Joseph Doherty ab41362a5c fix(IPC-35): surface a handshake-phase WorkerFault with its category and diagnostic
The worker reports startup failures as structured WorkerFault frames --
MxAccessCreationException carries the COM HRESULT/ProgID context and a
WorkerFaultCategory -- so the gateway can tell "MXAccess is not installed / not
registered / access denied" apart from a pipe-level protocol problem.
ReadHandshakeEnvelopeAsync did not look inside: any body other than the expected
one became a ProtocolViolation naming only the body type, and that text is what
SessionManager puts in the operator log and the client's OpenFailed detail. The
information was lost exactly in the window where it matters most -- first
session open on a freshly deployed host, where the answer is almost always an
MXAccess installation or permission problem.

Special-case BodyCase == WorkerFault and throw WorkerClientException(
WorkerFaulted, CreateWorkerFaultMessage(...)) -- the same formatter the
steady-state fault path already uses, so both windows read alike. Every other
unexpected body still gets ProtocolViolation.

Test: StartAsync_WhenWorkerFaultsDuringHandshake_SurfacesFaultCategoryAndDiagnostic
has the fake worker answer the hello and then write a WorkerFault
{MxaccessCreationFailed} in place of WorkerReady; the existing
FakeWorkerHarness.EmitFaultAsync covered it, so the harness needed no change.