F1: deploy/wonder-app-vd03/appsettings.Site.json (outside git, WP1.2's
StartupValidator gate applies live on next install/upgrade) was missing the
now-required AuditLog:SiteWriter:DatabasePath, added pointing at
E:\ApiInstall\ScadaBridge\site\data\auditlog.db alongside the file's
existing SiteEventLog/LocalDb paths; scanned deploy/ for other Site-role
appsettings with the same gap (none) and confirmed wonder does not pin
LocalDb:Replication:MaxBatchSize (F2 doesn't apply there).
F2: re-pin an explicit LocalDb:Replication:MaxBatchSize=64 on docker/site-a
node-a and node-b. MaxBatchBytes (2 MB default) only bounds the wire
message via the per-message split in SyncSession.PumpLoopAsync;
MaxBatchSize separately bounds the DB read page in
OplogStore.ReadBatchAboveAsync/SnapshotStreamer, which materializes the
whole page into memory before that split runs. Left at the 500 default, a
reconnect drain of worst-case config_json rows could transiently allocate
~35 MB per read even though every wire message stayed within budget.
Updated the CLAUDE.md LocalDb bullet to stop implying the row cap is fully
redundant with the byte budget (topology-guide.md has no matching claim).
F3: StoreAndForwardService's observer-queue onDropped callback logged a
Warning per dropped item, flooding logs at sweep rate for a stuck observer
with a large queue. LogObserverQueueDrop now logs once immediately on the
first drop of an episode, then throttles to at most one rollup Warning per
minute while drops continue, reporting the count dropped since the last
log; the cumulative ObserverQueueDroppedCount counter is unaffected.
Extended StoreAndForwardServiceTests with
ObserverQueue_ManyDropsInOneEpisode_LogsExactlyOneWarning, which floods the
bounded queue and pins exactly one drop-related Warning log for the
episode via a small CapturingLogger test double.
dotnet build ZB.MOM.WW.ScadaBridge.slnx: 0 warnings, 0 errors.
dotnet test StoreAndForward.Tests: 134/134 passed.
dotnet test Host.Tests: 490/490 passed.
CachedDrain_OrphanRow_PastGrace_IsAbandoned_AndTheValidRowStillFlows gated on
IngestCachedTelemetryAsync being received once and then asserted, bare, that the
valid row had been marked Forwarded. The drain does that strictly AFTER the push
returns: OnCachedDrainAsync abandons the orphan (:351), pushes the batch (:366),
then parses the ack and marks the accepted ids (:380). Observing the push
therefore orders nothing with respect to the second MarkForwardedAsync — under a
loaded parallel run the post-push continuation can be scheduled after the poll
that saw the push, and the assertion fails fast with "Actually received no
matching calls" while the orphan's own earlier call is reported as the single
non-matching one.
Reproduced deterministically by delaying only the post-push step, which fails
exactly this test (11 siblings still pass) at ~1.3s into the assembly run —
matching the observed failure's fast-fail signature and pointing at line 430.
With the fix the same injected delay passes; suppressing the valid row's
MarkForwarded entirely still fails the test with the identical message, so the
claim (orphan abandoned in its own call, valid row pushed and marked, exactly
once each with exactly the same arguments) is unchanged in force.
Same unsynchronized-assertion class as c4caebe9, different actor. Test-only; the
drain's abandon/push/mark ordering is correct as written.
Both NotifyDispatcher_AuditWriter_Throws_DeliveryStillSucceeds and
NotificationDispatch_BrokenAuditWriter_StillTransitionsToDelivered read the
throwing writer's attempt counter with a bare Assert immediately after an
AwaitAssert on the Notifications row reaching Delivered. That assumes the audit
writes happen no later than the operational status write, which the dispatcher
deliberately does NOT guarantee: DeliverOneAsync persists the delivery state
first (NotificationOutboxActor.cs:657) and only then emits the Attempted
(:663) and terminal (:676) audit rows — audit is best-effort and must never
gate the user-facing action. Observing Delivered therefore establishes no
happens-before edge with the writer, and under a loaded full-solution parallel
run the continuation after the DB write can be scheduled after the poll that
saw Delivered, so the counter reads 0 and the test fails with "saw 0".
Reproduced deterministically by delaying only the post-update audit emission,
which yields both observed failure messages verbatim; with the fix in place the
same injected delay passes, and suppressing the emissions entirely still fails
both tests with the identical messages — the claims (delivery despite audit
failure, and attempts >= N) are unchanged in force, only the ordering
assumption is gone.
Test-only change; the update-then-audit ordering predates the remediation
(#23 M4) and is correct as written.
Implements WP3.2 stage (b) per docs/plans/2026-08-15-site-events-policy-design.md.
- Per-run instance-script Started/Completed Info site events are now off by
default (SiteRuntimeOptions.PerRunScriptEvents=false) instead of firing on
every run, closing the dominant site_events writer. Gated at the ScriptRunLauncher
call sites (moved there from ScriptExecutionActor by WP3.1). Error-level events
(timeout/failure/stuck-watchdog/recursion-limit) remain unconditional.
- ScriptRunSummaryRecorder accumulates per-(instance, script) run counters and a
new site-only ScriptRunSummaryFlushService emits one aggregate "script" Info
site event per ScriptRunSummaryIntervalSeconds (default 300s), top-50-script
breakdown with an "others" rollup, zero-activity intervals emit nothing.
- Per-script opt-in via PerRunScriptEventScripts ("Instance/Script" exact or
"Instance/*" wildcard), matched by the new pure ScriptRunEventPolicy. All three
options are read from IOptionsMonitor<SiteRuntimeOptions> per run, so the
policy is hot-togglable without a restart.
- Fixed the stale "event log is not replicated" comment at AkkaHostedService.cs
(~905): site_events IS registered in SiteLocalDbSetup.ReplicatedTables — the
singleton is what makes queries always hit the actively-written copy;
replication is what gives the singleton history to read after a failover
(memo Decision (b)). site_events replication itself is unchanged (still
registered) and already pinned by
tests/ZB.MOM.WW.ScadaBridge.Host.Tests/SiteLocalDbCdcRegistrationTests.cs.
- Updated Component-SiteEventLogging.md (Volume Policy section, corrected
Storage/replication rationale) and Component-SiteRuntime.md (Script Run
Launch + Error Handling sections).
WP2.6 (arch-review remediation, cross-cutting misc):
- SiteExternalSystemRepository: name/ID-indexed ExternalSystemDefinitionCache replaces
the fetch-all + reverse-map scan on every by-ID/method lookup; loaded once per
redeploy, invalidated by DeploymentManagerActor after HandleDeployArtifacts applies
external-system changes. Static JsonSerializerOptions for method-list parsing.
- Inbound API: short-TTL ApiMethodCache fronts the per-request ApiMethod repository
fetch; invalidated by name via the existing ScriptArtifactChangeSubscriber/
IScriptArtifactChangeBus pipeline, self-healing via TTL for changes the bus
doesn't cover (e.g. Management API edits).
- StoreAndForward: the cached-call audit-observer queue — the one unbounded channel
left in the system — is now bounded (ObserverQueueCapacity, default 10,000) with
DropOldest overflow and a dropped-notification counter.
- SiteStreamManager: alarm state changes now travel a dedicated publish
source/broadcast hub, isolated from the (far higher-volume) attribute path, so an
attribute storm can no longer evict a pending alarm transition; the alarm hand-off
queue is bounded with a drop counter surfaced on the site health report
(SiteStreamAlarmDropCount via the new SiteStreamAlarmDropReporter), and publishing
is skipped entirely at zero subscribers on either path.
- CLI ManagementHttpClient: explicit 30s HttpClient.Timeout on the shared
construction (was the 100s framework default), overridable via
SCADABRIDGE_HTTP_TIMEOUT_SECONDS.
Deviation: the failback-probe heartbeat item is NOT included — its only viable
surface (CentralChannelProvider.cs / heartbeat consumers) lives entirely in the
Communication project, explicitly off-limits to this work package this phase.
Tests: SiteRuntime.Tests (550), InboundAPI.Tests (278), StoreAndForward.Tests (133),
CLI.Tests (390), HealthMonitoring.Tests (97) — all green after full solution build.
Closes WP1.2 of the arch-review remediation plan (finding #2, High):
SqliteAuditWriterOptions.DatabasePath defaulted to CWD-relative "auditlog.db",
which on the docker rig resolves onto the container's ephemeral overlayfs
(not the mounted /app/data volume), silently discarding the pending audit
forward-state backlog on every recreate; nothing in docker/ or docker-env2/
overrode it; FlushIntervalMs was validated but never read by the writer loop
(one commit per event even at trickle rate); and no PRAGMA synchronous was
set (SQLite's FULL default fsyncs every commit).
- DatabasePath now has no default (mirrors ZB.MOM.WW.LocalDb's LocalDbOptions.Path)
and is required pre-host for Site nodes only, via a new StartupValidator raw-config
check (top-level "AuditLog:SiteWriter:DatabasePath", NOT nested under ScadaBridge:
AddAuditLog binds that section off the configuration root). SqliteAuditWriterOptionsValidator
deliberately does NOT check DatabasePath itself, because AddAuditLog runs its
ValidateOnStart on both Central and Site composition roots but only Site nodes
ever resolve the writer — checking it there would fail Central's boot too.
- All 8 site-node appsettings under docker/ and docker-env2/ now set
AuditLog:SiteWriter:DatabasePath to /app/data/auditlog.db (mounted volume,
survives container recreate, same convention as LocalDb:Path); the local-dev
base appsettings.Site.json sets ./data/auditlog.db to match.
- The writer loop now honors FlushIntervalMs: after draining the immediately
available burst, it keeps the transaction open (bounded by FlushIntervalMs
from the first event) waiting for more trickle-rate events before committing,
instead of flushing (and fsyncing) per event.
- PRAGMA synchronous = NORMAL on the write connection — audit is best-effort by
design (CLAUDE.md: "Audit-write failure NEVER aborts the user-facing action"),
so NORMAL's narrower power-loss window is an acceptable trade for far fewer
fsyncs; WAL mode still guarantees no corruption.
- Tests: StartupValidator site-required/blank/central-exempt cases; writer
trickle-load single-transaction coalescing + beyond-interval separate-transaction
regression (new FlushCountForTests seam); options-validator doc updates reflecting
the moved responsibility. Full suite runs green: AuditLog.Tests 368/368,
Host.Tests 480/480.
One-time migration note: the existing container-local auditlog.db (wherever it
landed under CWD) is abandoned by this change, not migrated — already-forwarded
rows are safe centrally (AuditLog is the durable copy), and any still-Pending
rows on the abandoned path are lost once. This is the exact bug being fixed, not
a new loss: those rows were already living outside the mounted volume and would
not have survived the next container recreate regardless. Cross-reference
docs/known-issues/2026-07-20-cached-telemetry-drain-hot-loop.md, which this
placement bug caused.
SiteLocalDbSetup.OnReady registered all ten replicated tables
unconditionally, so a deliberately unreplicated site node (site-b and
site-c on the rig) carried the full 30-trigger CDC set forever. Every
write to those tables paid two extra INSERTs plus a json_object
serialization of the whole row, inside the caller's own transaction, and
appended to an oplog nothing ever drains. Arch-review finding #5 (High),
repo half; the library half — trigger cleanup API and O(1) backlog — is
WP3.3.
The ten RegisterReplicated calls are now behind a guard on whether the
node has LocalDb:Replication:PeerAddress OR LocalDb:Replication:ApiKey.
Either key counts, and the OR is load-bearing rather than defensive:
replication is one bidirectional stream that exactly one side dials, so
only the initiator sets PeerAddress. Verified against the rig — site-a
node-a has PeerAddress + ApiKey, site-a node-b (passive) has ApiKey
alone, site-b/site-c have no Replication section at all. Keying on
PeerAddress alone would have stripped capture from every passive node and
silently made each pair converge in one direction only.
The load-bearing ordering documented in the file is preserved: DDL still
precedes registration, and the legacy migrator still runs unconditionally
after it — an unreplicated node must still absorb its pre-Phase-1 files,
and it has no peer for those rows to be invisible to.
Known residual, documented in-file and in the topology guide: a database
file first created by an older build keeps its stale __localdb_* triggers.
The guard decides whether triggers are installed, not whether existing
ones are removed, and the library has no removal API until WP3.3. Moot on
the docker rig, where a schema-change redeploy recreates the volumes.
The inverse is also now documented: enabling replication on a site that
has run without it does not baseline existing rows, since CDC never
recorded them in __localdb_row_version and the snapshot resync streams
from that ledger.
Tests: new SiteLocalDbCdcRegistrationTests asserts trigger presence and
absence via sqlite_master across all four config shapes (none, ApiKey
only, PeerAddress + ApiKey, and the notification-table exclusion), plus
DDL-still-runs and migrator-still-runs on the unreplicated branch.
SiteLocalDbWiringTests and the integration site-pair harness now
configure an ApiKey — mirroring the rig's passive node — so their
registration and convergence assertions still describe a replicating
node. 483/483 Host.Tests pass; the 20 offline LocalDb convergence tests
still pass.
The Secrets management UI (ZB.MOM.WW.Secrets Secrets.Ui, mounted at
/admin/secrets) has been linked from the NavMenu Admin section since the
Theme adoption, but no NavMenu test asserted it. Add bUnit coverage that
the item renders for an Administrator and is absent for a
Designer+Deployer principal, matching the existing role-gate test style.
The rig pointed at the shared 10.100.0.35 GLAuth whose serviceaccount password
was rotated (SEC-36), so central login had been failing ('Authentication service
is misconfigured') and a TEMP DisableLogin workaround was pending. Central nodes
now point at the local redundant pair (scadaproj/infra/glauth-redundant,
host.docker.internal:3893 + FallbackServers :3894), where the dev bind password
is correct — live-gated on the redeployed rig: login OK, primary-kill failover,
sticky preference (bind-count proven), walk-back on backup-kill.
AuthFlowTests factory bound as cn=admin for search-then-bind, but the current
directory grants the search capability only to serviceaccount (admin searches
return 50 Insufficient access) — stale since the GLAuth config evolved; the test
had been skipping on the closed port and failed once anything answered :3893.
Now binds as serviceaccount; AuthFlowTests 5/5 against the pair.