# NAM AD requests: accounts and groups
Everything the family needs **created or confirmed in NAM Active Directory** (`nam.zimmer.com`) for the NAM LDAP
cutover and the related issues, broken out by environment and app. Use this file when raising ServiceNow/IT tickets.
- Plan: [`docs/plans/2026-11-15-nam-ldap-cutover.md`](docs/plans/2026-11-15-nam-ldap-cutover.md)
- Matrix: [`ldap_mapping.md`](ldap_mapping.md)
- Directory facts and 08-12 counts: [`ldap_setup.md`](ldap_setup.md)
- Umbrella: scadaproj#6
**Status as of 2026-11-17: nothing requested yet.** Names marked *(proposed)* are our suggestion; IT's naming
convention wins.
**Environments:**
- **DEV** = wonder-app-vd03.
- **QA** = wonder-app-vq03/vq04.
- **PROD** = no production box has been identified yet (`deployment.md`). The current cutover plan covers DEV
and QA only, so the PROD rows are **planned and provisional**: request them when a PROD deployment is
scheduled, or together with DEV/QA if IT prefers one ticket.
**Separation rule:**
- PROD gets **its own accounts**. A non-production mistake (a mistyped secret, a lockout, a leaked
credential) must not reach PROD.
- Each deployment maps **only its own group suffix** (`_DEV`/`_QA`/`_PROD`; `ldap_mapping.md` §3).
## 1. New accounts
| # | Account | Type | Env | Used by | Purpose | Required access | Password and policy | Blocks | Issue |
|---|---|---|---|---|---|---|---|---|---|
| A1 | `svc_zbmomww` *(proposed)* | Service account (LDAP lookup) | **DEV + QA**, shared (per-tier only if IT prefers) | OtOpcUa, ScadaBridge, MxAccessGateway, HistorianGateway | Service bind for user search and group reads at login; ScadaBridge group refresh (#46) | **Read-only** search of users (`sAMAccountName`, `userPrincipalName`, `displayName`, `memberOf`) and `UG_WW_*` groups. No interactive or RDP logon. LDAPS 636 to nam1/nam2 | Non-expiring, or managed rotation with notice. **No lockout**, or a very high threshold: one bad secret costs 2 binds per login across 4 apps × 2 tiers | QA cutover (all apps). DEV can run on `svc_igntadmin` as an interim, **only with the Ignition team's agreement** | scadaproj#58 |
| A1P | `svc_zbmomww_prod` *(proposed)* | Service account (LDAP lookup) | **PROD** | Same four apps | Same as A1, for PROD | Same as A1 | Same as A1. **Never shared with DEV/QA** | PROD cutover (all apps) | scadaproj#58 (extend) |
| A2 | `svc_zbmomww_auto_dev` *(proposed)* | **User-type** identity (interactive sign-in) | DEV | ScadaBridge CLI, deploy scripts, drills; OtOpcUa scripts if DEV AdminUI login is on | Replaces the login-off dev user once DEV login turns on | Member of `UG_WW_APP_ADMIN_DEV`, `UG_WW_APP_IDE_DEV` and `UG_WW_APP_DEPLOY_DEV` | Non-expiring or managed; stored in the Mac Keychain only | DEV ScadaBridge step (plan D3). Interim: a named admin's own account | scadaproj#6 (D3) |
| A3 | `svc_zbmomww_auto_qa` *(proposed)* | **User-type** identity (interactive sign-in) | QA | Same as A2 | Replaces the GLAuth `multi-role` user on QA | Member of `UG_WW_APP_ADMIN_QA`, `UG_WW_APP_IDE_QA` and `UG_WW_APP_DEPLOY_QA` | As A2 | QA ScadaBridge step (plan D3) | scadaproj#6 (D3) |
| A3P | `svc_zbmomww_auto_prod` *(proposed)* | **User-type** identity (interactive sign-in) | PROD | Deploy and verify automation, if PROD automation is allowed | PROD deploys run as a named identity, not a person | Member of `UG_WW_APP_DEPLOY_PROD`, plus `UG_WW_APP_IDE_PROD` only if automation authors config there. **Not `APP_ADMIN_PROD`** unless the owner decides otherwise | As A2; a tighter rotation is recommended | PROD ScadaBridge deploys. **Owner decision:** whether PROD allows an automation identity at all | scadaproj#6 (D3, PROD extension) |
| A4 | `svc_zbhistgw` *(proposed)* | Service account (**AVEVA Historian**, not LDAP) | DEV + QA, shared or one per tier | HistorianGateway → Historian gRPC (`wonder-sql-vd03`, `wonder-sql-vq03`) | Replaces the personal `NAM\dohertj2` that DEV and QA use today | Historian read/write on the DEV and QA Historian hosts | Non-expiring or managed; stored as `${secret:}` in HG's store | Not the cutover. A personal-account outage breaks DEV and QA historian access together | historiangw#134 |
| A4P | `svc_zbhistgw_prod` *(proposed)* | Service account (**AVEVA Historian**) | PROD | HistorianGateway → PROD Historian | Same as A4, for PROD | Historian access on the PROD Historian host (read/write only if PROD historization writes are in scope) | As A4. **Never shared with DEV/QA** | A PROD HistorianGateway deployment | historiangw#134 (extend) |
The LDAP-lookup accounts (A1/A1P) must not double as sign-in identities (A2/A3/A3P) unless IT agrees.
## 2. New groups
| # | Group | Env | App | Role granted | Why it's needed | Initial members | Blocks | Issue |
|---|---|---|---|---|---|---|---|---|
| G1 | `UG_WW_APP_DEPLOY_DEV` *(proposed)* | DEV | ScadaBridge | `Deployer` | One group = one role, and ScadaBridge `Administrator` does **not** include `Deployer`. Without it, no NAM user can deploy | Deployers on DEV + A2 | DEV ScadaBridge cutover | scadaproj#6 (D6) |
| G2 | `UG_WW_APP_DEPLOY_QA` *(proposed)* | QA | ScadaBridge | `Deployer` | Same as G1 | Deployers on QA + A3 | QA ScadaBridge cutover | scadaproj#6 (D6) |
| G3 | `UG_WW_APP_DEPLOY_PROD` *(proposed)* | PROD | ScadaBridge | `Deployer` | Same as G1. In PROD it should be the **smallest** group: the people (and A3P) allowed to change production | Named PROD deployers (owner to list) + A3P | PROD ScadaBridge cutover | scadaproj#6 (D6) |
## 3. Existing groups to confirm (membership and exact name)
All existed on 2026-08-12, with the member counts shown (DEV / QA / PROD, from `ldap_setup.md`). They are
unverified since. **Confirm the exact spelling and case** (HistorianGateway matches case-sensitively until
historiangw#136 ships) and **who is in each**. A user in none of them can't log in to any app.
| Group family | OtOpcUa | ScadaBridge | MxAccessGateway | HistorianGateway | DEV | QA | PROD |
|---|---|---|---|---|---|---|---|
| `UG_WW_APP_ADMIN_<T>` | Administrator | Administrator | Administrator | Administrator | 7 | 6 | 5 |
| `UG_WW_APP_IDE_<T>` | Designer | Designer | Viewer | — | 6 | 6 | 4 |
| `UG_WW_APP_IDE_RO_<T>` | Viewer | Viewer | Viewer | Viewer | 2 | 1 | 1 |
| `UG_WW_HIST_ADMIN_<T>` | Viewer | — | — | Administrator | 7 | 6 | 4 |
| `UG_WW_BTMGR_RO_<T>` | — | Viewer | — | Viewer | *(no group)* | **0 (empty)** | 4 |
`<T>` is the deployment's own suffix: `DEV`, `QA` or `PROD`.
**PROD review:** the PROD groups were built for AVEVA System Platform. Mapping them means their members gain
these apps' roles in PROD too. For example, all 5 `APP_ADMIN_PROD` members become Administrator in every app. The
owner should confirm each PROD membership list before the PROD mapping, not just the group names.
Out of scope for this cutover:
- `UG_WW_CITRIX_*` is never mapped. It is desktop/session access; DEV and QA groups exist, there is no PROD group.
- Plant-floor, site and batch groups (`*_OPERATOR`, `*_ENGINEER`, `SITE_ADMIN_*`, `BTMGR_{BE,MC}_*`, …)
(`ldap_mapping.md` §4.2).
To check one person or a group family: `tools/LdapProbe` (plan §5 D7), for example `-g 'UG_WW_*'`.
## 4. Summary by environment
| Env | Hosts | New accounts | New groups | Groups to confirm | When |
|---|---|---|---|---|---|
| **DEV** | wonder-app-vd03 | A1 (shared with QA), A2, A4 (shared with QA or DEV-only) | G1 | `APP_ADMIN_DEV`, `APP_IDE_DEV`, `APP_IDE_RO_DEV`, `HIST_ADMIN_DEV` | Now (cutover plan) |
| **QA** | wonder-app-vq03 / vq04 | A1 (shared with DEV), A3, A4 (shared with DEV or QA-only) | G2 | `APP_ADMIN_QA`, `APP_IDE_QA`, `APP_IDE_RO_QA`, `HIST_ADMIN_QA`, `BTMGR_RO_QA` (empty) | Now (cutover plan) |
| **PROD** | **not identified** | A1P, A3P (if allowed), A4P | G3 | `APP_ADMIN_PROD`, `APP_IDE_PROD`, `APP_IDE_RO_PROD`, `HIST_ADMIN_PROD`, `BTMGR_RO_PROD`, **plus a membership review** | When a PROD deployment is scheduled |
## 5. Summary by app
The same pattern applies in every environment; `<T>` is `DEV`, `QA` or `PROD`.
| App | LDAP-lookup account | Sign-in / automation account | Other account | Groups it maps (per env) |
|---|---|---|---|---|
| **OtOpcUa** (AdminUI) | A1 (DEV/QA), A1P (PROD) | A2/A3/A3P for scripts if login is on | — | `APP_ADMIN_<T>`, `APP_IDE_<T>`, `APP_IDE_RO_<T>`, `HIST_ADMIN_<T>` |
| **ScadaBridge** (Central UI, CLI) | A1 / A1P (login + group refresh) | A2 / A3 / A3P (CLI and automation) | — | `APP_ADMIN_<T>`, `APP_IDE_<T>`, **`APP_DEPLOY_<T>` (new)**, `APP_IDE_RO_<T>`, `BTMGR_RO_<T>` (QA/PROD) |
| **MxAccessGateway** (dashboard) | A1 / A1P | — | — | `APP_ADMIN_<T>`, `APP_IDE_<T>`, `APP_IDE_RO_<T>` |
| **HistorianGateway** (dashboard + Historian) | A1 / A1P (dashboard login) | — | A4 / A4P (Historian data access) | `APP_ADMIN_<T>`, `APP_IDE_RO_<T>`, `HIST_ADMIN_<T>`, `BTMGR_RO_<T>` (QA/PROD) |
| Overview | none (no login by design) | — | — | none |
## 6. Ticket checklist
| Ticket | Contents | Env | Tracked in |
|---|---|---|---|
| T1 | A1: LDAP-lookup service account, no lockout | DEV + QA | scadaproj#58 |
| T2 | A2 + A3: automation sign-in identities, with group memberships | DEV, QA | scadaproj#6 D3 |
| T3 | G1 + G2: `UG_WW_APP_DEPLOY_{DEV,QA}` | DEV, QA | scadaproj#6 D6 |
| T4 | A4: Historian service account | DEV + QA | historiangw#134 |
| T5 | Membership confirmation for the existing DEV/QA groups | DEV, QA | scadaproj#6 D7 |
| T6 *(later)* | A1P, A3P, A4P, G3, plus the PROD membership review | PROD | not filed yet; raise when PROD is scheduled |