feat(gateway,worker): configurable worker heartbeat send interval and stuck ceiling (mxaccessgw#218)
The worker's heartbeat send interval (5 s) and its own STA-watchdog stuck
ceiling (75 s) were compile-time defaults the gateway never reached, and
nothing checked that the gateway's HeartbeatGraceSeconds exceeded the real send
interval, so a misconfigured grace could kill healthy workers.

- New MxGateway:Worker options WorkerHeartbeatSendIntervalSeconds (default 5)
  and WorkerHeartbeatStuckCeilingSeconds (default 75), exported by
  WorkerProcessLauncher as MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS and
  MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS, the same env-var path the other
  worker settings use.
- The worker's production WorkerPipeSession reads them through
  WorkerPipeSessionOptions.FromEnvironment; a missing/invalid value, or a
  ceiling not above the worker's 15 s watchdog grace, keeps the default rather
  than failing the worker.
- Startup validation: HeartbeatGraceSeconds > WorkerHeartbeatSendIntervalSeconds;
  send interval > 0; worker ceiling > 15 s; both at most 86400 s.
- Docs: GatewayConfiguration, WorkerProcessLauncher (env table now also lists
  the previously missing MXGATEWAY_ALARM_ACK_CLIENT_NAME), worker design doc.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV