docs(contracts): document unpropagated operator_full_name, reserved enum values, correlation echo
This commit is contained in:
@@ -1019,10 +1019,10 @@ and relies on the gateway to kill the process.
|
||||
|
||||
## Fault Handling
|
||||
|
||||
Worker fault categories:
|
||||
Worker fault categories (`InvalidArguments` and `GatewayAuthenticationFailed`
|
||||
are reserved and never emitted: bootstrap failures exit via `WorkerExitCode`
|
||||
before the pipe exists):
|
||||
|
||||
- `InvalidArguments`
|
||||
- `GatewayAuthenticationFailed`
|
||||
- `ProtocolMismatch`
|
||||
- `ProtocolViolation`
|
||||
- `PipeDisconnected`
|
||||
|
||||
@@ -727,6 +727,10 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
[pbr::OriginalName("ALARM_TRANSITION_KIND_RAISE")] Raise = 1,
|
||||
[pbr::OriginalName("ALARM_TRANSITION_KIND_ACKNOWLEDGE")] Acknowledge = 2,
|
||||
[pbr::OriginalName("ALARM_TRANSITION_KIND_CLEAR")] Clear = 3,
|
||||
/// <summary>
|
||||
/// Reserved: never produced by the gateway or worker. Retained so the numeric
|
||||
/// value is not reused.
|
||||
/// </summary>
|
||||
[pbr::OriginalName("ALARM_TRANSITION_KIND_RETRIGGER")] Retrigger = 4,
|
||||
}
|
||||
|
||||
@@ -12714,6 +12718,11 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
/// <summary>Field number for the "operator_full_name" field.</summary>
|
||||
public const int OperatorFullNameFieldNumber = 6;
|
||||
private string operatorFullName_ = "";
|
||||
/// <summary>
|
||||
/// Accepted for wire compatibility but NOT propagated to MXAccess: the 8-arg
|
||||
/// AlarmAckByName that carried it returns -55. operator_domain IS used (the
|
||||
/// AuthenticateUser identity is "<operator_domain>\<operator_user>").
|
||||
/// </summary>
|
||||
[global::System.Diagnostics.DebuggerNonUserCodeAttribute]
|
||||
[global::System.CodeDom.Compiler.GeneratedCode("protoc", null)]
|
||||
public string OperatorFullName {
|
||||
@@ -13384,6 +13393,11 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
/// <summary>Field number for the "operator_full_name" field.</summary>
|
||||
public const int OperatorFullNameFieldNumber = 8;
|
||||
private string operatorFullName_ = "";
|
||||
/// <summary>
|
||||
/// Accepted for wire compatibility but NOT propagated to MXAccess: the 8-arg
|
||||
/// AlarmAckByName that carried it returns -55. operator_domain IS used (the
|
||||
/// AuthenticateUser identity is "<operator_domain>\<operator_user>").
|
||||
/// </summary>
|
||||
[global::System.Diagnostics.DebuggerNonUserCodeAttribute]
|
||||
[global::System.CodeDom.Compiler.GeneratedCode("protoc", null)]
|
||||
public string OperatorFullName {
|
||||
@@ -17527,6 +17541,9 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
/// <summary>Field number for the "correlation_id" field.</summary>
|
||||
public const int CorrelationIdFieldNumber = 2;
|
||||
private string correlationId_ = "";
|
||||
/// <summary>
|
||||
/// Echoes the request's client_correlation_id.
|
||||
/// </summary>
|
||||
[global::System.Diagnostics.DebuggerNonUserCodeAttribute]
|
||||
[global::System.CodeDom.Compiler.GeneratedCode("protoc", null)]
|
||||
public string CorrelationId {
|
||||
@@ -26125,7 +26142,7 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
/// <summary>
|
||||
/// When the alarm originally entered the active state. Preserved across
|
||||
/// acknowledge transitions so the Part 9 condition keeps the original raise
|
||||
/// time. Unset on retrigger from a previously-cleared condition.
|
||||
/// time. Unset when the raise time is unknown (RETRIGGER is reserved and never produced).
|
||||
/// </summary>
|
||||
[global::System.Diagnostics.DebuggerNonUserCodeAttribute]
|
||||
[global::System.CodeDom.Compiler.GeneratedCode("protoc", null)]
|
||||
|
||||
@@ -132,6 +132,12 @@ namespace ZB.MOM.WW.MxGateway.Contracts.Proto {
|
||||
|
||||
public enum WorkerFaultCategory {
|
||||
[pbr::OriginalName("WORKER_FAULT_CATEGORY_UNSPECIFIED")] Unspecified = 0,
|
||||
/// <summary>
|
||||
/// Values 1 and 2 are reserved: never emitted. Bootstrap failures (bad
|
||||
/// arguments, gateway authentication) exit via WorkerExitCode before the pipe
|
||||
/// exists, so there is no channel to carry a fault. Names kept so the numbers
|
||||
/// are not reused.
|
||||
/// </summary>
|
||||
[pbr::OriginalName("WORKER_FAULT_CATEGORY_INVALID_ARGUMENTS")] InvalidArguments = 1,
|
||||
[pbr::OriginalName("WORKER_FAULT_CATEGORY_GATEWAY_AUTHENTICATION_FAILED")] GatewayAuthenticationFailed = 2,
|
||||
[pbr::OriginalName("WORKER_FAULT_CATEGORY_PROTOCOL_MISMATCH")] ProtocolMismatch = 3,
|
||||
|
||||
@@ -405,6 +405,9 @@ message AcknowledgeAlarmCommand {
|
||||
string operator_user = 3;
|
||||
string operator_node = 4;
|
||||
string operator_domain = 5;
|
||||
// Accepted for wire compatibility but NOT propagated to MXAccess: the 8-arg
|
||||
// AlarmAckByName that carried it returns -55. operator_domain IS used (the
|
||||
// AuthenticateUser identity is "<operator_domain>\<operator_user>").
|
||||
string operator_full_name = 6;
|
||||
// Operator credential used for AuthenticateUser before the AckMsg write.
|
||||
// Implementations must keep this field out of logs, metrics labels, command
|
||||
@@ -435,6 +438,9 @@ message AcknowledgeAlarmByNameCommand {
|
||||
string operator_user = 5;
|
||||
string operator_node = 6;
|
||||
string operator_domain = 7;
|
||||
// Accepted for wire compatibility but NOT propagated to MXAccess: the 8-arg
|
||||
// AlarmAckByName that carried it returns -55. operator_domain IS used (the
|
||||
// AuthenticateUser identity is "<operator_domain>\<operator_user>").
|
||||
string operator_full_name = 8;
|
||||
// Operator credential used for AuthenticateUser before the AckMsg write.
|
||||
// Implementations must keep this field out of logs, metrics labels, command
|
||||
@@ -549,6 +555,7 @@ message ShutdownWorkerCommand {
|
||||
|
||||
message MxCommandReply {
|
||||
string session_id = 1;
|
||||
// Echoes the request's client_correlation_id.
|
||||
string correlation_id = 2;
|
||||
MxCommandKind kind = 3;
|
||||
ProtocolStatus protocol_status = 4;
|
||||
@@ -880,7 +887,7 @@ message OnAlarmTransitionEvent {
|
||||
|
||||
// When the alarm originally entered the active state. Preserved across
|
||||
// acknowledge transitions so the Part 9 condition keeps the original raise
|
||||
// time. Unset on retrigger from a previously-cleared condition.
|
||||
// time. Unset when the raise time is unknown (RETRIGGER is reserved and never produced).
|
||||
google.protobuf.Timestamp original_raise_timestamp = 6;
|
||||
|
||||
// When this specific transition occurred (raise time on Raise, ack time on
|
||||
@@ -930,6 +937,8 @@ enum AlarmTransitionKind {
|
||||
ALARM_TRANSITION_KIND_RAISE = 1;
|
||||
ALARM_TRANSITION_KIND_ACKNOWLEDGE = 2;
|
||||
ALARM_TRANSITION_KIND_CLEAR = 3;
|
||||
// Reserved: never produced by the gateway or worker. Retained so the numeric
|
||||
// value is not reused.
|
||||
ALARM_TRANSITION_KIND_RETRIGGER = 4;
|
||||
}
|
||||
|
||||
|
||||
@@ -127,6 +127,10 @@ enum WorkerState {
|
||||
|
||||
enum WorkerFaultCategory {
|
||||
WORKER_FAULT_CATEGORY_UNSPECIFIED = 0;
|
||||
// Values 1 and 2 are reserved: never emitted. Bootstrap failures (bad
|
||||
// arguments, gateway authentication) exit via WorkerExitCode before the pipe
|
||||
// exists, so there is no channel to carry a fault. Names kept so the numbers
|
||||
// are not reused.
|
||||
WORKER_FAULT_CATEGORY_INVALID_ARGUMENTS = 1;
|
||||
WORKER_FAULT_CATEGORY_GATEWAY_AUTHENTICATION_FAILED = 2;
|
||||
WORKER_FAULT_CATEGORY_PROTOCOL_MISMATCH = 3;
|
||||
|
||||
Reference in New Issue