Remove IoTaWatt from Home Assistant docs

This commit is contained in:
dohertj2
2026-10-01 09:32:18 -04:00
parent 1424f9469e
commit 385f74ec5a
+2 -2
View File
@@ -46,7 +46,7 @@
| **WiFi Devices** | shelly, yolink, ac_infinity, flair, midea_dehumidifier_lan, govee_ble |
| **Appliances** | ge_home, roborock |
| **Media** | sonos, apple_tv, cast, harmony, webostv |
| **Network / Monitoring** | unifi, truenas, iotawatt, brother, ipp |
| **Network / Monitoring** | unifi, truenas, brother, ipp |
| **Protocols** | homekit, homekit_controller, modbus, bthome, ibeacon, oralb |
| **Voice / AI** | alexa, google_assistant, anthropic, openai_conversation, wyoming |
| **Other** | hacs, cloud, go2rtc, droplet, isy994 |
@@ -61,7 +61,7 @@
- Leg 2: `sensor.powermonitormain_electric_consumption_kwh_3` / power `..._consumption_w_3` (EP3, clamp 2 consumption)
- Leg 1: `sensor.powermonitormain_electric_production_kwh` / power `..._production_w` (EP2, clamp 1 "production") — **clamp 1 is installed reversed**, so leg 1 load reports as production (no solar; it reads all night). EP1 consumption has never registered. If clamp 1 is ever flipped, switch this entry to `sensor.powermonitormain_electric_consumption_kwh` (EP1), or replace both with EP5 (`..._consumption_kwh_5`, sum of clamps).
- Don't use EP7 (net consumption) — with a reversed clamp it subtracts leg 1 instead of adding it.
- Replaced `sensor.total_watts_wh` (old IoTaWatt, no longer reporting). Meter statistics begin 2026-09-30.
- Replaced `sensor.total_watts_wh` (old IoTaWatt at 10.100.0.62 — hardware removed; integration, device and 29 entities deleted from HA 2026-10-01). Meter statistics begin 2026-09-30.
- **Water** (configured 2026-10-01): consumption `sensor.water_total_usage` (Riemann integral helper of the flow rate, gal, lifetime total; registry device_class override → `water`), flow rate `sensor.droplet_prefilter_flow_rate` (gal/min, `stat_rate`)
- Droplet (utility room, pre-filter): `sensor.droplet_daily_water_usage` / `sensor.droplet_monthly_water_usage` are utility_meter helpers on `sensor.water_total_usage`. Don't use `sensor.droplet_prefilter_water` — it is a per-interval delta that goes negative, not a total.