@@ -849,15 +849,20 @@ MXAccess item addresses for the `InAlarm`, `Acked`, `AckMsg`, and `Priority`
subtags (confirmed AVEVA `AlarmExtension` field names, verified against the live
ZB Galaxy `attribute_definition` rows).
**The list is fixed for the life of the subscription.** The worker builds its
subtag consumer from the targets `SubscribeAlarms` carried and keeps them until
the subscription ends; a second `SubscribeAlarms` on a subscribed session is
rejected, and the only way to replace the list — `UnsubscribeAlarms` then
`SubscribeAlarms` — rebuilds `FailoverAlarmConsumer`, restarting it on the
primary and discarding the warm standby state. Re-sending on a failover would
therefore flap the feed rather than repair it. A monitor restart (a worker fault,
or a gateway restart) re-resolves and re-sends, and that is the supported way to
pick up Galaxy objects added since the monitor started.
The gateway refreshes this list on the existing alarm reconciliation cadence
and immediately before publishing a failover-to-subtag status. It compares a
canonical fingerprint of all six target fields and sends
`UpdateAlarmWatchListCommand` only for a material change. The worker constructs,
subscribes, and attaches the replacement standby on its STA before swapping it
in; a setup failure leaves the previous standby and the current primary/subtag
mode unchanged. The gateway advances its acknowledged fingerprint only after an
OK reply, so a rejected update remains degraded and is retried.
`SubscribeAlarmsCommand.fallback_enabled` distinguishes an initially empty but
discovery-enabled fallback from an intentionally alarm-manager-only
subscription. In the former case the worker creates an empty standby that can be
hot-swapped after discovery recovers. `ForceAlarmManager` leaves the field false
and does not create a standby.
Because the list is fixed, the resolution is **graded** rather than merely
logged (GWC-37). `ResolveAsync` returns an `AlarmWatchListResolution` carrying
@@ -871,10 +876,10 @@ monitor folds the verdict into the alarm feed's `AlarmProviderStatus`:
`AlarmProviderReasons.SubtagDiscoveryFailed` and the failure message, so a
Galaxy Repository outage at startup is a standing status rather than one log
line emitted possibly weeks before the failover that needs the list.
- On the failover edge (`ApplyProviderModeChangeAsync` with `toMode == Subtag`)
the monitor re-resolves and compares against what it sent. A difference is
reported as `AlarmProviderReasons.SubtagWatchListStale` with both counts, on
the same status frame as the failover, because it cannot be applied.
- If the worker rejects a material update, the monitor retains the previous
acknowledged fingerprint and reports
`AlarmProviderReasons.SubtagWatchListStale` with the rejection diagnostic.
The next reconciliation or failover edge retries the same resolved targets.
`degraded` on the status is therefore the OR of "the subtag provider is the one
serving" and "the subtag watch-list cannot cover anything". In `Auto` the second
+9
View File
@@ -40,6 +40,15 @@ the corresponding MXAccess `AddItem`, `Advise`, `UnAdvise`, and `RemoveItem`
calls sequentially on the session STA and preserves input order in the result
list.
The shared alarm command model includes `SubscribeAlarms` and
`UpdateAlarmWatchList`. `SubscribeAlarmsCommand.fallback_enabled` makes an empty
initial watch list explicitly fallback-capable, allowing discovery recovery to
populate a standby without restarting the primary alarm-manager subscription.
`UpdateAlarmWatchListCommand.watch_list` is the complete replacement list. The
worker prepares the replacement on its STA before swapping it into the existing
failover consumer and returns a normal `MxCommandReply`; callers must treat only
`protocol_status = OK` as acknowledgement of the new list.
The command model also includes bulk write/read command kinds:
`WriteBulk`, `Write2Bulk`, `WriteSecuredBulk`, `WriteSecured2Bulk`, and
`ReadBulk`. They are unary `Invoke` payloads on the same `MxAccessGateway`
+1 -1
View File
@@ -439,7 +439,7 @@ behavior.
| `MxGateway:Alarms:Enabled` | `false` | Gates the gateway's always-on central alarm monitor. When `true`, the gateway opens one gateway-owned worker session dedicated to alarms, caches the active-alarm set, and fans it out to every client through the `StreamAlarms` RPC — no client opens its own session to see alarms. |
| `MxGateway:Alarms:SubscriptionExpression` | _(empty)_ | AVEVA alarm-subscription expression the monitor subscribes on startup, in canonical `\\<machine>\Galaxy!<area>` form. The literal `Galaxy` provider is correct regardless of the Galaxy database name. When empty and `Enabled` is `true`, the gateway falls back to `\\<MachineName>\Galaxy!<DefaultArea>` if `DefaultArea` is set. |
| `MxGateway:Alarms:DefaultArea` | _(empty)_ | Area name used to compose a default subscription when `SubscriptionExpression` is empty. If both are empty while `Enabled` is `true`, the monitor faults with a configuration diagnostic. |
| `MxGateway:Alarms:ReconcileIntervalSeconds` | `30` | How often the monitor reconciles its in-process alarm cache against the worker's authoritative active-alarm snapshot, catching transitions the live poll-and-diff feed missed. Floored at 5 seconds. |
| `MxGateway:Alarms:ReconcileIntervalSeconds` | `30` | How often the monitor re-resolves and, on material change, hot-swaps the subtag fallback watch-list, then reconciles its in-process alarm cache against the worker's authoritative active-alarm snapshot. The acknowledged watch-list fingerprint advances only after an OK worker reply. Floored at 5 seconds. |
| `MxGateway:Alarms:PollIntervalMilliseconds` | `500` | Cadence at which the worker's STA polls the AVEVA alarm consumer (`GetXmlCurrentAlarms2`) for the active-alarm snapshot the live feed diffs. Must be between `100` and `3600000` (one hour): every poll is a COM call plus an XML parse on the same STA that serves reads and writes, so a tighter cadence starves the command path, while a value above an hour stops being a cadence and silently disables alarm polling. The gateway conveys the value to the worker via the `MXGATEWAY_ALARM_POLL_INTERVAL_MS` environment variable; a missing or out-of-range value leaves the worker on the 500 ms default rather than failing the session. |
| `MxGateway:Alarms:MaxAlarmsPerFetch` | `1024` | Cap the worker passes to `GetXmlCurrentAlarms2`'s `maxAlmCnt`. Must be between `64` and `65536` — the worker is a 32-bit process that materializes each reply as one BSTR plus a full `XmlDocument`, so an unbounded cap faults the STA with an out-of-memory rather than merely slowing it. It doubles as the **truncation threshold**: a fetch returning exactly this many records is treated as truncated, because the COM API caps its reply with no "more available" flag. On a truncated poll the worker retains the alarms the capped reply could not mention instead of letting their absence read as a clear, and logs a rate-limited `AlarmSnapshotTruncated` warning to its stderr (identifiers and counts only). **Remediation when you see that warning: raise this value** so the steady-state active-alarm count fits inside one fetch. A galaxy permanently above the cap holds stale entries in the snapshot until a sub-cap poll, and loses clear→re-raise cycles that happen entirely out of window (see `docs/DesignDecisions.md`). Conveyed to the worker via the `MXGATEWAY_ALARM_MAX_ALARMS_PER_FETCH` environment variable; a missing or out-of-range value leaves the worker on the 1024 default. |
+12
View File
@@ -351,6 +351,18 @@ native client correlating by handle has the identical ambiguity). The exposure
is bounded: `statuses` is an enrichment field, and `Hresult`/`ProtocolStatus`
stay acceptance-only regardless of which completion (if any) was attributed.
## Live alarm watch-list replacement
An auto-mode `SubscribeAlarms` with `fallback_enabled = true` always builds a
`FailoverAlarmConsumer`, even when initial discovery supplied no targets. The
handler retains the subscription expression so `UpdateAlarmWatchList` can build
and subscribe a new subtag consumer entirely on the session STA. The failover
consumer attaches the replacement's transition callback before swapping the
standby reference, then detaches and disposes the old standby. If construction,
subscription, or attachment fails, it disposes the replacement and preserves
the old standby. The active-provider selector is never reset, so primary mode
stays primary and subtag mode immediately delegates to the new standby.
## COM Creation
The MXAccess analysis source at `C:\Users\dohertj2\Desktop\mxaccess` identifies