Joseph Doherty 9e4be25807
ci / nightly-windev (push) Has been skipped
ci / windows-x86 (push) Successful in 2m23s
ci / java (push) Failing after 7m49s
ci / portable (push) Failing after 16m36s
test(live): capture OperationComplete trigger, subtag Clear and status rows on windev (#210, #211)
Live MXAccess captures against the windev DEV Galaxy, recorded in
docs/LiveCaptures-2026-11-13.md:

- OperationComplete follows a Suspend/Activate whose synchronous MxStatus is
  Pending (advised, resolved item); one Ok row from RespondingLmx. Pinned by
  the new OperationCompleteLiveProbeTests live fact, with an
  unresolved-reference negative control. (#211 §3.1)
- No public COM event carries completion-only status bytes. All 71
  completions were typed MXSTATUS_PROXY[], so they stay raw permanently.
  (#211 §3.3)
- Subtag-mode Clear is drivable: the TestAlarm UDAs are MxSecurityOperate,
  so AuthenticateUser + WriteSecured toggles them. The new self-driven
  LiveSubtag_SelfDrivenRaiseThenClear_SynthesizesClear fact asserts the
  UnackAlm -> UnackRtn Clear (mutation-checked). (#210 §3.7)
- The B8 buffered "NoData bootstrap" is a ConfigurationError resolution
  failure (detail 6 / 1002). The DEV Galaxy has no buffered attribute, so a
  multi-sample capture needs IDE work. provider_switches was not driven. (#210)
- Status-row catalogue for lmxopcua#872: no Warning row seen, and Pending
  only on the synchronous Suspend/Activate return.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-12 23:34:46 -05:00
S