Block a user
Remove native-launcher fallbacks; Docker is the only path for Modbus / S7 / AB CIP / OpcUaClient
Remove native-launcher fallbacks; Docker is the only path for Modbus / S7 / AB CIP / OpcUaClient
docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.
Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility
docker compose up. Modbus — new tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + pymodbus[simulator]==3.13.0) + docker-compose.yml with four compose profiles (standard / dl205 / mitsubishi / s7_1500) backed by the existing profile JSONs copied under Docker/profiles/ as canonical; native fallback in Pymodbus/ retained with the same JSON set (symlink-equivalent — manual re-sync when profiles change, noted in both READMEs). Port 5020 unchanged so MODBUS_SIM_ENDPOINT + ModbusSimulatorFixture work without code change. Dropped the --no_http CLI arg the old serve.ps1 + compose draft passed — pymodbus 3.13 doesn't recognize it; the simulator's http ui just binds inside the container where nothing maps it out and costs nothing. S7 — new tests/ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests/Docker/ with Dockerfile (python:3.12-slim-bookworm + python-snap7>=2.0) + docker-compose.yml with one s7_1500 compose profile; copies the existing server.py shim + s7_1500.json seed profile; runs python -u server.py ... --port 1102. Native fallback in PythonSnap7/ retained. Port 1102 unchanged. AB CIP — hardest because ab_server is a source-only C tool in libplctag's src/tools/ab_server/. New tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests/Docker/ Dockerfile is multi-stage: build stage (debian:bookworm-slim + build-essential + cmake) clones libplctag at a pinned tag + cmake --build build --target ab_server; runtime stage (debian:bookworm-slim) copies just the binary from /src/build/bin_dist/ab_server. docker-compose.yml ships four compose profiles (controllogix / compactlogix / micro800 / guardlogix) with per-family ab_server CLI args matching AbServerProfile.cs. AbServerFixture updated: tries TCP probe on 127.0.0.1:44818 first (Docker path) + spawns the native binary only as fallback when no listener is there. AB_SERVER_ENDPOINT env var supported for pointing at a real PLC. AbServerFact/Theory attributes updated to IsServerAvailable() which accepts any of: live listener on 44818, AB_SERVER_ENDPOINT set, or binary on PATH. Required two CLI-compat fixes to ab_server's argument expectations that the existing native profile never caught because it was never actually run at CI: --plc is case-sensitive (ControlLogix not controllogix), CIP tags need [size] bracket notation (DINT[1] not bare DINT), ControlLogix also requires --path=1,0. Compose files carry the corrected flags; the existing native-path AbServerProfile.cs was never invoked in practice so we don't rewrite it here. Micro800 now uses the --plc=Micro800 mode rather than falling back to ControlLogix emulation — ab_server does have the dedicated mode, the old Notes saying otherwise were wrong. Updated docs: three fixture coverage docs (Modbus-Test-Fixture.md, S7-Test-Fixture.md, AbServer-Test-Fixture.md) flip their "What the fixture is" section from native-only to Docker-primary-with-native-fallback; dev-environment.md §Resource Inventory replaces the old ambiguous "Docker Desktop + ab_server native" mix with four per-driver rows (each listing the image, compose file, compose profiles, port, credentials) + a new Docker fixtures — quick reference subsection giving the one-line docker compose -f <…> --profile <…> up for each driver + the env-var override names + the native fallback install recipes. drivers/README.md coverage map table updated — Modbus/AB CIP/S7 entries now read "Dockerized …" consistent with OpcUaClient's line. Verified end-to-end against live containers: Modbus DL205 smoke 1/1, S7 3/3, AB CIP ControlLogix 4/4 (all family theory rows). Container lifecycle clean (up/test/down, no leaked state). Every fixture keeps its skip-when-absent probe + env-var endpoint override so dotnet test on a fresh clone without Docker running still gets a green run.
Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility
dohertj2
deleted branch opcuaclient-opc-plc-fixture from dohertj2/lmxopcua
2026-04-20 11:45:35 -04:00
docker ps surfaces ready state. Fixture OpcPlcFixture follows the same shape as Snap7ServerFixture + ModbusSimulatorFixture: collection-scoped, parses OPCUA_SIM_ENDPOINT (default opc.tcp://localhost:50000) into host + port, 2-second TCP probe at init, SkipReason records the failure for Assert.Skip. Forced IPv4 on the probe socket for the same reason those two fixtures do — .NET's dual-stack "localhost" resolves IPv6 ::1 first + hangs the full connect timeout when the target binds 0.0.0.0 (IPv4). OpcPlcProfile holds well-known node identifiers opc-plc exposes (ns=3;s=StepUp, FastUInt1, RandomSignedInt32, AlternatingBoolean) + builds OpcUaClientDriverOptions with SecurityPolicy.None + AutoAcceptCertificates=true since opc-plc regenerates its server cert on every container spin-up + there's no meaningful chain to validate against in CI. Three smoke tests covering what the unit suite couldn't reach: (1) Client_connects_and_reads_StepUp_node_through_real_OPC_UA_stack — full Secure Channel + Session + Read on ns=3;s=StepUp (counter that ticks every 1 s); (2) Client_reads_batch_of_varied_types_from_live_simulator — batch Read of UInt32 / Int32 / Boolean to prove typed Variant decoding, with an explicit ShouldBeOfType<bool> assertion on AlternatingBoolean to catch the common "variant gets stringified" regression; (3) Client_subscribe_receives_StepUp_data_changes_from_live_server — real MonitoredItem subscription on FastUInt1 (100 ms cadence) with a SemaphoreSlim gate + 3 s deadline on the first OnDataChange fire, tolerating container warm-up. Driver ran end-to-end against a live 2.14.10 container: all 3 pass; unit suite 78/78 unchanged. Container lifecycle verified (compose up → tests → compose down) clean, no leaked state. Docker/README.md documents install (Docker Desktop already on the dev box per Phase 1 decision #134), run (compose up / compose up -d / compose down), endpoint override (OPCUA_SIM_ENDPOINT), what opc-plc advertises with the current command flags, what's tunable via compose-file tweaks (--daa for username auth tests; --fn/--fr/--ft for subscription-stress nodes), known limitation that opc-plc shares the OPCFoundation stack with our driver. OpcUaClient-Test-Fixture.md updated — TL;DR flipped from "there is no integration fixture" to the new reality; "What it actually covers" gains an Integration section listing the three smoke tests. Follow-up the doc flags: add open62541/open62541 as a second image for fully-independent-stack interop coverage; once #219 (server-side IAlarmSource/IHistoryProvider integration tests) lands, re-run the client-side suite against opc-plc's --alm nodes to close the alarm gap from the client side too.
OpcUaClient integration fixture � opc-plc in Docker (#215)
docker ps surfaces ready state. Fixture OpcPlcFixture follows the same shape as Snap7ServerFixture + ModbusSimulatorFixture: collection-scoped, parses OPCUA_SIM_ENDPOINT (default opc.tcp://localhost:50000) into host + port, 2-second TCP probe at init, SkipReason records the failure for Assert.Skip. Forced IPv4 on the probe socket for the same reason those two fixtures do — .NET's dual-stack "localhost" resolves IPv6 ::1 first + hangs the full connect timeout when the target binds 0.0.0.0 (IPv4). OpcPlcProfile holds well-known node identifiers opc-plc exposes (ns=3;s=StepUp, FastUInt1, RandomSignedInt32, AlternatingBoolean) + builds OpcUaClientDriverOptions with SecurityPolicy.None + AutoAcceptCertificates=true since opc-plc regenerates its server cert on every container spin-up + there's no meaningful chain to validate against in CI. Three smoke tests covering what the unit suite couldn't reach: (1) Client_connects_and_reads_StepUp_node_through_real_OPC_UA_stack — full Secure Channel + Session + Read on ns=3;s=StepUp (counter that ticks every 1 s); (2) Client_reads_batch_of_varied_types_from_live_simulator — batch Read of UInt32 / Int32 / Boolean to prove typed Variant decoding, with an explicit ShouldBeOfType<bool> assertion on AlternatingBoolean to catch the common "variant gets stringified" regression; (3) Client_subscribe_receives_StepUp_data_changes_from_live_server — real MonitoredItem subscription on FastUInt1 (100 ms cadence) with a SemaphoreSlim gate + 3 s deadline on the first OnDataChange fire, tolerating container warm-up. Driver ran end-to-end against a live 2.14.10 container: all 3 pass; unit suite 78/78 unchanged. Container lifecycle verified (compose up → tests → compose down) clean, no leaked state. Docker/README.md documents install (Docker Desktop already on the dev box per Phase 1 decision #134), run (compose up / compose up -d / compose down), endpoint override (OPCUA_SIM_ENDPOINT), what opc-plc advertises with the current command flags, what's tunable via compose-file tweaks (--daa for username auth tests; --fn/--fr/--ft for subscription-stress nodes), known limitation that opc-plc shares the OPCFoundation stack with our driver. OpcUaClient-Test-Fixture.md updated — TL;DR flipped from "there is no integration fixture" to the new reality; "What it actually covers" gains an Integration section listing the three smoke tests. Follow-up the doc flags: add open62541/open62541 as a second image for fully-independent-stack interop coverage; once #219 (server-side IAlarmSource/IHistoryProvider integration tests) lands, re-run the client-side suite against opc-plc's --alm nodes to close the alarm gap from the client side too.
OpcUaClient integration fixture � opc-plc in Docker (#215)
S7 integration fixture via python-snap7 (#216) + per-driver test-fixture coverage docs