feat(modbus): wire Family / MelsecSubFamily / DisableFC23, and the form's timing keys
U1: a tag's addressString (Modicon / mnemonic / DL205 V-memory / MELSEC D-X-Y grammar) now resolves through ModbusAddressParser with the DRIVER's Family and MelsecSubFamily at every initialize and is authoritative; the family-unaware gates (deploy Inspect, AdminUI parse consult) accept what some family resolves. The tag editor gets an address-text field that resolves with the owning driver's family and persists both the string and the resolved region/offset/type fields; a hand edit drops the string. DisableFC23 now gates FC23: by default a 2..121-register holding write is one FC23 write + read-back (a unit answering exception 01, or failing FC23 at the transport, moves to FC16 for the rest of the generation); RTU framing deframes the FC23 reply. Live-checked: the pymodbus fixture implements FC23. Also: the AdminUI driver form serialises ModbusDriverOptions (TimeSpan strings), which the factory DTO never read - every timing field on the form was dead. The DTO now accepts both shapes (*Ms keys win). Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -86,6 +86,37 @@ public sealed class CommsRecoveryTests(ModbusSimulatorFixture sim)
|
||||
driver.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// U1 (DisableFC23 wired): a multi-register write on the default (FC23 write + read-back) path
|
||||
/// round-trips against the real server — whether it implements FC23 or answers Illegal Function and
|
||||
/// is moved to FC16 — and so does the forced-FC16 path. Uses the standard profile's scratch HR[200..209].
|
||||
/// </summary>
|
||||
[Theory]
|
||||
[InlineData(false, 200)]
|
||||
[InlineData(true, 202)]
|
||||
public async Task Multi_register_write_round_trips_with_and_without_FC23(bool disableFc23, int address)
|
||||
{
|
||||
SkipUnlessStandardLive();
|
||||
var tag = new ModbusTagDefinition("F", ModbusRegion.HoldingRegisters, (ushort)address, ModbusDataType.Float32);
|
||||
var opts = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host, Port = sim.Port, UnitId = 1, Timeout = TimeSpan.FromSeconds(2), DisableFC23 = disableFc23,
|
||||
RawTags = ModbusRawTags.Entries([tag]), Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(opts, "modbus-u1");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var value = disableFc23 ? 12.25f : 6.5f;
|
||||
for (var i = 0; i < 2; i++) // second write exercises the latched path when the server lacks FC23
|
||||
{
|
||||
var w = await driver.WriteAsync([new WriteRequest("F", value + i)], TestContext.Current.CancellationToken);
|
||||
w[0].StatusCode.ShouldBe(StatusGood);
|
||||
var r = await driver.ReadAsync(["F"], TestContext.Current.CancellationToken);
|
||||
r[0].Value.ShouldBe(value + i);
|
||||
}
|
||||
driver.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// H2: a deadbanded tag whose device returns holding the SAME value must publish the Good recovery.
|
||||
/// HR[5] is a constant 5 in the standard profile, so the recovery value is identical by construction.
|
||||
|
||||