dohertj2 dohertj2
  • Joined on 2026-02-20
dohertj2 created pull request dohertj2/lmxopcua#160 2026-04-20 11:31:06 -04:00
S7 integration fixture via python-snap7 (#216) + per-driver test-fixture coverage docs
dohertj2 created branch s7-integration-fixture in dohertj2/lmxopcua 2026-04-20 11:31:06 -04:00
dohertj2 pushed to s7-integration-fixture at dohertj2/lmxopcua 2026-04-20 11:31:06 -04:00
1d3544f18e S7 integration fixture — python-snap7 server closes the wire-level coverage gap (#216) + per-driver fixture coverage docs for every driver in the fleet. Closes #216. Two shipments in one PR because the docs landed as I surveyed each driver's fixture + the S7 work is the first wire-level-gap closer pulled from that survey.
dohertj2 deleted branch abcip-alarm-source from dohertj2/lmxopcua 2026-04-20 04:26:46 -04:00
dohertj2 merged pull request dohertj2/lmxopcua#159 2026-04-20 04:26:41 -04:00
AbCip IAlarmSource via ALMD projection (#177, feature-flagged)
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 04:26:41 -04:00
4fe96fca9b Merge pull request 'AbCip IAlarmSource via ALMD projection (#177, feature-flagged)' (#159) from abcip-alarm-source into v2
4e80db4844 AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).
Compare 2 commits »
dohertj2 created pull request dohertj2/lmxopcua#159 2026-04-20 04:26:28 -04:00
AbCip IAlarmSource via ALMD projection (#177, feature-flagged)
dohertj2 created branch abcip-alarm-source in dohertj2/lmxopcua 2026-04-20 04:26:26 -04:00
dohertj2 pushed to abcip-alarm-source at dohertj2/lmxopcua 2026-04-20 04:26:26 -04:00
4e80db4844 AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).
dohertj2 deleted branch abcip-whole-udt-read from dohertj2/lmxopcua 2026-04-20 04:19:59 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 04:19:54 -04:00
f6d5763448 Merge pull request 'AbCip whole-UDT read optimization (#194)' (#158) from abcip-whole-udt-read into v2
780358c790 AbCip whole-UDT read optimization (#194) — declaration-driven member grouping collapses N per-member reads into one parent-UDT read + client-side decode. Closes task #194. On a batch that includes multiple members of the same hand-declared UDT tag, ReadAsync now issues one libplctag read on the parent + decodes each member from the runtime's buffer at its computed byte offset. A 6-member Motor UDT read goes from 6 libplctag round-trips to 1 — the Rockwell-suggested pattern for minimizing CIP request overhead on batch reads of UDT state (decision #11's follow-through on what the template decoder from task #179 was meant to enable). AbCipUdtMemberLayout is a pure-function helper that computes declared-member byte offsets under Logix natural-alignment rules (SInt 1-byte / Int 2-byte / DInt + Real + Dt 4-byte / LInt + ULInt + LReal 8-byte; alignment pad inserted before each member as needed). Opts out for BOOL / String / Structure members — BOOL storage in Logix UDTs packs into a hidden host byte whose position can't be computed from declaration-only info, and String members need length-prefix + STRING[82] fan-out which libplctag already handles via a per-tag DecodeValue path. The CIP Template Object shape from task #179 (when populated via FetchUdtShapeAsync) carries real offsets for those members — layering that richer path on top of the planner is a separate follow-up and does not change this PR's conservative behaviour. AbCipUdtReadPlanner is the scheduling function ReadAsync consults each batch — pure over (requests, tagsByName), emits Groups + Fallbacks. A group is formed when (a) the reference resolves to "parent.member"; (b) parent is a Structure tag with declared Members; (c) the layout helper succeeds on those members; (d) the specific member appears in the computed offset map; (e) at least two members of the same parent appear in the batch — single-member groups demote to the fallback path because one whole-UDT read vs one per-member read is equivalent cost but more client-side work. Original batch indices are preserved through the plan so out-of-order batches write decoded values back at the right output slot; the caller's result array order is invariant. IAbCipTagRuntime.DecodeValueAt(AbCipDataType, int offset, int? bitIndex) is the new hot-path method — LibplctagTagRuntime delegates to libplctag's offset-aware Get*(offset) calls (GetInt32, GetFloat32, etc.) that were always there; previously every call passed offset 0. DecodeValue(type, bitIndex) stays as the shorthand + forwards to DecodeValueAt with offset 0, preserving the existing single-tag read path + every test that exercises it. FakeAbCipTag gains a ValuesByOffset dictionary so tests can drive multi-member decoding by setting offset→value before the read fires; unmapped offsets fall back to the existing Value field so the 200+ existing tests that never set ValuesByOffset keep working unchanged. AbCipDriver.ReadAsync refactored: planner splits the batch, ReadGroupAsync handles each UDT group (one EnsureTagRuntimeAsync on the parent + one ReadAsync + N DecodeValueAt calls), ReadSingleAsync handles each fallback (the pre-#194 per-tag path, now extracted + threaded through). A per-group failure stamps the mapped libplctag status across every grouped member only — sibling groups + fallback refs are unaffected. Health-surface updates happen once per successful group rather than once per member to avoid ping-ponging the DriverState bookkeeping. Five AbCipUdtMemberLayoutTests: packed atomics get natural-alignment offsets including 8-byte pad before LInt; SInts pack without padding; BOOL/String/Structure opt out + return null; empty member list returns null. Six AbCipUdtReadPlannerTests: two members group; single-member demotes to fallback; unknown references fall back without poisoning groups; atomic top-level tags fall back untouched; UDTs containing BOOL don't group; original indices survive out-of-order batches. Five AbCipDriverWholeUdtReadTests (real driver + fake runtime): two grouped members trigger exactly one parent read + one fake runtime (proving the optimization engages); each member decodes at its own offset via ValuesByOffset; parent-read non-zero status stamps Bad across the group; mixed UDT-member + atomic top-level batch produces 2 runtimes + 2 reads (not 3); single-member-of-UDT still uses the member-level runtime (proving demotion works). Driver builds 0 errors; AbCip.Tests 227/227 (was 211, +16 new).
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#158 2026-04-20 04:19:53 -04:00
AbCip whole-UDT read optimization (#194)
dohertj2 created pull request dohertj2/lmxopcua#158 2026-04-20 04:19:44 -04:00
AbCip whole-UDT read optimization (#194)
dohertj2 created branch abcip-whole-udt-read in dohertj2/lmxopcua 2026-04-20 04:19:44 -04:00
dohertj2 pushed to abcip-whole-udt-read at dohertj2/lmxopcua 2026-04-20 04:19:44 -04:00
780358c790 AbCip whole-UDT read optimization (#194) — declaration-driven member grouping collapses N per-member reads into one parent-UDT read + client-side decode. Closes task #194. On a batch that includes multiple members of the same hand-declared UDT tag, ReadAsync now issues one libplctag read on the parent + decodes each member from the runtime's buffer at its computed byte offset. A 6-member Motor UDT read goes from 6 libplctag round-trips to 1 — the Rockwell-suggested pattern for minimizing CIP request overhead on batch reads of UDT state (decision #11's follow-through on what the template decoder from task #179 was meant to enable). AbCipUdtMemberLayout is a pure-function helper that computes declared-member byte offsets under Logix natural-alignment rules (SInt 1-byte / Int 2-byte / DInt + Real + Dt 4-byte / LInt + ULInt + LReal 8-byte; alignment pad inserted before each member as needed). Opts out for BOOL / String / Structure members — BOOL storage in Logix UDTs packs into a hidden host byte whose position can't be computed from declaration-only info, and String members need length-prefix + STRING[82] fan-out which libplctag already handles via a per-tag DecodeValue path. The CIP Template Object shape from task #179 (when populated via FetchUdtShapeAsync) carries real offsets for those members — layering that richer path on top of the planner is a separate follow-up and does not change this PR's conservative behaviour. AbCipUdtReadPlanner is the scheduling function ReadAsync consults each batch — pure over (requests, tagsByName), emits Groups + Fallbacks. A group is formed when (a) the reference resolves to "parent.member"; (b) parent is a Structure tag with declared Members; (c) the layout helper succeeds on those members; (d) the specific member appears in the computed offset map; (e) at least two members of the same parent appear in the batch — single-member groups demote to the fallback path because one whole-UDT read vs one per-member read is equivalent cost but more client-side work. Original batch indices are preserved through the plan so out-of-order batches write decoded values back at the right output slot; the caller's result array order is invariant. IAbCipTagRuntime.DecodeValueAt(AbCipDataType, int offset, int? bitIndex) is the new hot-path method — LibplctagTagRuntime delegates to libplctag's offset-aware Get*(offset) calls (GetInt32, GetFloat32, etc.) that were always there; previously every call passed offset 0. DecodeValue(type, bitIndex) stays as the shorthand + forwards to DecodeValueAt with offset 0, preserving the existing single-tag read path + every test that exercises it. FakeAbCipTag gains a ValuesByOffset dictionary so tests can drive multi-member decoding by setting offset→value before the read fires; unmapped offsets fall back to the existing Value field so the 200+ existing tests that never set ValuesByOffset keep working unchanged. AbCipDriver.ReadAsync refactored: planner splits the batch, ReadGroupAsync handles each UDT group (one EnsureTagRuntimeAsync on the parent + one ReadAsync + N DecodeValueAt calls), ReadSingleAsync handles each fallback (the pre-#194 per-tag path, now extracted + threaded through). A per-group failure stamps the mapped libplctag status across every grouped member only — sibling groups + fallback refs are unaffected. Health-surface updates happen once per successful group rather than once per member to avoid ping-ponging the DriverState bookkeeping. Five AbCipUdtMemberLayoutTests: packed atomics get natural-alignment offsets including 8-byte pad before LInt; SInts pack without padding; BOOL/String/Structure opt out + return null; empty member list returns null. Six AbCipUdtReadPlannerTests: two members group; single-member demotes to fallback; unknown references fall back without poisoning groups; atomic top-level tags fall back untouched; UDTs containing BOOL don't group; original indices survive out-of-order batches. Five AbCipDriverWholeUdtReadTests (real driver + fake runtime): two grouped members trigger exactly one parent read + one fake runtime (proving the optimization engages); each member decodes at its own offset via ValuesByOffset; parent-read non-zero status stamps Bad across the group; mixed UDT-member + atomic top-level batch produces 2 runtimes + 2 reads (not 3); single-member-of-UDT still uses the member-level runtime (proving demotion works). Driver builds 0 errors; AbCip.Tests 227/227 (was 211, +16 new).
dohertj2 deleted branch equipment-content-wiring from dohertj2/lmxopcua 2026-04-20 03:52:39 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 03:52:34 -04:00
1ac87f1fac Merge pull request 'ADR-001 last-mile � Program.cs composes walker into production boot (#214)' (#157) from equipment-content-wiring into v2
432173c5c4 ADR-001 last-mile — Program.cs composes EquipmentNodeWalker into the production boot path. Closes task #214 + fully lands ADR-001 Option A as a live code path, not just a connected set of unit-tested primitives. After this PR a server booted against a real Config DB with Published Equipment rows materializes the UNS tree into the OPC UA address space on startup — the whole walker → wire-in → loader chain (PRs #153, #154, #155, #156) finally fires end-to-end in the production process. DriverEquipmentContentRegistry is the handoff between OpcUaServerService's bootstrap-time populate pass + OpcUaApplicationHost's StartAsync walker invocation. It's a singleton mutable holder with Get/Set/Count + Lock-guarded internal dictionary keyed OrdinalIgnoreCase to match the DriverInstanceId convention used by Equipment / Tag rows + walker grouping. Set-once-per-bootstrap semantics in practice though nothing enforces that at the type level — OpcUaServerService.PopulateEquipmentContentAsync is the only expected writer. Shared-mutable rather than immutable-passed-by-value because the DI graph builds OpcUaApplicationHost before NodeBootstrap has resolved the generation, so the registry must exist at compose time + fill at boot time. Program.cs now registers OpcUaApplicationHost via a factory lambda that threads registry.Get as the equipmentContentLookup delegate PR #155 added to the ctor seam — the one-line composition the earlier PR promised. EquipmentNamespaceContentLoader (from PR #156) is AddScoped since it takes the scoped OtOpcUaConfigDbContext; the populate pass in OpcUaServerService opens one IServiceScopeFactory scope + reuses the same loader + DbContext across every driver query rather than scoping-per-driver. OpcUaServerService.ExecuteAsync gets a new PopulateEquipmentContentAsync step between bootstrap + StartAsync: iterates DriverHost.RegisteredDriverIds, calls loader.LoadAsync per driver at the bootstrapped generationId, stashes non-null results in the registry. Null results are skipped — the wire-in's null-check treats absent registry entries as "this driver isn't Equipment-kind; let DiscoverAsync own the address space" which is the correct backward-compat path for Modbus / AB CIP / TwinCAT / FOCAS. Guarded on result.GenerationId being non-null — a fleet with no Published generation yet boots cleanly into a UNS-less address space and fills the registry on the next restart after first publish. Ctor on OpcUaServerService gained two new dependencies (DriverEquipmentContentRegistry + IServiceScopeFactory). No test file constructs OpcUaServerService directly so no downstream test breakage — the BackgroundService is only wired via DI in Program.cs. Four new DriverEquipmentContentRegistryTests: Get-null-for-unknown, Set-then-Get, case-insensitive driver-id lookup, Set-overwrites-existing. Server.Tests 190/190 (was 186, +4 new registry tests). Full ADR-001 Option A now lives at every layer: Core.OpcUa walker (#153) → ScopePathIndexBuilder (#154) → OpcUaApplicationHost wire-in (#155) → EquipmentNamespaceContentLoader (#156) → this PR's registry + Program.cs composition. The last pending loose end (full-integration smoke test that boots Program.cs against a seeded Config DB + verifies UNS tree via live OPC UA client) isn't strictly necessary because PR #155's OpcUaEquipmentWalkerIntegrationTests already proves the wire-in at the OPC UA client-browse level — the Program.cs composition added here is purely mechanical + well-covered by the four-file audit trail plus registry unit tests.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#157 2026-04-20 03:52:32 -04:00
ADR-001 last-mile � Program.cs composes walker into production boot (#214)
dohertj2 created branch equipment-content-wiring in dohertj2/lmxopcua 2026-04-20 03:52:24 -04:00
dohertj2 pushed to equipment-content-wiring at dohertj2/lmxopcua 2026-04-20 03:52:24 -04:00
432173c5c4 ADR-001 last-mile — Program.cs composes EquipmentNodeWalker into the production boot path. Closes task #214 + fully lands ADR-001 Option A as a live code path, not just a connected set of unit-tested primitives. After this PR a server booted against a real Config DB with Published Equipment rows materializes the UNS tree into the OPC UA address space on startup — the whole walker → wire-in → loader chain (PRs #153, #154, #155, #156) finally fires end-to-end in the production process. DriverEquipmentContentRegistry is the handoff between OpcUaServerService's bootstrap-time populate pass + OpcUaApplicationHost's StartAsync walker invocation. It's a singleton mutable holder with Get/Set/Count + Lock-guarded internal dictionary keyed OrdinalIgnoreCase to match the DriverInstanceId convention used by Equipment / Tag rows + walker grouping. Set-once-per-bootstrap semantics in practice though nothing enforces that at the type level — OpcUaServerService.PopulateEquipmentContentAsync is the only expected writer. Shared-mutable rather than immutable-passed-by-value because the DI graph builds OpcUaApplicationHost before NodeBootstrap has resolved the generation, so the registry must exist at compose time + fill at boot time. Program.cs now registers OpcUaApplicationHost via a factory lambda that threads registry.Get as the equipmentContentLookup delegate PR #155 added to the ctor seam — the one-line composition the earlier PR promised. EquipmentNamespaceContentLoader (from PR #156) is AddScoped since it takes the scoped OtOpcUaConfigDbContext; the populate pass in OpcUaServerService opens one IServiceScopeFactory scope + reuses the same loader + DbContext across every driver query rather than scoping-per-driver. OpcUaServerService.ExecuteAsync gets a new PopulateEquipmentContentAsync step between bootstrap + StartAsync: iterates DriverHost.RegisteredDriverIds, calls loader.LoadAsync per driver at the bootstrapped generationId, stashes non-null results in the registry. Null results are skipped — the wire-in's null-check treats absent registry entries as "this driver isn't Equipment-kind; let DiscoverAsync own the address space" which is the correct backward-compat path for Modbus / AB CIP / TwinCAT / FOCAS. Guarded on result.GenerationId being non-null — a fleet with no Published generation yet boots cleanly into a UNS-less address space and fills the registry on the next restart after first publish. Ctor on OpcUaServerService gained two new dependencies (DriverEquipmentContentRegistry + IServiceScopeFactory). No test file constructs OpcUaServerService directly so no downstream test breakage — the BackgroundService is only wired via DI in Program.cs. Four new DriverEquipmentContentRegistryTests: Get-null-for-unknown, Set-then-Get, case-insensitive driver-id lookup, Set-overwrites-existing. Server.Tests 190/190 (was 186, +4 new registry tests). Full ADR-001 Option A now lives at every layer: Core.OpcUa walker (#153) → ScopePathIndexBuilder (#154) → OpcUaApplicationHost wire-in (#155) → EquipmentNamespaceContentLoader (#156) → this PR's registry + Program.cs composition. The last pending loose end (full-integration smoke test that boots Program.cs against a seeded Config DB + verifies UNS tree via live OPC UA client) isn't strictly necessary because PR #155's OpcUaEquipmentWalkerIntegrationTests already proves the wire-in at the OPC UA client-browse level — the Program.cs composition added here is purely mechanical + well-covered by the four-file audit trail plus registry unit tests.