20392cf246c71fee4bbeb7a226386488c7e9bf1a
Interlocking changes across the gateway server (shared GatewaySession.cs / SessionManager.cs), committed together: - GWC-01 (Critical): alarm monitor now attaches as an internal (non-counted) distributor subscriber instead of a second raw drain of the single worker event channel; WorkerClient._events -> SingleReader with a claimed-once guard so a future dual-consumer regression throws loudly. - GWC-02 (High): faulted sessions are swept in CloseExpiredLeasesAsync (IsFaultedReapable + FaultedReason); new FaultedGraceSeconds (default 0). - GWC-03 (High): configurable MaxSparseArrayLength (default 1_000_000) enforced before allocation. - TST-02 (High, security): StreamEvents attach now enforces the opening key id -> PermissionDenied on owner mismatch. - TST-12 (Medium): CLAUDE.md retention-defaults sentence corrected. Verified: NonWindows build clean; targeted tests 135/135 on macOS, plus WorkerClientTests 18/18 on the Windows host.