Worker.Tests-003: removed the wall-clock `Elapsed < 2s` assertion from InvokeAsync_WakesIdlePumpForQueuedCommand; the awaited completion against a 30s idle period already proves the wake event drove dispatch. Worker.Tests-004: MxAccessStaSession.Dispose now joins the alarm poll task after cancelling the CTS (consistent with ShutdownGracefullyAsync), and Dispose_StopsAlarmPollLoop asserts deterministically instead of via Task.Delay. Worker.Tests-005: undisposed MemoryStream instances across the frame-protocol and pipe-session tests are now `using` declarations. Worker.Tests-006: Dispose_StopsAlarmPollLoop now constructs MxAccessStaSession with `using` so a failed assertion cannot leak the STA poll loop. Worker.Tests-007: docs/WorkerFrameProtocol.md verification section corrected to target MxGateway.Worker.Tests / MxGateway.Worker with -p:Platform=x86. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
60 lines
2.1 KiB
Markdown
60 lines
2.1 KiB
Markdown
# Worker Frame Protocol
|
|
|
|
The gateway uses the worker frame protocol to move `WorkerEnvelope` protobuf
|
|
messages over a bidirectional named pipe. The frame layer is deliberately small:
|
|
it handles message boundaries, size limits, protobuf parsing, and envelope
|
|
validation before higher-level worker client code routes commands, replies,
|
|
events, and faults.
|
|
|
|
## Frame Format
|
|
|
|
Each frame starts with a four-byte little-endian unsigned payload length,
|
|
followed by the serialized `WorkerEnvelope` payload:
|
|
|
|
```text
|
|
uint32 little-endian payload_length
|
|
payload_length bytes protobuf WorkerEnvelope
|
|
```
|
|
|
|
The reader rejects zero-length payloads and payloads larger than the configured
|
|
maximum before allocating the payload buffer. The default maximum is 16 MiB,
|
|
matching the gateway process design.
|
|
|
|
## Envelope Validation
|
|
|
|
`WorkerFrameReader` and `WorkerFrameWriter` validate each envelope against the
|
|
owning session before returning or writing it:
|
|
|
|
- `protocol_version` must match the configured worker protocol version,
|
|
- `session_id` must match the owning gateway session,
|
|
- the envelope must contain one typed `body` value.
|
|
|
|
Protocol violations throw `WorkerFrameProtocolException` with a
|
|
`WorkerFrameProtocolErrorCode` so callers can distinguish malformed frames,
|
|
oversized frames, protocol version mismatches, and session mismatches.
|
|
|
|
## Verification
|
|
|
|
The frame protocol lives in `MxGateway.Worker.Ipc` (`WorkerFrameReader`,
|
|
`WorkerFrameWriter`, `WorkerFrameProtocolOptions`) and is covered by
|
|
`src/MxGateway.Worker.Tests/Ipc/WorkerFrameProtocolTests.cs`. The worker is an
|
|
x86 process, so build and test it with `-p:Platform=x86`.
|
|
|
|
Run the focused tests after changing the frame protocol:
|
|
|
|
```powershell
|
|
dotnet test src/MxGateway.Worker.Tests/MxGateway.Worker.Tests.csproj -p:Platform=x86 --filter WorkerFrameProtocolTests
|
|
```
|
|
|
|
Run the x86 worker build because the frame protocol is part of
|
|
`MxGateway.Worker`:
|
|
|
|
```powershell
|
|
dotnet build src/MxGateway.Worker/MxGateway.Worker.csproj -p:Platform=x86
|
|
```
|
|
|
|
## Related Documentation
|
|
|
|
- [Gateway Process Detailed Design](./GatewayProcessDesign.md)
|
|
- [Protobuf Contracts](./Contracts.md)
|