feat(modbus): wire Family / MelsecSubFamily / DisableFC23, and the form's timing keys
U1: a tag's addressString (Modicon / mnemonic / DL205 V-memory / MELSEC D-X-Y grammar) now resolves through ModbusAddressParser with the DRIVER's Family and MelsecSubFamily at every initialize and is authoritative; the family-unaware gates (deploy Inspect, AdminUI parse consult) accept what some family resolves. The tag editor gets an address-text field that resolves with the owning driver's family and persists both the string and the resolved region/offset/type fields; a hand edit drops the string. DisableFC23 now gates FC23: by default a 2..121-register holding write is one FC23 write + read-back (a unit answering exception 01, or failing FC23 at the transport, moves to FC16 for the rest of the generation); RTU framing deframes the FC23 reply. Live-checked: the pymodbus fixture implements FC23. Also: the AdminUI driver form serialises ModbusDriverOptions (TimeSpan strings), which the factory DTO never read - every timing field on the form was dead. The DTO now accepts both shapes (*Ms keys win). Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -533,7 +533,7 @@ public sealed class ModbusDriver
|
||||
_skippedTags.BeginRebuild(_options.RawTags.Count);
|
||||
foreach (var entry in _options.RawTags)
|
||||
{
|
||||
if (ModbusTagDefinitionFactory.FromTagConfig(entry.TagConfig, entry.RawPath, out var def))
|
||||
if (ModbusTagDefinitionFactory.FromTagConfig(entry.TagConfig, entry.RawPath, _options.Family, _options.MelsecSubFamily, out var def))
|
||||
table[entry.RawPath] = def with { WriteIdempotent = entry.WriteIdempotent };
|
||||
else
|
||||
{
|
||||
@@ -556,6 +556,7 @@ public sealed class ModbusDriver
|
||||
_transport = transport;
|
||||
Volatile.Write(ref _tagsByRawPath, table);
|
||||
Volatile.Write(ref _refusalWarned, new ConcurrentDictionary<string, byte>(StringComparer.Ordinal));
|
||||
Volatile.Write(ref _fc23Unsupported, new ConcurrentDictionary<byte, byte>());
|
||||
WriteHealth(new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null));
|
||||
|
||||
// PR 23: kick off the probe loop once the transport is up. Initial state stays
|
||||
@@ -1619,6 +1620,7 @@ public sealed class ModbusDriver
|
||||
throw new ModbusWriteRefusedException(StatusBadOutOfRange,
|
||||
$"Write of {qty} registers to {tag.Name} exceeds MaxRegistersPerWrite={writeCap}. " +
|
||||
$"Split the tag (e.g. shorter StringLength or smaller ArrayCount) — partial FC16 chunks would lose atomicity.");
|
||||
if (await TryWriteViaFc23Async(transport, tag, bytes, qty, ct).ConfigureAwait(false)) return;
|
||||
var pdu = new byte[6 + 1 + bytes.Length];
|
||||
pdu[0] = 0x10;
|
||||
pdu[1] = (byte)(tag.Address >> 8); pdu[2] = (byte)(tag.Address & 0xFF);
|
||||
@@ -1634,6 +1636,79 @@ public sealed class ModbusDriver
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>FC23's spec ceiling on the write quantity (0x79); larger multi-register writes use FC16.</summary>
|
||||
private const ushort Fc23MaxWriteRegisters = 121;
|
||||
|
||||
/// <summary>
|
||||
/// Units that refused FC23 (exception 01) or failed it at the transport; their multi-register writes
|
||||
/// use FC16 for the rest of this driver generation. Replaced (never cleared in place) on re-init.
|
||||
/// </summary>
|
||||
private ConcurrentDictionary<byte, byte> _fc23Unsupported = new();
|
||||
|
||||
/// <summary>
|
||||
/// Multi-register write via FC23 (Read/Write Multiple Registers): the device writes the block and
|
||||
/// returns the SAME block read back in one transaction, so the write is confirmed by the device's own
|
||||
/// post-write registers. Gated by <see cref="ModbusDriverOptions.DisableFC23"/>. A device that does
|
||||
/// not implement FC23 (MELSEC QJ71MT91, S7 Modbus servers — exception 01) falls back to FC16 for this
|
||||
/// write and every later one on that unit, which is safe because an Illegal Function wrote nothing.
|
||||
/// A transport failure on FC23 is reported (its outcome is unknown, so it is not retried as FC16) and
|
||||
/// also moves the unit to FC16, so a gateway that cannot frame FC23 costs one failed write, not all.
|
||||
/// A read-back that differs from what was written (PLC logic overwrote it in the same scan, or the
|
||||
/// device clamped it) is logged once per tag; the write itself was accepted.
|
||||
/// </summary>
|
||||
/// <returns><see langword="true"/> when FC23 performed the write; <see langword="false"/> to use FC16.</returns>
|
||||
private async Task<bool> TryWriteViaFc23Async(
|
||||
IModbusTransport transport, ModbusTagDefinition tag, byte[] bytes, ushort qty, CancellationToken ct)
|
||||
{
|
||||
var unit = ResolveUnitId(tag);
|
||||
var unsupported = Volatile.Read(ref _fc23Unsupported);
|
||||
// Only genuinely multi-register writes: a single register forced onto FC16 (UseFC16ForSingleRegisterWrites)
|
||||
// stays on the function code the operator named.
|
||||
if (_options.DisableFC23 || qty < 2 || qty > Fc23MaxWriteRegisters || unsupported.ContainsKey(unit)) return false;
|
||||
|
||||
var pdu = new byte[10 + 1 + bytes.Length];
|
||||
pdu[0] = 0x17;
|
||||
pdu[1] = (byte)(tag.Address >> 8); pdu[2] = (byte)(tag.Address & 0xFF); // read start
|
||||
pdu[3] = (byte)(qty >> 8); pdu[4] = (byte)(qty & 0xFF); // read quantity
|
||||
pdu[5] = (byte)(tag.Address >> 8); pdu[6] = (byte)(tag.Address & 0xFF); // write start
|
||||
pdu[7] = (byte)(qty >> 8); pdu[8] = (byte)(qty & 0xFF); // write quantity
|
||||
pdu[9] = (byte)bytes.Length;
|
||||
Buffer.BlockCopy(bytes, 0, pdu, 10, bytes.Length);
|
||||
|
||||
byte[] resp;
|
||||
try
|
||||
{
|
||||
resp = await transport.SendAsync(unit, pdu, ct).ConfigureAwait(false);
|
||||
}
|
||||
catch (ModbusException mex) when (mex.ExceptionCode == 0x01)
|
||||
{
|
||||
if (unsupported.TryAdd(unit, 0))
|
||||
_logger.LogInformation(
|
||||
"Modbus unit {Unit} does not implement FC23 (Illegal Function); multi-register writes use FC16. Driver={DriverInstanceId}",
|
||||
unit, _driverInstanceId);
|
||||
return false;
|
||||
}
|
||||
catch (Exception ex) when (ex is not ModbusException && !(ex is OperationCanceledException && ct.IsCancellationRequested))
|
||||
{
|
||||
if (unsupported.TryAdd(unit, 0))
|
||||
_logger.LogWarning(ex,
|
||||
"Modbus FC23 write to unit {Unit} failed at the transport; later multi-register writes to it use FC16. Driver={DriverInstanceId}",
|
||||
unit, _driverInstanceId);
|
||||
throw;
|
||||
}
|
||||
|
||||
// resp = [0x17][byteCount][read-back registers…]
|
||||
if (resp.Length < 2 || resp[1] != bytes.Length || resp.Length < 2 + resp[1])
|
||||
throw new InvalidDataException(
|
||||
$"Modbus FC23 response for {tag.Name} malformed: expected {bytes.Length} read-back bytes, got {(resp.Length < 2 ? -1 : resp[1])}");
|
||||
if (!resp.AsSpan(2, bytes.Length).SequenceEqual(bytes)
|
||||
&& Volatile.Read(ref _refusalWarned).TryAdd("fc23:" + tag.Name, 0))
|
||||
_logger.LogWarning(
|
||||
"Modbus FC23 read-back of {RawPath} differs from the value written (device logic or clamping changed it); the write was accepted. Driver={DriverInstanceId}",
|
||||
tag.Name, _driverInstanceId);
|
||||
return true;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Encode an array-typed write value into a contiguous byte block by encoding each
|
||||
/// element with the scalar codec. Caller submits IList / Array of the element CLR type.
|
||||
|
||||
@@ -78,7 +78,7 @@ public static class ModbusDriverFactoryExtensions
|
||||
Host = dto.Host!,
|
||||
Port = dto.Port ?? 502,
|
||||
UnitId = dto.UnitId ?? 1,
|
||||
Timeout = TimeSpan.FromMilliseconds(dto.TimeoutMs ?? 2_000),
|
||||
Timeout = Span(dto.TimeoutMs, dto.Timeout) ?? TimeSpan.FromSeconds(2),
|
||||
MaxRegistersPerRead = dto.MaxRegistersPerRead ?? 125,
|
||||
MaxRegistersPerWrite = dto.MaxRegistersPerWrite ?? 123,
|
||||
MaxCoilsPerRead = dto.MaxCoilsPerRead ?? 2000,
|
||||
@@ -94,7 +94,7 @@ public static class ModbusDriverFactoryExtensions
|
||||
: ParseEnum<MelsecFamily>(dto.MelsecSubFamily, "<driver-level>", driverInstanceId, "MelsecSubFamily"),
|
||||
Transport = dto.Transport is null ? ModbusTransportMode.Tcp
|
||||
: ParseEnum<ModbusTransportMode>(dto.Transport, "<driver-level>", driverInstanceId, "Transport"),
|
||||
AutoProhibitReprobeInterval = dto.AutoProhibitReprobeMs is { } reprobeMs ? TimeSpan.FromMilliseconds(reprobeMs) : null,
|
||||
AutoProhibitReprobeInterval = Span(dto.AutoProhibitReprobeMs, dto.AutoProhibitReprobeInterval),
|
||||
AutoReconnect = dto.AutoReconnect ?? true,
|
||||
// v3: the deploy artifact (Wave C) populates rawTags with the cluster's authored raw Modbus
|
||||
// tags. The driver maps each RawTagEntry's TagConfig blob through ModbusTagDefinitionFactory
|
||||
@@ -104,22 +104,22 @@ public static class ModbusDriverFactoryExtensions
|
||||
Probe = new ModbusProbeOptions
|
||||
{
|
||||
Enabled = dto.Probe?.Enabled ?? true,
|
||||
Interval = TimeSpan.FromMilliseconds(dto.Probe?.IntervalMs ?? 5_000),
|
||||
Timeout = TimeSpan.FromMilliseconds(dto.Probe?.TimeoutMs ?? 2_000),
|
||||
Interval = Span(dto.Probe?.IntervalMs, dto.Probe?.Interval) ?? TimeSpan.FromSeconds(5),
|
||||
Timeout = Span(dto.Probe?.TimeoutMs, dto.Probe?.Timeout) ?? TimeSpan.FromSeconds(2),
|
||||
ProbeAddress = dto.Probe?.ProbeAddress ?? 0,
|
||||
},
|
||||
KeepAlive = dto.KeepAlive is null ? new ModbusKeepAliveOptions() : new ModbusKeepAliveOptions
|
||||
{
|
||||
Enabled = dto.KeepAlive.Enabled ?? true,
|
||||
Time = TimeSpan.FromMilliseconds(dto.KeepAlive.TimeMs ?? 30_000),
|
||||
Interval = TimeSpan.FromMilliseconds(dto.KeepAlive.IntervalMs ?? 10_000),
|
||||
Time = Span(dto.KeepAlive.TimeMs, dto.KeepAlive.Time) ?? TimeSpan.FromSeconds(30),
|
||||
Interval = Span(dto.KeepAlive.IntervalMs, dto.KeepAlive.Interval) ?? TimeSpan.FromSeconds(10),
|
||||
RetryCount = dto.KeepAlive.RetryCount ?? 3,
|
||||
},
|
||||
IdleDisconnectTimeout = dto.IdleDisconnectMs is { } ms ? TimeSpan.FromMilliseconds(ms) : null,
|
||||
IdleDisconnectTimeout = Span(dto.IdleDisconnectMs, dto.IdleDisconnectTimeout),
|
||||
Reconnect = dto.Reconnect is null ? new ModbusReconnectOptions() : new ModbusReconnectOptions
|
||||
{
|
||||
InitialDelay = TimeSpan.FromMilliseconds(dto.Reconnect.InitialDelayMs ?? 0),
|
||||
MaxDelay = TimeSpan.FromMilliseconds(dto.Reconnect.MaxDelayMs ?? 30_000),
|
||||
InitialDelay = Span(dto.Reconnect.InitialDelayMs, dto.Reconnect.InitialDelay) ?? TimeSpan.Zero,
|
||||
MaxDelay = Span(dto.Reconnect.MaxDelayMs, dto.Reconnect.MaxDelay) ?? TimeSpan.FromSeconds(30),
|
||||
BackoffMultiplier = dto.Reconnect.BackoffMultiplier ?? 2.0,
|
||||
},
|
||||
};
|
||||
@@ -127,6 +127,23 @@ public static class ModbusDriverFactoryExtensions
|
||||
return options;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// One timing knob, accepted in BOTH shapes the config can carry: the <c>*Ms</c> integer keys (CLI,
|
||||
/// seed data, hand-authored JSON) and the TimeSpan-string keys the AdminUI driver form emits — it
|
||||
/// serialises <see cref="ModbusDriverOptions"/> itself, so it writes <c>"timeout":"00:00:07"</c>, not
|
||||
/// <c>timeoutMs</c>. Before this every timing field on that form was silently ignored. The
|
||||
/// millisecond key wins when both are present; an unparseable TimeSpan string is ignored (the
|
||||
/// previous behaviour for these keys), never a reason to fail the driver.
|
||||
/// </summary>
|
||||
private static TimeSpan? Span(int? milliseconds, JsonElement? timeSpan)
|
||||
{
|
||||
if (milliseconds is { } ms) return TimeSpan.FromMilliseconds(ms);
|
||||
if (timeSpan is { ValueKind: JsonValueKind.String } e
|
||||
&& TimeSpan.TryParse(e.GetString(), System.Globalization.CultureInfo.InvariantCulture, out var parsed))
|
||||
return parsed;
|
||||
return null;
|
||||
}
|
||||
|
||||
private static T ParseEnum<T>(string? raw, string? tagName, string driverInstanceId, string field) where T : struct, Enum
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(raw))
|
||||
@@ -156,6 +173,8 @@ public static class ModbusDriverFactoryExtensions
|
||||
public byte? UnitId { get; init; }
|
||||
/// <summary>Gets or sets the timeout in milliseconds.</summary>
|
||||
public int? TimeoutMs { get; init; }
|
||||
/// <summary>Gets or sets the timeout as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? Timeout { get; init; }
|
||||
/// <summary>Gets or sets the maximum number of registers per read operation.</summary>
|
||||
public ushort? MaxRegistersPerRead { get; init; }
|
||||
/// <summary>Gets or sets the maximum number of registers per write operation.</summary>
|
||||
@@ -182,6 +201,8 @@ public static class ModbusDriverFactoryExtensions
|
||||
public string? Transport { get; init; }
|
||||
/// <summary>Gets or sets the automatic prohibition reprobei interval in milliseconds.</summary>
|
||||
public int? AutoProhibitReprobeMs { get; init; }
|
||||
/// <summary>Gets or sets the re-probe interval as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? AutoProhibitReprobeInterval { get; init; }
|
||||
/// <summary>Gets or sets a value indicating whether automatic reconnection is enabled.</summary>
|
||||
public bool? AutoReconnect { get; init; }
|
||||
/// <summary>Gets or sets the authored raw tags (RawPath + TagConfig blob + WriteIdempotent) the
|
||||
@@ -194,6 +215,8 @@ public static class ModbusDriverFactoryExtensions
|
||||
public ModbusKeepAliveDto? KeepAlive { get; init; }
|
||||
/// <summary>Gets or sets the idle disconnect timeout in milliseconds.</summary>
|
||||
public int? IdleDisconnectMs { get; init; }
|
||||
/// <summary>Gets or sets the idle disconnect timeout as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? IdleDisconnectTimeout { get; init; }
|
||||
/// <summary>Gets or sets the reconnect configuration.</summary>
|
||||
public ModbusReconnectDto? Reconnect { get; init; }
|
||||
}
|
||||
@@ -206,6 +229,10 @@ public static class ModbusDriverFactoryExtensions
|
||||
public int? TimeMs { get; init; }
|
||||
/// <summary>Gets or sets the keep-alive interval in milliseconds.</summary>
|
||||
public int? IntervalMs { get; init; }
|
||||
/// <summary>Gets or sets the keep-alive time as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? Time { get; init; }
|
||||
/// <summary>Gets or sets the keep-alive interval as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? Interval { get; init; }
|
||||
/// <summary>Gets or sets the retry count.</summary>
|
||||
public int? RetryCount { get; init; }
|
||||
}
|
||||
@@ -216,6 +243,10 @@ public static class ModbusDriverFactoryExtensions
|
||||
public int? InitialDelayMs { get; init; }
|
||||
/// <summary>Gets or sets the maximum reconnect delay in milliseconds.</summary>
|
||||
public int? MaxDelayMs { get; init; }
|
||||
/// <summary>Gets or sets the initial reconnect delay as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? InitialDelay { get; init; }
|
||||
/// <summary>Gets or sets the maximum reconnect delay as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? MaxDelay { get; init; }
|
||||
/// <summary>Gets or sets the backoff multiplier for exponential reconnect delays.</summary>
|
||||
public double? BackoffMultiplier { get; init; }
|
||||
}
|
||||
@@ -228,6 +259,10 @@ public static class ModbusDriverFactoryExtensions
|
||||
public int? IntervalMs { get; init; }
|
||||
/// <summary>Gets or sets the probe timeout in milliseconds.</summary>
|
||||
public int? TimeoutMs { get; init; }
|
||||
/// <summary>Gets or sets the probe interval as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? Interval { get; init; }
|
||||
/// <summary>Gets or sets the probe timeout as a TimeSpan string (the AdminUI form's shape).</summary>
|
||||
public JsonElement? Timeout { get; init; }
|
||||
/// <summary>Gets or sets the probe register address.</summary>
|
||||
public ushort? ProbeAddress { get; init; }
|
||||
}
|
||||
|
||||
@@ -93,9 +93,10 @@ public static class ModbusRtuFraming
|
||||
// Exception frame: excCode(1) + CRC(2).
|
||||
trailing = 1 + 2;
|
||||
}
|
||||
else if (fc is 0x01 or 0x02 or 0x03 or 0x04)
|
||||
else if (fc is 0x01 or 0x02 or 0x03 or 0x04 or 0x17)
|
||||
{
|
||||
// Read response: byteCount(1) then byteCount data bytes + CRC(2).
|
||||
// Read response (and FC23 Read/Write Multiple, whose reply is a read): byteCount(1) then
|
||||
// byteCount data bytes + CRC(2).
|
||||
var bc = new byte[1];
|
||||
await ReadExactlyAsync(stream, bc, ct).ConfigureAwait(false);
|
||||
var byteCount = bc[0];
|
||||
@@ -105,9 +106,9 @@ public static class ModbusRtuFraming
|
||||
}
|
||||
else
|
||||
{
|
||||
// Fixed 4-byte echo: correct for the write FCs this driver emits (05/06/0F/10). A future
|
||||
// variable-length response FC outside 01-04 (e.g. FC23) would be mis-sized here and
|
||||
// surface as a desync — revisit the FC-shape table if the driver starts emitting one.
|
||||
// Fixed 4-byte echo: correct for the write FCs this driver emits (05/06/0F/10). FC23 is
|
||||
// variable-length and handled above; any NEW variable-length response FC must be added there
|
||||
// or it is mis-sized here and surfaces as a desync.
|
||||
trailing = 4 + 2;
|
||||
}
|
||||
|
||||
|
||||