
+ EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg("N7:[N7:0]"), "{\"PlcFamily\":\"Slc500\"}")
+ .ShouldContain(x => x.Contains("indirect"));
+ }
+
+ [Theory]
+ [InlineData("N7:0", null)]
+ [InlineData("I:018", null)] // family unknown to the editor: another family accepts it
+ [InlineData("RTC:0.HR", null)] // MicroLogix accepts it
+ [InlineData("Q9:0", "any PLC family")]
+ public void Editor_validates_only_the_family_independent_shape(string address, string? error)
+ {
+ var result = AbLegacyTagConfigModel.FromJson(Cfg(address)).Validate();
+ if (error is null) result.ShouldBeNull(); else result!.ShouldContain(error);
+ }
+
+ [Fact]
+ public void Editor_is_never_stricter_than_the_gate()
+ {
+ const string address = "Q9:0";
+ AbLegacyTagConfigModel.FromJson(Cfg(address)).Validate().ShouldNotBeNull();
+ EquipmentTagConfigInspector.Inspect(DriverTypeNames.AbLegacy, Cfg(address), null).ShouldNotBeEmpty();
+ }
+}
diff --git a/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/RawTagConfigGateTests.cs b/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/RawTagConfigGateTests.cs
index 8acd8e63..65930cf0 100644
--- a/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/RawTagConfigGateTests.cs
+++ b/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/RawTagConfigGateTests.cs
@@ -346,7 +346,7 @@ public sealed class RawTagConfigGateTests
public void A_browse_committed_config_passes_the_gate(string driverType)
{
var tagConfig = RawBrowseCommitMapper.BuildTagConfig(
- driverType, "SomeAddress", BrowseFieldsFor(driverType));
+ driverType, driverType == DriverTypeNames.AbLegacy ? "N7:0" : "SomeAddress", BrowseFieldsFor(driverType));
TagConfigValidator.Validate(driverType, tagConfig).ShouldBeNull(
$"browse-commit for {driverType} must not author a config the import refuses");