feat(gateway,worker): configurable worker heartbeat send interval and stuck ceiling (mxaccessgw#218)
The worker's heartbeat send interval (5 s) and its own STA-watchdog stuck ceiling (75 s) were compile-time defaults the gateway never reached, and nothing checked that the gateway's HeartbeatGraceSeconds exceeded the real send interval, so a misconfigured grace could kill healthy workers. - New MxGateway:Worker options WorkerHeartbeatSendIntervalSeconds (default 5) and WorkerHeartbeatStuckCeilingSeconds (default 75), exported by WorkerProcessLauncher as MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS and MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS, the same env-var path the other worker settings use. - The worker's production WorkerPipeSession reads them through WorkerPipeSessionOptions.FromEnvironment; a missing/invalid value, or a ceiling not above the worker's 15 s watchdog grace, keeps the default rather than failing the worker. - Startup validation: HeartbeatGraceSeconds > WorkerHeartbeatSendIntervalSeconds; send interval > 0; worker ceiling > 15 s; both at most 86400 s. - Docs: GatewayConfiguration, WorkerProcessLauncher (env table now also lists the previously missing MXGATEWAY_ALARM_ACK_CLIENT_NAME), worker design doc. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
@@ -28,7 +28,7 @@ diagnostics can report the launch command without exposing the secret.
|
||||
|
||||
All launch-variable names live in the shared Contracts
|
||||
`WorkerLaunchEnvironment` class and are consumed by both the launcher and the
|
||||
worker. The launcher always exports all six values:
|
||||
worker. The launcher always exports every value below:
|
||||
|
||||
| Environment variable | Gateway source | Worker default when missing/invalid |
|
||||
|---|---|---|
|
||||
@@ -38,6 +38,9 @@ worker. The launcher always exports all six values:
|
||||
| `MXGATEWAY_EVENT_QUEUE_CAPACITY` | `MxGateway:Worker:EventQueueCapacity` | `10000` events |
|
||||
| `MXGATEWAY_ALARM_POLL_INTERVAL_MS` | `MxGateway:Alarms:PollIntervalMilliseconds` | `500` ms |
|
||||
| `MXGATEWAY_ALARM_MAX_ALARMS_PER_FETCH` | `MxGateway:Alarms:MaxAlarmsPerFetch` | `1024` alarms |
|
||||
| `MXGATEWAY_ALARM_ACK_CLIENT_NAME` | `MxGateway:Alarms:AckClientName` | `MxGateway` |
|
||||
| `MXGATEWAY_WORKER_HEARTBEAT_SEND_INTERVAL_MS` | `MxGateway:Worker:WorkerHeartbeatSendIntervalSeconds` (× 1000) | `5000` ms |
|
||||
| `MXGATEWAY_WORKER_HEARTBEAT_STUCK_CEILING_MS` | `MxGateway:Worker:WorkerHeartbeatStuckCeilingSeconds` (× 1000) | `75000` ms (also kept when the value is not above the worker's 15 s watchdog grace) |
|
||||
|
||||
The write-completion wait applies to the four single-item write variants:
|
||||
`Write`, `Write2`, `WriteSecured`, and `WriteSecured2`. Bulk writes report COM
|
||||
|
||||