Live MXAccess captures against the windev DEV Galaxy, recorded in docs/LiveCaptures-2026-11-13.md: - OperationComplete follows a Suspend/Activate whose synchronous MxStatus is Pending (advised, resolved item); one Ok row from RespondingLmx. Pinned by the new OperationCompleteLiveProbeTests live fact, with an unresolved-reference negative control. (#211 §3.1) - No public COM event carries completion-only status bytes. All 71 completions were typed MXSTATUS_PROXY[], so they stay raw permanently. (#211 §3.3) - Subtag-mode Clear is drivable: the TestAlarm UDAs are MxSecurityOperate, so AuthenticateUser + WriteSecured toggles them. The new self-driven LiveSubtag_SelfDrivenRaiseThenClear_SynthesizesClear fact asserts the UnackAlm -> UnackRtn Clear (mutation-checked). (#210 §3.7) - The B8 buffered "NoData bootstrap" is a ConfigurationError resolution failure (detail 6 / 1002). The DEV Galaxy has no buffered attribute, so a multi-sample capture needs IDE work. provider_switches was not driven. (#210) - Status-row catalogue for lmxopcua#872: no Warning row seen, and Pending only on the synchronous Suspend/Activate return. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -1040,15 +1040,16 @@ public sealed class WorkerLiveMxAccessSmokeTests(ITestOutputHelper output)
|
||||
|
||||
// Best-effort capture of a SAMPLE-BEARING buffered batch.
|
||||
//
|
||||
// Live observation (B8): immediately after Advise the provider delivers an
|
||||
// initial OnBufferedDataChange with data_type=NoData / raw_data_type=0 and zero
|
||||
// quality+timestamp samples — the buffered analogue of the bad-quality/
|
||||
// registration-state bootstrap event the OnDataChange tests skip with their
|
||||
// family-match predicate. That empty bootstrap is parity, NOT a dropped payload:
|
||||
// the converter ran without crashing and there were simply no samples to carry.
|
||||
// We therefore match only a batch that actually carries samples, so a real
|
||||
// multi-sample conversion can be validated and the empty bootstrap is skipped
|
||||
// rather than mistaken for a defect.
|
||||
// Live observation (B8, re-read 2026-11-13): immediately after Advise the provider
|
||||
// delivers one OnBufferedDataChange with data_type=NoData and zero quality and
|
||||
// timestamp samples. Its status row is ConfigurationError: detail 6
|
||||
// (InvalidReference) for the (item, context) form used here, and detail 1002
|
||||
// (InvalidPropertyId) for a full reference to an attribute without a buffer. It is
|
||||
// a resolution failure, not a bootstrap. The DEV Galaxy has no buffered attribute,
|
||||
// so no sample-bearing batch can arrive (docs/LiveCaptures-2026-11-13.md §5). The
|
||||
// converter handling it without crashing is still worth keeping. We match only a
|
||||
// batch that carries samples, so the test validates a multi-sample conversion if
|
||||
// the item is pointed at a buffered attribute.
|
||||
MxEvent? bufferedBatch = null;
|
||||
try
|
||||
{
|
||||
@@ -1082,9 +1083,9 @@ public sealed class WorkerLiveMxAccessSmokeTests(ITestOutputHelper output)
|
||||
{
|
||||
// RESIDUAL (documented): the command path (AddBufferedItem +
|
||||
// SetBufferedUpdateInterval + Advise) is proven and the buffered EVENT plumbing
|
||||
// is live (the empty NoData bootstrap arrives and converts without crashing),
|
||||
// but the rig did not drive a sample-bearing buffered batch within the timeout
|
||||
// — the same environmental limitation as the externally-undrivable alarm rig.
|
||||
// is live (the NoData resolution-failure event arrives and converts without
|
||||
// crashing), but the rig has no buffered attribute to deliver a sample-bearing
|
||||
// batch (docs/LiveCaptures-2026-11-13.md §5).
|
||||
// The §3.2 OnBufferedDataChange MULTI-SAMPLE conversion therefore remains
|
||||
// unverified live. This is environmental, not a defect — let the test pass.
|
||||
output.WriteLine(
|
||||
|
||||
Reference in New Issue
Block a user