@@ -849,15 +849,20 @@ MXAccess item addresses for the `InAlarm`, `Acked`, `AckMsg`, and `Priority`
subtags (confirmed AVEVA `AlarmExtension` field names, verified against the live
ZB Galaxy `attribute_definition` rows).
**The list is fixed for the life of the subscription.** The worker builds its
subtag consumer from the targets `SubscribeAlarms` carried and keeps them until
the subscription ends; a second `SubscribeAlarms` on a subscribed session is
rejected, and the only way to replace the list — `UnsubscribeAlarms` then
`SubscribeAlarms` — rebuilds `FailoverAlarmConsumer`, restarting it on the
primary and discarding the warm standby state. Re-sending on a failover would
therefore flap the feed rather than repair it. A monitor restart (a worker fault,
or a gateway restart) re-resolves and re-sends, and that is the supported way to
pick up Galaxy objects added since the monitor started.
The gateway refreshes this list on the existing alarm reconciliation cadence
and immediately before publishing a failover-to-subtag status. It compares a
canonical fingerprint of all six target fields and sends
`UpdateAlarmWatchListCommand` only for a material change. The worker constructs,
subscribes, and attaches the replacement standby on its STA before swapping it
in; a setup failure leaves the previous standby and the current primary/subtag
mode unchanged. The gateway advances its acknowledged fingerprint only after an
OK reply, so a rejected update remains degraded and is retried.
`SubscribeAlarmsCommand.fallback_enabled` distinguishes an initially empty but
discovery-enabled fallback from an intentionally alarm-manager-only
subscription. In the former case the worker creates an empty standby that can be
hot-swapped after discovery recovers. `ForceAlarmManager` leaves the field false
and does not create a standby.
Because the list is fixed, the resolution is **graded** rather than merely
logged (GWC-37). `ResolveAsync` returns an `AlarmWatchListResolution` carrying
@@ -871,10 +876,10 @@ monitor folds the verdict into the alarm feed's `AlarmProviderStatus`:
`AlarmProviderReasons.SubtagDiscoveryFailed` and the failure message, so a
Galaxy Repository outage at startup is a standing status rather than one log
line emitted possibly weeks before the failover that needs the list.
- On the failover edge (`ApplyProviderModeChangeAsync` with `toMode == Subtag`)
the monitor re-resolves and compares against what it sent. A difference is
reported as `AlarmProviderReasons.SubtagWatchListStale` with both counts, on
the same status frame as the failover, because it cannot be applied.
- If the worker rejects a material update, the monitor retains the previous
acknowledged fingerprint and reports
`AlarmProviderReasons.SubtagWatchListStale` with the rejection diagnostic.
The next reconciliation or failover edge retries the same resolved targets.
`degraded` on the status is therefore the OR of "the subtag provider is the one
serving" and "the subtag watch-list cannot cover anything". In `Auto` the second