2e52f9f5e8
The worker's heartbeat send interval (5 s) and its own STA-watchdog stuck ceiling (75 s) were compile-time defaults the gateway never reached, and nothing checked that the gateway's HeartbeatGraceSeconds exceeded the real send interval, so a misconfigured grace could kill healthy workers. - New MxGateway:Worker options WorkerHeartbeatSendIntervalSeconds (default 5) and WorkerHeartbeatStuckCeilingSeconds (default 75), exported by WorkerProcessLauncher as MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS and MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS, the same env-var path the other worker settings use. - The worker's production WorkerPipeSession reads them through WorkerPipeSessionOptions.FromEnvironment; a missing/invalid value, or a ceiling not above the worker's 15 s watchdog grace, keeps the default rather than failing the worker. - Startup validation: HeartbeatGraceSeconds > WorkerHeartbeatSendIntervalSeconds; send interval > 0; worker ceiling > 15 s; both at most 86400 s. - Docs: GatewayConfiguration, WorkerProcessLauncher (env table now also lists the previously missing MXGATEWAY_ALARM_ACK_CLIENT_NAME), worker design doc. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV