Files
network/ha.md
T
dohertj2 1424f9469e Configure HA Energy dashboard (grid + water); add Aeotec HEM8 manuals
Grid now uses PowerMonitorMain (Aeotec ZWA046) per leg since clamp 1 is
reversed; water uses the Droplet integral sensor with flow rate. Refresh
HA version and entity counts.
2026-10-01 09:20:15 -04:00

77 lines
4.1 KiB
Markdown

# Home Assistant
## Access
- **Hostname**: HA
- **IP**: 10.100.0.40 (LAN_100)
- **OS**: Home Assistant OS (reports as Oracle Linux 6 to ESXi)
- **Web UI**: http://10.100.0.40:8123 / https://ha.dohertylan.com
- **SSH**: Not available (Home Assistant OS — no direct shell access from this machine)
- **API Token**: `eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiI3MDU4MDcwNWNjOTI0MmE5YTg1OTJmMWRmMWY0YTk5NSIsImlhdCI6MTc3MTE4NzM0NCwiZXhwIjoyMDg2NTQ3MzQ0fQ.RXzwb_xu9TQyIE2QABRJP5nXtb6FDyHY7Phu3vFJecw`
## Hardware (VM on ESXi)
- **CPU**: 16 vCPUs (Intel Xeon E5-2697 v4 @ 2.30GHz)
- **RAM**: 16 GB (12.5 GB host usage, ~1.1 GB guest active)
- **Disk**: 128 GB (AHCI/SATA, datastore NVME_1)
- **Boot time**: 2026-02-17
## Network
| NIC | Type | MAC | Port Group | IP |
|-----|------|-----|------------|-----|
| ethernet-1 | vmxnet3 | 00:0c:29:f3:f3:5b | LAN_100 | 10.100.0.40/24 |
- Single NIC (LAN_100 only, no DATA_50)
## Home Assistant
- **Version**: 2026.9.4 (verified 2026-10-01)
- **State**: RUNNING
- **Location**: Syracuse, IN (41.41, -85.72)
- **Time zone**: America/New_York
- **Units**: Imperial (US)
### Scale
- **2,613 entities** across 80 service domains (804 unavailable as of 2026-10-01 — 289 are stale `new_*` entities)
- Top entity types: sensor (866), switch (297), number (283), button (251), binary_sensor (232), select (161), device_tracker (133), light (94)
### Key Integrations
| Category | Integrations |
|----------|-------------|
| **Z-Wave / Zigbee / Matter** | zwave_js, matter |
| **MQTT / ESPHome / Tasmota** | mqtt, esphome, tasmota |
| **WiFi Devices** | shelly, yolink, ac_infinity, flair, midea_dehumidifier_lan, govee_ble |
| **Appliances** | ge_home, roborock |
| **Media** | sonos, apple_tv, cast, harmony, webostv |
| **Network / Monitoring** | unifi, truenas, iotawatt, brother, ipp |
| **Protocols** | homekit, homekit_controller, modbus, bthome, ibeacon, oralb |
| **Voice / AI** | alexa, google_assistant, anthropic, openai_conversation, wyoming |
| **Other** | hacs, cloud, go2rtc, droplet, isy994 |
### Notable Devices
- **PowerMonitorMain** — Aeotec Home Energy Meter 8 (ZWA046), Z-Wave JS node 42, firmware 1.7.7. Entities `sensor.powermonitormain_*` (consumption/production W, kWh, V, A, PF, kVar per channel). Manuals in [manuals/](manuals/). 2-clamp version; endpoints: EP1/EP2 clamp 1 consumption/production, EP3/EP4 clamp 2, EP5/EP6 sum of clamps, EP7/EP8 net.
### Energy Dashboard
- **Grid** (configured 2026-10-01): two import entries, one per leg of PowerMonitorMain:
- Leg 2: `sensor.powermonitormain_electric_consumption_kwh_3` / power `..._consumption_w_3` (EP3, clamp 2 consumption)
- Leg 1: `sensor.powermonitormain_electric_production_kwh` / power `..._production_w` (EP2, clamp 1 "production") — **clamp 1 is installed reversed**, so leg 1 load reports as production (no solar; it reads all night). EP1 consumption has never registered. If clamp 1 is ever flipped, switch this entry to `sensor.powermonitormain_electric_consumption_kwh` (EP1), or replace both with EP5 (`..._consumption_kwh_5`, sum of clamps).
- Don't use EP7 (net consumption) — with a reversed clamp it subtracts leg 1 instead of adding it.
- Replaced `sensor.total_watts_wh` (old IoTaWatt, no longer reporting). Meter statistics begin 2026-09-30.
- **Water** (configured 2026-10-01): consumption `sensor.water_total_usage` (Riemann integral helper of the flow rate, gal, lifetime total; registry device_class override → `water`), flow rate `sensor.droplet_prefilter_flow_rate` (gal/min, `stat_rate`)
- Droplet (utility room, pre-filter): `sensor.droplet_daily_water_usage` / `sensor.droplet_monthly_water_usage` are utility_meter helpers on `sensor.water_total_usage`. Don't use `sensor.droplet_prefilter_water` — it is a per-interval delta that goes negative, not a total.
### Automations
- 24 automations configured
## Notes
- Home Assistant OS manages its own Docker containers internally — the Docker bridge (172.30.32.1) shown in ESXi docs is internal to HAOS
- govc guest operations don't work (HAOS doesn't use standard Linux auth)
- Backed up by Veeam via "Backup VMs" job