Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.
## Fixture changes
- `AbLegacyServerFixture.cs`:
- Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
skip branch. Fixture now only skips on TCP unreachability.
- Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
- Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
attributes — one reason: endpoint not reachable.
- `AbLegacyReadSmokeTests.cs`:
- Device URI built from `sim.CipPath` instead of hardcoded empty path.
- New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
theory to the running container's family. Only one container binds
`:44818` at a time, so cross-family params would otherwise fail.
- `Slc500_write_then_read_round_trip` skips cleanly when the running
profile isn't `slc500`.
## E2E + seed + docs
- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
skip gate; synopsis calls out the `/1,0` vs empty cip-path split
between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
the hardware placeholder (`192.168.1.10`) to the Docker fixture
(`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
to describe the cip-path gate (not a dispatcher gap); env-var table
picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
+ `docs/DriverClis.md` — flip status from blocked to functional;
residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.
## Residual gap
Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.
## Verified
- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
`AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
now 5/5 against the respective docker-compose fixtures.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -132,7 +132,7 @@ section to skip it.
|
||||
|---|---|---|
|
||||
| Modbus | — | **PASS** (pymodbus fixture) |
|
||||
| AB CIP | — | **PASS** (ab_server fixture) |
|
||||
| AB Legacy | `AB_LEGACY_TRUST_WIRE=1` | **SKIP** (ab_server PCCC path upstream-broken — task #222) |
|
||||
| AB Legacy | — | **PASS** (ab_server SLC500/MicroLogix/PLC-5 profiles; `/1,0` cip-path required for the Docker fixture) |
|
||||
| S7 | — | **PASS** (python-snap7 fixture) |
|
||||
| FOCAS | `FOCAS_TRUST_WIRE=1` | **SKIP** (no public simulator — task #222 lab rig) |
|
||||
| TwinCAT | `TWINCAT_TRUST_WIRE=1` | **SKIP** (needs XAR or standalone Router — task #221) |
|
||||
|
||||
@@ -17,8 +17,8 @@
|
||||
},
|
||||
|
||||
"ablegacy": {
|
||||
"$comment": "Gated behind AB_LEGACY_TRUST_WIRE=1 — ab_server PCCC path upstream-broken, needs real SLC / MicroLogix / PLC-5 or RSEmulate 500.",
|
||||
"gateway": "ab://192.168.1.10/1,0",
|
||||
"$comment": "Works against ab_server --profile slc500 (Docker fixture) or real SLC/MicroLogix/PLC-5 hardware. `/1,0` cip-path is required for the Docker fixture; real hardware accepts an empty path — e.g. `ab://10.0.1.50:44818/`.",
|
||||
"gateway": "ab://127.0.0.1/1,0",
|
||||
"plcType": "Slc500",
|
||||
"address": "N7:5",
|
||||
"bridgeNodeId": "ns=2;s=AbLegacy/N7_5"
|
||||
|
||||
@@ -4,16 +4,19 @@
|
||||
End-to-end CLI test for the AB Legacy (PCCC) driver.
|
||||
|
||||
.DESCRIPTION
|
||||
**KNOWN-BROKEN upstream (ab_server PCCC dispatcher gap, verified 2026-04-21).**
|
||||
Works against real SLC / MicroLogix / PLC-5 hardware or a RSEmulate 500
|
||||
golden-box. Against the Docker ab_server the tests deliberately skip —
|
||||
same gate as tests/.../AbLegacy.IntegrationTests (AB_LEGACY_TRUST_WIRE=1).
|
||||
Runs against libplctag's ab_server PCCC Docker fixture (one of the
|
||||
slc500 / micrologix / plc5 compose profiles) or real SLC / MicroLogix /
|
||||
PLC-5 hardware. Five assertions: probe / driver-loopback / forward-
|
||||
bridge / reverse-bridge / subscribe-sees-change.
|
||||
|
||||
Five assertions: probe / driver-loopback / forward-bridge / reverse-bridge /
|
||||
subscribe-sees-change.
|
||||
ab_server enforces a non-empty CIP routing path (`/1,0`) before the
|
||||
PCCC dispatcher runs; real hardware accepts an empty path. The default
|
||||
$Gateway uses `/1,0` for the Docker fixture — pass `-Gateway
|
||||
"ab://host:44818/"` when pointing at a real SLC 5/05 / MicroLogix /
|
||||
PLC-5.
|
||||
|
||||
.PARAMETER Gateway
|
||||
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0.
|
||||
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0 (Docker fixture).
|
||||
|
||||
.PARAMETER PlcType
|
||||
Slc500 / MicroLogix / Plc5 / LogixPccc (default Slc500).
|
||||
@@ -39,13 +42,10 @@ param(
|
||||
$ErrorActionPreference = "Stop"
|
||||
. "$PSScriptRoot/_common.ps1"
|
||||
|
||||
# Skip-gate: the driver CLI's underlying AbLegacyServerFixture-equivalent
|
||||
# check — operators point at real hardware by setting AB_LEGACY_TRUST_WIRE=1.
|
||||
# Without the opt-in we skip (don't run against the known-broken ab_server).
|
||||
if (-not ($env:AB_LEGACY_TRUST_WIRE -eq "1" -or $env:AB_LEGACY_TRUST_WIRE -eq "true")) {
|
||||
Write-Skip "AB_LEGACY_TRUST_WIRE not set — skipping (ab_server PCCC is upstream-broken; set =1 against real hardware / RSEmulate)."
|
||||
exit 0
|
||||
}
|
||||
# ab_server PCCC works; the earlier "upstream-broken" gate is gone. The only
|
||||
# caveat: libplctag's ab_server rejects empty CIP paths, so $Gateway must
|
||||
# carry a non-empty path segment (default /1,0). Real SLC/PLC-5 hardware
|
||||
# accepts an empty path — use `ab://host:44818/` when pointing at real PLCs.
|
||||
|
||||
$abLegacyCli = Get-CliInvocation `
|
||||
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli" `
|
||||
|
||||
@@ -1,15 +1,17 @@
|
||||
-- AB Legacy e2e smoke seed — closes #213 (umbrella #209).
|
||||
--
|
||||
-- Hardware-gated. The ab_server PCCC dispatcher is upstream-broken (task #222
|
||||
-- tracks the lab rig + alternative fixtures), so verifying this seed end-to-end
|
||||
-- requires real SLC 500 / MicroLogix / PLC-5 hardware or an RSEmulate 500
|
||||
-- golden-box. The factory + seed ship here so the wiring is in place the
|
||||
-- moment real hardware becomes available — no server code changes needed.
|
||||
-- Works against the ab_server PCCC Docker fixture (one of the slc500 /
|
||||
-- micrologix / plc5 compose profiles) or real SLC 500 / MicroLogix / PLC-5
|
||||
-- hardware. Default HostAddress below points at the Docker fixture with a
|
||||
-- `/1,0` cip-path; libplctag's ab_server rejects empty paths before routing
|
||||
-- to the PCCC dispatcher. Real hardware uses an empty path — change the
|
||||
-- HostAddress to `ab://<plc-ip>:44818/` (note the trailing slash with nothing
|
||||
-- after) before running the seed for that setup.
|
||||
--
|
||||
-- Usage (once hardware is reachable):
|
||||
-- Usage:
|
||||
-- docker compose -f tests/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests/Docker/docker-compose.yml --profile slc500 up -d
|
||||
-- sqlcmd -S "localhost,14330" -d OtOpcUaConfig -U sa -P "OtOpcUaDev_2026!" \
|
||||
-- -i scripts/smoke/seed-ablegacy-smoke.sql
|
||||
-- (Update the `HostAddress` below to point at the real gateway first.)
|
||||
|
||||
SET NOCOUNT ON;
|
||||
SET XACT_ABORT ON;
|
||||
@@ -83,7 +85,7 @@ VALUES (@Gen, @DrvId, @ClusterId, @NsId, 'ablegacy-smoke', 'AbLegacy', N'{
|
||||
"TimeoutMs": 2000,
|
||||
"Devices": [
|
||||
{
|
||||
"HostAddress": "ab://192.168.1.10/1,0",
|
||||
"HostAddress": "ab://127.0.0.1:44818/1,0",
|
||||
"PlcFamily": "Slc500",
|
||||
"DeviceName": "slc-500"
|
||||
}
|
||||
@@ -92,7 +94,7 @@ VALUES (@Gen, @DrvId, @ClusterId, @NsId, 'ablegacy-smoke', 'AbLegacy', N'{
|
||||
"Tags": [
|
||||
{
|
||||
"Name": "N7_5",
|
||||
"DeviceHostAddress": "ab://192.168.1.10/1,0",
|
||||
"DeviceHostAddress": "ab://127.0.0.1:44818/1,0",
|
||||
"Address": "N7:5",
|
||||
"DataType": "Int",
|
||||
"Writable": true,
|
||||
@@ -117,6 +119,7 @@ PRINT ' Cluster: ' + @ClusterId;
|
||||
PRINT ' Node: ' + @NodeId;
|
||||
PRINT ' Generation: ' + CONVERT(nvarchar(20), @Gen);
|
||||
PRINT '';
|
||||
PRINT 'NOTE: hardware-gated. ab_server PCCC is upstream-broken (#222). Point the';
|
||||
PRINT ' DriverConfig HostAddress at real SLC / MicroLogix / PLC-5 / RSEmulate';
|
||||
PRINT ' and run the e2e script with AB_LEGACY_TRUST_WIRE=1.';
|
||||
PRINT 'NOTE: default points at the ab_server slc500 Docker fixture with a /1,0';
|
||||
PRINT ' cip-path (required by ab_server). For real SLC/MicroLogix/PLC-5';
|
||||
PRINT ' hardware, edit the DriverConfig HostAddress to end with /<empty>';
|
||||
PRINT ' e.g. "ab://<plc-ip>:44818/" and re-run this seed.';
|
||||
|
||||