Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.
## Fixture changes
- `AbLegacyServerFixture.cs`:
- Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
skip branch. Fixture now only skips on TCP unreachability.
- Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
- Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
attributes — one reason: endpoint not reachable.
- `AbLegacyReadSmokeTests.cs`:
- Device URI built from `sim.CipPath` instead of hardcoded empty path.
- New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
theory to the running container's family. Only one container binds
`:44818` at a time, so cross-family params would otherwise fail.
- `Slc500_write_then_read_round_trip` skips cleanly when the running
profile isn't `slc500`.
## E2E + seed + docs
- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
skip gate; synopsis calls out the `/1,0` vs empty cip-path split
between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
the hardware placeholder (`192.168.1.10`) to the Docker fixture
(`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
to describe the cip-path gate (not a dispatcher gap); env-var table
picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
+ `docs/DriverClis.md` — flip status from blocked to functional;
residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.
## Residual gap
Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.
## Verified
- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
`AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
now 5/5 against the respective docker-compose fixtures.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
100 lines
3.4 KiB
PowerShell
100 lines
3.4 KiB
PowerShell
#Requires -Version 7.0
|
|
<#
|
|
.SYNOPSIS
|
|
End-to-end CLI test for the AB Legacy (PCCC) driver.
|
|
|
|
.DESCRIPTION
|
|
Runs against libplctag's ab_server PCCC Docker fixture (one of the
|
|
slc500 / micrologix / plc5 compose profiles) or real SLC / MicroLogix /
|
|
PLC-5 hardware. Five assertions: probe / driver-loopback / forward-
|
|
bridge / reverse-bridge / subscribe-sees-change.
|
|
|
|
ab_server enforces a non-empty CIP routing path (`/1,0`) before the
|
|
PCCC dispatcher runs; real hardware accepts an empty path. The default
|
|
$Gateway uses `/1,0` for the Docker fixture — pass `-Gateway
|
|
"ab://host:44818/"` when pointing at a real SLC 5/05 / MicroLogix /
|
|
PLC-5.
|
|
|
|
.PARAMETER Gateway
|
|
ab://host[:port]/cip-path. Default ab://127.0.0.1/1,0 (Docker fixture).
|
|
|
|
.PARAMETER PlcType
|
|
Slc500 / MicroLogix / Plc5 / LogixPccc (default Slc500).
|
|
|
|
.PARAMETER Address
|
|
PCCC address to exercise. Default N7:5.
|
|
|
|
.PARAMETER OpcUaUrl
|
|
OtOpcUa server endpoint.
|
|
|
|
.PARAMETER BridgeNodeId
|
|
NodeId at which the server publishes the Address.
|
|
#>
|
|
|
|
param(
|
|
[string]$Gateway = "ab://127.0.0.1/1,0",
|
|
[string]$PlcType = "Slc500",
|
|
[string]$Address = "N7:5",
|
|
[string]$OpcUaUrl = "opc.tcp://localhost:4840",
|
|
[Parameter(Mandatory)] [string]$BridgeNodeId
|
|
)
|
|
|
|
$ErrorActionPreference = "Stop"
|
|
. "$PSScriptRoot/_common.ps1"
|
|
|
|
# ab_server PCCC works; the earlier "upstream-broken" gate is gone. The only
|
|
# caveat: libplctag's ab_server rejects empty CIP paths, so $Gateway must
|
|
# carry a non-empty path segment (default /1,0). Real SLC/PLC-5 hardware
|
|
# accepts an empty path — use `ab://host:44818/` when pointing at real PLCs.
|
|
|
|
$abLegacyCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli" `
|
|
-ExeName "otopcua-ablegacy-cli"
|
|
$opcUaCli = Get-CliInvocation `
|
|
-ProjectFolder "src/ZB.MOM.WW.OtOpcUa.Client.CLI" `
|
|
-ExeName "otopcua-cli"
|
|
|
|
$commonAbLegacy = @("-g", $Gateway, "-P", $PlcType)
|
|
$results = @()
|
|
|
|
$results += Test-Probe `
|
|
-Cli $abLegacyCli `
|
|
-ProbeArgs (@("probe") + $commonAbLegacy + @("-a", "N7:0"))
|
|
|
|
$writeValue = Get-Random -Minimum 1 -Maximum 9999
|
|
$results += Test-DriverLoopback `
|
|
-Cli $abLegacyCli `
|
|
-WriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $writeValue)) `
|
|
-ReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
|
|
-ExpectedValue "$writeValue"
|
|
|
|
$bridgeValue = Get-Random -Minimum 10000 -Maximum 19999
|
|
$results += Test-ServerBridge `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $bridgeValue)) `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-ExpectedValue "$bridgeValue"
|
|
|
|
$reverseValue = Get-Random -Minimum 20000 -Maximum 29999
|
|
$results += Test-OpcUaWriteBridge `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverReadArgs (@("read") + $commonAbLegacy + @("-a", $Address, "-t", "Int")) `
|
|
-ExpectedValue "$reverseValue"
|
|
|
|
$subValue = Get-Random -Minimum 30000 -Maximum 32766
|
|
$results += Test-SubscribeSeesChange `
|
|
-OpcUaCli $opcUaCli `
|
|
-OpcUaUrl $OpcUaUrl `
|
|
-OpcUaNodeId $BridgeNodeId `
|
|
-DriverCli $abLegacyCli `
|
|
-DriverWriteArgs (@("write") + $commonAbLegacy + @("-a", $Address, "-t", "Int", "-v", $subValue)) `
|
|
-ExpectedValue "$subValue"
|
|
|
|
Write-Summary -Title "AB Legacy e2e" -Results $results
|
|
if ($results | Where-Object { -not $_.Passed }) { exit 1 }
|