feat(gateway,worker): configurable worker heartbeat send interval and stuck ceiling (mxaccessgw#218)
ci / nightly-windev (push) Has been skipped
ci / windows-x86 (push) Successful in 1m32s
ci / java (push) Successful in 2m57s
ci / portable (push) Failing after 5m1s

The worker's heartbeat send interval (5 s) and its own STA-watchdog stuck
ceiling (75 s) were compile-time defaults the gateway never reached, and
nothing checked that the gateway's HeartbeatGraceSeconds exceeded the real send
interval, so a misconfigured grace could kill healthy workers.

- New MxGateway:Worker options WorkerHeartbeatSendIntervalSeconds (default 5)
  and WorkerHeartbeatStuckCeilingSeconds (default 75), exported by
  WorkerProcessLauncher as MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS and
  MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS, the same env-var path the other
  worker settings use.
- The worker's production WorkerPipeSession reads them through
  WorkerPipeSessionOptions.FromEnvironment; a missing/invalid value, or a
  ceiling not above the worker's 15 s watchdog grace, keeps the default rather
  than failing the worker.
- Startup validation: HeartbeatGraceSeconds > WorkerHeartbeatSendIntervalSeconds;
  send interval > 0; worker ceiling > 15 s; both at most 86400 s.
- Docs: GatewayConfiguration, WorkerProcessLauncher (env table now also lists
  the previously missing MXGATEWAY_ALARM_ACK_CLIENT_NAME), worker design doc.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
Joseph Doherty
2026-11-09 13:19:32 -05:00
parent 29d9510b4e
commit 2e52f9f5e8
13 changed files with 284 additions and 9 deletions
@@ -16,6 +16,9 @@ public sealed class GatewayOptionsValidator : OptionsValidatorBase<GatewayOption
private const int MinimumWorkerEventQueueCapacity = 1000;
private const int MaximumWorkerEventQueueCapacity = 1_000_000;
// The worker heartbeat settings travel as int milliseconds; a day keeps them far inside that.
private const int MaximumWorkerHeartbeatSeconds = 86_400;
// Whether the host is running in the Production environment. Drives the production-only
// hard-stops (dashboard login disabled, plaintext LDAP transport) that must abort startup
// rather than merely warn. Non-production hosts keep the permissive dev posture.
@@ -280,6 +283,39 @@ public sealed class GatewayOptionsValidator : OptionsValidatorBase<GatewayOption
"MxGateway:Worker:HeartbeatGraceSeconds must be greater than or equal to HeartbeatCheckIntervalSeconds.");
}
AddIfNotPositive(
options.WorkerHeartbeatSendIntervalSeconds,
"MxGateway:Worker:WorkerHeartbeatSendIntervalSeconds must be greater than zero.",
builder);
// The gateway's grace is measured against heartbeats the worker sends on its own interval:
// a grace at or below that interval declares a healthy worker dead in the gap between two
// heartbeats (mxaccessgw#218).
if (options.WorkerHeartbeatSendIntervalSeconds > 0
&& options.HeartbeatGraceSeconds <= options.WorkerHeartbeatSendIntervalSeconds)
{
builder.Add(
"MxGateway:Worker:HeartbeatGraceSeconds must be greater than WorkerHeartbeatSendIntervalSeconds.");
}
if (options.WorkerHeartbeatSendIntervalSeconds > MaximumWorkerHeartbeatSeconds)
{
builder.Add(
$"MxGateway:Worker:WorkerHeartbeatSendIntervalSeconds must be at most {MaximumWorkerHeartbeatSeconds}.");
}
if (options.WorkerHeartbeatStuckCeilingSeconds > MaximumWorkerHeartbeatSeconds)
{
builder.Add(
$"MxGateway:Worker:WorkerHeartbeatStuckCeilingSeconds must be at most {MaximumWorkerHeartbeatSeconds}.");
}
if (options.WorkerHeartbeatStuckCeilingSeconds <= WorkerOptions.WorkerWatchdogGraceSeconds)
{
builder.Add(
$"MxGateway:Worker:WorkerHeartbeatStuckCeilingSeconds must be greater than the worker's {WorkerOptions.WorkerWatchdogGraceSeconds}-second watchdog grace.");
}
AddIfNotPositive(
options.EventChannelFullModeTimeoutMilliseconds,